Provided by: freeipmi-ipmiseld_1.4.11-1.1ubuntu4.1~0.16.04_amd64 bug

NAME

       ipmiseld.conf - ipmiseld configuration file

DESCRIPTION

       The ipmiseld configuration file configures the ipmiseld daemon.

       The default configuration file loaded is /etc/freeipmi//ipmiseld.conf.

       The  configuration  options  that  can  be  specified in the configuration file are listed
       below. Each configuration option must be listed on  a  separate  line.  Arguments  for  an
       option are separated by any amount of whitespace. Multiple arguments are also separated by
       whitespace.  Comments can be marked by using the pound sign ("#") character, and lines can
       be continued on the next using backslash ("\").

       Note  that  it  is possible to list the username, password and other potentially sensitive
       information in the configuration file. If this data is stored  in  a  configuration  file,
       system administrators should limit access to this file.

IPMISELD CONFIGURATION OPTIONS

       driver-type IPMIDRIVER
              Specify the driver type to use.

       disable-auto-probe ENABLE|DISABLE
              Specify if IPMI devices should be probed for settings.

       driver-address DRIVER-ADDRESS
              Specify the in-band driver address to use.

       driver-device DEVICE
              Specify the in-band driver device path to use.

       register-spacing REGISTER-SPACING
              Specify the in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
              Specify the in-band driver target channel number.

       target-slave-address SLAVE-ADDRESS
              Specify the in-band driver target slave address.

       hostname IPMIHOST1,IPMIHOST2,...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated
              by comma or may be specified in a range format.

       username USERNAME
              Specify the username to use.

       password PASSWORD
              Specify the password to use.

       k_g str
              Specify the BMC key (K_g) to use. Prefix with '0x' to enter the key in hex.

       session-timeout MILLISECONDS
              Specify the session timeout length to use in milliseconds.

       retransmission-timeout MILLISECONDS
              Specify the retransmission timeout length to use in milliseconds.

       authentication-type AUTHENTICATION-TYPE
              Specify the authentication type to use.  The  following  authentication  types  are
              supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.

       cipher-suite-id CIPHER-SUITE-ID
              Specify  the  cipher suite id to use. The following cipher suite ids are supported:
              0, 1, 2, 3, 6, 7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
              Specify the privilege type to use. The following privilege  levels  are  supported:
              USER, OPERATOR, ADMIN.

       workaround-flags WORKAROUNDS
              Specify workaround flags to use. Multiple workarounds can be specified separated by
              whitespace. Please see tool manpages for details about  available  workarounds  for
              each  tool.  The  following  workarounds are supported: assumeio, spinpoll, idzero,
              forcepermsg, unexpectedauth,  endianseq,  authcap,  intel20,  supermicro20,  sun20,
              opensesspriv, integritycheckvalue, assumesystemevent.

       verbose-count COUNT
              Specify default verbose count to use for ipmi-sel(8).

       sensors-types TYPE-LIST
              Specify  sensor  types  of  SEL  events  to  log.  Multiple  types can be specified
              separated by whitespace. Users may specify sensor types  by  string  or  by  number
              (decimal or hex). Please see ipmi-sel(8) --list-types option to see possible string
              input types.

       exclude-sensor-types ENSOR-TYPES-LIST
              Specify sensor types of SEL events to not log. default sensor  types  to  not  show
              sensor outputs for. Multiple sensor types can be specified separated by whitespace.
              Users may specify sensor types by string  or  by  number.  Please  see  ipmi-sel(8)
              --list-types option to see possible string input types.

       system-event-only ENABLE|DISABLE
              Specify if output should only include system event records.

       oem-event-only ENABLE|DISABLE
              Specify if output should only include OEM event records.

       event-state-config-file FILE
              Specify the event state configuration file.

       interpret-oem-data ENABLE|DISABLE
              Specify if ipmiseld should attempt to interpret OEM data or not.

       entity-sensor-names ENABLE|DISABLE
              Specify if output of sensor names should include entity ids and instances or not.

       non-abbreviated-units ENABLE|DISABLE
              Specify if output should have units abbreviated by default or not.

       event-state-filter FILTERSTRING
              Specify event states to be filtered out and not logged.

       --warning-threshold PERCENTINT
              Specify SEL fullness warning threshold as an integer percentage.

       --clear-threshold PERCENTINT
              Specify SEL fullness clear threshold as an integer percentage.

       system-event-format FORMATSTRING
              Specify the format of the log output when a SEL system event is encountered.

       oem-timestamped-event-format FORMATSTRING
              Specify  the  format  of  the  log  output  when  a  SEL  OEM  timestamped event is
              encountered.

       oem-non-timestamped-event-format FORMATSTRING
              Specify the format of the log output  when  a  SEL  OEM  non-timestamped  event  is
              encountered.

       poll-interval SECONDS
              Specify the poll interval to check the SEL for new events.

       log-facility STRING
              Specify the log facility to use.

       log-priority STRING
              Specify the log priority to use.

       cache-directory DIRECTORY
              Specify the cache directory to use.

       ignore-sdr DISABLE
              Specify if the SDR should be ignored.

       re-download-sdr DISABLE
              Specify if the SDR should be re-downloaded on start.

       clear-sel DISABLE
              Specify if the SEL should be cleared on start.

       threadpool-count NUM
              Specify the threadpool count for parallel SEL polling.

FILES

       /etc/freeipmi//ipmiseld.conf

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright (C) 2012-2014 Lawrence Livermore National Security, LLC.

SEE ALSO

       ipmiseld(8), ipmi-sel(8)

       http://www.gnu.org/software/freeipmi/