Provided by: units_2.12-2_amd64 bug

NAME

       units — unit conversion and calculation program

SYNOPSIS

       'units' [options] [from-unit [to-unit]]

DESCRIPTION

       The  'units' program converts quantities expressed in various systems of measurement to their equivalents
       in other systems of measurement.  Like many similar programs, it can handle multiplicative scale changes.
       It can also handle nonlinear conversions such as Fahrenheit to Celsius; see Temperature Conversions.  The
       program can also perform conversions from and to sums of units, such as  converting  between  meters  and
       feet plus inches.

       Basic  operation is simple: you enter the units that you want to convert from and the units that you want
       to convert to.  You can use the program interactively with prompts, or you can use it  from  the  command
       line.

       Beyond simple unit conversions, 'units' can be used as a general-purpose scientific calculator that keeps
       track  of  units  in its calculations.  You can form arbitrary complex mathematical expressions of dimen‐
       sions including sums, products, quotients, powers, and even roots of dimensions.   Thus  you  can  ensure
       accuracy and dimensional consistency when working with long expressions that involve many different units
       that may combine in complex ways; for an illustration, see Complicated Unit Expressions.

       The units are defined in an external data file.  You can use the extensive data file that comes with this
       program,  or  you can provide your own data file to suit your needs.  You can also use your own data file
       to supplement the standard data file.

       You can change the default behavior of 'units' with various options given on the command line. See Invok‐
       ing Units for a description of the available options.

INTERACTING WITH UNITS
       To invoke units for interactive use, type 'units' at your shell prompt.  The program will print something
       like this:

          Currency exchange rates from www.timegenie.com on 2014-03-05
          2860 units, 109 prefixes, 85 nonlinear units

          You have:

       At the 'You have:' prompt, type the quantity and units that you are converting from.  For example, if you
       want to convert ten meters to feet, type '10 meters'.  Next, 'units' will print 'You want:'.  You  should
       type  the  units  you  want to convert to.  To convert to feet, you would type 'feet'.  If the 'readline'
       library was compiled in then tab will complete unit names. See  Readline  Support  for  more  information
       about 'readline'.  To quit the program under Unix, press Ctrl-C or Ctrl-D. Under Windows, press Ctrl-C or
       Ctrl-Z; with the latter, you may also need to press Enter.

       The  result will be displayed in two ways.  The first line of output, which is marked with a '*' to indi‐
       cate multiplication, gives the result of the conversion you have asked for.  The second line  of  output,
       which is marked with a '/' to indicate division, gives the inverse of the conversion factor.  If you con‐
       vert 10 meters to feet, 'units' will print

              * 32.808399
              / 0.03048

       which  tells  you  that  10 meters equals about 32.8 feet.  The second number gives the conversion in the
       opposite direction.  In this case, it tells you that 1 foot is equal to about 0.03 dekameters  since  the
       dekameter is 10 meters.  It also tells you that 1/32.8 is about 0.03.

       The  'units' program prints the inverse because sometimes it is a more convenient number.  In the example
       above, for example, the inverse value is an exact conversion: a foot is exactly 0.03048 dekameters.   But
       the number given the other direction is inexact.

       If you convert grains to pounds, you will see the following:

          You have: grains
          You want: pounds
                  * 0.00014285714
                  / 7000

          From the second line of the output you can immediately see that a grain is equal to a seven thousandth
       of  a  pound.   This is not so obvious from the first line of the output.  If you find  the output format
       confusing, try using the '--verbose' option:

          You have: grain
          You want: aeginamina
                  grain = 0.00010416667 aeginamina
                  grain = (1 / 9600) aeginamina

       If you request a conversion between units that measure reciprocal dimensions, then 'units'  will  display
       the conversion results with an extra note indicating that reciprocal conversion has been done:

          You have: 6 ohms
          You want: siemens
                  reciprocal conversion
                  * 0.16666667
                  / 6

       Reciprocal  conversion  can  be suppressed by using the '--strict' option.  As usual, use the '--verbose'
       option to get more comprehensible output:

          You have: tex
          You want: typp
                  reciprocal conversion
                  1 / tex = 496.05465 typp
                  1 / tex = (1 / 0.0020159069) typp

          You have: 20 mph
          You want: sec/mile
                  reciprocal conversion
                  1 / 20 mph = 180 sec/mile
                  1 / 20 mph = (1 / 0.0055555556) sec/mile

       If you enter incompatible unit types, the 'units' program will print a message indicating that the  units
       are not conformable and it will display the reduced form for each unit:

          You have: ergs/hour
          You want: fathoms kg^2 / day
          conformability error
                  2.7777778e-11 kg m^2 / sec^3
                  2.1166667e-05 kg^2 m / sec

       If  you only want to find the reduced form or definition of a unit, simply press Enter at the 'You want:'
       prompt.  Here is an example:

          You have: jansky
          You want:
                  Definition: fluxunit = 1e-26 W/m^2 Hz = 1e-26 kg / s^2

       The output from 'units' indicates that the jansky is defined to be equal to a fluxunit which in  turn  is
       defined  to  be  a  certain combination of watts, meters, and hertz.  The fully reduced (and in this case
       somewhat more cryptic) form appears on the far right.

       Some named units are treated as dimensionless in some situations.  These units  include  the  radian  and
       steradian.   These  units  will  be treated as equal to 1 in units conversions.  Power is equal to torque
       times angular velocity.  This conversion can only be performed if the radian is dimensionless.

          You have: (14 ft lbf) (12 radians/sec)
          You want: watts
                  * 227.77742
                  / 0.0043902509

       It is also possible to compute roots and other non-integer powers of  dimensionless  units;  this  allows
       computations such as the altitude of geosynchronous orbit:

          You have: cuberoot(G earthmass / (circle/siderealday)^2) - earthradius
          You want: miles
                  * 22243.267
                  / 4.4957425e-05

       Named  dimensionless  units  are  not treated as dimensionless in other contexts.  They cannot be used as
       exponents so for example, 'meter^radian' is forbidden.

       If you want a list of options you can type '?'  at the 'You want:' prompt.  The program  will  display  a
       list  of named units that are conformable with the unit that you entered at the 'You have:' prompt above.
       Conformable unit combinations will not appear on this list.

       Typing 'help' at either prompt displays a short help message.  You can also type  'help'  followed  by  a
       unit name.  This will invoke a pager on the units data base at the point where that unit is defined.  You
       can read the definition and comments that may give more details or historical information about the unit.
       (You can generally quit out of the page by pressing 'q'.)

       Typing  'search'  text  will  display  a list of all of the units whose names contain text as a substring
       along with their definitions.  This may help in the case where you aren't sure of the right unit name.

USING UNITS NON-INTERACTIVELY

       The 'units' program can perform units conversions non-interactively from the command line.  To  do  this,
       type the command, type the original unit expression, and type the new units you want.  If a units expres‐
       sion  contains  non-alphanumeric  characters, you may need to protect it from interpretation by the shell
       using single or double quote characters.

       If you type

          units "2 liters" quarts

       then 'units' will print

              * 2.1133764
              / 0.47317647

       and then exit.  The output tells you that 2 liters is about 2.1 quarts, or alternatively that a quart  is
       about 0.47 times 2 liters.

       If  the conversion is successful, then 'units' will return success (zero) to the calling environment.  If
       you enter  non-conformable units then 'units' will print a message giving the reduced form of  each  unit
       and it will return failure (nonzero) to the calling environment.

       When  you  invoke 'units' with only one argument, it will print out the definition of the specified unit.
       It will return failure if the unit is not defined and success if the unit is defined.

UNIT DEFINITIONS

       The conversion information is read from a units data file that is called 'definitions.units' and is  usu‐
       ally  located  in  the '/usr/share/units' directory.  If you invoke 'units' with the '-V' option, it will
       print the location of this file.  The default file includes definitions for all familiar units, abbrevia‐
       tions and metric prefixes.  It also includes many obscure or archaic units.

       Many constants of nature are defined, including these:

          pi          ratio of circumference to diameter
          c           speed of light
          e           charge on an electron
          force       acceleration of gravity
          mole        Avogadro's number
          water       pressure per unit height of water
          Hg          pressure per unit height of mercury
          au          astronomical unit
          k           Boltzman's constant
          mu0         permeability of vacuum
          epsilon0    permittivity of vacuum
          G           Gravitational constant
          mach        speed of sound

       The standard data file includes atomic masses for all of the elements and numerous other constants.  Also
       included are the densities of various ingredients used in baking so that  '2 cups  flour_sifted'  can  be
       converted  to  'grams'.  This is not an exhaustive list.  Consult the units data file to see the complete
       list, or to see the definitions that are used.

       The 'pound' is a unit of mass.  To get force, multiply by the force conversion unit 'force'  or  use  the
       shorthand  'lbf'.   (Note that 'g' is already taken as the standard abbreviation for the gram.)  The unit
       'ounce' is also a unit of mass.  The fluid ounce is 'fluidounce' or 'floz'.  When British capacity  units
       differ  from  their  US  counterparts, such as the British Imperial gallon, the unit is defined both ways
       with 'br' and 'us' prefixes.  Your locale settings will determine the value of the unprefixed unit.  Cur‐
       rency is prefixed with its country name: 'belgiumfranc', 'britainpound'.

       When searching for a unit, if the specified string does not appear exactly  as  a  unit  name,  then  the
       'units'  program  will try to remove a trailing 's', 'es'.  Next units will replace a trailing 'ies' with
       'y'.  If that fails, 'units' will check for a prefix.  The database includes all of the  standard  metric
       prefixes.   Only one prefix is permitted per unit, so 'micromicrofarad' will fail.  However, prefixes can
       appear alone with no unit following them, so 'micro*microfarad' will work, as will 'micro microfarad'.

       To find out which units and prefixes are available, read the standard units data file,  which  is  exten‐
       sively annotated.

   English Customary Units
       English customary units differ in various ways in different regions.  In Britain a complex system of vol‐
       ume  measurements featured different gallons for different materials such as a wine gallon and ale gallon
       that different by twenty percent.  This complexity was swept away in 1824 by a  reform  that  created  an
       entirely  new  gallon, the British Imperial gallon defined as the volume occupied by ten pounds of water.
       Meanwhile in the USA the gallon is derived from the 1707 Winchester  wine  gallon,  which  is  231  cubic
       inches.   These gallons differ by about twenty percent.  By default if 'units' runs in the 'en_GB' locale
       you will get the British volume measures.  If it runs in the 'en_US' locale you will get  the  US  volume
       measures.   In  other  locales the default values are the US definitions.  If you wish to force different
       definitions then set the environment variable 'UNITS_ENGLISH' to either 'US' or 'GB' to set  the  desired
       definitions independent of the locale.

       Before  1959,  the  value of a yard (and other units of measure defined in terms of it) differed slightly
       among English-speaking countries.  In 1959, Australia, Canada,  New  Zealand,  the  United  Kingdom,  the
       United  States,  and  South  Africa  adopted the Canadian value of 1 yard = 0.9144 m (exactly), which was
       approximately halfway between the values used by the UK and the US; it had the  additional  advantage  of
       making  1 inch  =  2.54 cm  (exactly).   This new standard was termed the International Yard.  Australia,
       Canada, and the UK then defined all customary lengths in terms of the International Yard  (Australia  did
       not  define the furlong or rod); because many US land surveys were in terms of the pre-1959 units, the US
       continued to define customary surveyors' units (furlong, chain, rod, and link) in terms of  the  previous
       value for the foot, which was termed the US survey foot.  The US defined a US survey mile as 5280 US sur‐
       vey  feet, and defined a statute mile as a US survey mile.  The US values for these units differ from the
       international values by about 2 ppm.

       The 'units' program uses the international values for these units; the US values can be obtained by using
       either the 'US' or the 'survey' prefix.  In either case, the  simple  familiar  relationships  among  the
       units  are  maintained,  e.g.,  1 'furlong' = 660 'ft', and 1 'USfurlong' = 660 'USft', though the metric
       equivalents differ slightly between the two cases.  The 'US' prefix or the 'survey' prefix  can  also  be
       used  to  obtain  the  US  survey  mile  and  the  value  of the US yard prior to 1959, e.g., 'USmile' or
       'surveymile'  (but  not  'USsurveymile').   To  get  the  US  value  of  the  statute  mile,  use  either
       'USstatutemile' or 'USmile'.

       Except  for  distances  that extend over hundreds of miles (such as in the US State Plane Coordinate Sys‐
       tem), the differences in the miles are usually insignificant:

          You have: 100 surveymile - 100 mile
          You want: inch
                  * 12.672025
                  / 0.078913984

       The pre-1959 UK values for these units can be obtained with the prefix 'UK'.

       In the US, the acre is officially defined in terms of the US survey foot, but 'units' uses  a  definition
       based  on  the  international  foot.   If  you  want  the official US acre use 'USacre' and similarly use
       'USacrefoot' for the official US version of that unit.  The difference between these  units  is  about  4
       parts per million.

UNIT EXPRESSIONS

   Operators
       You can enter more complicated units by combining units with operations such as multiplication, division,
       powers, addition, subtraction, and parentheses for grouping.  You can use the customary symbols for these
       operators  when  'units' is invoked with its default options.  Additionally, 'units' supports some exten‐
       sions, including high priority multiplication using a space, and a high priority numerical division oper‐
       ator ('|') that can simplify some expressions.

       You multiply units using a space or an asterisk ('*').  The next example shows both forms:

          You have: arabicfoot * arabictradepound * force
          You want: ft lbf
                  * 0.7296
                  / 1.370614

       You can divide units using the slash ('/') or with 'per':

          You have: furlongs per fortnight
          You want: m/s
                  * 0.00016630986
                  / 6012.8727

       You can use parentheses for grouping:

          You have: (1/2) kg / (kg/meter)
          You want: league
                  * 0.00010356166
                  / 9656.0833

       Multiplication using a space has a higher precedence than division using a slash and is evaluated left to
       right; in effect, the first '/' character marks the beginning of the denominator of  a  unit  expression.
       This makes it simple to enter a quotient with several terms in the denominator: 'J / mol K'.  The '*' and
       '/'  operators  have  the same precedence, and are evaluated left to right; if you multiply with '*', you
       must group the terms in the denominator with parentheses: 'J / (mol * K)'.

       The higher precedence of the space operator may not always be advantageous.  For example, 'm/s s/day'  is
       equivalent  to  'm / s s day' and has dimensions of length per time cubed.  Similarly, '1/2 meter' refers
       to a unit of reciprocal length equivalent to 0.5/meter, perhaps not what you would intend if you  entered
       that  expression.  The get a half meter you would need to use parentheses: '(1/2) meter'.  The '*' opera‐
       tor is convenient for multiplying a sequence of quotients.  For example, 'm/s * s/day' is  equivalent  to
       'm/day'.  Similarly, you could write '1/2 * meter' to get half a meter.

       The 'units' program supports another option for numerical fractions: you can indicate division of numbers
       with  the  vertical bar ('|'), so if you wanted half a meter you could write '1|2 meter'.  You cannot use
       the vertical bar to indicate division of non-numerical units (e.g., 'm|s' results in an error message).

       Powers of units can be specified using the '^' character, as shown in the following example, or by simple
       concatenation of a unit and its exponent: 'cm3' is equivalent to 'cm^3'; if the exponent is more than one
       digit, the '^' is required.  You can also use '**' as an exponent operator.

          You have: cm^3
          You want: gallons
                  * 0.00026417205
                  / 3785.4118

       Concatenation only works with a single unit name: if you write '(m/s)2', 'units' will treat it as  multi‐
       plication  by  2.   When  a  unit  includes  a  prefix,  exponent  operators apply to the combination, so
       'centimeter3' gives cubic centimeters.  If you separate the prefix from the unit with any  multiplication
       operator  (e.g., 'centi meter^3'), the prefix is treated as a separate unit, so the exponent applies only
       to the unit without the prefix.  The second example is equivalent to 'centi *  (meter^3)',  and  gives  a
       hundredth  of  a cubic meter, not a cubic centimeter.  The 'units' program is limited internally to prod‐
       ucts of 99 units; accordingly, expressions like 'meter^100'  or  'joule^34'  (represented  internally  as
       'kg^34 m^68 / s^68') will fail.

       The '|' operator has the highest precedence, so you can write the square root of two thirds as '2|3^1|2'.
       The '^' operator has the second highest precedence, and is evaluated right to left, as usual:

          You have: 5 * 2^3^2
          You want:
                  Definition: 2560

       With  a  dimensionless base unit, any dimensionless exponent is meaningful (e.g., 'pi^exp(2.371)').  Even
       though angle is sometimes treated as dimensionless, exponents cannot have dimensions of angle:

          You have: 2^radian
                           ^
          Exponent not dimensionless

       If the base unit is not dimensionless, the exponent must be a rational number p/q, and the  dimension  of
       the  unit  must be a power of q, so 'gallon^2|3' works but 'acre^2|3' fails.  An exponent using the slash
       ('/') operator (e.g., 'gallon^(2/3)') is also acceptable; the parentheses are needed because  the  prece‐
       dence  of  '^'  is  higher  than  that  of '/'.  Since 'units' cannot represent dimensions with exponents
       greater than 99, a fully reduced exponent must have q < 100.  When raising a non-dimensionless unit to  a
       power,  'units' attempts to convert a decimal exponent to a rational number with q < 100.  If this is not
       possible 'units' displays an error message:

          You have: ft^1.234
          Base unit not dimensionless; rational exponent required

       A decimal exponent must match its rational representation to machine precision, so 'acre^1.5'  works  but
       'gallon^0.666' does not.

   Sums and Differences of Units
       You  may  sometimes  want to add values of different units that are outside the SI.  You may also wish to
       use 'units' as a calculator that keeps track of units.  Sums of conformable units are  written  with  the
       '+' character, and differences with the '-' character.

          You have: 2 hours + 23 minutes + 32 seconds
          You want: seconds
                  * 8612
                  / 0.00011611705

          You have: 12 ft + 3 in
          You want: cm
                  * 373.38
                  / 0.0026782366

          You have: 2 btu + 450 ft lbf
          You want: btu
                  * 2.5782804
                  / 0.38785542

       The  expressions that are added or subtracted must reduce to identical expressions in primitive units, or
       an error message will be displayed:

          You have: 12 printerspoint - 4 heredium
                                                ^
          Illegal sum of non-conformable units

       As usual, the precedence for '+' and '-' is lower than that of the other operators.  A  fractional  quan‐
       tity such as 2 1/2 cups can be given as '(2+1|2) cups'; the parentheses are necessary because multiplica‐
       tion  has  higher precedence than addition.  If you omit the parentheses, 'units' attempts to add '2' and
       '1|2 cups', and you get an error message:

          You have: 2+1|2 cups
                             ^
          Illegal sum or difference of non-conformable units

       The expression could also be correctly written as '(2+1/2) cups'.  If you write '2 1|2 cups' the space is
       interpreted as multiplication so the result is the same as '1 cup'.

       The '+' and '-' characters sometimes appears in exponents like '3.43e+8'.  This leads to an ambiguity  in
       an expression like '3e+2 yC'.  The unit 'e' is a small unit of charge, so this can be regarded as equiva‐
       lent  to '(3e+2) yC' or '(3 e)+(2 yC)'.  This ambiguity is resolved by always interpreting '+' and '-' as
       part of an exponent if possible.

   Numbers as Units
       For 'units', numbers are just another kind of unit.  They can appear as many times as you like and in any
       order in a unit expression.  For example, to find the volume of a box that is 2 ft by 3 ft by  12  ft  in
       steres, you could do the following:

          You have: 2 ft 3 ft 12 ft
          You want: stere
                  * 2.038813
                  / 0.49048148

          You have: $ 5 / yard
          You want: cents / inch
                  * 13.888889
                  / 0.072

       And  the second example shows how the dollar sign in the units conversion can precede the five.  Be care‐
       ful: 'units' will interpret '$5' with no space as equivalent to 'dollar^5'.

   Built-in Functions
       Several built-in functions are provided: 'sin', 'cos', 'tan', 'ln', 'log', 'log2', 'exp', 'acos',  'atan'
       and 'asin'.  The 'sin', 'cos', and 'tan' functions require either a dimensionless argument or an argument
       with dimensions of angle.

          You have: sin(30 degrees)
          You want:
                  Definition: 0.5

          You have: sin(pi/2)
          You want:
                  Definition: 1

          You have: sin(3 kg)
                            ^
          Unit not dimensionless

       The  other  functions  on  the list require dimensionless arguments.  The inverse trigonometric functions
       return arguments with dimensions of angle.

       If you wish to take roots of units, you may use the 'sqrt'  or  'cuberoot'  functions.   These  functions
       require  that  the  argument  have the appropriate root.  You can obtain higher roots by using fractional
       exponents:

          You have: sqrt(acre)
          You want: feet
                  * 208.71074
                  / 0.0047913202

          You have: (400 W/m^2 / stefanboltzmann)^(1/4)
          You have:
                  Definition: 289.80882 K

          You have: cuberoot(hectare)
                                    ^
          Unit not a root

   Previous Result
       You can insert the result of the previous conversion using the underscore ('_').  It is useful  when  you
       want to convert the same input to several different units, for example

          You have: 2.3 tonrefrigeration
          You want: btu/hr
                  * 27600
                  / 3.6231884e-005
          You have: _
          You want: kW
                  * 8.0887615
                  / 0.12362832

       Suppose  you  want to do some deep frying that requires an oil depth of 2 inches.  You have 1/2 gallon of
       oil, and want to know the largest-diameter pan that will maintain the required depth.  The nonlinear unit
       'circlearea' gives the radius of the circle (see Other Nonlinear Units, for a more detailed  description)
       in SI units; you want the diameter in inches:

          You have: 1|2 gallon / 2 in
          You want: circlearea
                  0.10890173 m

          You have: 2 _
          You want: in
                  * 8.5749393
                  / 0.1166189

       In most cases, surrounding white space is optional, so the previous example could have used '2_'.  If '_'
       follows a non-numerical unit symbol, however, the space is required:

          You have: m_
                     ^
          Parse error

       When  '_'  is  followed  by  a digit, the operation is multiplication rather than exponentiation, so that
       '_2', is equivalent to '_ * 2' rather than '_^2'.

       You can use the '_' symbol any number of times; for example,

          You have: m
          You want:
                  Definition: 1 m
          You have: _ _
          You want:
                  Definition: 1 m^2

       Using '_' before a conversion has been performed (e.g., immediately after invocation) generates an error:

          You have: _
                    ^
          No previous result; '_' not set

       Accordingly, '_' serves no purpose when 'units' is invoked non-interactively.

       If 'units' is invoked with the '--verbose' option (see Invoking Units), the value of '_' is not expanded:

          You have: mile
          You want: ft
                  mile = 5280 ft
                  mile = (1 / 0.00018939394) ft
          You have: _
          You want: m
                  _ = 1609.344 m
                  _ = (1 / 0.00062137119) m

       You can give '_' at the 'You want:' prompt, but it usually is not very useful.

   Complicated Unit Expressions
       The 'units' program is especially helpful in ensuring accuracy and dimensional consistency when  convert‐
       ing lengthy unit expressions.  For example, one form of the Darcy-Weisbach fluid-flow equation is

            Delta P = (8 / pi)^2 (rho fLQ^2) / d^5,

       where  Delta P is the pressure drop, rho is the mass density, f is the (dimensionless) friction factor, L
       is the length of the pipe, Q is the volumetric flow rate, and d  is  the  pipe  diameter.   It  might  be
       desired to have the equation in the form

            Delta P = A1 rho fLQ^2 / d^5

       that accepted the user's normal units; for typical units used in the US, the required conversion could be
       something like

          You have: (8/pi^2)(lbm/ft^3)ft(ft^3/s)^2(1/in^5)
          You want: psi
                  * 43.533969
                  / 0.022970568

       The  parentheses  allow individual terms in the expression to be entered naturally, as they might be read
       from the formula.  Alternatively, the multiplication could be done with the '*' rather than a space; then
       parentheses are needed only around 'ft^3/s' because of its exponent:

          You have: 8/pi^2 * lbm/ft^3 * ft * (ft^3/s)^2 /in^5
          You want: psi
                  * 43.533969
                  / 0.022970568

       Without parentheses, and using spaces for multiplication,  the  previous  conversion  would  need  to  be
       entered as

          You have: 8 lb ft ft^3 ft^3 / pi^2 ft^3 s^2 in^5
          You want: psi
                  * 43.533969
                  / 0.022970568

   Backwards Compatibility:
       '*'  and  '-'  The  original  'units' assigned multiplication a higher precedence than division using the
       slash.  This differs from the usual precedence rules, which give multiplication and division equal prece‐
       dence, and can be confusing for people who think of units as a calculator.

       The star operator ('*') included in this 'units' program has, by default, the same  precedence  as  divi‐
       sion,  and  hence follows the usual precedence rules.  For backwards compatibility you can invoke 'units'
       with the '--oldstar' option.  Then '*' has a higher precedence than division, and the same precedence  as
       multiplication using the space.

       Historically, the hyphen ('-') has been used in technical publications to indicate products of units, and
       the  original  'units' program treated it as a multiplication operator.  Because 'units' provides several
       other ways to obtain unit products, and because '-'  is  a  subtraction  operator  in  general  algebraic
       expressions,  'units' treats the binary '-' as a subtraction operator by default.  For backwards compati‐
       bility use the '--product' option, which causes 'units' to treat the binary '-'  operator  as  a  product
       operator.   When  '-'  is  a  multiplication operator it has the same precedence as multiplication with a
       space, giving it a higher precedence than division.

       When '-' is used as a unary operator it negates its operand.  Regardless of the 'units' options,  if  '-'
       appears  after  '('  or  after '+' then it will act as a negation operator.  So you can always compute 20
       degrees minus 12 minutes by entering '20 degrees + -12 arcmin'.  You must use this construction when  you
       define new units because you cannot know what options will be in force when your definition is processed.

NONLINEAR UNIT CONVERSIONS

       Nonlinear units are represented using functional notation.  They make possible nonlinear unit conversions
       such as temperature.

   Temperature Conversions
       Conversions between temperatures are different from linear conversions between temperature increments—see
       the  example  below.  The absolute temperature conversions are handled by units starting with 'temp', and
       you must use functional notation.  The temperature-increment conversions are done  using  units  starting
       with 'deg' and they do not require functional notation.

          You have: tempF(45)
          You want: tempC
                  7.2222222

          You have: 45 degF
          You want: degC
                  * 25
                  / 0.04

       Think  of  'tempF(x)'  not  as  a  function  but as a notation that indicates that x should have units of
       'tempF' attached to it.  See Defining Nonlinear Units.  The  first  conversion  shows  that  if  it's  45
       degrees  Fahrenheit  outside, it's 7.2 degrees Celsius.  The second conversion indicates that a change of
       45 degrees Fahrenheit corresponds to a change of 25 degrees Celsius.  The conversion from  'tempF(x)'  is
       to absolute temperature, so that

          You have: tempF(45)
          You want: degR
                  * 504.67
                  / 0.0019814929

       gives the same result as

          You have: tempF(45)
          You want: tempR
                  * 504.67
                  / 0.0019814929

       But if you convert 'tempF(x)' to 'degC', the output is probably not what you expect:

          You have: tempF(45)
          You want: degC
                  * 280.37222
                  / 0.0035666871

       The result is the temperature in K, because 'degC' is defined as 'K', the Kelvin. For consistent results,
       use the 'tempX' units when converting to a temperature rather than converting a temperature increment.

       The 'tempC()' and 'tempF()' definitions are limited to positive absolute temperatures, and giving a value
       that would result in a negative absolute temperature generates an error message:

          You have: tempC(-275)
                              ^
          Argument of function outside domain
                              ^

   Other Nonlinear Units
       Some  other examples of nonlinear units are numerous different ring sizes and wire gauges, the grit sizes
       used for abrasives, the decibel scale, shoe size, scales for the density of  sugar  (e.g.,  baume).   The
       standard  data  file  also  supplies units for computing the area of a circle and the volume of a sphere.
       See the standard units data file for more details.  Wire gauges with multiple zeroes are signified  using
       negative numbers where two zeroes is '-1'.  Alternatively, you can use the synonyms 'g00', 'g000', and so
       on that are defined in the standard units data file.

          You have: wiregauge(11)
          You want: inches
                  * 0.090742002
                  / 11.020255

          You have: brwiregauge(g00)
          You want: inches
                  * 0.348
                  / 2.8735632

          You have: 1 mm
          You want: wiregauge
                  18.201919

          You have: grit_P(600)
          You want: grit_ansicoated
                  342.76923

       The last example shows the conversion from P graded sand paper, which is the European standard and may be
       marked ``P600'' on the back, to the USA standard.

       You  can compute the area of a circle using the nonlinear unit, 'circlearea'.  You can also do this using
       the circularinch or circleinch.  The next example shows two ways to compute the area of a circle  with  a
       five inch radius and one way to compute the volume of a sphere with a radius of one meter.

          You have: circlearea(5 in)
          You want: in2
                  * 78.539816
                  / 0.012732395

          You have: 10^2 circleinch
          You want: in2
                  * 78.539816
                  / 0.012732395

          You have: spherevol(meter)
          You want: ft3
                  * 147.92573
                  / 0.0067601492

       The inverse of a nonlinear conversion is indicated by prefixing a tilde ('~') to the nonlinear unit name:

          You have: ~wiregauge(0.090742002 inches)
          You want:
                  Definition: 11

       You  can  give  a  nonlinear  unit  definition without an argument or parentheses, and press Enter at the
       'You want:' prompt to get the definition of a nonlinear unit; if the definition is not valid for all real
       numbers, the range of validity is also given.  If the definition requires specific units this information
       is also displayed:

          You have: tempC
                  Definition: tempC(x) = x K + stdtemp
                              defined for x >= -273.15
          You have: ~tempC
                  Definition: ~tempC(tempC) = (tempC +(-stdtemp))/K
                              defined for tempC >= 0 K
          You have: circlearea
                  Definition: circlearea(r) = pi r^2
                              r has units m

       To see the definition of the inverse use the '~' notation.  In this case the parameter in the  functional
       definition  will  usually  be  the  name  of  the  unit.  Note that the inverse for 'tempC' shows that it
       requires units of 'K' in the specification of the allowed range of values.   Nonlinear  unit  conversions
       are described in more detail in Defining Nonlinear Units.

UNIT LISTS: CONVERSION TO SUMS OF UNITS

       Outside of the SI, it is sometimes desirable to convert a single unit to a sum of units—for example, feet
       to  feet  plus inches.  The conversion from sums of units was described in Sums and Differences of Units,
       and is a simple matter of adding the units with the '+' sign:

          You have: 12 ft + 3 in + 3|8 in
          You want: ft
                  * 12.28125
                  / 0.081424936

       Although you can similarly write a sum of units to convert to, the result will not be the  conversion  to
       the units in the sum, but rather the conversion to the particular sum that you have entered:

          You have: 12.28125 ft
          You want: ft + in + 1|8 in
                  * 11.228571
                  / 0.089058524

       The  unit  expression given at the 'You want:' prompt is equivalent to asking for conversion to multiples
       of '1 ft + 1 in + 1|8 in', which is 1.09375 ft, so the conversion in the previous example  is  equivalent
       to

          You have: 12.28125 ft
          You want: 1.09375 ft
                  * 11.228571
                  / 0.089058524

       In  converting  to  a  sum  of units like miles, feet and inches, you typically want the largest integral
       value for the first unit, followed by the largest integral value for the next,  and  the  remainder  con‐
       verted to the last unit.  You can do this conversion easily with 'units' using a special syntax for lists
       of  units.  You must list the desired units in order from largest to smallest, separated by the semicolon
       (';') character:

          You have: 12.28125 ft
          You want: ft;in;1|8 in
                  12 ft + 3 in + 3|8 in

       The conversion always gives integer coefficients on the units in the list, except possibly the last  unit
       when the conversion is not exact:

          You have: 12.28126 ft
          You want: ft;in;1|8 in
                  12 ft + 3 in + 3.00096 * 1|8 in

       The order in which you list the units is important:

          You have: 3 kg
          You want: oz;lb
                  105 oz + 0.051367866 lb

          You have: 3 kg
          You want: lb;oz
                  6 lb + 9.8218858 oz

       Listing  ounces before pounds produces a technically correct result, but not a very useful one.  You must
       list the units in descending order of size in order to get the most useful result.

       Ending a unit list with the separator ';' has the same effect as repeating the last unit on the list,  so
       'ft;in;1|8 in;' is equivalent to 'ft;in;1|8 in;1|8 in'.  With the example above, this gives

          You have: 12.28126 ft
          You want: ft;in;1|8 in;
                  12 ft + 3 in + 3|8 in + 0.00096 * 1|8 in

       in  effect  separating  the  integer  and  fractional parts of the coefficient for the last unit.  If you
       instead prefer to round the last coefficient to an integer you can do  this  with  the  '--round'  ('-r')
       option.  With the previous example, the result is

          You have: 12.28126 ft
          You want: ft;in;1|8 in
                  12 ft + 3 in + 3|8 in (rounded down to nearest 1|8 in)

       When  you use the '-r' option, repeating the last unit on the list has no effect (e.g., 'ft;in;1|8 in;1|8
       in' is equivalent to 'ft;in;1|8 in'), and hence neither does ending a list with a  ';'.   With  a  single
       unit  and the '-r' option, a terminal ';' does have an effect: it causes 'units' to treat the single unit
       as a list and produce a rounded value for the single unit.  Without the extra ';', the '-r' option has no
       effect on single unit conversions.  This example shows the output using the '-r' option:

          You have: 12.28126 ft
          You want: in
                  * 147.37512
                  / 0.0067854058

          You have: 12.28126 ft
          You want: in;
                  147 in (rounded down to nearest in)

       Each unit that appears in the list must be conformable with the first unit on the list, and of course the
       listed units must also be conformable with the unit that you enter at the 'You have:' prompt.

          You have: meter
          You want: ft;kg
                       ^
          conformability error
                  ft = 0.3048 m
                  kg = 1 kg

          You have: meter
          You want: lb;oz
          conformability error
                  1 m
                  0.45359237 kg

       In the first case, 'units' reports the disagreement between units appearing on the list.  In  the  second
       case,  'units'  reports  disagreement between the unit you entered and the desired conversion.  This con‐
       formability error is based on the first unit on the unit list.

       Other common candidates for conversion to sums of units are angles and time:

          You have: 23.437754 deg
          You want; deg;arcmin;arcsec
              23 deg + 26 arcmin + 15.9144 arcsec

          You have: 7.2319 hr
          You want: hr;min;sec
              7 hr + 13 min + 54.84 sec

       In North America, recipes for cooking typically measure ingredients by volume, and use units that are not
       always convenient multiples of each other.  Suppose that you have a recipe for 6 and you wish to  make  a
       portion  for 1.  If the recipe calls for 2 1/2 cups of an ingredient, you might wish to know the measure‐
       ments in terms of measuring devices you have available, you could use 'units' and enter

          You have: (2+1|2) cup / 6
          You want: cup;1|2 cup;1|3 cup;1|4 cup;tbsp;tsp;1|2 tsp;1|4 tsp
                  1|3 cup + 1 tbsp + 1 tsp

       By default, if a unit in a list begins with fraction of the form 1|x and its multiplier  is  an  integer,
       the fraction is given as the product of the multiplier and the numerator; for example,

          You have: 12.28125 ft
          You want: ft;in;1|8 in;
                  12 ft + 3 in + 3|8 in

       In  many cases, such as the example above, this is what is wanted, but sometimes it is not.  For example,
       a cooking recipe for 6 might call for 5 1/4 cup of an ingredient, but you want a portion for 2, and  your
       1-cup measure is not available; you might try

          You have: (5+1|4) cup / 3
          You want: 1|2 cup;1|3 cup;1|4 cup
                  3|2 cup + 1|4 cup

       This  result  might be fine for a baker who has a 1 1/2-cup measure (and recognizes the equivalence), but
       it may not be as useful to someone with more limited set of measures, who does want to do additional cal‐
       culations, and only wants to know ``How many 1/2-cup measures to I need to add?''  After all, that's what
       was actually asked.  With the '--show-factor' option, the factor will not be combined with a unity numer‐
       ator, so that you get

          You have: (5+1|4) cup / 3
          You want: 1|2 cup;1|3 cup;1|4 cup
                  3 * 1|2 cup + 1|4 cup

       A user-specified fractional unit with a numerator other than 1 is never  overridden,  however—if  a  unit
       list specifies '3|4 cup;1|2 cup', a result equivalent to 1 1/2 cups will always be shown as '2 * 3|4 cup'
       whether or not the '--show-factor' option is given.

       Some  applications  for unit lists may be less obvious.  Suppose that you have a postal scale and wish to
       ensure that it's accurate at 1 oz, but have only metric calibration weights.  You might try

          You have: 1 oz
          You want: 100 g;50 g; 20 g;10 g;5 g;2 g;1 g;
                  20 g + 5 g + 2 g + 1 g + 0.34952312 * 1 g

       You might then place one each of the 20 g, 5 g, 2 g, and 1 g weights on the scale and hope that it  indi‐
       cates close to

          You have: 20 g + 5 g + 2 g + 1 g
          You want: oz;
                  0.98767093 oz

       Appending  ';'  to  'oz'  forces  a one-line display that includes the unit; here the integer part of the
       result is zero, so it is not displayed.

       A unit list such as

          cup;1|2 cup;1|3 cup;1|4 cup;tbsp;tsp;1|2 tsp;1|4 tsp

       can be tedious to enter.  The 'units' program provides shorthand names for some common combinations:

          hms         hours, minutes, seconds
          dms         angle: degrees, minutes, seconds
          time        years, days, hours, minutes and seconds
          usvol       US cooking volume: cups and smaller

       Using these shorthands, or unit list aliases, you can do the following conversions:

          You have: anomalisticyear
          You want: time
                  1 year + 25 min + 3.4653216 sec
          You have: 1|6 cup
          You want: usvol
                  2 tbsp + 2 tsp

       You cannot combine a unit list alias with other units: it must appear alone at the 'You want:' prompt.

       You can display the definition of a unit list alias by entering it at the 'You have:' prompt:

          You have: dms
                  Definition: unit list, deg;arcmin;arcsec

       When you specify compact output with '--compact', '--terse' or '-t' and  perform  conversion  to  a  unit
       list, 'units' lists the conversion factors for each unit in the list, separated by semicolons.

          You have: year
          You want: day;min;sec
          365;348;45.974678

       Unlike the case of regular output, zeros are included in this output list:

          You have: liter
          You want: cup;1|2 cup;1|4 cup;tbsp
          4;0;0;3.6280454

LOGGING CALCULATIONS

       The  '--log'  option  allows you to save the results of calculations in a file; this can be useful if you
       need a permanent record of your work.  For example, the fluid-flow conversion in Complicated Unit Expres‐
       sions, is lengthy, and if you were to use it in designing a piping system, you might want a record of  it
       for the project file.  If the interactive session

          # Conversion factor A1 for pressure drop
          # dP = A1 rho f L Q^2/d^5
          You have: (8/pi^2) (lbm/ft^3)ft(ft^3/s)^2(1/in^5) # Input units
          You want: psi
                  * 43.533969
                  / 0.022970568

       were logged, the log file would contain

          ### Log started Fri Oct 02 15:55:35 2015

          # Conversion factor A1 for pressure drop
          # dP = A1 rho f L Q^2/d^5
          From: (8/pi^2) (lbm/ft^3)ft(ft^3/s)^2(1/in^5)   # Input units
          To:   psi
                  * 43.533969
                  / 0.022970568

       The time is written to the log file when the file is opened.

       The use of comments can help clarify the meaning of calculations for the log.  The log includes conforma‐
       bility errors between the units at the 'You have:' and 'You want:' prompts, but not other errors, includ‐
       ing lack of conformability of items in sums or differences or among items in a unit list.  For example, a
       conversion between zenith angle and elevation angle could involve

          You have: 90 deg - (5 deg + 22 min + 9 sec)
                                             ^
          Illegal sum or difference of non-conformable units
          You have: 90 deg - (5 deg + 22 arcmin + 9 arcsec)
          You want: dms
                  84 deg + 37 arcmin + 51 arcsec
          You have: _
          You want: deg
                  * 84.630833
                  / 0.011816024
          You have:

       The log file would contain

          From: 90 deg - (5 deg + 22 arcmin + 9 arcsec)
          To:   deg;arcmin;arcsec
                  84 deg + 37 arcmin + 51 arcsec
          From: _
          To:   deg
                  * 84.630833
                  / 0.011816024

       The initial entry error (forgetting that minutes have dimension of time, and that arcminutes must be used
       for  dimensions  of  angle) does not appear in the output.  When converting to a unit list alias, 'units'
       expands the alias in the log file.

       The 'From:' and 'To:' tags are written to the log file even if the '--quiet' option is given.  If the log
       file exists when 'units' is invoked, the new results are appended to the log file.  The time  is  written
       to  the  log  file each time the file is opened.  The '--log' option is ignored when 'units' is used non-
       interactively.

INVOKING UNITS
       You invoke 'units' like this:

          units [options] [from-unit [to-unit]]

       If the from-unit and to-unit are omitted, the program will use interactive  prompts  to  determine  which
       conversions  to  perform.   See  Interactive  Use.  If both from-unit and to-unit are given, 'units' will
       print the result of that single conversion and then exit.  If only from-unit appears on the command line,
       'units' will display the definition of that unit and exit.  Units specified on the command line may  need
       to be quoted to protect them from shell interpretation and to group them into two arguments.  See Command
       Line Use.

       The  default  behavior  of  'units' can be changed by various options given on the command line.  In most
       cases, the options may be given in either short form (a single '-' followed by  a  single  character)  or
       long  form  ('--'  followed  by  a  word  or hyphen-separated words).  Short-form options are cryptic but
       require less typing; long-form options require more typing but are  more  explanatory  and  may  be  more
       mnemonic.   With  long-form  options  you  need only enter sufficient characters to uniquely identify the
       option to the program.  For example, '--out %f' works, but '--o %f' fails because 'units' has other  long
       options  beginning  with  'o'.   However, '--q' works because '--quiet' is the only long option beginning
       with 'q'.

       Some options require arguments to specify a value (e.g., '-d 12' or '--digits 12').   Short-form  options
       that  do  not  take  arguments  may  be concatenated (e.g., '-erS' is equivalent to '-e -r -S'); the last
       option in such a list may be one that takes an argument (e.g., '-ed 12').  With short-form  options,  the
       space  between an option and its argument is optional (e.g., '-d12' is equivalent to '-d 12').  Long-form
       options may not be concatenated, and the space between a long-form option and its argument  is  required.
       Short-form  and  long-form  options  may  be intermixed on the command line.  Options may be given in any
       order, but when incompatible options (e.g., '--output-format' and '--exponential') are given in  combina‐
       tion,  behavior is controlled by the last option given.  For example, '-o%.12f -e' gives exponential for‐
       mat with the default eight significant digits).

       The following options are available:

       -c, --check
              Check that all units and prefixes defined in the units data file reduce to primitive units.  Print
              a list of all units that cannot be reduced.  Also display some other diagnostics about  suspicious
              definitions  in  the  units data file.  Only definitions active in the current locale are checked.
              You should always run 'units' with this option after modifying a units data file.

       --check-verbose, --verbose-check
              Like the '--check' option, this option prints a list of units that cannot be reduced.  But to help
              find unit  definitions that cause endless loops, it lists the  units  as  they  are  checked.   If
              'units'  hangs, then the last unit to be printed has a bad definition.  Only definitions active in
              the current locale are checked.

       -d ndigits, --digits ndigits
              Set the number of significant digits in the output to the value specified (which must  be  greater
              than  zero).   For example, '-d 12' sets the number of significant digits to 12.  With exponential
              output 'units' displays one digit to the left of the decimal point and eleven digits to the  right
              of  the decimal point.  On most systems, the maximum number of internally meaningful digits is 15;
              if you specify a greater number than your system's maximum, 'units' will print a warning  and  set
              the  number  to the largest meaningful value.  To directly set the maximum value, give an argument
              of 'max' (e.g., '-d max').  Be aware, of course, that ``significant'' here refers only to the dis‐
              play of numbers; if results depend on physical constants not known to this precision,  the  physi‐
              cally  meaningful precision may be less than that shown.  The '--digits' option conflicts with the
              '--output-format' option.

       -e, --exponential
              Set the numeric output format to exponential (i.e., scientific notation), like that  used  in  the
              Unix  'units'  program.   The  default  precision is eight significant digits (seven digits to the
              right of the decimal point); this can be changed with the '--digits' option.  The  '--exponential'
              option conflicts with the '--output-format' option.

       -o format, --output-format format
              This  option  affords  complete control over the numeric output format using the specified format.
              The format is a single floating point  numeric  format  for  the  'printf()'  function  in  the  C
              programming  language.   All compilers support the format types 'g' and 'G' to specify significant
              digits, 'e' and 'E' for scientific notation, and 'f' for fixed-point decimal.  The ISO  C99  stan‐
              dard  introduced  the  'F'  type for fixed-point decimal and the 'a' and 'A' types for hexadecimal
              floating point; these types are allowed with compilers that support them.  The default  format  is
              '%.8g';  for  greater  precision, you could specify '-o %.15g'.  See Numeric Output Format and the
              documentation for 'printf()' for more detailed descriptions  of  the  format  specification.   The
              '--output-format'  option  affords  the greatest control of the output appearance, but requires at
              least rudimentary knowledge of the 'printf()' format syntax.  If you don't want to bother with the
              'printf()' syntax, you can specify greater precision more simply with  the  '--digits'  option  or
              select exponential format with '--exponential'.  The '--output-format' option is incompatible with
              the '--exponential' and '--digits' options.

       -f filename, --file filename
              Instruct  'units'  to  load  the units file filename.  You can specify up to 25 units files on the
              command line.  When you use this option, 'units' will load only the files you list on the  command
              line;  it  will  not load the standard file or your personal units file unless you explicitly list
              them.  If filename is the empty string ('-f ""'), the default units file  (or  that  specified  by
              'UNITSFILE') will be loaded in addition to any others specified with '-f'.

       -L logfile, --log logfile
              Save  the  results  of  calculations in the file logfile; this can be useful if it is important to
              have a record of unit conversions or other calculations that are to be used extensively  or  in  a
              critical  activity  such  as  a  program or design project.  If logfile exits, the new results are
              appended to the file.  This option is ignored when 'units' is used non-interactively.  See Logging
              Calculations for a more detailed description and some examples.

       -H filename, --history filename
              Instruct 'units' to save history to filename, so that a record of your commands is  available  for
              retrieval across different 'units' invocations.  To prevent the history from being saved set file‐
              name to the empty string ('-H ""').  This option has no effect if readline is not available.

       -h, --help
              Print out a summary of the options for 'units'.

       -m, --minus
              Causes '-' to be interpreted as a subtraction operator.  This is the default behavior.

       -p, --product
              Causes  '-'  to be interpreted as a multiplication operator when it has two operands.  It will act
              as a negation operator when it has only one operand: '(-3)'.  By default '-' is treated as a  sub‐
              traction operator.

       --oldstar
              Causes  '*'  to  have  the  old-style  precedence,  higher than the precedence of division so that
              '1/2*3' will equal '1/6'.

       --newstar
              Forces '*' to have the new (default) precedence that follows  the  usual  rules  of  algebra:  the
              precedence of '*' is the same as the precedence of '/', so that '1/2*3' will equal '3/2'.

       --compact
              Give compact output featuring only the conversion factor.  This turns off the '--verbose' option.

       -q, --quiet, --silent
              Suppress  prompting  of the user for units and the display of statistics about the number of units
              loaded.

       -n, --nolists
              Disable conversion to unit lists.

       -r, --round
              When converting to a combination of units given by a unit list, round the value of the  last  unit
              in the list to the nearest integer.

       -S, --show-factor
              When  converting  to  a  combination  of units specified in a list, always show a non-unity factor
              before a unit that begins with a fraction with a unity denominator.  By default, if the unit in  a
              list begins with fraction of the form 1|x and its multiplier is an integer other than 1, the frac‐
              tion  is given as the product of the multiplier and the numerator (e.g., '3|8 in' rather than '3 *
              1|8 in').  In some cases, this is not what is wanted; for  example,  the  results  for  a  cooking
              recipe  might  show '3 * 1|2 cup' as '3|2 cup'.  With the '--show-factor' option, a result equiva‐
              lent to 1.5 cups will display as '3 * 1|2 cup' rather than '3|2 cup'.  A user-specified fractional
              unit with a numerator other than 1 is never overridden, however—if  a  unit  list  specifies  '3|4
              cup;1|2  cup',  a result equivalent to 1 1/2 cups will always be shown as '2 * 3|4 cup' whether or
              not the '--show-factor' option is given.

       -s, --strict
              Suppress conversion of units to their reciprocal units.  For example, 'units' will  normally  con‐
              vert  hertz  to  seconds  because  these  units  are reciprocals of each other.  The strict option
              requires that units be strictly conformable to perform a conversion, and will give an error if you
              attempt to convert hertz to seconds.

       -1, --one-line
              Give only one line of output (the forward conversion).  Do not print the reverse conversion.  If a
              reciprocal conversion is performed then 'units' will still  print  the  ``reciprocal  conversion''
              line.

       -t, --terse
              Give  terse  output  when  converting  units.   This  option can be used when calling 'units' from
              another program so that the output is easy to parse.  This option has the combined effect of these
              options: '--strict' '--quiet' '--one-line' '--compact'.  When combined with  '--version'  it  pro‐
              duces a display showing only the program name and version number.

       -v, --verbose
              Give  slightly more verbose output when converting units.  When combined with the '-c' option this
              gives the same effect as '--check-verbose'.   When  combined  with  '--version'  produces  a  more
              detailed output, equivalent to the '--info' option.

       -V, --version
              Print  the  program  version  number,  tell whether the 'readline' library has been included, tell
              whether UTF-8 support has been included; give the locale, the location of the default  units  data
              file,  and  the location of the personal units data file; indicate if the personal units data file
              does not exist.

       When given in combination with the '--terse' option, the program  prints  only  the  version  number  and
       exits.

       When  given  in combination with the '--verbose' option, the program, the '--version' option has the same
       effect as the '--info' option below.

       -I, --info
              Print the information given with the '--version' option, show the pathname of the  units  program,
              show  the status of the 'UNITSFILE' and 'MYUNITSFILE' environment variables, and additional infor‐
              mation about how 'units' locates the related files.  On systems  running  Microsoft  Windows,  the
              status  of the 'UNITSLOCALE' environment variable and information about the related locale map are
              also given.  This option is usually of interest only to developers and administrators, but it  can
              sometimes be useful for troubleshooting.

       Combining the '--version' and '--verbose' options has the same effect as giving '--info'.

       -U, --unitsfile
              Print  the  location  of  the default units data file and exit; if the file cannot be found, print
              ``Units data file not found''.

       -l locale, --locale locale
              Print the information given with the '--version' option, show the Force a specified locale such as
              'en_GB' to get British definitions by default.  This overrides the locale determined  from  system
              settings or environment variables.  See Locale for a description of locale format.

ADDING YOUR OWN DEFINITIONS

   Units Data Files
       The  units  and  prefixes  that  'units'  can  convert  are  defined  in  the  units data file, typically
       '/usr/share/units/definitions.units'.  If you can't find this file, run 'units --version' to get informa‐
       tion on the file locations for your installation.  Although you can extend or modify this  data  file  if
       you have appropriate user privileges, it's usually better to put extensions in separate files so that the
       definitions will be preserved if you update 'units'.

       You  can include additional data files in the units database using the '!include' command in the standard
       units data file. For example

          !include    /usr/local/share/units/local.units

       might be appropriate for a site-wide supplemental data file.  The location of the '!include' statement in
       the standard units data file is important; later definitions replace earlier ones, so any definitions  in
       an  included  file  will  override definitions before the '!include' statement in the standard units data
       file.  With normal invocation, no warning is given about redefinitions; to ensure that you don't have  an
       unintended redefinition, run 'units -c' after making changes to any units data file.

       If  you want to add your own units in addition to or in place of standard or site-wide supplemental units
       data files, you can include them in the '.units' file in your home directory.  If this file exists it  is
       read after the standard units data file, so that any definitions in this file will replace definitions of
       the  same  units  in  the standard data file or in files included from the standard data file.  This file
       will not be read if any units files are specified on the command line.  (Under Windows the personal units
       file is named 'unitdef.units'.)  Running 'units -V' will display the location and name of  your  personal
       units file.

       The  'units'  program  first tries to determine your home directory from the 'HOME' environment variable.
       On systems running Microsoft Windows, if 'HOME' does not exist, 'units' attempts to find your home direc‐
       tory from 'HOMEDRIVE', 'HOMEPATH' and 'USERPROFILE'.  You can specify an arbitrary file as your  personal
       units  data  file with the 'MYUNITSFILE' environment variable; if this variable exists, its value is used
       without searching your home directory.  The default units data files are described in more detail in Data
       Files.

   Defining New Units and Prefixes
       A unit is specified on a single line by giving its name and an equivalence.  Comments start  with  a  '#'
       character,  which  can  appear  anywhere in a line.  The backslash character ('\') acts as a continuation
       character if it appears as the last character on a line, making it possible  to  spread  definitions  out
       over  several  lines if desired.  A file can be included by giving the command '!include' followed by the
       file's name.  The '!'  must be the first character on the line.  The file will  be  sought  in  the  same
       directory  as  the  parent  file unless you give a full path.  The name of the file to be included cannot
       contain the comment character '#'.

       Unit names must not contain any of the operator characters '+', '-', '*', '/', '|', '^',  ';',  '~',  the
       comment  character '#', or parentheses.  They cannot begin or end with an underscore ('_'), a comma (',')
       or a decimal point ('.').  The figure dash (U+2012), typographical minus (`-'; U+2212), and en dash (`-';
       U+2013) are converted to the operator '-', so none of these characters can appear in unit  names.   Names
       cannot begin with a digit, and if a name ends in a digit other than zero, the digit must be preceded by a
       string beginning with an underscore, and afterwards consisting only of digits, decimal points, or commas.
       For  example,  'foo_2', 'foo_2,1', or 'foo_3.14' are valid names but 'foo2' or 'foo_a2' are invalid.  You
       could define nitrous oxide as

          N2O     nitrogen 2  + oxygen

       but would need to define nitrogen dioxide as

          NO_2    nitrogen + oxygen 2

       Be careful to define new units in terms of old ones so that a reduction leads  to  the  primitive  units,
       which  are  marked  with  '!'   characters.   Dimensionless  units  are  indicated  by  using  the string
       '!dimensionless' for the unit definition.

       When adding new units, be sure to use the '-c' option to check that the new units  reduce  properly.   If
       you  create  a  loop  in the units definitions, then 'units' will hang when invoked with the '-c' option.
       You will need to use the '--check-verbose' option, which prints out each unit as it is checked.  The pro‐
       gram will still hang, but the last unit printed will be the unit that caused the infinite loop.

       If you define any units that contain '+' characters, carefully check them because the  '-c'  option  will
       not  catch non-conformable sums.  Be careful with the '-' operator as well.  When used as a binary opera‐
       tor, the '-' character can perform addition or multiplication depending on the  options  used  to  invoke
       'units'.  To ensure consistent behavior use '-' only as a unary negation operator when writing units def‐
       initions.   To  multiply two units leave a space or use the '*' operator with care, recalling that it has
       two possible precedence values and may require parentheses to ensure consistent behavior.  To compute the
       difference of 'foo' and 'bar' write 'foo+(-bar)' or even 'foo+-bar'.

       Here is an example of a short data file that defines some basic units:

          m       !               # The meter is a primitive unit
          sec     !               # The second is a primitive unit
          rad     !dimensionless  # A dimensionless primitive unit
          micro-  1e-6            # Define a prefix
          minute  60 sec          # A minute is 60 seconds
          hour    60 min          # An hour is 60 minutes
          inch    0.0254 m        # Inch defined in terms of meters
          ft      12 inches       # The foot defined in terms of inches
          mile    5280 ft         # And the mile

       A unit that ends with a '-' character is a prefix.  If a prefix definition contains any  '/'  characters,
       be  sure  they are protected by parentheses.  If you define 'half- 1/2' then 'halfmeter' would be equiva‐
       lent to '1 / (2 meter)'.

   Defining Nonlinear Units
       Some unit conversions of interest are nonlinear; for example, temperature conversions between the Fahren‐
       heit and Celsius scales cannot be done by simply multiplying by conversion factors.

       When you give a linear unit definition such as 'inch 2.54 cm' you are providing information that  'units'
       uses  to  convert values in inches into primitive units of meters.  For nonlinear units, you give a func‐
       tional definition that provides the same information.

       Nonlinear units are represented using a functional notation.  It is best to regard this notation not as a
       function call but as a way of adding units to a number, much the same way that writing a linear unit name
       after a number adds units to that number.  Internally, nonlinear units are defined by a pair of functions
       that convert to and from linear units in the database, so that an eventual conversion to primitive  units
       is possible.

       Here is an example nonlinear unit definition:

          tempF(x) units=[1;K] domain=[-459.67,) range=[0,) \
                      (x+(-32)) degF + stdtemp ; (tempF+(-stdtemp))/degF + 32

       A  nonlinear  unit definition comprises a unit name, a formal parameter name, two functions, and optional
       specifications for units, the domain, and the range (the domain of the inverse function).  The  functions
       tell  'units'  how to convert to and from the new unit.  To produce valid results, the arguments of these
       functions need to have the correct dimensions and be within the  domains  for  which  the  functions  are
       defined.

       The  definition  begins  with the unit name followed immediately (with no spaces) by a '(' character.  In
       the parentheses is the name of the formal parameter.  Next is an  optional  specification  of  the  units
       required by the functions in the definition.  In the example above, the 'units=[1;K]' specification indi‐
       cates  that  the  'tempF' function requires an input argument conformable with '1' (i.e., the argument is
       dimensionless), and that the inverse function requires an input argument conformable with 'K'.  For  nor‐
       mal  nonlinear  units definition, the forward function will always take a dimensionless argument; in gen‐
       eral, the inverse function will need units that match the  quantity  measured  by  your  nonlinear  unit.
       Specifying  the units enables 'units' to perform error checking on function arguments, and also to assign
       units to domain and range specifications, which are described later.

       Next the function definitions appear.  In the example above, the 'tempF' function is defined by

          tempF(x) = (x+(-32)) degF + stdtemp

       This gives a rule for converting 'x' in the units 'tempF' to linear units of absolute temperature,  which
       makes it possible to convert from tempF to other units.

       To  enable conversions to Fahrenheit, you must give a rule for the inverse conversions.  The inverse will
       be 'x(tempF)' and its definition appears after a ';' character.  In our example, the inverse is

          x(tempF) = (tempF+(-stdtemp))/degF + 32

       This inverse definition takes an absolute temperature as its argument and converts it to  the  Fahrenheit
       temperature.  The inverse can be omitted by leaving out the ';' character and the inverse definition, but
       then  conversions  to the unit will not be possible.  If the inverse definition is omitted, the '--check'
       option will display a warning.  It is up to you to calculate and enter the correct  inverse  function  to
       obtain  proper conversions; the '--check' option tests the inverse at one point and prints an error if it
       is not valid there, but this is not a guarantee that your inverse is correct.

       With some definitions, the units may vary.  For example, the definition

          square(x)       x^2

       can have any arbitrary units, and can also take dimensionless arguments.  In such a case, you should  not
       specify  units.   If  a  definition takes a root of its arguments, the definition is valid only for units
       that yield such a root.  For example,

          squirt(x)       sqrt(x)

       is valid for a dimensionless argument, and for arguments with even powers of units.

       Some definitions may not be valid for all real numbers.  In such cases, 'units' can handle errors  better
       if you specify an appropriate domain and range.  You specify the domain and range as shown below:

          baume(d) units=[1;g/cm^3] domain=[0,130.5] range=[1,10] \
                   (145/(145-d)) g/cm^3 ; (baume+-g/cm^3) 145 / baume

       In  this example the domain is specified after 'domain=' with the endpoints given in brackets.  In accord
       with mathematical convention, square brackets indicate a closed interval  (one  that  includes  its  end‐
       points),  and parentheses indicate an open interval (one that does not include its endpoints).  An inter‐
       val can be open or closed on one or both ends; an interval that is unbounded on either end  is  indicated
       by omitting the limit on that end.  For example, a quantity to which decibel (dB) is applied may have any
       value greater than zero, so the range is indicated by '(0,)':

          decibel(x) units=[1;1] range=(0,) 10^(x/10); 10 log(decibel)

       If the domain or range is given, the second endpoint must be greater than the first.

       The domain and range specifications can appear independently and in any order along with the units speci‐
       fication.   The  values  for  the domain and range endpoints are attached to the units given in the units
       specification, and if necessary, the parameter value is adjusted for comparison with the endpoints.   For
       example,  if  a  definition  includes 'units=[1;ft]' and 'range=[3,)', the range will be taken as 3 ft to
       infinity.  If the  function  is  passed  a  parameter  of  '900 mm',  that  value  will  be  adjusted  to
       2.9527559 ft,  which is outside the specified range.  If you omit the units specification from the previ‐
       ous example, 'units' can not tell whether you intend the lower endpoint to be  3 ft  or  3 microfurlongs,
       and  can  not adjust the parameter value of 900 mm for comparison.  Without units, numerical values other
       than zero or plus or minus infinity for domain or range endpoints are meaningless, and  accordingly  they
       are not allowed.  If you give other values without units then the definition will be ignored and you will
       get an error message.

       Although  the  units, domain, and range specifications are optional, it's best to give them when they are
       applicable; doing so allows 'units' to perform better error checking and give  more  helpful  error  mes‐
       sages.   Giving  the  domain and range also enables the '--check' option to find a point in the domain to
       use for its point check of your inverse definition.

       You can make synonyms for nonlinear units by providing both the forward and  inverse  functions;  inverse
       functions can be obtained using the '~' operator.  So to create a synonym for 'tempF' you could write

          fahrenheit(x) units=[1;K] tempF(x); ~tempF(fahrenheit)

       This is useful for creating a nonlinear unit definition that differs slightly from an existing definition
       without having to repeat the original functions.  For example,

          dBW(x)     units=[1;W] range=[0,) dB(x) W ;  ~dB(dBW/W)

       If  you  wish  a  synonym to refer to an existing nonlinear unit without modification, you can do so more
       simply by adding the synonym with appended parentheses as a new unit, with the existing  nonlinear  unit—
       without parentheses—as the definition.  So to create a synonym for 'tempF' you could write

          fahrenheit()  tempF

       The definition must be a nonlinear unit; for example, the synonym

          fahrenheit()  meter

       will result in an error message when 'units' starts.

       You  may occasionally wish to define a function that operates on units.  This can be done using a nonlin‐
       ear unit definition.  For example, the definition below provides conversion between radius and  the  area
       of  a circle.  This definition requires a length as input and produces an area as output, as indicated by
       the 'units=' specification.  Specifying the range as the nonnegative numbers can  prevent  cryptic  error
       messages.

          circlearea(r) units=[m;m^2] range=[0,)   pi r^2 ; sqrt(circlearea/pi)

   Defining Piecewise Linear Units
       Sometimes  you  may  be interested in a piecewise linear unit such as many wire gauges.  Piecewise linear
       units can be defined by specifying conversions to linear units on a list of points.  Conversion at  other
       points will be done by linear interpolation.  A partial definition of zinc gauge is

          zincgauge[in] 1 0.002, 10 0.02, 15 0.04, 19 0.06, 23 0.1

       In  this example, 'zincgauge' is the name of the piecewise linear unit.  The definition of such a unit is
       indicated by the embedded '[' character.  After the bracket, you should indicate the units to be attached
       to the numbers in the table.  No spaces can appear before the ']' character, so a definition like 'foo[kg
       meters]' is invalid; instead write 'foo[kg*meters]'.  The definition of the unit consists of  a  list  of
       pairs  optionally  separated  by  commas.  This list defines a function for converting from the piecewise
       linear unit to linear units.  The first item in each pair is the function argument; the  second  item  is
       the  value  of  the  function at that argument (in the units specified in brackets).  In this example, we
       define 'zincgauge' at five points.  For example, we set 'zincgauge(1)' equal to '0.002 in'.   Definitions
       like this may be  more readable  if written using  continuation characters as

          zincgauge[in] \
               1 0.002  \
              10 0.02   \
              15 0.04   \
              19 0.06   \
              23 0.1

       With the preceding definition, the following conversion can be performed:

          You have: zincgauge(10)
          You want: in
              * 0.02
              / 50
          You have: .01 inch
          You want: zincgauge
              5

       If  you  define a piecewise linear unit that is not strictly monotonic, then the inverse will not be well
       defined.  If the inverse is requested for such a unit, 'units' will return the smallest inverse.

       After adding nonlinear units definitions, you should normally run 'units --check' to  check  for  errors.
       If  the  'units'  keyword  is  not given, the '--check' option checks a nonlinear unit definition using a
       dimensionless argument, and then checks using an arbitrary combination of units, as well  as  the  square
       and cube of that combination; a warning is given if any of these tests fail.  For example,

          Warning: function 'squirt(x)' defined as 'sqrt(x)'
                   failed for some test inputs:
                   squirt(7(kg K)^1): Unit not a root
                   squirt(7(kg K)^3): Unit not a root

       Running  'units --check'  will  print  a warning if a non-monotonic piecewise linear unit is encountered.
       For example, the relationship between ANSI coated abrasive designation and mean  particle  size  is  non-
       monotonic in the vicinity of 800 grit:

          ansicoated[micron] \
               . . .
              600 10.55 \
              800 11.5 \
              1000 9.5 \

       Running 'units --check' would give the error message

          Table 'ansicoated' lacks unique inverse around entry 800

       Although  the  inverse  is not well defined in this region, it's not really an error.  Viewing such error
       messages can be tedious, and if there are enough of them, they can  distract  from  true  errors.   Error
       checking  for nonlinear unit definitions can be suppressed by giving the 'noerror' keyword; for the exam‐
       ples above, this could be done as

          squirt(x) noerror domain=[0,) range=[0,) sqrt(x); squirt^2
          ansicoated[micron] noerror \
               . . .

       Use the 'noerror' keyword with caution.  The safest approach after adding a nonlinear unit definition  is
       to run 'units --check' and confirm that there are no actual errors before adding the 'noerror' keyword.

   Defining Unit List Aliases
       Unit  list aliases are treated differently from unit definitions, because they are a data entry shorthand
       rather than a true definition for a new unit.  A unit list alias definition begins with  '!unitlist'  and
       includes the alias and the definition;  for example, the aliases included in the standard units data file
       are

          !unitlist   hms     hr;min;sec
          !unitlist   time    year;day;hr;min;sec
          !unitlist   dms     deg;arcmin;arcsec
          !unitlist   ftin    ft;in;1|8 in
          !unitlist   usvol   cup;3|4 cup;2|3 cup;1|2 cup;1|3 cup;1|4 cup;\
                              tbsp;tsp;1|2 tsp;1|4 tsp;1|8 tsp

       Unit  list  aliases are only for unit lists, so the definition must include a ';'.  Unit list aliases can
       never be combined with units or other unit list aliases, so the definition of 'time'  shown  above  could
       not have been shortened to 'year;day;hms'.

       As  usual,  be  sure to run 'units --check' to ensure that the units listed in unit list aliases are con‐
       formable.

NUMERIC OUTPUT FORMAT

       By  default,  'units'  shows  results  to  eight  significant  digits.  You  can  change  this  with  the
       '--exponential',  '--digits', and '--output-format' options.  The first sets an exponential format (i.e.,
       scientific notation) like that used in the original Unix 'units' program, the second allows you to  spec‐
       ify  a  different  number of significant digits, and the last allows you to control the output appearance
       using the format for the 'printf()' function in the C programming language.  If you only want  to  change
       the   number  of  significant  digits  or  specify  exponential  format  type,  use  the  '--digits'  and
       '--exponential' options.  The '--output-format' option affords the greatest control of the output appear‐
       ance, but requires at least rudimentary knowledge of the 'printf()' format syntax. See Invoking Units for
       descriptions of these options.

   Format Specification
       The format specification recognized with the '--output-format' option is a subset of that for 'printf()'.
       The format specification has the form '%'[flags][width]['.'precision]type; it must begin  with  '%',  and
       must  end  with  a floating-point type specifier: 'g' or 'G' to specify the number of significant digits,
       'e' or 'E' for scientific notation, and 'f' for fixed-point decimal.  The ISO C99 standard added the  'F'
       type  for  fixed-point  decimal and the 'a' and 'A' types for hexadecimal floating point; these types are
       allowed with compilers that support them.  Type length modifiers (e.g., 'L' to indicate  a  long  double)
       are inapplicable and are not allowed.

       The  default  format for 'units' is '%.8g'; for greater precision, you could specify '-o %.15g'.  The 'g'
       and 'G' format types use exponential format whenever the exponent would be less than  -4,  so  the  value
       0.000013  displays as '1.3e-005'.  These types also use exponential notation when the exponent is greater
       than or equal to the precision, so with the default format, the value 5e7 displays as '50000000' and  the
       value 5e8 displays as '5e+008'.  If you prefer fixed-point display, you might specify '-o %.8f'; however,
       small numbers will display very few significant digits, and values less than 0.5e-8 will show nothing but
       zeros.

       The  format specification may include one or more optional flags: '+', ' ' (space), '#', '-', or '0' (the
       digit zero).  The digit-grouping flag ''' is allowed with compilers that support it.  Flags are  followed
       by  an  optional  value  for the minimum field width, and an optional precision specification that begins
       with a period (e.g., '.6').  The field width includes the digits, decimal point, the exponent,  thousands
       separators (with the digit-grouping flag), and the sign if any of these are shown.

   Flags
       The  '+'  flag  causes  the output to have a sign ('+' or '-').  The space flag ' ' is similar to the '+'
       flag, except that when the value is positive, it is prefixed with a space rather than a plus  sign;  this
       flag  is ignored if the '+' flag is also given.  The '+' or ' ' flag could be useful if conversions might
       include positive and negative results, and you wanted to align the decimal points  in  exponential  nota‐
       tion.  The '#' flag causes the output value to contain a decimal point in all cases; by default, the out‐
       put  contains  a decimal point only if there are digits (which can be trailing zeros) to the right of the
       point.  With the 'g' or 'G' types, the '#' flag also prevents the suppression  of  trailing  zeros.   The
       digit-grouping flag ''' shows a thousands separator in digits to the left of the decimal point.  This can
       be useful when displaying large numbers in fixed-point decimal; for example, with the format '%f',

          You have: mile
          You want: microfurlong
                  * 8000000.000000
                  / 0.000000

       the  magnitude of the first result may not be immediately obvious without counting the digits to the left
       of the decimal point.  If the thousands separator is the comma (','), the output with  the  format  '%'f'
       might be

          You have: mile
          You want: microfurlong
                  * 8,000,000.000000
                  / 0.000000

       making the magnitude readily apparent.  Unfortunately, few compilers support the digit-grouping flag.

       With  the  '-' flag, the output value is left aligned within the specified field width.  If a field width
       greater than needed to show the output value is specified, the '0' (zero) flag causes the output value to
       be left padded with zeros until the specified field width  is  reached;  for  example,  with  the  format
       '%011.6f',

          You have: troypound
          You want: grain
                  * 5760.000000
                  / 0000.000174

       The '0' flag has no effect if the '-' (left align) flag is given.

   Field Width
       By default, the output value is left aligned and shown with the minimum width necessary for the specified
       (or  default)  precision.   If  a  field  width  greater than this is specified, the value shown is right
       aligned, and padded on the left with enough spaces to provide the specified field width.  A width  speci‐
       fication  is  typically  used  with  fixed-point  decimal to have columns of numbers align at the decimal
       point; this arguably is less useful with 'units' than with long columnar output, but it  may  nonetheless
       assist in quickly assessing the relative magnitudes of results.  For example, with the format '%12.6f',

          You have: km
          You want: in
                  * 39370.078740
                  /     0.000025
          You have: km
          You want: rod
                  *   198.838782
                  /     0.005029
          You have: km
          You want: furlong
                  *     4.970970
                  /     0.201168

   Precision
       The  meaning  of  ``precision''  depends on the format type.  With 'g' or 'G', it specifies the number of
       significant digits (like the '--digits' option); with 'e', 'E', 'f', or 'F',  it  specifies  the  maximum
       number of digits to be shown after the decimal point.

       With the 'g' and 'G' format types, trailing zeros are suppressed, so the results may sometimes have fewer
       digits  than  the  specified precision (as indicated above, the '#' flag causes trailing zeros to be dis‐
       played).

       The default precision is 6, so '%g' is equivalent to '%.6g', and would show the output to six significant
       digits.  Similarly, '%e' or '%f' would show the output with six digits after the decimal point.

       The C 'printf()' function allows a precision of arbitrary size, whether or not  all  of  the  digits  are
       meaningful.  With most compilers, the maximum internal precision with 'units' is 15 decimal digits (or 13
       hexadecimal digits).  With the '--digits' option, you are limited to the maximum internal precision; with
       the  '--output-format'  option, you may specify a precision greater than this, but it may not be meaning‐
       ful.  In some cases, specifying excess precision can result in rounding artifacts.  For example, a  pound
       is exactly 7000 grains, but with the format '%.18g', the output might be

          You have: pound
          You want: grain
                  * 6999.9999999999991
                  / 0.00014285714285714287

       With the format '%.25g' you might get the following:

          You have: 1/3
          You want:
                  Definition: 0.333333333333333314829616256247

       In  this case the displayed value includes a series of digits that represent the underlying binary float‐
       ing-point approximation to 1/3 but are not meaningful for  the  desired  computation.   In  general,  the
       result  with excess precision is system dependent.  The precision affects only the display of numbers; if
       a result relies on physical constants that are not known to the specified precision, the number of physi‐
       cally meaningful digits may be less than the number of digits shown.

       See the documentation for 'printf()' for more detailed descriptions of the format specification.

       The '--output-format' option is incompatible with the '--exponential' or '--digits' options; if the  for‐
       mer is given in combination with either of the latter, the format is controlled by the last option given.

LOCALIZATION

       Some  units  have different values in different locations.  The localization feature accommodates this by
       allowing a units data file to specify definitions that depend on the user's locale.

   Locale
       A locale is a subset of a user's environment that indicates the user's language  and  country,  and  some
       attendant  preferences,  such  as the formatting of dates.  The 'units' program attempts to determine the
       locale from the POSIX setlocale function; if this cannot be done, 'units' examines the environment  vari‐
       ables  'LC_CTYPE'  and  'LANG'.  On POSIX systems, a locale is of the form language'_'country, where lan‐
       guage is the two-character code from ISO 639-1 and country is the two-character  code  from  ISO  3166-1;
       language is lower case and country is upper case. For example, the POSIX locale for the United Kingdom is
       'en_GB'.

       On  systems  running Microsoft Windows, the value returned by setlocale() is different from that on POSIX
       systems; 'units' attempts to map the Windows value to a POSIX value by means  of  a  table  in  the  file
       'locale_map.txt'  in the same directory as the other data files.  The file includes entries for many com‐
       binations  of  language  and  country,  and  can  be  extended  to  include  other   combinations.    The
       'locale_map.txt' file comprises two tab-separated columns; each entry is of the form

          Windows-locale   POSIX-locale

       where  POSIX-locale  is as described above, and Windows-locale typically spells out both the language and
       country.  For example, the entry for the United States is

          English_United States   en_US

       You can force 'units' to run in a desired locale by using the '-l' option.

       In order to create unit definitions for a particular locale you begin a block of definitions  in  a  unit
       datafile  with  '!locale'  followed  by a locale name.  The '!'  must be the first character on the line.
       The 'units' program reads the following definitions only if the current  locale  matches.   You  end  the
       block of localized units with '!endlocale'.  Here is an example, which defines the British gallon.

          !locale en_GB
          gallon       4.54609 liter
          !endlocale

   Additional Localization
       Sometimes  the  locale  isn't  sufficient to determine unit preferences.  There could be regional prefer‐
       ences, or a company could have specific preferences.  Though probably uncommon,  such  differences  could
       arise with the choice of English customary units outside of English-speaking countries.  To address this,
       'units'  allows  specifying  definitions  that  depend on environment variable settings.  The environment
       variables can be controled based on the current locale, or the user can set them to  force  a  particular
       group of definitions.

       A  conditional block of definitions in a units data file begins with either '!var' or '!varnot' following
       by an environment variable name and then a space separated list of values.  The leading '!'  must  appear
       in  the first column of a units data file, and the conditional block is terminated by '!endvar'.  Defini‐
       tions in blocks beginning with '!var' are executed only if the environment variable is exactly  equal  to
       one  of the listed values.  Definitions in blocks beginning with '!varnot' are executed only if the envi‐
       ronment variable does not equal any of the list values.

       The inch has long been a customary measure of length in many places.  The word comes from the latin uncia
       meaning ``one twelfth,'' referring to its relationship with the foot.  By the 20th century, the inch  was
       officially  defined in English-speaking countries relative to the yard, but until 1959, the yard differed
       slightly among those countries.  In France the customary inch, which was displaced in 1799 by the  meter,
       had a different length based on a french foot.  These customary definitions could be accommodated as fol‐
       lows:

          !var INCH_UNIT usa
          yard          3600|3937 m
          !endvar
          !var INCH_UNIT canada
          yard          0.9144 meter
          !endvar
          !var INCH_UNIT uk
          yard          0.91439841 meter
          !endvar
          !var INCH_UNIT canada uk usa
          foot          1|3 yard
          inch          1|12 foot
          !endvar
          !var INCH_UNIT france
          foot          144|443.296 m
          inch          1|12 foot
          line          1|12 inch
          !endvar
          !varnot INCH_UNIT usa uk france canada
          !message Unknown value for INCH_UNIT
          !endvar

       When 'units' reads the above definitions it will check the environment variable 'INCH_UNIT' and load only
       the  definitions  for  the appropriate section.  If 'INCH_UNIT' is unset or is not set to one of the four
       values listed then 'units' will run the last block.  In this case that block uses the '!message'  command
       to display a warning message.  Alternatively that block could set default values.

       In  order  to create default values that are overridden by user settings the data file can use the '!set'
       command, which sets an environment variable only if it is not already set;  these settings are  only  for
       the  current  'units'  invocation  and  do  not  persist.  So if the example above were preceded by '!set
       INCH_UNIT france' then this would make 'france' the default value for 'INCH_UNIT'.  If the user  had  set
       the variable in the environment before invoking 'units', then 'units' would use the user's value.

       To  link  these  settings to the user's locale you combine the '!set' command with the '!locale' command.
       If you wanted to combine the above example with suitable locales you could do by preceding the above def‐
       inition with the following:

          !locale en_US
          !set INCH_UNIT usa
          !endlocale
          !locale en_GB
          !set INCH_UNIT uk
          !endlocale
          !locale en_CA
          !set INCH_UNIT canada
          !endlocale
          !locale fr_FR
          !set INCH_UNIT france
          !endlocale
          !set INCH_UNIT france

       These definitions set the overall default for 'INCH_UNIT' to 'france' and set  default  values  for  four
       locales  appropriately.   The overall default setting comes last so that it only applies when 'INCH_UNIT'
       was not set by one of the other commands or by the user.

       If the variable given after '!var' or '!varnot' is undefined then 'units' prints  an  error  message  and
       ignores  the definitions that follow.  Use '!set' to create defaults to prevent this situation from aris‐
       ing.  The '-c' option only checks the definitions that are active for the current environment and locale,
       so when adding new definitions take care to check that all cases give rise to a well defined set of defi‐
       nitions.

ENVIRONMENT VARIABLES

       The 'units' program uses the following environment variables:

       HOME   Specifies the location of your home directory; it is used by 'units' to find a personal units data
              file '.units'.  On systems running Microsoft Windows, the file is 'unitdef.units', and  if  'HOME'
              does not exist, 'units' tries to determine your home directory from the 'HOMEDRIVE' and 'HOMEPATH'
              environment    variables;    if    these   variables   do   not   exist,   units   finally   tries
              'USERPROFILE'—typically    'C:\Users\username'    (Windows     Vista     and     Windows 7)     or
              'C:\Documents and Settings\username' (Windows XP).

       LC_CTYPE, LANG
              Checked  to  determine the locale if 'units' cannot obtain it from the operating system.  Sections
              of the standard units data file are specific to certain locales.

       MYUNITSFILE
              Specifies your personal units data file.  If this variable exists, 'units' uses its  value  rather
              than  searching  your  home directory for '.units'.  The personal units file will not be loaded if
              any data files are given using the '-f' option.

       PAGER  Specifies the pager to use for help and for displaying the conformable units.  The  help  function
              browses  the  units database and calls the pager using the '+n'n syntax for specifying a line num‐
              ber.  The default pager is 'more'; 'PAGER' can be used to specify  alternatives  such  as  'less',
              'pg', 'emacs', or 'vi'.

       UNITS_ENGLISH
              Set  to  either 'US' or 'GB' to choose United States or British volume definitions, overriding the
              default from your locale.

       UNITSFILE
              Specifies the units data file to use (instead of the default).  You  can  only  specify  a  single
              units  data  file  using  this environment variable.  If units data files are given using the '-f'
              option, the file specified by 'UNITSFILE' will be not be loaded unless the '-f'  option  is  given
              with the empty string ('units -f ""').

       UNITSLOCALEMAP
              Windows  only;  this  variable has no effect on Unix-like systems.  Specifies the units locale map
              file to use (instead of the default).  This variable seldom needs to be set, but you can use it to
              ensure that the locale map file will be found if you specify a location for the  units  data  file
              using  either  the '-f' option or the 'UNITSFILE' environment variable, and that location does not
              also contain the locale map file.

DATA FILES

       The 'units' program uses two default data files: 'definitions.units' and 'currency.units'.   The  program
       can also use an optional personal units data file '.units' ('unitdef.units' under Windows) located in the
       user's home directory.  The personal units data file is described in more detail in Units Data Files.

       On  Unix-like  systems, the data files are typically located in '/usr/share/units' if 'units' is provided
       with the operating system, or in '/usr/local/share/units' if 'units' is compiled from the source distrib‐
       ution.

       On systems running Microsoft Windows, the files may be in the same locations if  Unix-like  commands  are
       available, a Unix-like file structure is present (e.g., 'C:/usr/local'), and 'units' is compiled from the
       source   distribution.    If   Unix-like   commands   are  not  available,  a  more  common  location  is
       'C:\Program Files (x86)\GNU\units' (for 64-bit  Windows  installations)  or  'C:\Program Files\GNU\units'
       (for 32-bit installations).

       If  'units' is obtained from the GNU Win32 Project (http://gnuwin32.sourceforge.net/), the files are com‐
       monly in 'C:\Program Files\GnuWin32\share\units'.

       If the default units data file is not an absolute pathname, 'units' will look for the file in the  direc‐
       tory  that contains the 'units' program; if the file is not found there, 'units' will look in a directory
       '../share/units' relative to the directory with the 'units' program.

       You can determine the location of the files by running 'units --version'.   Running  'units --info'  will
       give you additional information about the files, how 'units' will attempt to find them, and the status of
       the related environment variables.

UNICODE SUPPORT

       The  standard units data file is in Unicode, using UTF-8 encoding.  Most definitions use only ASCII char‐
       acters (i.e., code points U+0000 through U+007F); definitions using non-ASCII characters appear in blocks
       beginning with '!utf8' and ending with '!endutf8'.

       When 'units' starts, it checks the locale to determine the character set.  If 'units'  is  compiled  with
       Unicode  support  and  definitions;  otherwise  these  definitions  are ignored.  When Unicode support is
       active, 'units' will check every line of all of the units data files for invalid  or  non-printing  UTF-8
       sequences;  if  such sequences occur, 'units' ignores the entire line.  In addition to checking validity,
       'units' determines the display width of non-ASCII characters to ensure proper positioning of the  pointer
       in some error messages and to align columns for the 'search' and '?'  commands.

       At  present,  'units'  does not support Unicode under Microsoft Windows.  The UTF-16 and UTF-32 encodings
       are not supported on any systems.

       If definitions that contain non-ASCII characters are added to a units data file, those definitions should
       be enclosed within '!utf8' ...  '!endutf8' to ensure that they are only loaded when  Unicode  support  is
       available.   As  usual,  the  '!'  must appear as the first character on the line.  As discussed in Units
       Data Files, it's usually best to put such definitions in supplemental data files linked by an  '!include'
       command or in a personal units data file.

       When  Unicode  support  is not active, 'units' makes no assumptions about character encoding, except that
       characters in the range 00-7F hexadecimal correspond to ASCII encoding.  Non-ASCII characters are  simply
       sequences  of bytes, and have no special meanings; for definitions in supplementary units data files, you
       can use any encoding consistent with this assumption.  For example, if you wish to use non-ASCII  charac‐
       ters  in  definitions  when  running  'units'  under Windows, you can use a character set such as Windows
       ``ANSI'' (code page 1252 in the US and Western Europe).  You can even use UTF-8, though some messages may
       be improperly aligned, and 'units' will not detect invalid UTF-8 sequences.  If you  use  UTF-8  encoding
       when  Unicode  support  is not active, you should place any definitions with non-ASCII characters outside
       '!utf8' ...  '!endutf8' blocks—otherwise, they will be ignored.

       Typeset material other than code examples usually uses the Unicode minus (U+2212) rather than  the  ASCII
       hyphen-minus  operator  (U+002D)  used in 'units'; the figure dash (U+2012) and en dash (U+2013) are also
       occasionally used.  To allow such material to be copied and pasted for interactive use or in  units  data
       files,  'units'  converts these characters to U+002D before further processing.  Because of this, none of
       these characters can appear in unit names.

READLINE SUPPORT

       If the 'readline' package has been compiled in, then when 'units' is used interactively, numerous command
       line editing features are available.  To check if your version of 'units' includes 'readline', invoke the
       program with the '--version' option.

       For complete information about 'readline', consult the documentation for the 'readline' package.  Without
       any configuration, 'units' will allow editing in the style of emacs.  Of particular use with 'units'  are
       the completion commands.

       If  you  type  a few characters and then hit ESC followed by '?'  then 'units' will display a list of all
       the units that start with the characters typed.  For example, if you type 'metr' and then request comple‐
       tion, you will see something like this:

          You have: metr
          metre             metriccup         metrichorsepower  metrictenth
          metretes          metricfifth       metricounce       metricton
          metriccarat       metricgrain       metricquart       metricyarncount
          You have: metr

       If there is a unique way to complete a unitname, you can hit the TAB key and  'units'  will  provide  the
       rest  of the unit name.  If 'units' beeps, it means that there is no unique completion.  Pressing the TAB
       key a second time will print the list of all completions.

       The readline library also keeps a history of the values you enter.  You can  move  through  this  history
       using  the  up and down arrows.  The history is saved to the file '.units_history' in your home directory
       so that it will persist across multiple 'units' invocations.  If you wish to  keep  work  for  a  certain
       project  separate you can change the history filename using the '--history' option.  You could, for exam‐
       ple, make an alias for 'units' to 'units --history .units_history' so that 'units'  would  save  separate
       history  in  the current directory.  The length of each history file is limited to 5000 lines.  Note also
       that if you run several concurrent copies of 'units' each one will save its new history  to  the  history
       file upon exit.

UPDATING CURRENCY EXCHANGE RATES

       The  units  program includes currency exchange rates and prices for some precious metals in the database.
       Of course, these values change over time, sometimes very rapidly, and 'units' cannot  provide  real  time
       values.   To  update the exchange rates run the 'units_cur', which rewrites the files containing the cur‐
       rency rates,  typically  '/usr/share/units/currency.units'.   This  program  requires  'python'  and  the
       'unidecode'  package,  and  must  be  run with suitable permissions to write the file.  To keep the rates
       updated automatically, run it using a cron job on a Unix-like system, or a similar scheduling program  on
       a  different  system.   Currency  exchange rates are taken from Time Genie (http://www.timegenie.com) and
       precious metals pricing from Packetizer (www.packetizer.com).  These sites update once per day, so  there
       is  no  benefit in running the update script more often than daily.  You can run 'units_cur' with a file‐
       name specified on the command line and it will write the data to that file.  If you give '-' for the file
       it will write to standard output.

DATABASE COMMAND SYNTAX

       unit definition
              Define a regular unit.

       prefix- definition
              Define a prefix.

       funcname(var) noerror units=[in-units,out-units] domain=[x1,x2] range=[y1,y2] definition(var) ;
       inverse(funcname)
              Define a nonlinear unit or  unit  function.   The  four  optional  keywords  'noerror',  'units=',
              'range=' and 'domain=' can appear in any order.  The definition of the inverse is optional.

       tabname[out-units] noerror pair-list
              Define  a  piecewise linear unit.  The pair list gives the points on the table listed in ascending
              order.  The 'noerror' keyword is optional.

       !endlocale
              End a block of definitions beginning with '!locale'

       !endutf8
              End a block of definitions begun with '!utf8'

       !endvar
              End a block of definitions begun with '!var' or '!varnot'

       !include file
              Include the specified file.

       !locale value
              Load the following definitions only of the locale is set to value.

       !message text
              Display text when the database is read unless the quiet option ('-q') is enabled.

       !set variable value
              Sets the environment variable, variable, to the specified value only if it is not already set.

       !unitlist alias definition
              Define a unit list alias.

       !utf8  Load the following definitions only if 'units' is running with UTF-8 enabled.

       !var envar value-list
              Load the block of definitions that follows only if the environment variable envar is set to one of
              the values listed in the space-separated value list.  If envar is not set, 'units' prints an error
              message and ignores the block of definitions.

       !varnot envar value-list
              Load the block of definitions that follows only if the environment variable envar is set to  value
              that  is  not  listed  in  the space-separated value list.  If envar is not set, 'units' prints an
              error message and ignores the block of definitions.

GNU FREE DOCUMENTATION LICENSE

FILES

       /usr/share/units/definitions.units — the standard units data file

AUTHOR

                                                  19 March 2014                                         UNITS(1)