bionic (7) vmmosobsstare.7.gz

Provided by: cpl-plugin-vimos-doc_3.1.9+dfsg-1build1_all bug

NAME

       vmmosobsstare - Reduce a MOS science exposure.

SYNOPSIS

       esorex vmmosobsstare [OPTIONS] FILE.sof

DESCRIPTION

       This  recipe  is used to apply basic reduction steps to one exposure made in MOS mode, to locate objects,
       and to optimally extract their spectra.

       Input files:

         DO category:             Type:       Explanation:         Required:
         MOS_SCIENCE              Raw         Science exposure        Y
         MASTER_BIAS              Calib       Master bias             Y
         MASTER_DARK              Calib       Master dark             .

         MOS_MASTER_SCREEN_FLAT   Calib       Normalised flat field   .

         EXTRACT_TABLE            Calib       Extraction table        .

         GRISM_TABLE              Calib       Grism table             Y
         EXTINCT_TABLE            Calib       Atmospheric extinction  .

         MOS_SPECPHOT_TABLE       Calib       Response curve          .

         CCD_TABLE                Calib       Bad pixel table         .

       Output files:

         DO category:             Data type:  Explanation:
         MOS_SCIENCE_REDUCED      FITS image  Extracted objects spectra
         MOS_SCIENCE_FLUX_REDUCED FITS image  Flux calibrated objects spectra
         MOS_SCIENCE_EXTRACTED    FITS image  Sky subtracted slit spectra
         MOS_SCIENCE_SKY          FITS image  Sky spectra
         MOS_SKY_REDUCED          FITS image  Extracted sky spectra
         OBJECT_TABLE             FITS table  Objects spectra identification
         WINDOW_TABLE             FITS table  Objects positions in slit

       A flat field correction is applied only if a  normalised  master  flat  field  (produced  by  the  recipe
       vmspflat) is specified.

       The  extraction  table is the product of the local spectral distortions modelling performed by the recipe
       vmspcaldisp. If an extraction table is not specified, then the global distortion  models  read  from  the
       science frame header are used.

       The  grism  table  contains necessary information to control the way spectra are extracted, starting from
       the reference wavelength (header entry PRO WLEN CEN), on a specific range of pixels above and  below  its
       position  on  the CCD (header entries PRO SPECT LLEN LO and PRO SPECT LLEN HI). Other parameters, used in
       the extraction of the science slit spectra, are the start and the end wavelength  of  the  image  of  the
       extracted  slit  spectra  (header  entries PRO WLEN START and PRO WLEN END), and the step of the sampling
       along the dispersion direction (header entry PRO WLEN INC). Finally, the wavelengths  of  the  sky  lines
       used  in  the  alignment  of  the spectral distortion models, necessary to keep into account the possible
       coordinates shifts introduced by a variation of the instrument  flexures  between  the  science  and  the
       calibration  exposures,  are  listed  in  the header keywords PRO SKY WLENi, with i ranging from 1 to the
       number specified in the keyword PRO SKY NO.

       A CCD table must be specified in input only if a bad pixel cleaning is requested.

       The slit spectra are remapped with the instrument distortions removed and at a fixed wavelength  step.  A
       sky value is estimated for each wavelength and then subtracted from the data. The result is stored in the
       MOS_SCIENCE_EXTRACTED image, while the image MOS_SCIENCE_SKY contains the subtracted sky  model.  The  1D
       extracted  spectra  are  stored  in  the  MOS_SCIENCE_REDUCED  image, while the corresponding sky spectra
       extracted with the same method are stored in the MOS_SKY_REDUCED image.

       The positions of the extracted slit spectra and of the detected objects that they may contain are  listed
       in the window table.

       If  a  spectro-photometric  table  (produced  by  the recipe vmmosstandard) is specified together with an
       atmospheric extinction table, and a flux calibration is requested, then a MOS_SCIENCE_FLUX_REDUCED  image
       is also created. This image is identical to the MOS_SCIENCE_REDUCED, but the spectra it contains are flux
       calibrated, and expressed in units of erg/cm/cm/s/Angstrom.

       For more details, please refer to the VIMOS Pipeline User´s Guide.

OPTIONS

       --BiasMethod <str>
              Bias removal method. (str; default: ´Zmaster´). The full  name  of  this  option  for  the  EsoRex
              configuration file is vimos.Parameters.bias.removing.method [default = Zmaster].

       --SkyMethod <str>
              Sky  level  determination  method.  (str; default: ´Median´). The full name of this option for the
              EsoRex configuration file is vimos.Parameters.sky.method [default = Median].

       --PolyOrder <long>
              Degree of polynomial used when the SkyMethod is set to Fit. (long; default: 0). The full  name  of
              this option for the EsoRex configuration file is vimos.Parameters.sky.order [default = 0].

       --SkyKSigmaLow <float>
              Low  threshold  for K-sigma rejection in sky fitting. (float; default: 1.0). The full name of this
              option for the EsoRex configuration file is vimos.Parameters.sky.ksigma.low [default = 1.0].

       --SkyKSigmaHigh <float>
              High threshold for K-sigma rejection in sky fitting. (float; default: 1.0). The full name of  this
              option for the EsoRex configuration file is vimos.Parameters.sky.ksigma.high [default = 1.0].

       --Fuzz <long>
              Extra  pixels from expected position of spectrum edge in extraction.  (long; default: 5). The full
              name of this option for the EsoRex configuration file is vimos.Parameters.extraction.fuzz [default
              = 5].

       --SlitMargin <long>
              Number  of  excluded  pixels  at  slit ends in object search or in sky level determination. (long;
              default:  2).  The  full  name  of  this   option   for   the   EsoRex   configuration   file   is
              vimos.Parameters.detection.exclude [default = 2].

       --LineWidth <long>
              Size  of spectrum to extract around any skyline. (long; default: 16). The full name of this option
              for the EsoRex configuration file is vimos.Parameters.sky.linewidth [default = 16].

       --DetectionLevel <float>
              Object detection level in units of sigma. (float; default: 2.0). The full name of this option  for
              the EsoRex configuration file is vimos.Parameters.detection.sigma [default = 2.0].

       --WatershedLevels <long>
              Number  of  levels in the watershed method in object detection. (long; default: 32). The full name
              of this option for the EsoRex configuration file is vimos.Parameters.detection.levels  [default  =
              32].

       --WatershedFraction <float>
              Flux  fraction  to  use in watershed. (float; default: 0.01). The full name of this option for the
              EsoRex configuration file is vimos.Parameters.detection.fraction [default = 0.01].

       --MinObjectSize <long>
              Minimal size for an object candidate to be considered an object.  (long;  default:  2).  The  full
              name  of  this  option  for  the  EsoRex  configuration file is vimos.Parameters.detection.minsize
              [default = 2].

       --MaxObjectSize <long>
              Maximal size for an object candidate for not trying deblend into sub- objects. (long; default: 7).
              The    full    name    of    this    option    for    the    EsoRex    configuration    file    is
              vimos.Parameters.detection.maxsize [default = 7].

       --CleanBadPixel <bool>
              Bad pixel correction on MOS science exposure. (bool; default: False). The full name of this option
              for the EsoRex configuration file is vimos.Parameters.badpixel.clean [default = False].

       --CalibrateFlux <bool>
              Extracted  spectra  are  flux calibrated. (bool; default: False). The full name of this option for
              the EsoRex configuration file is vimos.Parameters.flux.calibration [default = False].

       --HorneExtraction <bool>
              Use 1D Horne extraction. (bool; default: False). The full name  of  this  option  for  the  EsoRex
              configuration file is vimos.Parameters.extraction.optimal [default = False].

       --ModelSlit <bool>
              Model  wavelength  solution  within each slit. (bool; default: True). The full name of this option
              for the EsoRex configuration file is vimos.Parameters.slit.model [default = True].

       --ModelSlitOrder <long>
              Order of polynomial for wavelength solution modeling within each slit.  (long;  default:  0).  The
              full name of this option for the EsoRex configuration file is vimos.Parameters.slit.order [default
              = 0].

       --UseSkylines <bool>
              Use sky lines to refine the wavelength calibration (bool; default: True). The full  name  of  this
              option for the EsoRex configuration file is vimos.Parameters.sky.align [default = True].

       Note  that  it  is  possible to create a configuration file containing these options, along with suitable
       default values. Please refer to the details provided by the 'esorex --help' command.

SEE ALSO

       The full documentation for the vimos pipeline can be downloaded as a PDF file using the following URL:

              ftp://ftp.eso.org/pub/dfs/pipelines/vimos/vimos-pipeline-manual-6.9.pdf

       An   overview   over   the   existing   ESO   pipelines    can    be    found    on    the    web    page
       http://www.eso.org/sci/software/pipelines/.

       Basic documentation about the EsoRex program can be found at the esorex (1) man page.

       It   is   possible   to   call   the   pipelines   from   python   using  the  python-cpl  package.   See
       http://packages.python.org/python-cpl/index.html for further information.

       The  other  recipes  of  the  vimos  pipeline  are   vmbias(7),   vmdark(7),   vmdet(7),   vmifucalib(7),
       vmifucombine(7),      vmifucombinecube(7),     vmifuscience(7),     vmifustandard(7),     vmimcalphot(7),
       vmimflatscreen(7), vmimflatsky(7), vmimobsjitter(7), vmimobsstare(7), vmimpreimaging(7), vmimstandard(7),
       vmmoscalib(7),  vmmoscombine(7),  vmmosobsjitter(7),  vmmosscience(7),  vmmosstandard(7), vmspcaldisp(7),
       vmspflat(7), vmspphot(7)

VERSION

       vmmosobsstare 3.1.9

AUTHOR

       ESO VIMOS Pipeline Team and VIMOS Consortium <usd-help@eso.org>

BUG REPORTS

       Please report any problems to usd-help@eso.org. Alternatively, you may send a  report  to  the  ESO  User
       Support Department <usd-help@eso.org>.

LICENSE

       This file is part of the VIMOS Instrument Pipeline Copyright (C) 2002-2005 European Southern Observatory

       This  program  is  free  software;  you  can  redistribute it and/or modify it under the terms of the GNU
       General Public License as published by the Free Software Foundation; either version 2 of the License,  or
       (at your option) any later version.

       This  program  is  distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even
       the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU  General  Public
       License for more details.

       You  should have received a copy of the GNU General Public License along with this program; if not, write
       to the Free Software Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA  02110-1301 USA