NAME

       ipmipower - IPMI power control utility

SYNOPSIS

       ipmipower [OPTION...]

DESCRIPTION

       ipmipower  allows  users  to remotely power on, off, cycle, hard reset,
       get a power status query, perform  a  pulse  diagnostic  interrupt,  or
       initiate  a  soft-shutdown of the OS via ACPI through the IPMI over LAN
       protocol.

       When a power command (--on, --off, --cycle, --reset,  --stat,  --pulse,
       or  --soft) is specified on the command line, ipmipower will attempt to
       run the power command on all hostnames listed on the command line  then
       exit.

       If  no power commands are specified on the command line, ipmipower will
       run in interactive mode. Interactive mode gives the user a command line
       interface to enter various commands. Details of the interactive command
       line interface can be found below under INTERACTIVE COMMANDS.

       Listed below are general IPMI options, tool specific  options,  trouble
       shooting  information,  workaround  information,  examples,  and  known
       issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS

       The  following  options  are  general  options  for  configuring   IPMI
       communication and executing general tool commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
              Specify  the  driver  type  to  use  instead  of  doing  an auto
              selection.  The currently available outofband  drivers  are  LAN
              and LAN_2_0, which perform IPMI 1.5 and IPMI 2.0 respectively.

       -h                                             IPMIHOST1,IPMIHOST2,...,
       --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
              Specify  the  remote  host(s)  to  communicate  with.   Multiple
              hostnames  may  be  separated  by comma or may be specified in a
              range format; see HOSTRANGED SUPPORT below. An optional port can
              be  specified  with  each  host,  which  may  be  useful in port
              forwarding or similar situations.

       -u USERNAME, --username=USERNAME
              Specify the username to use when authenticating with the  remote
              host.   If  not  specified,  a null (i.e. anonymous) username is
              assumed. The user must have atleast OPERATOR privileges  to  run
              the  --on,  --off,  --reset,  --cycle,  --pulse, or --soft power
              control commands. The user must have atleast USER privileges  to
              determine the power status of the machine through --stat.

       -p PASSWORD, --password=PASSWORD
              Specify the password to use when authenticationg with the remote
              host.  If not specified, a null  password  is  assumed.  Maximum
              password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt  for  password  to  avoid  possibility  of  listing it in
              process lists.

       -k K_G, --k-g=K_G
              Specify the K_g BMC key to  use  when  authenticating  with  the
              remote  host  for  IPMI  2.0.  If  not  specified, a null key is
              assumed. To input the key in hexadecimal form, prefix the string
              with  '0x'.  E.g.,  the key 'abc' can be entered with the either
              the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of  listing  it  in  process
              lists.

       --session-timeout=MILLISECONDS
              Specify  the  session timeout in milliseconds. Defaults to 20000
              milliseconds (20 seconds) if not specified.

       --retransmission-timeout=MILLISECONDS
              Specify  the  packet  retransmission  timeout  in  milliseconds.
              Defaults to 400 milliseconds (0.4 seconds) if not specified.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
              Specify  the  IPMI 1.5 authentication type to use. The currently
              available authentication types are NONE,  STRAIGHT_PASSWORD_KEY,
              MD2, and MD5. Defaults to MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
              identifies   a   set   of   authentication,    integrity,    and
              confidentiality  algorithms  to  use for IPMI 2.0 communication.
              The authentication algorithm identifies the algorithm to use for
              session  setup, the integrity algorithm identifies the algorithm
              to use for session packet signatures,  and  the  confidentiality
              algorithm   identifies   the   algorithm   to  use  for  payload
              encryption. Defaults to cipher suite ID 3 if not specified.  The
              following cipher suite ids are currently supported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None;
              Confidentiality Algorithm = None

              1 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
              None; Confidentiality Algorithm = None

              2  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
              HMAC-SHA1-96; Confidentiality Algorithm = None

              3 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
              HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

              6  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
              None; Confidentiality Algorithm = None

              7 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
              HMAC-MD5-128; Confidentiality Algorithm = None

              8  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
              HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128

              11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
              MD5-128; Confidentiality Algorithm = None

              12  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
              MD5-128; Confidentiality Algorithm = AES-CBC-128

              15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
              = None; Confidentiality Algorithm = None

              16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
              = HMAC_SHA256_128; Confidentiality Algorithm = None

              17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
              = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify  the privilege level to be used. The currently available
              privilege levels are USER,  OPERATOR,  and  ADMIN.  Defaults  to
              OPERATOR if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify   workarounds  to  vendor  compliance  issues.  Multiple
              workarounds can be specified  separated  by  commas.  A  special
              command  line  flag of "none", will indicate no workarounds (may
              be useful for overriding configured defaults).  See  WORKAROUNDS
              below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMIPOWER OPTIONS

       The following options are specific to ipmipower.

       -n, --on
              Power on the target hosts.

       -f, --off
              Power off the target hosts.

       -c, --cycle
              Power cycle the target hosts.

       -r, --reset
              Reset the target hosts.

       -s, --stat
              Get power status of the target hosts.

       --pulse
              Send power diagnostic interrupt to target hosts.

       --soft Initiate a soft-shutdown of the OS via ACPI.

       --on-if-off
              The  IPMI specification does not require the power cycle or hard
              reset commands to turn on a machine that  is  currently  powered
              off.  This  option  will  force  ipmipower  to  issue a power on
              command instead of a power cycle or hard reset  command  if  the
              remote machine's power is currently off.

       --wait-until-on
              The  IPMI specification allows power on commands to return prior
              to the power on actually taking place. This  option  will  force
              ipmipower  to  regularly  query  the  remote BMC and return only
              after the machine has powered on.

       --wait-until-off
              The IPMI specification allows power off commands to return prior
              the  power  off  actually  taking  place. This option will force
              ipmipower to regularly query the  remote  BMC  and  return  only
              after the machine has powered off.

       --oem-power-type=OEM-POWER-TYPE
              This   option   informs  ipmipower  to  initiate  power  control
              operations via an IPMI OEM specific power control extension. The
              currently  available  POWERTYPEs  are NONE and C410X. Please see
              OEM POWER EXTENSIONS below for additional information.

IPMIPOWER ADVANCED NETWORK OPTIONS

       The following options are used to change  the  networking  behavior  of
       ipmipower.

       --retransmission-wait-timeout=MILLISECONDS
              Specify  the retransmission wait timeout length in milliseconds.
              The retransmission wait timeout is similar to the retransmission
              timeout  above,  but  is  used specifically for power completion
              verification  with  the  --wait-until-on  and   --wait-until-off
              options.  Defaults to 500 milliseconds (0.5 seconds).

       --retransmission-backoff-count=COUNT
              Specify  the  retransmission  backoff count for retransmissions.
              After ever COUNT  retransmissions,  the  retransmission  timeout
              length will be increased by another factor. Defaults to 8.

       --ping-interval=MILLISECONDS
              Specify  the  ping interval length in milliseconds. When running
              in interactive mode, RMCP (Remote Management  Control  Protocol)
              discovery  messages  will be sent to all configured remote hosts
              every MILLISECONDS to  confirm  their  support  of  IPMI.  Power
              commands cannot be sent to a host until it is discovered (or re-
              discovered if previously lost). Defaults to 5000 milliseconds (5
              seconds).  Ping  discovery  messages  can be disabled by setting
              this valu to 0. RMCP ping discovery messages  are  automatically
              disabled in non-interactive mode.

       --ping-timeout=MILLISECONDS
              Specify the ping timeout length in milliseconds. When running in
              interactive mode,  RMCP  (Remote  Management  Control  Protocol)
              messages  discovery  will be sent to all configured remote hosts
              to confirm their support of IPMI. A remote  host  is  considered
              undiscovered  if the host does not respond in MILLISECONDS time.
              Defaults to 30000 milliseconds (30 seconds).  The  ping  timeout
              cannot be larger than the ping interval.

       --ping-packet-count=COUNT
              Specify  the  ping  packet  count  size. Defaults to 10. See the
              --ping-percent-fR option below  for  more  information  on  this
              option.

       --ping-percent=PERCENT
              Specify  the  ping percent value. Defaults to 50.  Since IPMI is
              based on UDP, it  is  difficult  for  ipmipower  to  distinguish
              between  a missing machine and a bad (or heavily loaded) network
              connection in interactive  mode.  when  running  in  interactive
              mode.  For example, suppose a link consistently drops 80% of the
              packets to a particular machine. The power control operation may
              have difficulty completing, although a recent pong response from
              RMCP makes ipmipower believe the machine is up  and  functioning
              properly.   The  ping packet acount and percent options are used
              to alleviate this problem.  Ipmipower  will  monitor  RMCP  ping
              packets  in packet count chunks. If ipmipower does not receive a
              response  to  greater  than  ping  percent  of  those   packets,
              ipmipower  will assume the link to this node is bad and will not
              send power control operations to that node until the  connection
              is  determined to be reliable. This heuristic can be disabled by
              setting either the ping packet count or ping percent to 0.  This
              feature is not used if ping interval is set to 0.

       --ping-consec-count=COUNT
              Specify  the  ping  consecutive count. This is another heuristic
              used to determine if a node  should  be  considered  discovered,
              undiscovered,  or  with  a  bad connection. If a valid RMCP pong
              response was received for the last COUNT ping  packets,  a  node
              will  be  considered  discovered, regardless of other heuristics
              listed above. Defaults to 5. This heuristic can be  disabled  by
              setting  this value to 0. This feature is not used if other ping
              features described above are disabled.

HOSTRANGED OPTIONS

       The following options  manipulate  hostranged  output.  See  HOSTRANGED
       SUPPORT below for additional information on hostranges.

       -B, --buffer-output
              Buffer  hostranged output. For each node, buffer standard output
              until the node has completed its IPMI operation. When specifying
              this  option, data may appear to output slower to the user since
              the the entire IPMI operation must complete before any data  can
              be   output.    See  HOSTRANGED  SUPPORT  below  for  additional
              information.

       -C, --consolidate-output
              Consolidate hostranged output. The complete standard output from
              every  node  specified  will  be consolidated so that nodes with
              identical output are not output twice. A header will list  those
              nodes   with  the  consolidated  output.  When  this  option  is
              specified, no output can be seen until the  IPMI  operations  to
              all  nodes  has completed. If the user breaks out of the program
              early, all currently consolidated output  will  be  dumped.  See
              HOSTRANGED SUPPORT below for additional information.

       -F NUM, --fanout=NUM
              Specify  multiple  host  fanout. Indicates the maximum number of
              power control operations that can be executed in parallel.

       -E, --eliminate
              Eliminate hosts determined as undetected  by  ipmidetect.   This
              attempts  to  remove  the  common  issue of hostranged execution
              timing out due to several nodes being removed from service in  a
              large  cluster.  The  ipmidetectd  daemon must be running on the
              node executing the command.

       --always-prefix
              Always prefix output, even if only  one  host  is  specified  or
              communicating  in-band.  This  option  is  primarily  useful for
              scripting purposes. Option will be ignored if specified with the
              -C option.

INTERACTIVE COMMANDS

       ipmipower provides the following interactive commands at the ipmipower>
       prompt.  Before any power commands (on, off, cycle, reset, stat, pulse,
       or  soft)  can  be  used,  hostnames must be configured into ipmipower,
       either through the command prompt or the hostname  command  below.  The
       parameters  and  options to the commands below mirror their appropriate
       command line options.

       hostname [IPMIHOST(s)]
              Specify a new set of hosts. No input to unconfigure all hosts.

       username [USERNAME]
              Specify a new username. No input for null username.

       password [PASSWORD]
              Specify a new password. No input for null password.

       k_g [K_G]
              Specify a new K_g BMC Key. No input for null  key.  Prefix  with
              '0x' to enter a key in hexadecimal

       ipmi-version IPMIVERSION
              Specify the ipmi version to use.

       session-timeout MILLISECONDS
              Specify a new session timeout length.

       retransmission-timeout MILLISECONDS
              Specify a new retransmiision timeout length.

       authentication-type AUTHENTICATION-TYPE
              Specify the authentication type to use.

       cipher-suite-id CIPHER-SUITE-ID
              Specify the cipher suite id to use.

       privilege-level PRIVILEGE-LEVEL
              Specify the privilege level to use.

       workaround-flags WORKAROUNDS
              Specify workaround flags.

       debug [on|off]
              Toggle debug output.

       on [IPMIHOST(s)]
              Turn on all configured hosts or specified hosts.

       off [IPMIHOST(s)]
              Turn off all configured hosts or specified hosts.

       cycle [IPMIHOST(s)]
              Power cycle all configured hosts or specified hosts.

       reset [IPMIHOST(s)]
              Reset all configured hosts or specified hosts.

       stat [IPMIHOST(s)]
              Query power status for all configured hosts or specified hosts.

       pulse [IPMIHOST(s)]
              Pulse  diagnostic  interrupt  all  configured hosts or specified
              hosts.

       soft [IPMIHOST(s)]
              Initiate a soft-shutdown for all configured hosts  or  specified
              hosts.

       identify-on [IPMIHOST(s)]
              Turn on physical system identification.

       identify-off [IPMIHOST(s)]
              Turn off physical system identification.

       identify-status [IPMIHOST(s)]
              Query physical system identification status.

       on-if-off [on|off]
              Toggle on-if-off functionality.

       wait-until-on [on|off]
              Toggle wait-until-on functionality.

       wait-until-off [on|off]
              Toggle wait-until-off functionality.

       retransmission-wait-timeout MILLISECONDS
              Specify a new retransmission wait timeout length.

       retransmission-backoff-count COUNT
              Specify a new retransmission backoff count.

       ping-interval MILLISECONDS
              Specify a new ping interval length.

       ping-timeout MILLISECONDS
              Specify a new ping timeout length.

       ping-packet-count COUNT
              Specify a new ping packet count.

       ping-percent PERCENT
              Specify a new ping percent.

       ping-consec-count COUNT
              Specify a new ping consec count.

       buffer-output [on|off]
              Toggle buffer-output functionality.

       consolidate-output [on|off]
              Toggle consolidate-output functionality.

       fanout COUNT
              Specify a fanout.

       always-prefix [on|off]
              Toggle always-prefix functionality.

       help   Output help menu.

       version
              Output version.

       config Output the current configuration.

       quit   Quit program.  ipmipower.

OEM POWER EXTENSIONS

       Some  motherboards  include  IPMI  OEM  extensions  for alternate power
       control mechanisms. For example, these  power  control  mechanisms  may
       allow  you  to power control a sub-device within the system rather than
       the entire system itself.

       By specifying an OEM power type via  --oem-power-type  on  the  command
       line  or  freeipmi.conf(5),  you  can  instruct  ipmipower  to  execute
       alternate  power  control  implementations  over  the  standard   ones.
       Depending  on  the  OEM  extension,  some power control commands may no
       longer be available. For example, an OEM extension may allow on but not
       cycle. Specific ipmipower options may not longer function either.

       Some  OEM  extensions  may require additional arguments for their power
       control action, such as a sub-device identifier.  Additional  arguments
       can  be  provided  by  appending  a  plus  sign  ('+')  and  the  extra
       information to the end of the hostname. This can be done on the command
       line  or in interactive mode. For example, the hostname mynode+18 would
       indicate the power control operation should be sent to the host mynode,
       and  18  is  the  identifier  of  a  possible  sub-device  to  be power
       controlled. The --consolidate-output option is commonly  disabled  when
       using an OEM power control that requires extra arguments.

       Because  OEM  power control may involve subtypes, it is possible a user
       may wish to power control multiple sub-devices on the  same  host.  For
       example,  you  might specify the hosts mynode+1,mynode+2, indicating to
       power control subdevice 1 and 2 on mynode.  Because  many  BMCs  cannot
       handle  multiple  IPMI  sessions,  power control operations to the same
       host will be serialized internally by ipmipower.

       The following are the current OEM power  types  available,  along  with
       information  on  the  systems  they  work  with  and  the power control
       operations available.

       C410X  This OEM power type supports the power control of PCIe slots  on
              Dell Poweredge C410x systems. It supports on, off, and stat. The
              PCIe slot number ranges from 1-16 and must always  be  specified
              when  attempting  to  power  control  with  this  extension. For
              example, the hostname mynode+2 would inform ipmipower to operate
              on  slot  number  2  on  mynode.   The  C410x  appears  to  have
              difficulty handling new slot power control requests until  prior
              ones  have  completed. Users may wish to strongly consider using
              the --wait-until-on and  --wait-until-off  options  if  multiple
              slots will be power controlled in short succession.

       NONE   This informs ipmipower that no OEM power type extension is to be
              used and standard IPMI  power  control  is  used.  This  is  the
              default.

HOSTRANGED SUPPORT

       Multiple hosts can be input either as an explicit comma separated lists
       of hosts or a range of hostnames in  the  general  form:  prefix[n-m,l-
       k,...],  where  n  <  m  and  l  < k, etc. The later form should not be
       confused with regular expression character  classes  (also  denoted  by
       []).  For  example, foo[19] does not represent foo1 or foo9, but rather
       represents a degenerate range: foo19.

       This range syntax is meant only as a convenience  on  clusters  with  a
       prefixNN  naming  convention  and specification of ranges should not be
       considered necessary -- the list foo1,foo9 could be specified as  such,
       or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As a reminder to the reader, some shells will interpret brackets ([ and
       ]) for pattern matching. Depending on your shell, it may  be  necessary
       to enclose ranged lists within quotes.

       When multiple hosts are specified by the user, a socket will be created
       for each host and polled on, effectively allowing communication to  all
       hosts  in  parallel.  This will allow communication to large numbers of
       nodes far more quickly than if done  in  serial.   The  -F  option  can
       configure the number of nodes that can be communicated with in parallel
       at the same time.

       By default, standard output from each node  specified  will  be  output
       with  the  hostname  prepended  to  each  line. Although this output is
       readable in many situations, it may  be  difficult  to  read  in  other
       situations.  For  example,  output  from  multiple  nodes  may be mixed
       together. The -B and -C options can be used to change this default.

EXAMPLES

       Determine the power status of foo[0-2] with null username and password
               ipmipower -h foo[0-2] --stat

       Determine the power status  of  foo[0-2]  with  non-null  username  and
       password
               ipmipower -h foo[0-2] -u foo -p bar --stat

       Hard reset nodes foo[0-2] with non-null username and password
               ipmipower -h foo[0-2] -u foo -p bar --reset

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due to configuration problems.

       IPMI  over  LAN  problems  involve  a  misconfiguration  of  the remote
       machine's BMC.  Double check to make sure the following are  configured
       properly  in  the remote machine's BMC: IP address, MAC address, subnet
       mask,  username,  user  enablement,  user  privilege,   password,   LAN
       privilege, LAN enablement, and allowed authentication type(s). For IPMI
       2.0  connections,  double  check  to  make  sure   the   cipher   suite
       privilege(s)  and  K_g  key are configured properly. The ipmi-config(8)
       tool can be used to check and/or change these configuration settings.

       In addition to the troubleshooting tips below, please  see  WORKAROUNDS
       below  to  also  if  there  are any vendor specific bugs that have been
       discovered and worked around.

       Listed below are many of the common issues  for  error  messages.   For
       additional  support, please e-mail the <freeipmi-users@gnu.org> mailing
       list.

       "username invalid" - The username entered (or a NULL username  if  none
       was  entered)  is  not  available on the remote machine. It may also be
       possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password  if  none
       was  entered)  is not correct. It may also be possible the password for
       the user is not correctly configured on the remote BMC.

       "password verification timeout" - Password verification has timed  out.
       A  "password  invalid"  error  (described  above) or a generic "session
       timeout" (described below) occurred.  During this point in the protocol
       it cannot be differentiated which occurred.

       "k_g  invalid"  -  The  K_g  key entered (or a NULL K_g key if none was
       entered) is not correct. It may also be possible the  K_g  key  is  not
       correctly configured on the remote BMC.

       "privilege level insufficient" - An IPMI command requires a higher user
       privilege than the one authenticated with. Please try  to  authenticate
       with a higher privilege. This may require authenticating to a different
       user which has a higher maximum privilege.

       "privilege level cannot be obtained for  this  user"  -  The  privilege
       level  you  are  attempting  to  authenticate  with  is higher than the
       maximum allowed for this user. Please try again with a lower privilege.
       It  may also be possible the maximum privilege level allowed for a user
       is not configured properly on the remote BMC.

       "authentication type unavailable for attempted privilege level"  -  The
       authentication  type you wish to authenticate with is not available for
       this privilege level. Please try again with an alternate authentication
       type  or  alternate  privilege  level.  It  may  also  be  possible the
       available authentication  types  you  can  authenticate  with  are  not
       correctly configured on the remote BMC.

       "cipher  suite  id  unavailable"  -  The  cipher  suite  id you wish to
       authenticate with is not available on the remote BMC. Please try  again
       with  an  alternate  cipher  suite  id.  It  may  also  be possible the
       available cipher suite ids are not correctly configured on  the  remote
       BMC.

       "ipmi  2.0  unavailable"  -  IPMI  2.0 was not discovered on the remote
       machine. Please try to use IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A  number  of
       potential errors are possible, including an invalid hostname specified,
       an IPMI IP address cannot be resolved,  IPMI  is  not  enabled  on  the
       remote  server,  the  network  connection  is  bad,  etc. Please verify
       configuration and connectivity.

       "session timeout" - The IPMI session has timed out.  Please  reconnect.
       If this error occurs often, you may wish to increase the retransmission
       timeout. Some remote BMCs are considerably slower than others.

       "internal IPMI error" - An IPMI error has occurred that  FreeIPMI  does
       not  know  how  to  handle.  Please  e-mail <freeipmi-users@gnu.org> to
       report the issue.

IPMIPOWER TROUBLESHOOTING

       When powering on a powered off machine, the client must have a means by
       which to resolve the MAC address of the remote machine's ethernet card.
       While most modern IPMI solutions support the ability to ARP and resolve
       addresses  when the machine is powered off, some older machines do not.
       This is typically solved in one of two ways:

       1) Enable gratuitous ARPs on the remote  machine.  The  remote  machine
       will  send  out  a gratuitous ARP, which advertises the ethernet IP and
       MAC address so that other machines  on  the  network  this  information
       their  local  ARP  cache.  For  large  clusters,  this  method  is  not
       recommended  since  gratuitous  ARPs  can  flood   the   network   with
       unnecessary traffic.

       2)  Permanently store the remote machine's MAC address in the local ARP
       cache. This is the more common approach on large clusters.

       Other methods are listed in the IPMI specification.

WORKAROUNDS

       With so many different vendors implementing their own  IPMI  solutions,
       different  vendors  may implement their IPMI protocols incorrectly. The
       following describes a number  of  workarounds  currently  available  to
       handle  discovered  compliance  issues. When possible, workarounds have
       been implemented so they will be transparent to the user. However, some
       will  require  the  user  to  specify  a  workaround be used via the -W
       option.

       The hardware listed below may only indicate the hardware that a problem
       was  discovered  on.  Newer  versions  of hardware may fix the problems
       indicated below. Similar machines from vendors may or may  not  exhibit
       the  same  problems.  Different vendors may license their firmware from
       the same IPMI firmware developer,  so  it  may  be  worthwhile  to  try
       workarounds listed below even if your motherboard is not listed.

       If  you  believe  your hardware has an additional compliance issue that
       needs a workaround to  be  implemented,  please  contact  the  FreeIPMI
       maintainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

       authcap  -  This  workaround  flag  will skip early checks for username
       capabilities, authentication capabilities, and K_g  support  and  allow
       IPMI  authentication  to  succeed.  It  works around multiple issues in
       which the remote system does not properly report username capabilities,
       authentication  capabilities,  or  K_g status. Those hitting this issue
       may  see  "username  invalid",  "authentication  type  unavailable  for
       attempted privilege level", or "k_g invalid" errors.  Issue observed on
       Asus  P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
       2200/4150/4450 with ELOM.

       nochecksumcheck  - This workaround flag will tell FreeIPMI to not check
       the checksums returned from IPMI command  responses.  It  works  around
       systems that return invalid checksums due to implementation errors, but
       the packet is otherwise valid. Users are cautioned on the use  of  this
       option,  as  it  removes  validation of packet integrity in a number of
       circumstances.  However,  it  is  unlikely  to  be  an  issue  in  most
       situations.  Those  hitting  this  issue  may see "connection timeout",
       "session timeout", or "password verification timeout" errors.  On  IPMI
       1.5  connections, the "noauthcodecheck" workaround may also needed too.
       Issue  observed  on  Supermicro  X9SCM-iiF,  Supermicro  X9DRi-F,   and
       Supermicro X9DRFR.

       idzero  -  This  workaround  flag  will  allow  empty session IDs to be
       accepted by the client. It works around IPMI sessions that report empty
       session  IDs  to  the client. Those hitting this issue may see "session
       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       unexpectedauth - This workaround flag will  allow  unexpected  non-null
       authcodes  to  be checked as though they were expected. It works around
       an issue when packets contain non-null authentication  data  when  they
       should  be  null  due  to  disabled  per-message  authentication. Those
       hitting this issue may see "session timeout" errors. Issue observed  on
       Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg   -   This   workaround   flag   will   force   per-message
       authentication to be used no matter what is advertised  by  the  remote
       system.  It  works  around  an issue when per-message authentication is
       advertised as disabled  on  the  remote  system,  but  it  is  actually
       required  for  the  protocol. Those hitting this issue may see "session
       timeout" errors.  Issue observed on IBM eServer 325.

       endianseq - This workaround flag will flip the endian  of  the  session
       sequence  numbers  to  allow the session to continue properly. It works
       around IPMI 1.5 session sequence numbers that  are  the  wrong  endian.
       Those  hitting  this  issue  may  see  "session  timeout" errors. Issue
       observed on  some  Sun  ILOM  1.0/2.0  (depends  on  service  processor
       endian).

       noauthcodecheck  - This workaround flag will tell FreeIPMI to not check
       the authentication codes returned from IPMI 1.5 command  responses.  It
       works  around  systems  that return invalid authentication codes due to
       hashing or implementation errors. Users are cautioned  on  the  use  of
       this  option,  as  it  removes  an  authentication  check verifying the
       validity of a packet. However, in most organizations, this is  unlikely
       to  be  a  security issue. Those hitting this issue may see "connection
       timeout", "session timeout", or "password verification timeout" errors.
       Issue   observed   on   Xyratex   FB-H8-SRAY,  Intel  Windmill,  Quanta
       Winterfell, and Wiwynn Windmill.

       intel20 - This workaround flag will work around several Intel IPMI  2.0
       authentication issues. The issues covered include padding of usernames,
       and password  truncation  if  the  authentication  algorithm  is  HMAC-
       MD5-128. Those hitting this issue may see "username invalid", "password
       invalid", or "k_g invalid" errors. Issue observed  on  Intel  SE7520AF2
       with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro
       IPMI 2.0  authentication  issues  on  motherboards  w/  Peppercon  IPMI
       firmware.   The   issues   covered   include  handling  invalid  length
       authentication codes.  Those  hitting  this  issue  may  see  "password
       invalid"  errors.   Issue  observed  on  Supermicro  H8QME  with  SIMSO
       daughter card. Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0
       authentication issues. The issues covered include invalid lengthed hash
       keys, improperly hashed keys, and invalid cipher suite  records.  Those
       hitting  this  issue  may see "password invalid" or "bmc error" errors.
       Issue observed on Sun Fire 4100/4200/4500 with ILOM.   This  workaround
       automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI
       2.0 connection protocol to workaround an invalid hashing algorithm used
       by  the remote system. The privilege level sent during the Open Session
       stage of an IPMI 2.0 connection is used for hashing keys instead of the
       privilege  level  sent during the RAKP1 connection stage. Those hitting
       this issue may see "password invalid", "k_g invalid", or "bad  rmcpplus
       status  code"  errors.   Issue observed on Sun Fire 4100/4200/4500 with
       ILOM, Inventec 5441/Dell Xanadu II, Supermicro X8DTH, Supermicro X8DTG,
       Intel S5500WBV/Penguin Relion 700, Intel S2600JF/Appro 512X, and Quanta
       QSSC-S4R/Appro GB812X-CN. This workaround  is  automatically  triggered
       with the "sun20" workaround.

       integritycheckvalue  - This workaround flag will work around an invalid
       integrity check value during an IPMI  2.0  session  establishment  when
       using  Cipher Suite ID 0. The integrity check value should be 0 length,
       however the remote motherboard responds with a non-empty  field.  Those
       hitting  this  issue  may  see  "k_g invalid" errors. Issue observed on
       Supermicro X8DTG, Supermicro X8DTU, and Intel  S5500WBV/Penguin  Relion
       700, and Intel S2600JF/Appro 512X.

       ipmiping  -  This  workaround  option will inform ipmipower to use IPMI
       based ping packets instead of RMCP ping packets. Some motherboards have
       been  observed  to  not  implement RMCP ping/pong support despite being
       required by the IPMI specification. Issue observed on  Intel  Windmill,
       Quanta Winterfell, and Wiwynn Windmill.

       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
       found to not support IPMI 1.5. Those hitting this issue may  see  "ipmi
       2.0  unavailable"  or  "connection  timeout"  errors. This issue can be
       worked around by using IPMI 2.0  instead  of  IPMI  1.5  by  specifying
       --driver-type=LAN_2_0. Issue observed on HP Proliant DL 145.

DIAGNOSTICS

       Upon  successful  execution, exit status is 0. On error, exit status is
       1.

       If multiple hosts are specified for communication, the exit status is 0
       if  and  only  if  all targets successfully execute. Otherwise the exit
       status is 1.

       When operating in interactive mode, the exit value will be based on the
       last power operation executed.

KNOWN ISSUES

       On  older  operating systems, if you input your username, password, and
       other potentially security relevant information on  the  command  line,
       this information may be discovered by other users when using tools like
       the ps(1) command or looking in the /proc file system. It is  generally
       more  secure  to input password information with options like the -P or
       -K options. Configuring security relevant information in  the  FreeIPMI
       configuration  file  would  also  be  an  appropriate  way to hide this
       information.

       In order to prevent brute force attacks,  some  BMCs  will  temporarily
       "lock  up" after a number of remote authentication errors. You may need
       to wait awhile in order to this temporary "lock up" to pass before  you
       may authenticate again.

       IPMI  specifications  do  not  require  BMCs to perform a power control
       operation before returning a completion code to the caller.  Therefore,
       it is possible for ipmipower to return power status queries opposite of
       what you are expecting.  For example, if a  "power  off"  operation  is
       performed,  a  BMC may return a successful completion code to ipmipower
       before the "power off"  operation  is  actually  performed.  Subsequent
       power status queries may return "on" for several seconds, until the BMC
       actually performs the "power off" operation.

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright (C) 2007-2014 Lawrence Livermore National Security, LLC.
       Copyright (C) 2003-2007 The Regents of the University of California.

       This program is free software; you can redistribute it and/or modify it
       under  the  terms of the GNU General Public License as published by the
       Free Software Foundation; either version 3 of the License, or (at  your
       option) any later version.

SEE ALSO

       freeipmi.conf(5), freeipmi(7), ipmi-config(8), ipmi-oem(8)

       http://www.gnu.org/software/freeipmi/