Provided by: otb-bin-qt_6.4.0+dfsg-1_amd64 bug

NAME

       otbgui_SarRadiometricCalibration - OTB SarRadiometricCalibration application

DESCRIPTION

       This  is  the SarRadiometricCalibration application, version 5.2.0 Perform radiometric calibration of SAR
       images.  Following  sensors  are  supported:  TerraSAR-X,  Sentinel1  and  Radarsat-2.Both  Single   Look
       Complex(SLC) and detected products are supported as input.

       Complete documentation: http://www.orfeo-toolbox.org/Applications/SarRadiometricCalibration.html

   Parameters:
       -progress <boolean>
              Report progress

        -in       <string>         Input Image  (mandatory)
        -out       <string>  [pixel] Output Image  [pixel=uint8/uint16/int16/uint32/int32/float/double] (default
       value is float) (mandatory)

       -ram   <int32>          Available RAM (Mb)  (optional, off by default, default value is 128)

       -noise <boolean>        Disable Noise  (optional, off by default)

       -lut   <string>         Lookup table sigma /gamma/ beta/ DN.  [sigma/gamma/beta/dn]  (mandatory,  default
              value is sigma)

       -inxml <string>         Load otb application from xml file  (optional, off by default)

EXAMPLES

       otbgui_SarRadiometricCalibration -in RSAT_imagery_HH.tif -out SarRadiometricCalibration.tif

SEE ALSO

       The  full  documentation  for otbgui_SarRadiometricCalibration is maintained as a Texinfo manual.  If the
       info and otbgui_SarRadiometricCalibration programs are properly installed at your site, the command

              info otbgui_SarRadiometricCalibration

       should give you access to the complete manual.

otbgui_SarRadiometricCalibration 5.2.0            December 2015              OTBGUI_SARRADIOMETRICCALIBRATION(1)