Provided by: hpoj_0.91-9_i386 bug

NAME

       hpoj reference: "ptal-printd"

SYNOPSIS

       ptal-printd devname [options...]

DESCRIPTION

       The "ptal-printd" daemon creates a special file (specifically, a named
       pipe), which simulates a traditional unidirectional printer character
       device.  Any data written to this pipe special file, presumably by the
       print spooler, is correctly routed through "libptal", "ptal-mlcd", and
       on to the printer.  Using "ptal-printd" makes it easy to set up a print
       queue in conjunction with the hpoj software, because given a particular
       print spooler, almost exactly the same procedure is used to set up
       printing with an hpoj-driven multi-function peripheral as would be used
       to set up printing with a single-function printer.  The only difference
       is where the print job data goes; instead of printing to something like
       "/dev/lp0" or "/dev/usb/lp0", the print queue is configured to print to
       something like "/var/run/ptal-printd/mlc_par_OfficeJet_Series_700" or
       "/var/run/ptal-printd/mlc_usb_OfficeJet_G85".  Important: If you’re
       using CUPS (Common UNIX Printing System) as your print spooler, then
       "ptal-printd" likely will not work for you, because for security
       reasons newer versions of CUPS refuse to print to arbitrary file
       locations.  The hpoj software now includes a CUPS "ptal" backend
       ("ptal-cups") which you should use instead of "ptal-printd".  Click
       here for more information on setting up printing with the hpoj
       software.  Syntax The "ptal-printd" command-line syntax is as follows:

OPTIONS

       ·   "devname" is the PTAL device name (required)

       Recommended options:

       ·   "-like /dev/lp0" -- Copies the pipe’s permissions (mode, owner, and
           group) from the "/dev/lp0" device node.  It’s probably OK to
           specify "/dev/lp0" regardless of how your device is connected, as
           long as the specified device node is actually present on your
           system.  However, this is not necessarily the case anymore with the
           advent of "devfs" on some distributions, so "ptal-init" now caches
           these permissions in a separate file ("/etc/ptal/ptal-printd-like")
           and passes it to ""ptal-printd -like"".

       ·   "-morepipes n" -- Creates n additional pipes (for example, 9) for
           this device, in case you want to set up multiple print queues.

       Other possible options (not necessary in most cases):

       ·   "-pipename filename" -- Sets name of pipe.  The default is based on
           the PTAL device name, with colon characters mapped to underscores.

       ·   "-pipepath path" -- Sets path of pipe if name doesn’t contain a
           path (i.e. no slashes).  The default path is
           "/var/run/ptal-printd".

       ·   "-colon character" -- Sets character to replace colon when using
           default pipename, since colons have a special meaning in
           "/etc/printcap".  The default is the underscore character.

       ·   "-mode 0octal" -- Sets pipe permissions (use leading 0 for octal).
           The default is 0622 (user read/write, group/other write-only).
           Since it is set explicitly in the code, the "umask" setting doesn’t
           affect it.

       ·   "-owner uid" -- Sets pipe owner (numeric user ID only).  The
           default is the current effective UID.

       ·   "-group gid" -- Sets pipe group (numeric group ID only).  The
           default is the current effective GID.

       ·   "-nofork" -- Runs in the foreground instead of the default as a
           background daemon.

       ·   "-retrydelay seconds" -- Sets retry delay if PTAL print-channel
           open fails.  The default is 30 seconds.

       ·   "-timeout seconds" -- Sets idle timeout, where the PTAL print
           channel is closed if no data or end-of-file is received.  The
           default is no timeout.

       ·   "-uel", "-nouel" -- Enables/disables wrapping jobs with
           UEL/end-of-job escape sequences.  The default is disabled.

NOTES

       Previous versions of "ptal-printd" used "/dev/ptal-printd" as the
       default "-pipepath".  That has now been changed to
       "/var/run/ptal-printd", because some platforms have a read-only "/dev"
       file system.  For the sake of backwards compatibility, "ptal-init"
       attempts to create a symlink from "/dev/ptal-printd" to
       "/var/run/ptal-printd" so you don’t have to recreate your print queues
       when upgrading from a previous hpoj version.  If you’re setting up
       multiple print queues to the same device, then you should ensure that
       the ""-morepipes n"" option is passed to "ptal-printd".  This option
       causes the specified number of additional pipes (for example, 9) to be
       created with the same base name as the "main" pipe but with two
       underscores (or the character specified by "-colon") and a 1-based
       index appended, for example, "/var/run/ptal-printd/mlc_usb_PSC_750",
       "/var/run/ptal-printd/mlc_usb_PSC_750__1",
       "/var/run/ptal-printd/mlc_usb_PSC_750__2", etc.  Simply set each print
       queue to send its data to a different one of these pipes to ensure that
       print data from multiple queues doesn’t get interleaved (with quite
       undesirable results).  Don’t confuse the "ptal-printd" daemon (with a
       trailing ""d"") and the "ptal-print" command-line utility (without a
       trailing ""d""), which is an alias for "ptal-connect".  "ptal-printd"
       logs startup and error messages to syslog ("/var/log/messages") in
       addition to logging to standard error.  If you specify the "-uel"
       switch, a UEL (Universal Escape Language) sequence ("Esc%-12345X") is
       sent before a print job, and a PCL end-of-job sequence ("EscE") and
       another UEL are sent after a print job, to help identify job boundaries
       for the printer.  However, this may not happen in the case of back-to-
       back print jobs, because "ptal-printd" may not get an end-of-file
       indication when reading from the pipe if data from the next job is
       already in the pipe by the time it reads the last data from the
       previous job.  "-nouel" is now the default behavior, because normally
       print drivers automatically add these kinds of escape sequences if
       necessary, the printer already gets job boundaries based on when the
       print channel is closed and reopened between jobs, and it may cause
       problems when printing to devices that don’t support PCL.  If during a
       print job an error occurs with communicating with the device, the rest
       of the print job data is discarded, subject to the limitations
       discussed above regarding "ptal-printd"’s ability to detect boundaries
       of back-to-back jobs.  Subsequent jobs are retried indefinitely if it’s
       not possible to re-open the print channel to the device.