Provided by: nvme-cli_2.8-1build2_amd64 bug

NAME

       nvme-list-ctrl - Send NVMe Identify List Controllers, return result and structure

SYNOPSIS

       nvme list-ctrl <device> [--cntid=<cntid> | -c <cntid>]
                               [--namespace-id=<nsid> | -n <nsid>]
                               [--output-format=<fmt> | -o <fmt>] [--verbose | -v]

DESCRIPTION

       For the NVMe device given, sends an identify command for controller list and provides the
       result and returned structure. This uses either mode 12h or 13h depending on the requested
       namespace identifier.

       The <device> parameter is mandatory and may be either the NVMe character device (ex:
       /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1). The starting controller in
       the list always begins with 0 unless the '--cntid' option is given to override.

       On success, the controller array is printed for each index and controller identifier.

OPTIONS

       -c <cntid>, --cntid=<cntid>
           Retrieve the identify list structure starting with the given controller id.

       -n <nsid>, --namespace-id=<nsid>
           If provided, will request the controllers attached to the specified namespace. If no
           namespace is given, or set to 0, the command requests the controller list for the
           entire subsystem, whether or not they are attached to namespace(s).

       -o <fmt>, --output-format=<fmt>
           Set the reporting format to normal, json or binary. Only one output format can be used
           at a time.

       -v, --verbose
           Increase the information detail in the output.

EXAMPLES

       No examples yet.

NVME

       Part of the nvme-user suite