NAME

       vfs11_vfd  -  HAL  non-realtime  component for Toshiba-Schneider VF-S11 Variable Frequency
       Drives

SYNOPSIS

       vfs11_vfd [OPTIONS]

DESCRIPTION

       This manual page explains the vfs11_vfd component. This component reads and writes to  the
       vfs11 via a Modbus connection.

       vfs11_vfd is for use with LinuxCNC.

OPTIONS

       -n --name <halname>
              set the HAL component name

       -d --debug
              Turn  on debugging messages. Also toggled by sending a USR1 signal to the vfs11_vfd
              process.

       -m --modbus-debug
              Turn on Modbus debugging messages. This  will  cause  all  Modbus  messages  to  be
              printed  in  hex  on  the  terminal.   Also toggled by sending a USR2 signal to the
              vfs11_vfd process.

       -I --ini <INI file>
              takes  configuration  from  this  INI  file.   Defaults  to  environment   variable
              INI_FILE_NAME.

       -S --section <section name>
              take configuration from this section in the INI file. Defaults to 'VFS11'.

       -r --report-device
              report device propertiers on console at startup

PINS

       <name>.acceleration-pattern (bit, in)
              when true, set acceleration and deceleration times as defined in registers F500 and
              F501 respectively.  Used in PID  loops  to  choose  shorter  ramp  times  to  avoid
              oscillation.

       <name>.alarm-code (s32, out)
              non-zero  if  drive  is  in alarmed state. Bitmap describing alarm information (see
              register FC91 description).  Use err-reset (see below) to clear the alarm.

       <name>.at-speed (bit, out)
              when drive is at commanded speed (see speed-tolerance below)

       <name>.current-load-percentage (float, out)
              reported from the VFD

       <name>.dc-brake  (bit, in)
              engage the DC brake. Also turns off spindle-on.

       <name>.enable (bit, in)
              enable the VFD.  If false, all operating parameters are still read but  control  is
              released and panel control is enabled (subject to VFD setup).

       <name>.err-reset (bit, in)
              reset  errors (alarms a.k.a Trip and e-stop status).  Resetting the VFD may cause a
              2-second delay until it's rebooted and Modbus is up again.

       <name>.estop (bit, in)
              put the VFD into emergency-stopped status. No operation possible until cleared with
              err-reset or powercycling.

       <name>.frequency-command (float, out)
              current target frequency in Hz as set through speed-command (which is in RPM), from
              the VFD

       <name>.frequency-out (float, out)
              current output frequency of the VFD

       <name>.inverter-load-percentage (float, out)
              current load report from VFD

       <name>.is-e-stopped (bit, out)
              the VFD is in emergency stop status (blinking "E"  on  panel).   Use  err-reset  to
              reboot the VFD and clear the e-stop status.

       <name>.is-stopped (bit, out)
              true when the VFD reports 0 Hz output

       <name>.jog-mode (bit, in)
              1  for ON and 0 for OFF, enables the VF-S11 'jog mode'.  Speed control is disabled,
              and the output frequency is determined by register F262 (preset  to  5  Hz).   This
              might be useful for spindle orientation.

       <name>.max-rpm (float, R)
              actual  RPM  limit  based on maximum frequency the VFD may generate, and the motors
              nameplate values.  For instance, if nameplate-HZ is 50, and nameplate-RPM_ is 1410,
              but  the VFD may generate up to 80Hz, then max-rpm would read as 2256 (80*1410/50).
              The frequency limit is read from  the  VFD  at  startup.   To  increase  the  upper
              frequency  limit,  the  UL and FH parameters must be changed on the panel.  See the
              VF-S11 manual for instructions how to set the maximum frequency.

       <name>.modbus-ok (bit, out)
              true  when  the  Modbus  session  is  successfully  established  and  the  last  10
              transactions returned without error.

       <name>.motor-RPM (float, out)
              estimated current RPM value, from the VFD

       <name>.output-current-percentage (float, out)
              from the VFD

       <name>.output-voltage-percentage (float, out)
              from the VFD

       <name>.output-voltage (float, out)
              from the VFD

       <name>.speed-command (float, in)
              speed sent to VFD in RPM.  It is an error to send a speed faster than the Motor Max
              RPM as set in the VFD

       <name>.spindle-fwd (bit, in)
              1 for FWD and 0 for REV, sent to VFD

       <name>.spindle-on (bit, in)
              1 for ON and 0 for OFF sent to VFD, only on when running

       <name>.spindle-rev (bit, in)
              1 for ON and 0 for OFF, only on when running

       <name>.max-speed (bit, in)
              ignore the loop-time parameter and run Modbus at maximum speed, at the  expense  of
              higher CPU usage.  Suggested use during spindle positioning.

       <name>.status (s32, out)
              Drive Status of the VFD (see the TOSVERT VF-S11 Communications Function Instruction
              Manual, register FD01). A bitmap.

       <name>.trip-code (s32, out)
              trip code if VF-S11 is in tripped state.

       <name>.error-count (s32, RW)
              total number of transactions returning a Modbus error

PARAMETERS

       <name>.frequency-limit (float, RO)
              upper limit read from VFD setup.

       <name>.loop-time (float, RW)
              how often the Modbus is polled (default interval 0.1 seconds)

       <name>.nameplate-HZ (float, RW)
              Nameplate Hz of motor (default 50).  Used to calculate target  frequency  (together
              with nameplate-RPM ) for a target RPM value as given by speed-command.

       <name>.nameplate-RPM (float, RW)
              Nameplate RPM of motor (default 1410)

       <name>.rpm-limit (float, RW)
              do-not-exceed soft limit for motor RPM (defaults to nameplate-RPM ).

       <name>.tolerance (float, RW)
              speed  tolerance  (default  0.01) for determining whether spindle is at speed (0.01
              meaning: output frequency is within 1% of target frequency)

USAGE

       The vfs11_vfd driver takes precedence over panel control while it is enabled (see  .enable
       pin),  effectively  disabling  the  panel. Clearing the .enable pin re-enableds the panel.
       Pins and parameters can still be set, but will not  be  written  to  the  VFD  untile  the
       .enable pin is set. Operating parameters are still read while bus control is disabled.

       Exiting the vfs11_vfd driver in a controlled will release the VFD from the bus and restore
       panel control.

       See the LinuxCNC  Integrators  Manual  for  more  information.  For  a  detailed  register
       description  of  the  Toshiba  VFD's,  see  the  "TOSVERT  VF-S11  Communications Function
       Instruction Manual" (Toshiba document number E6581222) and the "TOSVERT VF-S11 Instruction
       manual" (Toshiba document number E6581158).

AUTHOR

       Michael Haberler; based on gs2_vfd by Steve Padnos and John Thornton.

LICENSE

       GPL