Provided by: dcmtk_3.6.2-3build3_amd64 bug

NAME

       dcm2pdf - Extract PDF file from DICOM encapsulated PDF

SYNOPSIS

       dcm2pdf [options] dcmfile-in pdffile-out

DESCRIPTION

       The dcm2pdf utility reads a DICOM file of the Encapsulated PDF Storage SOP Class (dcmfile-
       in), extracts the embedded PDF document and writes it to  an  output  file  (pdffile-out).
       Optionally a command can be executed after the creation of the PDF file.

PARAMETERS

       dcmfile-in   DICOM input filename

       pdffile-out  PDF output filename

OPTIONS

   general options
         -h   --help
                print this help text and exit

              --version
                print version information and exit

              --arguments
                print expanded command line arguments

         -q   --quiet
                quiet mode, print no warnings and errors

         -v   --verbose
                verbose mode, print processing details

         -d   --debug
                debug mode, print debug information

         -ll  --log-level  [l]evel: string constant
                (fatal, error, warn, info, debug, trace)
                use level l for the logger

         -lc  --log-config  [f]ilename: string
                use config file f for the logger

   input options
       input file format:

         +f   --read-file
                read file format or data set (default)

         +fo  --read-file-only
                read file format only

         -f   --read-dataset
                read data set without file meta information

       input transfer syntax:

         -t=  --read-xfer-auto
                use TS recognition (default)

         -td  --read-xfer-detect
                ignore TS specified in the file meta header

         -te  --read-xfer-little
                read with explicit VR little endian TS

         -tb  --read-xfer-big
                read with explicit VR big endian TS

         -ti  --read-xfer-implicit
                read with implicit VR little endian TS

       parsing of odd-length attributes:

         +ao  --accept-odd-length
                accept odd length attributes (default)

         +ae  --assume-even-length
                assume real length is one byte larger

       handling of undefined length UN elements:

         +ui  --enable-cp246
                read undefined len UN as implicit VR (default)

         -ui  --disable-cp246
                read undefined len UN as explicit VR

       handling of defined length UN elements:

         -uc  --retain-un
                retain elements as UN (default)

         +uc  --convert-un
                convert to real VR if known

       automatic data correction:

         +dc  --enable-correction
                enable automatic data correction (default)

         -dc  --disable-correction
                disable automatic data correction

       bitstream format of deflated input:

         +bd  --bitstream-deflated
                expect deflated bitstream (default)

         +bz  --bitstream-zlib
                expect deflated zlib bitstream

   execution options
         -x   --exec  [c]ommand: string
                execute command c after PDF extraction

NOTES

       Option --exec allows for the execution of a certain command line after the creation of the
       PDF document. The command line to be executed is passed to this option as a parameter. The
       specified command line may contain the placeholder '#f', which will be replaced by the PDF
       filename at run time. The specified command line  is  executed  in  the  foreground,  i.e.
       pdf2dcm will be blocked until the command terminates.

LOGGING

       The level of logging output of the various command line tools and underlying libraries can
       be specified by the user. By default, only errors and warnings are written to the standard
       error  stream.  Using option --verbose also informational messages like processing details
       are reported. Option --debug can be used to get more details  on  the  internal  activity,
       e.g.  for  debugging  purposes.  Other  logging levels can be selected using option --log-
       level. In --quiet mode only fatal errors are reported. In such very severe  error  events,
       the  application will usually terminate. For more details on the different logging levels,
       see documentation of module 'oflog'.

       In case the logging output should be written to file (optionally with  logfile  rotation),
       to  syslog  (Unix)  or  the  event  log  (Windows)  option  --log-config can be used. This
       configuration file also allows for directing only certain messages to a particular  output
       stream  and  for  filtering certain messages based on the module or application where they
       are generated. An example configuration file is provided in <etcdir>/logger.cfg.

COMMAND LINE

       All command line tools use the following notation for parameters: square brackets  enclose
       optional  values  (0-1),  three  trailing  dots  indicate that multiple values are allowed
       (1-n), a combination of both means 0 to n values.

       Command line options are distinguished from parameters by  a  leading  '+'  or  '-'  sign,
       respectively. Usually, order and position of command line options are arbitrary (i.e. they
       can appear anywhere). However, if options are mutually exclusive the rightmost  appearance
       is used. This behavior conforms to the standard evaluation rules of common Unix shells.

       In  addition,  one or more command files can be specified using an '@' sign as a prefix to
       the filename (e.g. @command.txt). Such a command argument is replaced by  the  content  of
       the corresponding text file (multiple whitespaces are treated as a single separator unless
       they appear between two quotation marks) prior to any further evaluation. Please note that
       a  command  file  cannot  contain another command file. This simple but effective approach
       allows one to summarize common combinations of options/parameters and avoids  longish  and
       confusing command lines (an example is provided in file <datadir>/dumppat.txt).

ENVIRONMENT

       The  dcm2pdf  utility  will  attempt  to  load  DICOM  data  dictionaries specified in the
       DCMDICTPATH environment variable. By default, i.e. if the DCMDICTPATH environment variable
       is  not  set,  the  file <datadir>/dicom.dic will be loaded unless the dictionary is built
       into the application (default for Windows).

       The default behavior should be preferred and the  DCMDICTPATH  environment  variable  only
       used when alternative data dictionaries are required. The DCMDICTPATH environment variable
       has the same format as the Unix shell PATH  variable  in  that  a  colon  (':')  separates
       entries. On Windows systems, a semicolon (';') is used as a separator. The data dictionary
       code will attempt to load each file specified in the DCMDICTPATH environment variable.  It
       is an error if no data dictionary can be loaded.

SEE ALSO

       pdf2dcm(1)

COPYRIGHT

       Copyright (C) 2007-2014 by OFFIS e.V., Escherweg 2, 26121 Oldenburg, Germany.