Provided by: pcp_3.5.11_amd64 bug

NAME

       PCPIntro - introduction to the Performance Co-Pilot (PCP)

INTRODUCTION

       The  Performance  Co-Pilot  (PCP)  is  an SGI toolkit designed for monitoring and managing
       system-level performance.  These services are distributed and scalable to accommodate  the
       most complex system configurations and performance problems.

       PCP supports many different platforms, including (but not limited to) Linux, MacOSX, IRIX,
       AIX, Solaris and Windows.  From a high-level PCP can be considered to contain two  classes
       of software utility:

       PCP Collectors
               These  are the parts of PCP that collect and extract performance data from various
               sources, e.g. the Linux  /proc  pseudo  filesystem.   These  are  available  under
               GPL/LPGL from http://oss.sgi.com/projects/pcp.

       PCP Monitors
               These  are  the  parts of PCP that display data collected from hosts (or archives)
               that have the PCP Collector installed.  Many monitor tools are available  as  part
               of  PCP  under  GPL/LPGL  from  http://oss.sgi.com/projects/pcp.  Other (typically
               graphical) monitoring tools are available separately in the PCP GUI package.

       This manual entry describes the  high-level  features  and  options  common  to  most  PCP
       utilities available on all platforms.

OVERVIEW

       The  PCP  architecture  is  distributed  in  the  sense that any PCP tool may be executing
       remotely.  On the host (or hosts) being monitored, each  domain  of  performance  metrics,
       whether  the  kernel,  a  service  layer,  a  database management system, a web server, an
       application,   etc.   requires  a  Performance  Metrics  Domain  Agent  (PMDA)  which   is
       responsible  for  collecting  performance  measurements  from  that domain.  All PMDAs are
       controlled by the Performance Metrics Collector Daemon (pmcd(1)) on the same host.

       Client applications (the monitoring tools) connect to pmcd(1), which acts as a router  for
       requests,  by  forwarding  requests to the appropriate PMDA and returning the responses to
       the clients.  Clients may also access performance data from a PCP archive  (created  using
       pmlogger(1)) for retrospective analysis.

       The  following  performance  monitoring  applications  are  primarily  console  based, are
       typically run directly from the command line, and are all part of the base PCP package.

       Each tool or command is documented completely in its own reference page.

       pmstat Outputs an ASCII high-level summary of system performance.

       pmie   An inference engine that can evaluate predicate-action rules to perform alarms  and
              automate system management tasks.

       pminfo Interrogate specific performance metrics and the metadata that describes them.

       pmlogger
              Generates  PCP  archives  of  performance  metrics  suitable for replay by most PCP
              tools.

       pmval  Simple periodic reporting for some or all instances of a performance  metric,  with
              optional VCR time control.

       If the PCP GUI package is installed then the following additional tools are available.

       pmchart
              Displays  trends  over time of arbitrarily selected performance metrics from one or
              more hosts.

       pmtime Time control utility for coordinating the time between  multiple  tools  (including
              pmchart and pmval).

       pmdumptext
              Produce ASCII reports for arbitrary combinations of performance metrics.

COMMON COMMAND LINE ARGUMENTS

       There  is  a  set  of common command line arguments that are used consistently by most PCP
       tools.

       -a archive
              Performance metric information is retrospectively retrieved  from  the  Performance
              Co-Pilot (PCP) archive, previously generated by pmlogger(1).  The -a and -h options
              are mutually exclusive.

              archive is either the base name common to all of the physical files created  by  an
              instance  of  pmlogger(1),  or any one of the physical files, e.g.  myarchive (base
              name) or myarchive.meta (the metadata file) or myarchive.index (the temporal index)
              or   myarchive.0   (the  first  data  volume  of  archive)  or  myarchive.0.bz2  or
              myarchive.0.bz (the first data volume compressed with bzip2(1))  or  myarchive.0.gz
              or  myarchive.0.Z or myarchive.0.z (the first data volume compressed with gzip(1)),
              myarchive.1 or myarchive.3.bz2 or myarchive.42.gz etc.

       -a archive[,archive,...]
              An alternate form of -a for applications that are able to handle multiple archives.

       -h hostname
              Unless directed to another host by the -h option,  or  to  an  archive  by  the  -a
              option, the source of performance metrics will be the Performance Metrics Collector
              Daemon (PMCD) on the local host.  The -a and -h options are mutually exclusive.

       -n pmnsfile
              Normally the distributed Performance Metrics Name Space (PMNS) is used, however  if
              the  -n  option  is  specified  an  alternative  local PMNS is loaded from the file
              pmnsfile.

       -s samples
              The argument samples defines the number of samples to be  retrieved  and  reported.
              If  samples  is  0  or  -s is not specified, the application will sample and report
              continuously (in real time mode) or until the end of the PCP  archive  (in  archive
              mode).

       -z     Change  the reporting timezone to the local timezone at the host that is the source
              of the performance metrics, as identified via either the -h or -a options.

       -Z timezone
              By default, applications report the time of day according to the local timezone  on
              the  system  where the application is executed.  The -Z option changes the timezone
              to timezone  in  the  format  of  the  environment  variable  TZ  as  described  in
              environ(5).

INTERVAL SPECIFICATION AND ALIGNMENT

       Most  PCP tools operate with periodic sampling or reporting, and the -t and -A options may
       be used to control the duration of the sample interval and the  alignment  of  the  sample
       times.

       -t interval
              Set the update or reporting interval.

              The  interval  argument  is  specified as a sequence of one or more elements of the
              form
                        number[units]
              where number is an integer or floating point constant (parsed using strtod(3C)) and
              the optional units is one of: seconds, second, secs, sec, s, minutes, minute, mins,
              min, m, hours, hour, h, days, day and d.  If the unit is empty, second is assumed.

              In addition, the upper case (or mixed case) version of any of  the  above  is  also
              acceptable.

              Spaces  anywhere  in  the  interval  are  ignored,  so  4  days 6 hours 30 minutes,
              4day6hour30min, 4d6h30m and 4d6.5h are all equivalent.

              Multiple specifications are additive, e.g. ``1hour 15mins 30secs''  is  interpreted
              as 3600+900+30 seconds.

       -A align
              By default samples are not necessarily aligned on any natural unit of time.  The -A
              option may be used to force the initial sample to be aligned on the boundary  of  a
              natural time unit.  For example -A 1sec, -A 30min and -A 1hour specify alignment on
              whole seconds, half and whole hours respectively.

              The align argument follows the syntax for an interval argument described above  for
              the -t option.

              Note that alignment occurs by advancing the time as required, and that -A acts as a
              modifier to advance both the start of the time window (see the  next  section)  and
              the origin time (if the -O option is specified).

TIME WINDOW SPECIFICATION

       Many  PCP  tools are designed to operate in some time window of interest, e.g. to define a
       termination time for real-time monitoring or to define a start and end time within  a  PCP
       archive log.

       In  the absence of the -O and -A options to specify an initial sample time origin and time
       alignment (see above), the PCP application will retrieve the first sample at the start  of
       the time window.

       The following options may be used to specify a time window of interest.

       -S starttime
              By  default  the  time window commences immediately in real-time mode, or coincides
              with time at the start of the PCP archive log in archive mode.  The -S  option  may
              be used to specify a later time for the start of the time window.

              The starttime parameter may be given in one of three forms (interval is the same as
              for the -t option as described above, ctime is described below):

              interval
                     To specify an offset from the  current  time  (in  real-time  mode)  or  the
                     beginning  of a PCP archive (in archive mode) simply specify the interval of
                     time as the argument.  For example -S 30min will set the start of  the  time
                     window  to  be  exactly 30 minutes from now in real-time mode, or exactly 30
                     minutes from the start of a PCP archive.

              -interval
                     To specify an offset from the end of a PCP archive log, prefix the  interval
                     argument  with  a  minus  sign.   In this case, the start of the time window
                     precedes the time at the end of archive by the given interval.  For  example
                     -S  -1hour  will  set  the  start  of the time window to be exactly one hour
                     before the time of the last sample in a PCP archive log.

              @ctime To specify the calendar date and time (local time in the reporting timezone)
                     for the start of the time window, use the ctime(3C) syntax preceded by an at
                     sign.  For example -S '@ Mon Mar 4 13:07:47 1996'

       -T endtime
              By default the end of the time window is unbounded (in real-time mode)  or  aligned
              with the time at the end of a PCP archive log (in archive mode).  The -T option may
              be used to specify an earlier time for the end of the time window.

              The endtime parameter may be given in one of three forms (interval is the  same  as
              for the -t option as described above, ctime is described below):

              interval
                     To  specify  an  offset  from  the  start  of the time window simply use the
                     interval of time as the argument.  For example -T 2h30m will set the end  of
                     the  time  window  to  be 2 hours and 30 minutes after the start of the time
                     window.

              -interval
                     To specify an offset back from the time at the end of  a  PCP  archive  log,
                     prefix  the  interval  argument with a minus sign.  For example -T -90m will
                     set the end of the time window to be 90 minutes before the time of the  last
                     sample in a PCP archive log.

              @ctime To specify the calendar date and time (local time in the reporting timezone)
                     for the end of the time window, use the ctime(3C) syntax preceded by  an  at
                     sign.  For example -T '@ Mon Mar 4 13:07:47 1996'

       -O origin
              By  default  samples are fetched from the start of the time window (see description
              of -S option) to the end of the time window (see description of -T option).  The -O
              option  allows  the specification of an origin within the time window to be used as
              the initial sample time.  This is useful for interactive use of a PCP tool with the
              pmtime(1) VCR replay facility.

              The origin argument accepted by -O conforms to the same syntax and semantics as the
              starttime argument for the -T option.

              For example -O -0 specifies that the initial position should be at the end  of  the
              time  window;  this  is most useful when wishing to replay ``backwards'' within the
              time window.

       The ctime argument for the -O, -S and -T options is based upon the calendar date and  time
       format  of  ctime(3C),  but  may be a fully specified time string like Mon Mar  4 13:07:47
       1996 or a partially specified time like Mar 4 1996, Mar 4, Mar, 13:07:50 or 13:08.

       For any missing low order fields, the default value of 0 is assumed for hours, minutes and
       seconds,  1 for day of the month and Jan for months.  Hence, the following are equivalent:
       -S '@ Mar 1996' and -S '@ Mar 1 00:00:00 1996'.

       If any high order fields are missing, they are filled in by starting with the year,  month
       and  day  from  the  current time (real-time mode) or the time at the beginning of the PCP
       archive log (archive mode) and advancing the time until it matches  the  fields  that  are
       specified.   So,  for example if the time window starts by default at ``Mon Mar 4 13:07:47
       1996'', then -S @13:10 corresponds to 13:10:00  on  Mon  Mar  4,  1996,  while  -S  @10:00
       corresponds to 10:00:00 on Tue Mar 5, 1996 (note this is the following day).

       For  greater precision than afforded by ctime(3C), the seconds component may be a floating
       point number.

       Also the 12 hour clock (am/pm notation) is supported, so for example 13:07 and 1:07 pm are
       equivalent.

PERFORMANCE METRICS - NAMES AND IDENTIFIERS

       The  number  of performance metric names supported by PCP in IRIX is of the order of a few
       thousand. There are fewer metrics on Linux, but still  a  considerable  number.   The  PCP
       libraries  and  applications  use  an  internal  identification  scheme that unambiguously
       associates a single integer with each known performance metric.  This integer is known  as
       the  Performance  Metric  Identifier,  or PMID.  Although not a requirement, PMIDs tend to
       have global consistency across all systems, so a particular performance metric usually has
       the same PMID.

       For  all users and most applications, direct use of the PMIDs would be inappropriate (e.g.
       this would limit the range of accessible metrics, make the code hard  to  maintain,  force
       the  user  interface  to be particularly baroque, etc.).  Hence a Performance Metrics Name
       Space (PMNS) is used to  provide  external  names  and  a  hierarchic  classification  for
       performance  metrics.   A  PMNS is represented as a tree, with each node having a label, a
       pointer to either a PMID (for leaf nodes) or a set of descendent nodes in  the  PMNS  (for
       non-leaf nodes).

       A  node label must begin with an alphabetic character, followed by zero or more characters
       drawn from the alphabetics, the digits and character  `_ยด  (underscore).   For  alphabetic
       characters in a node label, upper and lower case are distinguished.

       By  convention,  the  name  of a performance metric is constructed by concatenation of the
       node labels on a path through the PMNS from the root node to a leaf node, with a ``.''  as
       a  separator.   The  root node in the PMNS is unlabeled, so all names begin with the label
       associated with one of the descendent  nodes  below  the  root  node  of  the  PMNS,  e.g.
       kernel.percpu.syscall.   Typically  (although this is not a requirement) there would be at
       most one name for each PMID in a PMNS.  For example kernel.all.cpu.idle and  disk.dev.read
       are the unique names for two distinct performance metrics, each with a unique PMID.

       Groups  of  related  PMIDs  may  be named by naming a non-leaf node in the PMNS tree, e.g.
       disk.

       There may be PMIDs with no associated name in a PMNS; this is most likely  to  occur  when
       specific  PMIDs  are  not  available  in all systems, e.g. if ORACLE is not installed on a
       system, there is no good reason to pollute the PMNS with  names  for  all  of  the  ORACLE
       performance metrics.

       Note also that there is no requirement for the PMNS to be the same on all systems, however
       in practice most applications would be developed against a stable PMNS that was assumed to
       be  a  subset  of the PMNS on all systems.  Indeed the PCP distribution includes a default
       local PMNS for just this purpose.

       The default local PMNS  is  located  at  $PCP_VAR_DIR/pmns/root  however  the  environment
       variable  PMNS_DEFAULT may be set to the full pathname of a different PMNS which will then
       be used as the default local PMNS.

       Most applications do not use the local PMNS, but  rather  import  parts  of  the  PMNS  as
       required  from  the same place that performance metrics are fetched, i.e. from pmcd(1) for
       live monitoring or from a PCP archive for retrospective monitoring.

       To explore the PMNS use pminfo(1), or if the PCP GUI package is installed  the  New  Chart
       and Metric Search windows within pmchart(1).

PERFORMANCE METRIC SPECIFICATIONS

       In   configuration   files   and  (to  a  lesser  extent)  command  line  options,  metric
       specifications adhere to the following syntax rules.

       If the source of performance metrics is real-time from pmcd(1) then the accepted syntax is
                 host:metric[instance1,instance2,...]

       If the source of performance metrics is a PCP archive log then the accepted syntax is
                 archive/metric[instance1,instance2,...]

       The host:, archive/ and [instance1,instance2,...]  components are all optional.

       The , delimiter in the list of instance names may be replaced by white space.

       Special characters in instance names may be escaped by  surrounding  the  name  in  double
       quotes or preceding the character with a backslash.

       White space is ignored everywhere except within a quoted instance name.

       An  empty  instance  is  silently  ignored,  and  in  particular  ``[]'' is the same as no
       instance, while ``[one,,,two]'' is parsed as specifying just the two instances ``one'' and
       ``two''.

       As  a  special  case,  if  the  host  is  the single character ``@'' then this refers to a
       PM_CONTEXT_LOCAL source, see pmNewContext(3).

PMCD AND ARCHIVE VERSIONS

       Since PCP version 2,  version  information  has  been  associated  with  pmcd(1)  and  PCP
       archives.  The  version  number  is  used in a number of ways, but most noticeably for the
       distributed pmns(4).  In PCP version 1, the client applications would load the  PMNS  from
       the  default  PMNS  file  but  in  PCP version 2, the client applications extract the PMNS
       information from pmcd(1) or a PCP archive.  Thus in PCP version 2, the version  number  is
       used  to  determine  if  the PMNS to use is from the default local file or from the actual
       current source of the metrics.

PMCD HOSTNAME SPECIFICATION

       Since PCP version 3, the pmcd(1) hostname specification has  been  extended  to  allow  an
       optional  pmcd  port number, and also optional pmproxy(1) hostname and port number.  These
       supercede  (and  override)  the  old-style  PMCD_PORT,   PMPROXY_HOST   and   PMPROXY_PORT
       environment variables.

       The  following  are valid hostname specifications that specify connections to pmcd on host
       nas1.servers.com with/without a list of ports and  with/without  a  pmproxy(1)  connection
       through a firewall.

            $ pcp -h nas1.servers.com:44321,4321@firewall.servers.com:44322
            $ pcp -h nas1.servers.com:44321@firewall.servers.com:44322
            $ pcp -h nas1.servers.com:44321@firewall.servers.com
            $ pcp -h nas1.servers.com@firewall.servers.com
            $ pcp -h nas1.servers.com:44321

ENVIRONMENT

       In  addition  to the PCP run-time environment and configuration variables described in the
       PCP  ENVIRONMENT  section  below,  the  following  environment  variables  apply  to   all
       installations.

       PCP_DERIVED_CONFIG
              When  set,  this  variable  defines the path to a file that contains definitions of
              derived metrics as per the syntax  described  in  pmLoadDerivedConfig(3).   Derived
              metrics  may  be  used  to  extend the available metrics with new (derived) metrics
              using simple arithmetic expressions.

              If  PCP_DERIVED_CONFIG  is  set,  the  derived  metric  definitions  are  processed
              automatically  as  each new source of performance metrics is established (i.e. each
              time a pmNewContext(3) is called) or when requests are made against the PMNS.

       PCP_STDERR
              Many PCP tools support the environment variable PCP_STDERR, which can  be  used  to
              control  where  error  messages are sent.  When unset, the default behavior is that
              ``usage'' messages and option parsing errors are reported on standard error,  other
              messages  after  initial  startup are sent to the default destination for the tool,
              i.e. standard error for ASCII tools, or a dialog for GUI tools.

              If PCP_STDERR is set to the  literal  value  DISPLAY  then  all  messages  will  be
              displayed  in  a  dialog.   This  is used for any tools launched from the a Desktop
              environment.

              If PCP_STDERR is set to any other value, the value is assumed to be a filename, and
              all messages will be written there.

       PCP_USE_STDERR
              This environment variable, previously used by pmlaunch(5), pmgsys(1), pmview(1) and
              the pmview(1) front-end scripts (such as mpvis(1)), has been  deprecated  from  the
              PCP 2.0 release onward and replaced by PCP_STDERR.

       PMCD_CONNECT_TIMEOUT
              When  attempting  to  connect to a remote pmcd(1) on a machine that is booting, the
              connection attempt could potentially block for a long time until the remote machine
              finishes  its  initialization.   Most  PCP applications and some of the PCP library
              routines will abort and return an error if the connection has not been  established
              after  some  specified  interval  has  elapsed.  The default interval is 5 seconds.
              This may be modified by setting PMCD_CONNECT_TIMEOUT in the environment to  a  real
              number  of seconds for the desired timeout.  This is most useful in cases where the
              remote host is at the  end  of  a  slow  network,  requiring  longer  latencies  to
              establish the connection correctly.

       PMCD_RECONNECT_TIMEOUT
              When  a  monitor  or  client  application  loses  a  connection  to  a pmcd(1), the
              connection may be re-established by calling a service routine in the  PCP  library.
              However,  attempts  to  reconnect  are  controlled  by a back-off strategy to avoid
              flooding the network with reconnection requests.  By default, the  back-off  delays
              are  5,  10,  20,  40  and  80 seconds for consecutive reconnection requests from a
              client (the last delay will be repeated for any further attempts after the  fifth).
              Setting  the  environment variable PMCD_RECONNECT_TIMEOUT to a comma separated list
              of  positive  integers  will  re-define   the   back-off   delays,   e.g.   setting
              PMCD_RECONNECT_TIMEOUT  to ``1,2'' will back-off for 1 second, then attempt another
              connection request every 2 seconds thereafter.

       PMCD_REQUEST_TIMEOUT
              For monitor or client applications connected to pmcd(1), there is a possibility  of
              the  application "hanging" on a request for performance metrics or metadata or help
              text.  These delays may become severe if the system running pmcd  crashes,  or  the
              network    connection    is    lost.    By   setting   the   environment   variable
              PMCD_REQUEST_TIMEOUT to a number of seconds, requests to pmcd  will  timeout  after
              this  number  of seconds.  The default behavior is to be willing to wait 10 seconds
              for a response from every pmcd for all applications.

       PMCD_WAIT_TIMEOUT
              When  pmcd(1)  is  started  from  $PCP_RC_DIR/pcp  then  the  primary  instance  of
              pmlogger(1)  will be started if the configuration flag pmlogger is chkconfig'ed on,
              some key applications from the pcp.sw.base subsystem  are  installed  and  pmcd  is
              running and accepting connections.

              The  check  on pmcd's readiness will wait up to PMCD_WAIT_TIMEOUT seconds.  If pmcd
              has a long startup time (such as on a very large  system),  then  PMCD_WAIT_TIMEOUT
              can be set to provide a maximum wait longer than the default 60 seconds.

       PMNS_DEFAULT
              If  set,  then interpreted as the the full pathname to be used as the default local
              PMNS for pmLoadNameSpace(3).  Otherwise, the  default  local  PMNS  is  located  at
              $PCP_VAR_DIR/pcp/pmns/root for base PCP installations.

       PCP_COUNTER_WRAP
              Many  of  the  performance  metrics  exported from PCP agents have the semantics of
              counter meaning they are expected  to  be  monotonically  increasing.   Under  some
              circumstances,  one  value of these metrics may smaller than the previously fetched
              value.  This can happen when a counter of finite precision overflows, or  when  the
              PCP  agent  has  been reset or restarted, or when the PCP agent is exporting values
              from  some  underlying  instrumentation  that  is  subject  to  some   asynchronous
              discontinuity.

              The  environment  variable  PCP_COUNTER_WRAP  may  be set to indicate that all such
              cases of a decreasing ``counter'' should be treated  as  a  counter  overflow,  and
              hence  the  values  are  assumed  to  have  wrapped  once  in  the interval between
              consecutive samples.  This ``wrapping'' behavior was the  default  in  earlier  PCP
              versions, but by default has been disabled in PCP release from version 1.3 on.

       PMDA_PATH
              The  PMDA_PATH  environment  variable may be used to modify the search path used by
              pmcd(1) and pmNewContext(3) (for PM_CONTEXT_LOCAL contexts) when  searching  for  a
              daemon  or  DSO  PMDA.   The  syntax  follows  that for PATH in sh(1), i.e. a colon
              separated   list   of   directories,   and   the    default    search    path    is
              ``/var/pcp/lib:/usr/pcp/lib'',  (or ``/var/lib/pcp/lib'' on Linux, depending on the
              value of the $PCP_VAR_DIR environment variable).

       PMCD_PORT
              The TPC/IP port(s) used by pmcd(1) to create the socket  for  incoming  connections
              and  requests,  was  historically  4321 and more recently the officially registered
              port 44321; in the current release, both port numbers are  used  by  default  as  a
              transitional  arrangement.   This  may  be  over-ridden  by  setting PMCD_PORT to a
              different port number, or a comma-separated list of port numbers.  If a non-default
              port  is used when pmcd is started, then every monitoring application connecting to
              that pmcd must also have PMCD_PORT set in their  environment  before  attempting  a
              connection.

       The  following  environment  variables are relevant to installations in which pmlogger(1),
       the PCP archive logger, is used.

       PMLOGGER_PORT
              The environment variable PMLOGGER_PORT may be used to change the base  TCP/IP  port
              number used by pmlogger(1) to create the socket to which pmlc(1) instances will try
              and connect.  The default base port  number  is  4330.   When  used,  PMLOGGER_PORT
              should be set in the environment before pmlogger is executed.

       PMLOGGER_REQUEST_TIMEOUT
              When  pmlc(1)  connects  to  pmlogger(1),  there  is  a  remote possibility of pmlc
              "hanging" on a request for information as a consequence of a failure of the network
              or  pmlogger.   By  setting  the environment variable PMLOGGER_REQUEST_TIMEOUT to a
              number of seconds, requests to pmlogger will timeout after this number of  seconds.
              The  default  behavior  is  to  be willing to wait forever for a response from each
              request to a pmlogger.  When used, PMLOGGER_REQUEST_TIMEOUT should be  set  in  the
              environment before pmlc is executed.

       If  you  have  the  PCP  product  installed,  then the following environment variables are
       relevant to the Performance Metrics Domain Agents (PMDAs).

       PMDA_LOCAL_PROC
              Use this variable has been deprecated and it is now ignored.  If the ``proc''  PMDA
              is  configured  as  a  DSO  for  use with pmcd(1) on the local host then all of the
              ``proc'' metrics  will  be  available  to  applications  using  a  PM_CONTEXT_LOCAL
              context.

              The  previous  behaviour  was  that  if  this  variable  was  set,  then  a context
              established with the type of PM_CONTEXT_LOCAL will have access to the ``proc'' PMDA
              to retrieve performance metrics about individual processes.

       PMDA_LOCAL_SAMPLE
              Use  this  variable  has  been deprecated and it is now ignored.  If the ``sample''
              PMDA is configured as a DSO for use with pmcd(1) on the local host then all of  the
              ``sample''  metrics  will  be  available  to  applications using a PM_CONTEXT_LOCAL
              context.

              The previous  behaviour  was  that  if  this  variable  was  set,  then  a  context
              established  with  the  type of PM_CONTEXT_LOCAL will have access to the ``sample''
              PMDA if this optional PMDA has been installed locally.

       PMIECONF_PATH
              If set, pmieconf(1) will form its pmieconf(4) specification (set  of  parameterized
              pmie(1) rules) using all valid pmieconf files found below each subdirectory in this
              colon-separated  list  of   subdirectories.    If   not   set,   the   default   is
              $PCP_VAR_DIR/config/pmieconf.

FILES

       /etc/pcp.conf
                 Configuration file for the PCP runtime environment, see pcp.conf(4).
       $PCP_RC_DIR/pcp
                 Script for starting and stopping pmcd(1).
       $PCP_PMCDCONF_PATH
                 Control file for pmcd(1).
       $PCP_PMCDOPTIONS_PATH
                 Command  line options passed to pmcd(1) when it is started from $PCP_RC_DIR/pcp.
                 All the command line option lines should  start  with  a  hyphen  as  the  first
                 character.  This file can also contain environment variable settings of the form
                 "VARIABLE=value".
       $PCP_BINADM_DIR
                 Location of PCP utilities for collecting and maintaining PCP archives, PMDA help
                 text, PMNS files etc.
       $PCP_PMDAS_DIR
                 Parent  directory  of the installation directory for Dynamic Shared Object (DSO)
                 PMDAs.
       $PCP_RUN_DIR/pmcd.pid
                 If pmcd is running, this file contains an ascii decimal  representation  of  its
                 process ID.
       $PCP_LOG_DIR/pmcd
                 Default  location of log files for pmcd(1), current directory for running PMDAs.
                 Archives generated by pmlogger(1) are generally below $PCP_LOG_DIR/pmlogger.
       $PCP_LOG_DIR/pmcd/pmcd.log
                 Diagnostic and status log for the current running pmcd(1)  process.   The  first
                 place to look when there are problems associated with pmcd.
       $PCP_LOG_DIR/pmcd/pmcd.log.prev
                 Diagnostic and status log for the previous pmcd(1) instance.
       $PCP_LOG_DIR/NOTICES
                 Log of pmcd(1) and PMDA starts, stops, additions and removals.
       $PCP_VAR_DIR/config
                 Contains directories of configuration files for several PCP tools.
       $PCP_VAR_DIR/config/pmcd/rc.local
                 Local script for controlling PCP boot, shutdown and restart actions.
       $PCP_VAR_DIR/pmns
                 Directory containing the set of PMNS files for all installed PMDAs.
       $PCP_VAR_DIR/pmns/root
                 The ASCII pmns(4) exported by pmcd(1) by default.  This PMNS is be the super set
                 of all other PMNS files installed in $PCP_VAR_DIR/pmns.
       In addition, if the PCP product is installed  the  following  files  and  directories  are
       relevant.
       $PCP_LOG_DIR/NOTICES
              In addition to the pmcd(1) and PMDA activity, may be used to log alarms and notices
              from pmie(1) via pmpost(1).
       $PCP_PMLOGGERCONTROL_PATH
              Control file for pmlogger(1) instances launched from $PCP_RC_DIR/pcp and/or managed
              by  pmlogger_check(1)  and  pmlogger_daily(1)  as  part of a production PCP archive
              collection setup.

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory
       names used by PCP.  On each installation, the file /etc/pcp.conf contains the local values
       for these variables.  The $PCP_CONF  variable  may  be  used  to  specify  an  alternative
       configuration file, as described in pcp.conf(4).

SEE ALSO

       pmcd(1),  pmie(1),  pmie_daily(1),  pminfo(1),  pmlc(1),  pmlogger(1),  pmlogger_daily(1),
       pmstat(1), pmval(1), pcp(1), pcp.conf(4), pcp.env(4), and pmns(4).

       If the PCP GUI package is installed, then the following entries are also relevant:
       pmchart(1), pmtime(1), and pmdumptext(1).

       Also refer to  the  books  Performance  Co-Pilot  User's  and  Administrator's  Guide  and