Provided by: libfabric-dev_1.5.3-1_amd64 bug

NAME

       fi_cntr - Completion and event counter operations

       fi_cntr_open / fi_close : Allocate/free a counter

       fi_cntr_read : Read the current value of a counter

       fi_cntr_readerr : Reads the number of operations which have completed in error.

       fi_cntr_add : Increment a counter by a specified value

       fi_cntr_set : Set a counter to a specified value

       fi_cntr_wait : Wait for a counter to be greater or equal to a threshold value

SYNOPSIS

              #include <rdma/fi_domain.h>

              int fi_cntr_open(struct fid_domain *domain, struct fi_cntr_attr *attr,
                  struct fid_cntr **cntr, void *context);

              int fi_close(struct fid *cntr);

              uint64_t fi_cntr_read(struct fid_cntr *cntr);

              uint64_t fi_cntr_readerr(struct fid_cntr *cntr);

              int fi_cntr_add(struct fid_cntr *cntr, uint64_t value);

              int fi_cntr_adderr(struct fid_cntr *cntr, uint64_t value);

              int fi_cntr_set(struct fid_cntr *cntr, uint64_t value);

              int fi_cntr_seterr(struct fid_cntr *cntr, uint64_t value);

              int fi_cntr_wait(struct fid_cntr *cntr, uint64_t threshold,
                  int timeout);

ARGUMENTS

       domain : Fabric domain

       cntr : Fabric counter

       attr : Counter attributes

       context : User specified context associated with the counter

       value : Value to increment or set counter

       threshold : Value to compare counter against

       timeout : Time in milliseconds to wait.  A negative value indicates infinite timeout.

DESCRIPTION

       Counters  record  the  number  of  requested operations that have completed.  Counters can
       provide a light-weight completion mechanism  by  suppressing  the  generation  of  a  full
       completion  event.   They are useful for applications that only need to know the number of
       requests that have completed, and not details about each request.  For  example,  counters
       may  be useful for implementing credit based flow control or tracking the number of remote
       processes which have responded to a request.

       Counters typically only count successful completions.  However, if an operation  completes
       in  error, it may increment an associated error value.  That is, a counter actually stores
       two distinct values, with error completions updating an error specific value.

   fi_cntr_open
       fi_cntr_open allocates a new fabric counter.  The properties and behavior of  the  counter
       are defined by struct fi_cntr_attr.

              struct fi_cntr_attr {
                  enum fi_cntr_events  events;    /* type of events to count */
                  enum fi_wait_obj     wait_obj;  /* requested wait object */
                  struct fid_wait     *wait_set;  /* optional wait set */
                  uint64_t             flags;     /* operation flags */
              };

       events  :  A  counter  captures  different types of events.  The specific type which is to
       counted are one of the following:

       • FI_CNTR_EVENTS_COMP : The counter increments for every successful completion that occurs
         on  an  associated  bound endpoint.  The type of completions -- sends and/or receives --
         which are counted may be restricted using control flags when binding the counter and the
         endpoint.  Counters increment on all successful completions, separately from whether the
         operation generates an entry in an event queue.

       wait_obj : Counters may be associated with a specific wait  object.   Wait  objects  allow
       applications  to  block  until  the wait object is signaled, indicating that a counter has
       reached a specific threshold.  Users may use fi_control to retrieve  the  underlying  wait
       object associated with a counter, in order to use it in other system calls.  The following
       values may be used to  specify  the  type  of  wait  object  associated  with  a  counter:
       FI_WAIT_NONE,   FI_WAIT_UNSPEC,  FI_WAIT_SET,  FI_WAIT_FD,  and  FI_WAIT_MUTEX_COND.   The
       default is FI_WAIT_NONE.

       • FI_WAIT_NONE : Used to indicate that the user will not block (wait) for  events  on  the
         counter.

       • FI_WAIT_UNSPEC  :  Specifies  that  the  user will only wait on the counter using fabric
         interface calls, such as fi_cntr_wait.  In this case, the underlying provider may select
         the  most appropriate or highest performing wait object available, including custom wait
         mechanisms.  Applications that select FI_WAIT_UNSPEC are not guaranteed to retrieve  the
         underlying wait object.

       • FI_WAIT_SET  : Indicates that the event counter should use a wait set object to wait for
         events.  If specified, the wait_set field must reference an existing wait set object.

       • FI_WAIT_FD : Indicates that the counter  should  use  a  file  descriptor  as  its  wait
         mechanism.   A  file  descriptor  wait  object must be usable in select, poll, and epoll
         routines.  However, a provider may signal an FD wait object by marking it  as  readable,
         writable, or with an error.

       • FI_WAIT_MUTEX_COND  :  Specifies  that  the  counter should use a pthread mutex and cond
         variable as a wait object.

       wait_set : If wait_obj is FI_WAIT_SET, this field references a wait object  to  which  the
       event  counter  should  attach.   When  an  event  is  added  to  the  event  counter, the
       corresponding wait set will be signaled if all necessary conditions are met.  The use of a
       wait_set enables an optimized method of waiting for events across multiple event counters.
       This field is ignored if wait_obj is not FI_WAIT_SET.

       flags : Flags are reserved for future use, and must be set to 0.

   fi_close
       The fi_close call releases all resources associated with  a  counter.   When  closing  the
       counter,  there must be no opened endpoints, transmit contexts, receive contexts or memory
       regions associated with the counter.  If resources are still associated with  the  counter
       when attempting to close, the call will return -FI_EBUSY.

   fi_cntr_control
       The  fi_cntr_control call is used to access provider or implementation specific details of
       the  counter.   Access  to  the  counter  should  be  serialized  across  all  calls  when
       fi_cntr_control  is  invoked, as it may redirect the implementation of counter operations.
       The following control commands are usable with a counter:

       FI_GETOPSFLAG (uint64_t *) : Returns the current default operational flags associated with
       the counter.

       FI_SETOPSFLAG  (uint64_t  *)  :  Modifies the current default operational flags associated
       with the counter.

       FI_GETWAIT (void **) : This command allows the user to retrieve the low-level wait  object
       associated  with  the  counter.  The format of the wait-object is specified during counter
       creation, through the counter attributes.  See fi_eq.3 for addition details using  control
       with FI_GETWAIT.

   fi_cntr_read
       The fi_cntr_read call returns the current value of the counter.

   fi_cntr_readerr
       The  read  error  call  returns  the number of operations that completed in error and were
       unable to update the counter.

   fi_cntr_add
       This adds the user-specified value to the counter.

   fi_cntr_adderr
       This adds the user-specified value to the error value of the counter.

   fi_cntr_set
       This sets the counter to the specified value.

   fi_cntr_seterr
       This sets the error value of the counter to the specified value.

   fi_cntr_wait
       This call may be used to wait until the counter reaches the specified threshold, or  until
       an  error  or  timeout occurs.  Upon successful return from this call, the counter will be
       greater than or equal to the input threshold value.

       If an operation associated with the counter encounters an error,  it  will  increment  the
       error  value  associated  with  the  counter.   Any change in a counter's error value will
       unblock any thread inside fi_cntr_wait.

       If the call returns due to timeout, -FI_ETIMEDOUT  will  be  returned.   The  error  value
       associated with the counter remains unchanged.

       It  is  invalid  for applications to call this function if the counter has been configured
       with a wait object of FI_WAIT_NONE or FI_WAIT_SET.

RETURN VALUES

       Returns 0 on success.  On error,  a  negative  value  corresponding  to  fabric  errno  is
       returned.

       fi_cntr_read / fi_cntr_readerr : Returns the current value of the counter.

       Fabric errno values are defined in rdma/fi_errno.h.

NOTES

SEE ALSO

       fi_getinfo(3), fi_endpoint(3), fi_domain(3), fi_eq(3), fi_poll(3)

AUTHORS

       OpenFabrics.