Provided by: nut-server_2.6.3-1ubuntu1_amd64 bug

NAME

       oneac - Driver for Oneac UPS equipment

NOTE

       This man page only documents the hardware-specific features of the oneac driver. For
       information about the core driver, see nutupsdrv(8).

SUPPORTED HARDWARE

       This driver supports Oneac EG and ON UPS equipment with the Advanced Interface. If your
       UPS is equipped with the Basic Interface card, use the genericups driver.

EXTRA ARGUMENTS

       This driver supports the following optional settings in the ups.conf(5) file:

       testtime=num
           Change battery test time from the 2 minute default.

INSTANT COMMANDS

       This driver supports the following Instant Commands.

       reset.input.minmax
           Reset the minimum and maximum input line voltage values seen since the last reset or
           power on.

       test.battery.start
           Start a battery test. The default time is 2 minutes. This time can be set in the
           ups.conf file. See testime above.

       test.battery.stop
           Stops a battery test that is in progress.

       test.failure.start
           Starts a 15 second long simulation of an input power failure.

AUTHOR

       Eric Lawson <elawson@inficad.com>

SEE ALSO

   The core driver:
       nutupsdrv(8)

   Internet resources:
       The NUT (Network UPS Tools) home page: http://www.networkupstools.org/