NAME

       Reading/Writing - globus_xio_register_read() semantics:

       If the waitforbytes parameter is greater than zero, the read will happen asynchronously
       and be completed when at least waitforbytes has been read/written.

       If the waitforbytes parameter is equal to zero, one of the following alternative behaviors
       occur:

       If the length of the buffer is > 0 the read happens synchronously. If the user is using
       one of the blocking xio calls, no internal callback will occur.

       If the length of the buffer is also 0, the call behaves like an asynchronous notification
       of data ready to be read. ie, an asynchronous select().

       In any case, when an error occurs before the waitforbytes request has been met, the
       outgoing nbytes is set to the amount of data actually read before the error occurred.

       If the handle is not connected, the user should pass in a data descriptor. After the read,
       this data_descriptor will contain the contact string of the sender. The user can either
       get this contact string with GLOBUS_XIO_UDP_GET_CONTACT or pass the data descriptor
       directly to globus_xio_register_write() to send a message back to the sender.

       Also, if the handle is not connected, the waitforbytes should probably be 1 to guarantee
       that only one packet is received and the sender contact isnt overwritten by multiple
       packets from different senders.

       globus_xio_register_write() semantics:

       When performing a write, exactly one UDP packet is sent of the entire buffer length. The
       waitforbytes parameter is ignored. If the entire buffer can not be written, a
       GLOBUS_XIO_UDP_ERROR_SHORT_WRITE error will be returned with nbytes set to the number of
       bytes actually sent.

       If the handle is not 'connected', a contact string must be set in the data descriptor to
       globus_xio_register_write(). This can either be done explicitly with
       GLOBUS_XIO_UDP_SET_CONTACT or implicitly by passing in a data descriptor received from
       globus_xio_register_read().

       The udp write semantics are always synchronous. No blocking or internal callback will
       occur when using globus_xio_write().