Provided by: infiniband-diags_1.6.6-1_i386 bug

NAME

       IBSYSSTAT -

SYSTEM STATUS ON AN INFINIBAND ADDRESS

   SYNOPSIS
       ibsysstat [options] <dest lid | guid> [<op>]

   DESCRIPTION
       ibsysstat  uses  vendor  mads to validate connectivity between IB nodes
       and obtain other information about the IB node.  ibsysstat  is  run  as
       client/server. Default is to run as client.

   OPTIONS
       Current supported operations:

          ping \- verify connectivity to server (default)
          host \- obtain host information from server
          cpu  \- obtain cpu information from server

       -o, --oui
              use specified OUI number to multiplex vendor mads

       -S, --Server
              start in server mode (do not return)

   Addressing Flags
       -G, --Guid     The address specified is a Port GUID

       -L, --Lid   The address specified is a LID

       -s, --sm_port <smlid>     use 'smlid' as the target lid for SA queries.

   Port Selection flags
       -C, --Ca <ca_name>    use the specified ca_name.

       -P, --Port <ca_port>    use the specified ca_port.

   Local port Selection
       Multiple  port/Multiple  CA  support:  when  no  IB  device  or port is
       specified (see  the  "local  umad  parameters"  below),  the  libibumad
       library selects the port to use by the following criteria:

          1. the first port that is ACTIVE.

          2. if not found, the first port that is UP (physical link up).

          If  a  port  and/or  CA  name  is  specified,  the libibumad library
          attempts to fulfill the user request, and will fail  if  it  is  not
          possible.

          For example:

              ibaddr                 # use the first port (criteria #1 above)
              ibaddr -C mthca1       # pick the best port from "mthca1" only.
              ibaddr -P 2            # use the second (active/up) port from the first available IB device.
              ibaddr -C mthca0 -P 2  # use the specified port only.

   Debugging flags
       -d     raise  the  IB debugging level.  May be used several times (-ddd
              or -d -d -d).

       -e     show send and receive errors (timeouts and others)

       -h, --help      show the usage message

       -v, --verbose
              increase the application verbosity level.  May be  used  several
              times (-vv or -v -v -v)

       -V, --version     show the version info.

   Configuration flags
       -t,  --timeout  <timeout_ms>  override  the  default  timeout  for  the
       solicited mads.

       --config, -z  <config_file> Specify alternate config file.
          Default: /etc/infiniband-diags/ibdiag.conf

   FILES
   CONFIG FILE
       /etc/infiniband-diags/ibdiag.conf

       A global config file is provided to set some of the common options  for
       all tools.  See supplied config file for details.

   AUTHOR
       Hal Rosenstock
              < halr@voltaire.com >

                                                                  IBSYSSTAT(8)