Provided by: netperfmeter_1.2.3-1ubuntu1_amd64 bug

NAME

     netperfmeter — Network Performance Meter

SYNOPSIS

     netperfmeter [Port]
     netperfmeter [Destination:Port] -local=Address[,Address,...] -runtime=Seconds -config=Name
                  -scalar=Name -vector=Name -activenodename=Description
                  -passivenodename=Description -quiet -verbose -verbosity=Level -tcp -mptcp -sctp
                  -udp -dccp [FLOWSPEC] [...]

DESCRIPTION

     netperfmeter is a network performance meter for the UDP, TCP, MPTCP, SCTP and DCCP transport
     protocols. It simultaneously transmits bidirectional flows to an endpoint and measures the
     resulting flow bandwidths. The results are written as vector and scalar files.

ARGUMENTS

     The following arguments have to be provided:

     Port    The port number for the passive side's data socket. The port number of the control
             socket will be port+1. Specifying a port number turns netperfmeter in passive mode,
             i.e. it will wait for incoming connections.

     Destination:Port
             Specifies the destination endpoint to connect to. This will turn netperfmeter in
             active mode, i.e. it will connect to the specified remote endpoint.

     local=Address[,Address,...]
             Specifies address(es) of the local endpoint. For TCP, UDP and DCCP, only the first
             address is used!

     runtime
             Specifies the measurement runtime in seconds. After the given time span,
             netperfmeter will finish the measurement.

     config=Name
             Specifies the name of the configuration file to write. Default is output.config.

     vector=Name
             Specifies the name pattern of the vector files to write. If the suffix of this name
             is .bz2, the file will be BZip2-compressed on the fly. The vector name is
             automatically extended to name the flow vector files by adding
             -<active|passive>-<flow_id>-<stream_id> before the suffix.  Default is
             vector.vec.bz2, hence the name of the vector file for flow 5, stream 2 on the
             passive node will be vector-passive-00000005-0002.vec.bz2.

     scalar=Name
             Specifies the name pattern of the scalar files to write. If the suffix of this name
             is .bz2, the file will be BZip2-compressed on the fly. The scalar name is
             automatically extended to name the flow scalar files by adding
             -<active|passive>-<flow_id>-<stream_id> before the suffix.  Default is
             scalar.vec.bz2, hence the name of the scalar file for flow 5, stream 2 on the
             passive node will be scalar-passive-00000005-0002.vec.bz2.

     activenodename=Description
             Sets a textual description of the active node (e.g. Client).

     passivenodename=Description
             Sets a textual description of the passive node (e.g. Server).

     quiet   Reduces verbosity of log output. May be specified multiple times.

     verbose
             Increases verbosity of log output. May be specified multiple times.

     verbosity=Level
             Sets the verbosity of the log output to a given level, from 0 (lowest) to 6
             (highest).

     sctp    Establish a new SCTP association. The streams of this association must be specified
             by one or more FLOWSPEC specifications as following parameters.

     tcp     Establish a new TCP or MPTCP connection. The flow of this connection must be
             specified by a FLOWSPEC specification as following parameter. MPTCP support in
             NetPerfMeter is realized as additional "MPTCP" socket (i.e. another TCP socket, but
             bound to another port number and with CMT enabled). That is, for MPTCP usage, it
             must contain the option cmt=mptcp (see below) to usage the MPTCP socket instead of
             the TCP socket.

     udp     Establish a new UDP connection. The flow of this connection must be specified by a
             FLOWSPEC specification as following parameter.

     dccp    Establish a new DCCP connection. The flow of this connection must be specified by a
             FLOWSPEC specification as following parameter. Note, that DCCP is not available on
             all platforms yet. Currently, only Linux provides DCCP in its official kernel.

     FLOWSPEC
             Specifies a new flow. The format is:
             outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option:...
             The first four parameters
             (outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option)
             may be substituted by the option "default", creating a flow with some more or less
             useful default parameters.

             outgoing_frame_rate
                     The frame rate of the outgoing transfer (i.e. active node to passive node).
                     If set to const0, the sender will be saturarted, i.e. it will try to send as
                     much as possible.

             outgoing_frame_size
                     The frame size of the outgoing transfer (i.e. active node to passive node).
                     If set to const0, there will be *no* data transmission in this direction.

             incoming_frame_rate
                     The frame rate of the incoming transfer (i.e. passive node to active node).
                     See outgoing_frame_rate for details.

             incoming_frame_size
                     The frame size of the incoming transfer (i.e. active node to passive node).
                     See outgoing_frame_size for details.

             Possible options:

                     id=Flow Identifier
                             Sets an ID number for the flow. The IDs within a measurement must be
                             unique!

                     description=Description
                             Sets a textual description of the flow (e.g. HTTP-Flow). Do not use
                             spaces in the description!

                     maxmsgsize=Bytes
                             Splits frames into messages of at most the given number of bytes.
                             Messages may not exceed 65535 bytes.

                     defragtimeout=Milliseconds
                             Messages not received within this timeout after the last
                             successfully received message are accounted as lost. NOTE: this also
                             happens if the transport protocol is reliable and the message is
                             actually received later!

                     unordered=Fraction
                             Specifies the fraction of the messages that will be sent in
                             unordered mode (SCTP only).

                     ordered=Fraction
                             Specifies the fraction of the messages that will be sent in ordered
                             mode (SCTP only).

                     reliable=Fraction
                             Specifies the fraction of the messages that will be sent in reliable
                             mode (SCTP only).

                     unreliable=Fraction
                             Specifies the fraction of the messages that will be sent in
                             unreliable mode (SCTP only).

                     rtx_timeout=Milliseconds
                             Sets the retransmission timeout for unreliable messages (SCTP only;
                             not available on all platforms!)

                     rtx_trials=Trials
                             Sets the retransmission trials for unreliable messages (SCTP only;
                             not available on all platforms!)

                     rcvbuf=Bytes
                             Sets the receiver buffer size to the given number of bytes.

                     sndbuf=Bytes
                             Sets the sender buffer size to the given number of bytes.

                     onoff=t1,t2,...
                             A list of time stamps when the flow should be activated or
                             deactivated. If onoff is given, the flow is off at startup. At t1,
                             it will be turned on; at t2, it will be turned off, etc.. Time
                             stamps can be given as absolute values (e.g. onoff=0,10,30 - to turn
                             on at t=0, turn off at t=10 and turn on again at t=30 until end of
                             measurement) or relative values (e.g. on=10,+30,+60 - to turn on at
                             t=10, turn off at t=40 and turn on again at t=100 until end of
                             measurement).

                     error_on_abort=on|off
                             By default, the active side stops with an error when a transmission
                             tails (e.g. on connection abort). This parameter turns this
                             behaviour on or off.

                     cmt=off|cmt|cmtrpv1|cmtrpv2|like-mptcp|mptcp-like|mptcp
                             Configures usage of Concurrent Multipath Transfer (CMT): off (turned
                             off; default), cmt (independent paths), cmtrpv1 (CMT/RPv1), cmtrpv1
                             (CMT/RPv2), mptcp/like-mptcp/mptcp-like (MPTCP), 0-255 (custom
                             value).  Currently only supported by CMT-SCTP on FreeBSD systems and
                             MPTCP on Linux systems. Note: CMT for MPTCP always uses MPTCP
                             congestion control.

EXAMPLES

     Some netperfmeter usage examples:

     netperfmeter 9000
             Start in passive mode, i.e. accepting connections, on port 9000.

     netperfmeter 172.16.255.254:9000 -vector=output.vec.bz2 -scalar=output.sca.bz2 -sctp
             const5:exp1000:const3:exp500:description="Alpha":onoff=+10
             const5:exp1000:const3:exp500:description="Beta":onoff=+30 -tcp
             const5:exp1000:const3:exp500:description="Gamma":onoff=+60 -runtime=300
             Start in active mode, i.e. establish connection to 172.16.255.254, port 9000.
             Frames will be segmented into messages of up to 4096 bytes.  Write vectors to
             output.vec.bz2 (BZip2-compressed).  Write scalars to output.sca.bz2
             (BZip2-compressed).  Establish SCTP association.  At t=10s, start flow "Alpha" as
             first stream of this association, using a frame rate of 5 (constant) and average
             frame size of 1000 bytes (negative exponential distribution) for the outgoing data
             and a frame rate of 3 (constant) and average frame size of 500 bytes (negative
             exponential distribution) for the incoming data.  At t=30s, start flow "Beta" as
             second stream on the SCTP association (same parameters as flow "Alpha").  Start TCP
             connection.  At t=60s, start flow "Gamma" over the TCP connection (same parameters
             as flow "Alpha").  At t=300s, stop the measurement.

AUTHORS

     Thomas Dreibholz
     http://www.iem.uni-due.de/~dreibh/netperfmeter
     mailto://dreibh@iem.uni-due.de