Provided by: euca2ools_3.3.1-1_all 

NAME
euwatch-put-metric-alarm - Create or update an alarm
SYNOPSIS
euwatch-put-metric-alarm --comparison-operator
{GreaterThanOrEqualToThreshold,GreaterThanThreshold,LessThanThreshold,LessThanOrEqualToThreshold}
--evaluation-periods COUNT --metric-name METRIC --namespace NAMESPACE --period SECONDS --statistic
{Average,Maximum,Minimum,SampleCount,Sum} --threshold FLOAT [--actions-enabled {true,false}]
[--alarm-actions ARN1,ARN2,...] [--alarm-description DESCRIPTION] [-d
KEY1=VALUE1,KEY2=VALUE2,...] [--insufficient-data-actions ARN1,ARN2,...] [--ok-actions
ARN1,ARN2,...] [--unit UNIT] [--show-empty-fields] [-U URL] [--region USER@REGION] [-I KEY_ID] [-S
KEY] [--security-token TOKEN] [--debug] [--debugger] [--version] [-h] ALARM
DESCRIPTION
Create or update an alarm
positional arguments:
ALARM name of the alarm (required)
optional arguments:
--comparison-operator
{GreaterThanOrEqualToThreshold,GreaterThanThreshold,LessThanThreshold,LessThanOrEqualToThreshold}
arithmetic operator with which the comparison with the threshold will be made (required)
--evaluation-periods COUNT
number of consecutive periods for which the value of the metric needs to be compared to the
threshold (required)
--metric-name METRIC
name for the alarm's associated metric (required)
--namespace NAMESPACE
namespace for the alarm's associated metric (required)
--period SECONDS
period over which the specified statistic is applied (required)
--statistic {Average,Maximum,Minimum,SampleCount,Sum}
statistic on which to alarm (required)
--threshold FLOAT
value to compare the statistic against (required)
--actions-enabled {true,false}
whether this alarm's actions should be executed when it changes state
--alarm-actions ARN1,ARN2,...
ARNs of SNS topics to publish to when the alarm changes to the ALARM state
--alarm-description DESCRIPTION
description of the alarm
-d KEY1=VALUE1,KEY2=VALUE2,..., --dimensions KEY1=VALUE1,KEY2=VALUE2,...
dimensions for the alarm's associated metric
--insufficient-data-actions ARN1,ARN2,...
ARNs of SNS topics to publish to when the alarm changes to the INSUFFICIENT_DATA state
--ok-actions ARN1,ARN2,...
ARNs of SNS topics to publish to when the alarm changes to the OK state
--unit UNIT
unit for the alarm's associated metric
--show-empty-fields
show empty values as "(nil)"
-U URL, --url URL
instance monitoring service endpoint URL
--region USER@REGION
region and/or user names to search when looking up config file data
-I KEY_ID, --access-key-id KEY_ID
-S KEY, --secret-key KEY
--security-token TOKEN
--debug
show debugging output
--debugger
launch interactive debugger on error
--version
show the program's version and exit
-h, --help
show this help message and exit
euca2ools 3.3 March 2016 EUWATCH-PUT-METRIC-ALARM(1)