NAME

       ipmimonitoring - IPMI monitoring utility

SYNOPSIS

       ipmimonitoring [OPTION...]

DESCRIPTION

       ipmimonitoring  is  an  IPMI  sensor  monitoring  tool  that  reports a
       sensor's record id, sensor name, sensor type name, sensor state, sensor
       reading (if appropriate), and the current sensor event.

       Unlike  ipmi-sensors(8),  ipmimonitoring will also report a sensor in a
       NOMINAL,  WARNING,  or  CRITICAL  state.   The  sensor  state   is   an
       interpreted  value based on the current sensor event. By mapping sensor
       readings into NOMINAL, WARNING, or CRITICAL states, it makes monitoring
       easier  across  large numbers of nodes. For more general sensor reading
       use, it is recommended that users use ipmi-sensors(8).

       The sensor state interpretations are determined  by  the  configuration
       file               /etc/ipmi_monitoring_sensors.conf.               See
       ipmi_monitoring_sensors.conf(5) for  more  information  on  configuring
       sensor interpretations.  Interpretation rules have not been written for
       all sensors permutations and types. Subsequently, there may  be  output
       differences  between  ipmi-sensors(8)  and  ipmimonitoring  when sensor
       interpretations are not available. If additional sensor  interpretation
       rules  are  needed,  please  contact  the FreeIPMI maintainers. Default
       interpretation rules may not be correct for a given motherboard.  Users
       should verify that the default settings match their expectations.

       Some  sensors may have a sensor state, reading or event of "N/A" if the
       information is unavailable. This is typical of a  sensor  that  is  not
       enabled or not owned by a BMC. Please see --bridge-sensors option below
       to deal with sensors not owned by a BMC. Sensors need not always report
       a  sensor event. When a sensor event is not present, "NONE" is reported
       for the sensor event.

       Listed below are general IPMI options, tool specific  options,  trouble
       shooting  information,  workaround  information,  examples,  and  known
       issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS

       The  following  options  are  general  options  for  configuring   IPMI
       communication and executing general tool commands.

       -D, --driver-type=IPMIDRIVER
              Specify  the  driver  type  to  use  instead  of  doing  an auto
              selection.  The currently available outofband  drivers  are  LAN
              and  LAN_2_0,  which perform IPMI 1.5 and IPMI 2.0 respectively.
              The currently available inband drivers are KCS, SSIF,  OPENIPMI,
              and SUNBMC.

       --disable-auto-probe
              Do not probe in-band IPMI devices for default settings.

       --driver-address=DRIVER-ADDRESS
              Specify  the  in-band  driver  address to be used instead of the
              probed value. DRIVER-ADDRESS should be prefixed with "0x" for  a
              hex value and '0' for an octal value.

       --driver-device=DEVICE
              Specify the in-band driver device path to be used instead of the
              probed path.

       --register-spacing=REGISTER-SPACING
              Specify the in-band  driver  register  spacing  instead  of  the
              probed value.

       -h, --hostname=IPMIHOST1,IPMIHOST2,...
              Specify   the  remote  host(s)  to  communicate  with.  Multiple
              hostnames may be separated by comma or may  be  specified  in  a
              range format; see HOSTRANGED SUPPORT below.

       -u, --username=USERNAME
              Specify  the username to use when authenticating with the remote
              host.  If not specified, a null  (i.e.  anonymous)  username  is
              assumed. The user must have atleast OPERATOR privileges in order
              for this tool to operate fully.

       -p, --password=PASSWORD
              Specify the password to use when authenticationg with the remote
              host.   If  not  specified,  a null password is assumed. Maximum
              password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password  to  avoid  possibility  of  listing  it  in
              process lists.

       -k, --k-g=K_G
              Specify  the  K_g  BMC  key  to use when authenticating with the
              remote host for IPMI 2.0.  If  not  specified,  a  null  key  is
              assumed. To input the key in hexadecimal form, prefix the string
              with '0x'. E.g., the key 'abc' can be entered  with  the  either
              the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt  for  k-g  to  avoid possibility of listing it in process
              lists.

       --session-timeout=MILLISECONDS
              Specify the session timeout in milliseconds. Defaults  to  20000
              milliseconds (20 seconds) if not specified.

       --retransmission-timeout=MILLISECONDS
              Specify  the  packet  retransmission  timeout  in  milliseconds.
              Defaults to 1000 milliseconds (1 second) if not  specified.  The
              retransmission   timeout  cannot  be  larger  than  the  session
              timeout.

       -a, --authentication-type=AUTHENTICATION-TYPE
              Specify the IPMI 1.5 authentication type to use.  The  currently
              available  authentication types are NONE, STRAIGHT_PASSWORD_KEY,
              MD2, and MD5. Defaults to MD5 if not specified.

       -I, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
              identifies    a    set   of   authentication,   integrity,   and
              confidentiality algorithms to use for  IPMI  2.0  communication.
              The authentication algorithm identifies the algorithm to use for
              session setup, the integrity algorithm identifies the  algorithm
              to  use  for  session packet signatures, and the confidentiality
              algorithm  identifies  the  algorithm   to   use   for   payload
              encryption.  Defaults to cipher suite ID 3 if not specified. The
              following cipher suite ids are currently supported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None;
              Confidentiality Algorithm = None

              1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
              None; Confidentiality Algorithm = None

              2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
              HMAC-SHA1-96; Confidentiality Algorithm = None

              3  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
              HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

              6 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
              None; Confidentiality Algorithm = None

              7  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
              HMAC-MD5-128; Confidentiality Algorithm = None

              8 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
              HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128

              11  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
              MD5-128; Confidentiality Algorithm = None

              12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
              MD5-128; Confidentiality Algorithm = AES-CBC-128

              17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
              = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

       -l, --privilege-level=PRIVILEGE-LEVEL
              Specify the privilege level to be used. The currently  available
              privilege  levels  are  USER,  OPERATOR,  and ADMIN. Defaults to
              OPERATOR if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify  workarounds  to  vendor  compliance  issues.   Multiple
              workarounds   can   be   specified   separated  by  commas.  See
              WORKAROUNDS below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMIMONITORING OPTIONS

       The following options are specific to Ipmimonitoring.

       -v, --verbose
              Increase verbosity in output. This option will output additional
              sensors that are generally unreadable or uninterpretable.

       -q, --quiet-readings
              Do  not  output sensor reading values by default. This option is
              particularly useful if you want to use hostranged output  across
              a cluster and want to consolidate the output.

       -r "RECORD-IDS-LIST", --record-ids="RECORD-IDS-LIST"
              Specify sensors to show by record id. Multiple record ids can be
              separated  by  commas  or  spaces.  If  both  --record-ids   and
              --sensor-types  are  specified, --record-ids takes precedence. A
              special command line record  id  of  "all",  will  indicate  all
              record  ids  should  be  shown  (may  be  useful  for overriding
              configured defaults).

       -R "RECORD-IDS-LIST", --exclude-record-ids="RECORD-IDS-LIST"
              Specify sensors to not show by record id.  Multiple  record  ids
              can  be  separated  by  commas or spaces. A special command line
              record id of "none", will  indicate  no  record  ids  should  be
              excluded (may be useful for overriding configured defaults).

       -t "SENSOR-TYPE-LIST", --sensor-types=SENSOR-TYPE-LIST
              Specify  sensor types to show sensor outputs for. Multiple types
              can be separated by commas or spaces. If both  --record-ids  and
              --sensor-types  are specified, --record-ids takes precedence.  A
              special command line type of  "all",  will  indicate  all  types
              should  be  shown  (may  be  useful  for  overriding  configured
              defaults).

       -T "SENSOR-TYPE-LIST", --exclude-sensor-types=SENSOR-TYPE-LIST
              Specify sensor types to not show sensor  outputs  for.  Multiple
              types  can  be  eparated  by commas or spaces. A special command
              line type of "none", will indicate no types should  be  excluded
              (may be useful for overriding configured defaults).

       -L, --list-sensor-types
              List sensor types.

       -b, --bridge-sensors
              By  default,  sensors  readings are not attempted for sensors on
              non-BMC owners. By setting this option, sensor requests  can  be
              bridged   to   non-BMC   owners   to   obtain   sensor  readings
              (experimental). Bridging may not work on some  interfaces/driver
              types.

       --shared-sensors
              Some  sensors  share  the same sensor data record (SDR). This is
              typically utilized for system event log (SEL)  entries  and  not
              for  sensor readings. However, there may be some motherboards in
              which this format is utilized for multiple  active  sensors,  or
              the  user  simply  has  interest  in  seeing  the permutation of
              entries shared by a SDR entry.  By  setting  this  option,  each
              sensor  number  shared  by  a  record  will be iterated over and
              output.

       --interpret-oem-data
              Attempt to interpret  OEM  data,  such  as  event  data,  sensor
              readings,  or  general extra info, etc. If an OEM interpretation
              is  not  available,  the  default  output  will  be   generated.
              Correctness  of  OEM interpretations cannot be guaranteed due to
              potential changes OEM vendors may make  in  products,  firmware,
              etc.  See  OEM  INTERPRETATION  below  for  confirmed  supported
              motherboard interpretations.

       --ignore-non-interpretable-sensors
              Ignore non-interpretable sensors  in  output.  Although  usually
              identical,    this    is   semantically   different   that   the
              --ignore-na-sensors option in ipmi-sensors(8).  For example,  if
              an interpretation rule has not been written for a sensor, it may
              not be output.

       --entity-sensor-names
              Output sensor names prefixed with their entity id  and  instance
              number   when   appropriate.  This  may  be  necessary  on  some
              motherboards to help identify what sensors are referencing.  For
              example,  a  motherboard may have multiple sensors named 'TEMP'.
              The entity id and instance number may help clarify which  sensor
              refers to "Processor 1" vs. "Processor 2".

       --no-sensor-type-output
              Do  not show sensor type output for each entry. On many systems,
              the sensor type is redundant to the name of the sensor. This can
              especially  be  true  if --entity-sensor-names is specified.  If
              the sensor name is sufficient, or if the sensor type  is  of  no
              interest  to  the user, this option can be specified to condense
              output.

       --comma-separated-output
              Output fields in comma separated format.

       --no-header-output
              Do not output column headers. May be useful in scripting.

       --non-abbreviated-units
              Output non-abbreviated units (e.g. 'Amps' instead of  'A').  May
              aid  in  disambiguation  of  units  (e.g.  'C'  for  Celsius  or
              Coulombs).

       --legacy-output
              Output in legacy format. Newer options may not be applicable  to
              leagcy output.

       --sensor-config-file=FILE
              Specify an alternate sensor configuration file.

SDR CACHE OPTIONS

       This tool requires access to the sensor data repository (SDR) cache for
       general operation. By default, SDR data will be downloaded  and  cached
       on the local machine. The following options apply to the SDR cache.

       -f, --flush-cache
              Flush  a  cached  version  of  the  sensor data repository (SDR)
              cache. The SDR is typically cached for faster subsequent access.
              However,  it  may need to be flushed and re-generated if the SDR
              has been updated on a system.

       -Q, --quiet-cache
              Do not output information about cache creation/deletion. May  be
              useful in scripting.

       --sdr-cache-directory=DIRECTORY
              Specify  an alternate directory for sensor data repository (SDR)
              caches to be stored or read from. Defaults to the home directory
              if not specified.

       --sdr-cache-recreate
              If  the  SDR  cache  is  out  of  date or invalid, automatically
              recreate the sensor data repository (SDR) cache. This option may
              be useful for scripting purposes.

HOSTRANGED OPTIONS

       The  following  options  manipulate  hostranged  output. See HOSTRANGED
       SUPPORT below for additional information on hostranges.

       -B, --buffer-output
              Buffer hostranged output. For each node, buffer standard  output
              until the node has completed its IPMI operation. When specifying
              this option, data may appear to output slower to the user  since
              the  the entire IPMI operation must complete before any data can
              be  output.   See  HOSTRANGED  SUPPORT  below   for   additional
              information.

       -C, --consolidate-output
              Consolidate hostranged output. The complete standard output from
              every node specified will be consolidated  so  that  nodes  with
              identical  output are not output twice. A header will list those
              nodes  with  the  consolidated  output.  When  this  option   is
              specified,  no  output  can be seen until the IPMI operations to
              all nodes has completed. If the user breaks out of  the  program
              early,  all  currently  consolidated  output will be dumped. See
              HOSTRANGED SUPPORT below for additional information.

       -F, --fanout
              Specify multiple host fanout. A  "sliding  window"  (or  fanout)
              algorithm is used for parallel IPMI communication so that slower
              nodes or timed out nodes will not impede parallel communication.
              The  maximum  number  of  threads  available at the same time is
              limited by the fanout. The default is 64.

       -E, --eliminate
              Eliminate hosts determined as undetected  by  ipmidetect.   This
              attempts  to  remove  the  common  issue of hostranged execution
              timing out due to several nodes being removed from service in  a
              large  cluster.  The  ipmidetectd  daemon must be running on the
              node executing the command.

       --always-prefix
              Always prefix output, even if only  one  host  is  specified  or
              communicating  in-band.  This  option  is  primarily  useful for
              scripting purposes. Option will be ignored if specified with the
              -C option.

HOSTRANGED SUPPORT

       Multiple hosts can be input either as an explicit comma separated lists
       of hosts or a range of hostnames in  the  general  form:  prefix[n-m,l-
       k,...],  where  n  <  m  and  l  < k, etc. The later form should not be
       confused with regular expression character  classes  (also  denoted  by
       []).  For  example, foo[19] does not represent foo1 or foo9, but rather
       represents a degenerate range: foo19.

       This range syntax is meant only as a convenience  on  clusters  with  a
       prefixNN  naming  convention  and specification of ranges should not be
       considered necessary -- the list foo1,foo9 could be specified as  such,
       or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As a reminder to the reader, some shells will interpret brackets ([ and
       ]) for pattern matching. Depending on your shell, it may  be  necessary
       to enclose ranged lists within quotes.

       When  multiple  hosts  are  specified  by  the  user,  a thread will be
       executed for each host in parallel up to the configured  fanout  (which
       can  be  adjusted  via the -F option). This will allow communication to
       large numbers of nodes far more quickly than if done in serial.

       By default, standard output from each node  specified  will  be  output
       with  the  hostname  prepended  to  each  line. Although this output is
       readable in many situations, it may  be  difficult  to  read  in  other
       situations.  For  example,  output  from  multiple  nodes  may be mixed
       together. The -B and -C options can be used to change this default.

       In-band IPMI Communication will be used when the  host  "localhost"  is
       specified.  This  allows  the  user  to  add  the  localhost  into  the
       hostranged output.

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due  to  configuration  problems.  Inband
       IPMI  problems are typically caused by improperly configured drivers or
       non-standard BMCs. IPMI over LAN problems involve a misconfiguration of
       the  remote machine's BMC.  Double check to make sure the following are
       configured properly in  the  remote  machine's  BMC:  IP  address,  MAC
       address,  subnet  mask,  username,  user  enablement,  user  privilege,
       password, LAN privilege, LAN  enablement,  and  allowed  authentication
       type(s). For IPMI 2.0 connections, double check to make sure the cipher
       suite privilege(s) and  K_g  key  are  configured  properly.  The  bmc-
       config(8)  tool  can be used to check and/or change these configuration
       settings.

       The following are common issues for given error messages:

       "username invalid" - The username entered (or a NULL username  if  none
       was  entered)  is  not  available on the remote machine. It may also be
       possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password  if  none
       was  entered)  is not correct. It may also be possible the password for
       the user is not correctly configured on the remote BMC.

       "password verification timeout" - Password verification has timed  out.
       A  "password  invalid"  error  (described  above) or a generic "session
       timeout" (described below) occurred.  During this point in the protocol
       it cannot be differentiated which occurred.

       "k_g  invalid"  -  The  K_g  key entered (or a NULL K_g key if none was
       entered) is not correct. It may also be possible the  K_g  key  is  not
       correctly configured on the remote BMC.

       "privilege level insufficient" - An IPMI command requires a higher user
       privilege than the one authenticated with. Please try  to  authenticate
       with a higher privilege. This may require authenticating to a different
       user which has a higher maximum privilege.

       "privilege level cannot be obtained for  this  user"  -  The  privilege
       level  you  are  attempting  to  authenticate  with  is higher than the
       maximum allowed for this user. Please try again with a lower privilege.
       It  may also be possible the maximum privilege level allowed for a user
       is not configured properly on the remote BMC.

       "authentication type unavailable for attempted privilege level"  -  The
       authentication  type you wish to authenticate with is not available for
       this privilege level. Please try again with an alternate authentication
       type  or  alternate  privilege  level.  It  may  also  be  possible the
       available authentication  types  you  can  authenticate  with  are  not
       correctly configured on the remote BMC.

       "cipher  suite  id  unavailable"  -  The  cipher  suite  id you wish to
       authenticate with is not available on the remote BMC. Please try  again
       with  an  alternate  cipher  suite  id.  It  may  also  be possible the
       available cipher suite ids are not correctly configured on  the  remote
       BMC.

       "ipmi  2.0  unavailable"  -  IPMI  2.0 was not discovered on the remote
       machine. Please try to use IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A  number  of
       potential errors are possible, including an invalid hostname specified,
       an IPMI IP address cannot be resolved,  IPMI  is  not  enabled  on  the
       remote  server,  the  network  connection  is  bad,  etc. Please verify
       configuration and connectivity.

       "session timeout" - The IPMI session has timed out.  Please  reconnect.
       If this error occurs often, you may wish to increase the retransmission
       timeout. Some remote BMCs are considerably slower than others.

       "device not found" - The specified device could not  be  found.  Please
       check configuration or inputs and try again.

       "driver  timeout"  -  Communication with the driver or device has timed
       out. Please try again.

       "message timeout" - Communication with the driver or device  has  timed
       out. Please try again.

       "BMC  busy"  -  The  BMC  is  currently  busy.  It  may  be  processing
       information or have too many simultaneous sessions  to  manage.  Please
       wait and try again.

       "could  not  find inband device" - An inband device could not be found.
       Please check configuration or specify specific device or driver on  the
       command line.

       Please  see  WORKAROUNDS below to also if there are any vendor specific
       bugs that have been discovered and worked around.

IPMIMONITORING TROUBLESHOOTING

       The following are common issues for given error  messages  specifically
       for ipmimonitoring.

       "sensor  config  file  parse  error"  -  A parse error was found in the
       libipmimonitoring(3)   sensor   configuration    file.    Please    see
       libipmimonitoring(3).

WORKAROUNDS

       With  so  many different vendors implementing their own IPMI solutions,
       different vendors may implement their IPMI protocols  incorrectly.  The
       following   lists   the   workarounds  currently  available  to  handle
       discovered compliance issues.

       When possible, workarounds  have  been  implemented  so  they  will  be
       transparent to the user. However, some will require the user to specify
       a workaround be used via the -W option.

       The hardware listed below may only indicate the hardware that a problem
       was  discovered  on.  Newer  versions  of hardware may fix the problems
       indicated below. Similar machines from vendors may or may  not  exhibit
       the  same  problems.  Different vendors may license their firmware from
       the same IPMI firmware developer,  so  it  may  be  worthwhile  to  try
       workarounds listed below even if your motherboard is not listed.

       "assumeio"  -  This  workaround  option  will  assume inband interfaces
       communicate with system I/O rather than being memory-mapped. This  will
       work  around  systems that report invalid base addresses. Those hitting
       this issue may see "device not supported" or  "could  not  find  inband
       device" errors.  Issue observed on HP ProLiant DL145 G1.

       "idzero"  -  This  workaround option will allow empty session IDs to be
       accepted by the client. It works around IPMI sessions that report empty
       session  IDs  to  the client. Those hitting this issue may see "session
       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       "unexpectedauth" - This workaround option will  allow  unexpected  non-
       null  authcodes  to  be  checked as though they were expected. It works
       around an issue when packets contain non-null authentication data  when
       they  should  be null due to disabled per-message authentication. Those
       hitting this issue may see "session timeout" errors. Issue observed  on
       Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       "forcepermsg"   -   This   workaround  option  will  force  per-message
       authentication to be used no matter what is advertised  by  the  remote
       system.  It  works  around  an issue when per-message authentication is
       advertised as disabled  on  the  remote  system,  but  it  is  actually
       required  for  the  protocol. Those hitting this issue may see "session
       timeout" errors.  Issue observed on IBM eServer 325.

       "endianseq" - This workaround  option  will  flip  the  endian  of  the
       session sequence numbers to allow the session to continue properly.  It
       works around IPMI 1.5 session  sequence  numbers  that  are  the  wrong
       endian.  Those  hitting  this  issue  may see "session timeout" errors.
       Issue observed on some Sun ILOM 1.0/2.0 (depends on  service  processor
       endian).

       "authcap"  - This workaround option will skip early checks for username
       capabilities, authentication capabilities, and K_g  support  and  allow
       IPMI  authentication  to  succeed.  It  works around multiple issues in
       which the remote system does not properly report username capabilities,
       authentication  capabilities,  or  K_g status. Those hitting this issue
       may  see  "username  invalid",  "authentication  type  unavailable  for
       attempted privilege level", or "k_g invalid" errors.  Issue observed on
       Asus  P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
       2200/4150/4450 with ELOM.

       "intel20"  - This workaround option will work around several Intel IPMI
       2.0 authentication  issues.  The  issues  covered  include  padding  of
       usernames,  and  password truncation if the authentication algorithm is
       HMAC-MD5-128. Those hitting this  issue  may  see  "username  invalid",
       "password  invalid",  or  "k_g invalid" errors. Issue observed on Intel
       SE7520AF2 with Intel Server Management Module (Professional Edition).

       "supermicro20" -  This  workaround  option  will  work  around  several
       Supermicro  IPMI 2.0 authentication issues on motherboards w/ Peppercon
       IPMI firmware. The  issues  covered  include  handling  invalid  length
       authentication  codes.  Those  hitting  this  issue  may  see "password
       invalid"  errors.   Issue  observed  on  Supermicro  H8QME  with  SIMSO
       daughter card. Confirmed fixed on newerver firmware.

       "sun20" - This workaround option will work work around several Sun IPMI
       2.0 authentication issues. The issues covered include invalid  lengthed
       hash  keys,  improperly  hashed keys, and invalid cipher suite records.
       Those hitting this issue may see  "password  invalid"  or  "bmc  error"
       errors.   Issue  observed  on  Sun Fire 4100/4200/4500 with ILOM.  This
       workaround automatically includes the "opensesspriv" workaround.

       "opensesspriv" - This workaround option will slightly alter  FreeIPMI's
       IPMI 2.0 connection protocol to workaround an invalid hashing algorithm
       used by the remote system. The privilege level  sent  during  the  Open
       Session  stage  of  an  IPMI  2.0  connection  is used for hashing keys
       instead of the privilege level sent during the RAKP1 connection  stage.
       Those  hitting this issue may see "password invalid", "k_g invalid", or
       "bad  rmcpplus  status  code"  errors.   Issue  observed  on  Sun  Fire
       4100/4200/4500  with  ILOM,  Inventec  5441/Dell  Xanadu II, Supermicro
       X8DTH, Supermicro X8DTG, and Intel S5500WBV/Penguin  Relion  700.  This
       workaround is automatically triggered with the "sun20" workaround.

       "integritycheckvalue"  -  This  workaround  option  will work around an
       invalid integrity check value during an IPMI 2.0 session  establishment
       when  using  Cipher  Suite  ID 0. The integrity check value should be 0
       length, however the remote motherboard responds with a non-empty field.
       Those  hitting  this issue may see "k_g invalid" errors. Issue observed
       on Supermicro  X8DTG,  Supermicro  X8DTU,  and  Intel  S5500WBV/Penguin
       Relion 700.

OEM INTERPRETATION

       The  following  motherboards are confirmed to have atleast some support
       by the --interpret-oem-data option. While highly probable the OEM  data
       interpretations  would  work  across  other  motherboards  by  the same
       manufacturer, there are no guarantees.

       Currently None

EXAMPLES

       # ipmimonitoring

       Show all sensors on the local machine.

       # ipmimonitoring --record-ids="82 11 7 102"

       Show sensors #82, #11, #7 and #102 on the local machine.

       # ipmimonitoring --sensor-types=TEMPERATURE

       Show all sensors in TEMPERATURE type on the local machine.

       # ipmimonitoring -h ahost -u myusername -p mypassword

       Show all sensors on a remote machine using IPMI over LAN.

       # ipmimonitoring -h mycluster[0-127] -u myusername -p mypassword

       Show all sensors across a cluster using IPMI over LAN.

KNOWN ISSUES

       On older operating systems, if you input your username,  password,  and
       other  potentially  security  relevant information on the command line,
       this information may be discovered by other users when using tools like
       the  ps(1) command or looking in the /proc file system. It is generally
       more secure to input password information with options like the  -P  or
       -K  options.  Configuring security relevant information in the FreeIPMI
       configuration file would also  be  an  appropriate  way  to  hide  this
       information.

       In  order  to  prevent  brute force attacks, some BMCs will temporarily
       "lock up" after a number of remote authentication errors. You may  need
       to  wait awhile in order to this temporary "lock up" to pass before you
       may authenticate again.

       Some sensors may be output because the owner of the sensor is  not  the
       BMC.  To  attempt  to bridge sensors and access sensors not on the BMC,
       users may wish to try the -b or --bridge-sensors options.

FILES

       /etc/ipmi_monitoring_sensors.conf

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright (C) 2007-2010 Lawrence Livermore National Security, LLC.
       Copyright (C) 2006-2007 The Regents of the University of California.

       This program is free software; you can redistribute it and/or modify it
       under  the  terms of the GNU General Public License as published by the
       Free Software Foundation; either version 2 of the License, or (at  your
       option) any later version.

SEE ALSO

       libipmimonitoring(3),   ipmi_monitoring_sensors.conf(5),   freeipmi(7),
       ipmi-sensors(8)

       http://www.gnu.org/software/freeipmi/