NAME

       bmc-info - display BMC information

SYNOPSIS

       bmc-info [OPTION...]

DESCRIPTION

       Bmc-info  displays  BMC  information,  such as device version numbers, device support, and
       globally unique IDs (guids).

       Listed  below  are  general  IPMI  options,  tool  specific  options,   trouble   shooting
       information,   workaround   information,   examples,  and  known  issues.  For  a  general
       introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS

       The following options are general options for configuring IPMI communication and executing
       general tool commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
              Specify  the  driver type to use instead of doing an auto selection.  The currently
              available outofband drivers are LAN and LAN_2_0, which perform IPMI  1.5  and  IPMI
              2.0  respectively.  The currently available inband drivers are KCS, SSIF, OPENIPMI,
              SUNBMC, and INTELDCMI.

       --disable-auto-probe
              Do not probe in-band IPMI devices for default settings.

       --driver-address=DRIVER-ADDRESS
              Specify the in-band driver address to be used instead of the probed value.  DRIVER-
              ADDRESS should be prefixed with "0x" for a hex value and '0' for an octal value.

       --driver-device=DEVICE
              Specify the in-band driver device path to be used instead of the probed path.

       --register-spacing=REGISTER-SPACING
              Specify  the  in-band driver register spacing instead of the probed value. Argument
              is in bytes (i.e. 32bit register spacing = 4)

       --target-channel-number=CHANNEL-NUMBER
              Specify the in-band driver target channel number to send IPMI requests to.

       --target-slave-address=SLAVE-ADDRESS
              Specify the in-band driver target slave number to send IPMI requests to.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated
              by  comma  or  may be specified in a range format; see HOSTRANGED SUPPORT below. An
              optional port can be specified  with  each  host,  which  may  be  useful  in  port
              forwarding or similar situations.

       -u USERNAME, --username=USERNAME
              Specify  the  username  to  use  when  authenticating with the remote host.  If not
              specified, a null (i.e. anonymous) username is assumed. The user must have  atleast
              USER privileges in order for this tool to operate fully.

       -p PASSWORD, --password=PASSWORD
              Specify  the  password  to  use  when authenticationg with the remote host.  If not
              specified, a null password is assumed. Maximum password length is 16 for  IPMI  1.5
              and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password to avoid possibility of listing it in process lists.

       -k K_G, --k-g=K_G
              Specify  the  K_g  BMC key to use when authenticating with the remote host for IPMI
              2.0. If not specified, a null key is assumed. To input the key in hexadecimal form,
              prefix the string with '0x'. E.g., the key 'abc' can be entered with the either the
              string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of listing it in process lists.

       --session-timeout=MILLISECONDS
              Specify the session timeout in milliseconds. Defaults  to  20000  milliseconds  (20
              seconds) if not specified.

       --retransmission-timeout=MILLISECONDS
              Specify  the  packet  retransmission  timeout  in  milliseconds.  Defaults  to 1000
              milliseconds (1 second) if not specified.  The  retransmission  timeout  cannot  be
              larger than the session timeout.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
              Specify   the  IPMI  1.5  authentication  type  to  use.  The  currently  available
              authentication types are NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5. Defaults to MD5
              if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
              Specify  the  IPMI 2.0 cipher suite ID to use. The Cipher Suite ID identifies a set
              of authentication, integrity, and confidentiality algorithms to use  for  IPMI  2.0
              communication.  The  authentication  algorithm  identifies the algorithm to use for
              session setup, the integrity algorithm identifies the algorithm to use for  session
              packet  signatures,  and  the confidentiality algorithm identifies the algorithm to
              use for payload encryption. Defaults to cipher suite ID 3  if  not  specified.  The
              following cipher suite ids are currently supported:

              0  -  Authentication  Algorithm = None; Integrity Algorithm = None; Confidentiality
              Algorithm = None

              1  -  Authentication  Algorithm  =   HMAC-SHA1;   Integrity   Algorithm   =   None;
              Confidentiality Algorithm = None

              2  -  Authentication  Algorithm  =  HMAC-SHA1;  Integrity Algorithm = HMAC-SHA1-96;
              Confidentiality Algorithm = None

              3 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm  =  HMAC-SHA1-96;
              Confidentiality Algorithm = AES-CBC-128

              6   -   Authentication   Algorithm   =   HMAC-MD5;   Integrity  Algorithm  =  None;
              Confidentiality Algorithm = None

              7 - Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm  =  HMAC-MD5-128;
              Confidentiality Algorithm = None

              8  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm = HMAC-MD5-128;
              Confidentiality Algorithm = AES-CBC-128

              11  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm   =   MD5-128;
              Confidentiality Algorithm = None

              12   -   Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm  =  MD5-128;
              Confidentiality Algorithm = AES-CBC-128

              15  -  Authentication  Algorithm  =  HMAC-SHA256;  Integrity  Algorithm   =   None;
              Confidentiality Algorithm = None

              16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm = HMAC_SHA256_128;
              Confidentiality Algorithm = None

              17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm = HMAC_SHA256_128;
              Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify  the  privilege  level to be used. The currently available privilege levels
              are USER, OPERATOR, and ADMIN. Defaults to USER if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify workarounds to  vendor  compliance  issues.  Multiple  workarounds  can  be
              specified separated by commas. A special command line flag of "none", will indicate
              no workarounds (may be useful for overriding configured defaults). See  WORKAROUNDS
              below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

BMC-INFO OPTIONS

       The following options are specific to Bmc-info.

       --get-device-id
              Display only device ID information.

       --get-device-guid
              Display only device guid.

       --get-system-guid
              Display only system guid.

       --get-system-info
              Display only system info.

       --get-channel-info
              Display only channel information.

       --interpret-oem-data
              Attempt  to  interpret  OEM  data,  such as event data, sensor readings, or general
              extra info, etc. If an OEM interpretation is not available, the default output will
              be  generated.  Correctness  of  OEM  interpretations  cannot  be guaranteed due to
              potential changes OEM  vendors  may  make  in  products,  firmware,  etc.  See  OEM
              INTERPRETATION below for confirmed supported motherboard interpretations.

HOSTRANGED OPTIONS

       The  following  options  manipulate  hostranged  output.  See HOSTRANGED SUPPORT below for
       additional information on hostranges.

       -B, --buffer-output
              Buffer hostranged output. For each node, buffer standard output until the node  has
              completed  its  IPMI  operation.  When  specifying  this option, data may appear to
              output slower to the user since the the entire IPMI operation must complete  before
              any data can be output.  See HOSTRANGED SUPPORT below for additional information.

       -C, --consolidate-output
              Consolidate  hostranged  output.  The  complete  standard  output  from  every node
              specified will be consolidated so that nodes with identical output are  not  output
              twice.  A  header  will  list  those  nodes with the consolidated output. When this
              option is specified, no output can be seen until the IPMI operations to  all  nodes
              has  completed.  If  the  user  breaks  out  of  the  program  early, all currently
              consolidated output will be dumped. See HOSTRANGED  SUPPORT  below  for  additional
              information.

       -F NUM, --fanout=NUM
              Specify  multiple host fanout. A "sliding window" (or fanout) algorithm is used for
              parallel IPMI communication so that slower nodes or timed out nodes will not impede
              parallel communication. The maximum number of threads available at the same time is
              limited by the fanout. The default is 64.

       -E, --eliminate
              Eliminate hosts determined as undetected by ipmidetect.  This  attempts  to  remove
              the  common  issue  of  hostranged  execution timing out due to several nodes being
              removed from service in a large cluster. The ipmidetectd daemon must be running  on
              the node executing the command.

       --always-prefix
              Always  prefix output, even if only one host is specified or communicating in-band.
              This option is primarily useful for scripting purposes. Option will be  ignored  if
              specified with the -C option.

HOSTRANGED SUPPORT

       Multiple  hosts  can  be  input  either as an explicit comma separated lists of hosts or a
       range of hostnames in the general form: prefix[n-m,l-k,...], where n < m and l <  k,  etc.
       The  later  form  should  not  be confused with regular expression character classes (also
       denoted by []). For  example,  foo[19]  does  not  represent  foo1  or  foo9,  but  rather
       represents a degenerate range: foo19.

       This  range  syntax  is  meant  only  as  a convenience on clusters with a prefixNN naming
       convention and specification of ranges should not be  considered  necessary  --  the  list
       foo1,foo9 could be specified as such, or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As  a  reminder  to  the reader, some shells will interpret brackets ([ and ]) for pattern
       matching. Depending on your shell, it may be necessary  to  enclose  ranged  lists  within
       quotes.

       When  multiple hosts are specified by the user, a thread will be executed for each host in
       parallel up to the configured fanout (which can be adjusted via the -F option). This  will
       allow communication to large numbers of nodes far more quickly than if done in serial.

       By  default,  standard  output  from  each node specified will be output with the hostname
       prepended to each line. Although this output is readable in many  situations,  it  may  be
       difficult  to  read  in  other  situations. For example, output from multiple nodes may be
       mixed together. The -B and -C options can be used to change this default.

       In-band IPMI Communication will be used when  the  host  "localhost"  is  specified.  This
       allows the user to add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due to configuration problems.

       IPMI  over  LAN  problems  involve a misconfiguration of the remote machine's BMC.  Double
       check to make sure the following are configured properly in the remote machine's  BMC:  IP
       address,  MAC  address,  subnet mask, username, user enablement, user privilege, password,
       LAN  privilege,  LAN  enablement,  and  allowed  authentication  type(s).  For  IPMI   2.0
       connections,  double  check  to  make  sure  the cipher suite privilege(s) and K_g key are
       configured properly. The ipmi-config(8) tool can be used  to  check  and/or  change  these
       configuration settings.

       Inband IPMI problems are typically caused by improperly configured drivers or non-standard
       BMCs.

       In addition to the troubleshooting tips below, please see WORKAROUNDS  below  to  also  if
       there are any vendor specific bugs that have been discovered and worked around.

       Listed  below  are  many of the common issues for error messages.  For additional support,
       please e-mail the <freeipmi-users@gnu.org> mailing list.

       "username invalid" - The username entered (or a NULL username if none was entered) is  not
       available  on  the  remote  machine.  It  may  also  be possible the remote BMC's username
       configuration is incorrect.

       "password invalid" - The password entered (or a NULL password if none was entered) is  not
       correct.  It may also be possible the password for the user is not correctly configured on
       the remote BMC.

       "password verification timeout" -  Password  verification  has  timed  out.   A  "password
       invalid"  error  (described  above)  or  a  generic  "session  timeout"  (described below)
       occurred.  During this point in the protocol it cannot be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL  K_g  key  if  none  was  entered)  is  not
       correct.  It  may  also  be possible the K_g key is not correctly configured on the remote
       BMC.

       "privilege level insufficient" - An IPMI command requires a higher user privilege than the
       one  authenticated  with.  Please  try  to  authenticate with a higher privilege. This may
       require authenticating to a different user which has a higher maximum privilege.

       "privilege level cannot be  obtained  for  this  user"  -  The  privilege  level  you  are
       attempting  to  authenticate with is higher than the maximum allowed for this user. Please
       try again with a lower privilege. It may also be  possible  the  maximum  privilege  level
       allowed for a user is not configured properly on the remote BMC.

       "authentication  type unavailable for attempted privilege level" - The authentication type
       you wish to authenticate with is not available for this privilege level. Please try  again
       with  an  alternate  authentication  type  or  alternate  privilege  level. It may also be
       possible the available authentication types you can authenticate with  are  not  correctly
       configured on the remote BMC.

       "cipher  suite  id unavailable" - The cipher suite id you wish to authenticate with is not
       available on the remote BMC. Please try again with an alternate cipher suite  id.  It  may
       also be possible the available cipher suite ids are not correctly configured on the remote
       BMC.

       "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine. Please try  to
       use IPMI 1.5 instead.

       "connection timeout" - Initial IPMI communication failed. A number of potential errors are
       possible, including an invalid hostname specified, an IPMI IP address cannot be  resolved,
       IPMI  is  not  enabled  on  the  remote server, the network connection is bad, etc. Please
       verify configuration and connectivity.

       "session timeout" - The IPMI session has timed  out.  Please  reconnect.   If  this  error
       occurs  often,  you  may wish to increase the retransmission timeout. Some remote BMCs are
       considerably slower than others.

       "device not found" - The specified device could not be found. Please  check  configuration
       or inputs and try again.

       "driver  timeout"  -  Communication  with  the  driver or device has timed out. Please try
       again.

       "message timeout" - Communication with the driver or device  has  timed  out.  Please  try
       again.

       "BMC  busy" - The BMC is currently busy. It may be processing information or have too many
       simultaneous sessions to manage. Please wait and try again.

       "could not find inband device" - An inband  device  could  not  be  found.   Please  check
       configuration or specify specific device or driver on the command line.

       "driver  timeout"  -  The  inband  driver  has timed out communicating to the local BMC or
       service processor. The BMC or service processor may be busy or (worst case) possibly  non-
       functioning.

WORKAROUNDS

       With  so  many  different vendors implementing their own IPMI solutions, different vendors
       may implement their IPMI protocols  incorrectly.  The  following  describes  a  number  of
       workarounds  currently  available  to  handle discovered compliance issues. When possible,
       workarounds have been implemented so they will be transparent to the user.  However,  some
       will require the user to specify a workaround be used via the -W option.

       The hardware listed below may only indicate the hardware that a problem was discovered on.
       Newer versions of hardware may fix the problems indicated  below.  Similar  machines  from
       vendors  may  or  may  not  exhibit the same problems. Different vendors may license their
       firmware from the same IPMI firmware developer, so it may be worthwhile to try workarounds
       listed below even if your motherboard is not listed.

       If you believe your hardware has an additional compliance issue that needs a workaround to
       be implemented, please contact the FreeIPMI  maintainers  on  <freeipmi-users@gnu.org>  or
       <freeipmi-devel@gnu.org>.

       assumeio  - This workaround flag will assume inband interfaces communicate with system I/O
       rather than being memory-mapped. This will work around systems that  report  invalid  base
       addresses.  Those  hitting  this  issue  may see "device not supported" or "could not find
       inband device" errors.  Issue observed on HP ProLiant DL145 G1.

       spinpoll - This workaround flag will inform some inband  drivers  (most  notably  the  KCS
       driver)  to  spin  while  polling  rather  than  putting  the  process  to sleep. This may
       significantly improve the wall clock running time of tools  because  an  operating  system
       scheduler's granularity may be much larger than the time it takes to perform a single IPMI
       message transaction. However, by spinning, your system may be performing less useful  work
       by not contexting out the tool for a more useful task.

       authcap  -  This  workaround  flag  will  skip  early  checks  for  username capabilities,
       authentication capabilities, and K_g support and allow IPMI authentication to succeed.  It
       works  around multiple issues in which the remote system does not properly report username
       capabilities, authentication capabilities, or K_g status. Those hitting this issue may see
       "username  invalid",  "authentication  type unavailable for attempted privilege level", or
       "k_g  invalid"  errors.   Issue   observed   on   Asus   P5M2/P5MT-R/RS162-E4/RX4,   Intel
       SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

       nochecksumcheck  -  This  workaround  flag  will  tell FreeIPMI to not check the checksums
       returned from IPMI  command  responses.  It  works  around  systems  that  return  invalid
       checksums  due  to  implementation  errors,  but  the packet is otherwise valid. Users are
       cautioned on the use of this option, as it removes validation of  packet  integrity  in  a
       number  of circumstances. However, it is unlikely to be an issue in most situations. Those
       hitting  this  issue  may  see  "connection  timeout",  "session  timeout",  or  "password
       verification  timeout"  errors.  On IPMI 1.5 connections, the "noauthcodecheck" workaround
       may also needed too. Issue observed  on  Supermicro  X9SCM-iiF,  Supermicro  X9DRi-F,  and
       Supermicro X9DRFR.

       idzero  -  This workaround flag will allow empty session IDs to be accepted by the client.
       It works around IPMI sessions that report empty session IDs to the client.  Those  hitting
       this issue may see "session timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       unexpectedauth  -  This  workaround  flag  will  allow unexpected non-null authcodes to be
       checked as though they were expected. It works around an issue when packets  contain  non-
       null   authentication   data  when  they  should  be  null  due  to  disabled  per-message
       authentication. Those hitting this issue may see "session timeout" errors. Issue  observed
       on Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This  workaround  flag will force per-message authentication to be used no
       matter what is advertised by the remote system. It works around an issue when  per-message
       authentication is advertised as disabled on the remote system, but it is actually required
       for the protocol. Those hitting this  issue  may  see  "session  timeout"  errors.   Issue
       observed on IBM eServer 325.

       endianseq  -  This workaround flag will flip the endian of the session sequence numbers to
       allow the session to continue properly. It works around IPMI 1.5 session sequence  numbers
       that  are  the  wrong  endian.  Those hitting this issue may see "session timeout" errors.
       Issue observed on some Sun ILOM 1.0/2.0 (depends on service processor endian).

       noauthcodecheck - This workaround flag will tell FreeIPMI to not check the  authentication
       codes  returned  from  IPMI  1.5  command  responses.  It works around systems that return
       invalid authentication codes due to hashing or implementation errors. Users are  cautioned
       on the use of this option, as it removes an authentication check verifying the validity of
       a packet. However, in most organizations, this is unlikely to be a security  issue.  Those
       hitting  this  issue  may  see  "connection  timeout",  "session  timeout",  or  "password
       verification timeout" errors.  Issue  observed  on  Xyratex  FB-H8-SRAY,  Intel  Windmill,
       Quanta Winterfell, and Wiwynn Windmill.

       intel20  -  This  workaround  flag  will work around several Intel IPMI 2.0 authentication
       issues. The issues covered include padding of usernames, and password  truncation  if  the
       authentication  algorithm  is  HMAC-MD5-128.  Those  hitting  this issue may see "username
       invalid", "password invalid", or "k_g invalid" errors. Issue observed on  Intel  SE7520AF2
       with Intel Server Management Module (Professional Edition).

       supermicro20  -  This  workaround  flag  will  work  around  several  Supermicro  IPMI 2.0
       authentication issues on motherboards w/  Peppercon  IPMI  firmware.  The  issues  covered
       include  handling  invalid  length  authentication codes. Those hitting this issue may see
       "password invalid" errors.  Issue observed on Supermicro H8QME with SIMSO  daughter  card.
       Confirmed fixed on newerver firmware.

       sun20  -  This  workaround  flag will work work around several Sun IPMI 2.0 authentication
       issues. The issues covered include invalid lengthed hash keys, improperly hashed keys, and
       invalid  cipher suite records. Those hitting this issue may see "password invalid" or "bmc
       error" errors.  Issue observed on Sun Fire  4100/4200/4500  with  ILOM.   This  workaround
       automatically includes the "opensesspriv" workaround.

       opensesspriv  -  This  workaround  flag will slightly alter FreeIPMI's IPMI 2.0 connection
       protocol to workaround an invalid  hashing  algorithm  used  by  the  remote  system.  The
       privilege  level  sent during the Open Session stage of an IPMI 2.0 connection is used for
       hashing keys instead of the privilege level sent during the RAKP1 connection stage.  Those
       hitting  this  issue  may  see  "password invalid", "k_g invalid", or "bad rmcpplus status
       code" errors.  Issue observed on Sun Fire 4100/4200/4500  with  ILOM,  Inventec  5441/Dell
       Xanadu  II,  Supermicro  X8DTH, Supermicro X8DTG, Intel S5500WBV/Penguin Relion 700, Intel
       S2600JF/Appro 512X, and Quanta QSSC-S4R/Appro GB812X-CN. This workaround is  automatically
       triggered with the "sun20" workaround.

       integritycheckvalue  -  This  workaround  flag will work around an invalid integrity check
       value during an IPMI 2.0 session establishment when using Cipher Suite ID 0. The integrity
       check  value  should be 0 length, however the remote motherboard responds with a non-empty
       field. Those hitting this issue may see "k_g invalid" errors. Issue observed on Supermicro
       X8DTG,  Supermicro  X8DTU,  and Intel S5500WBV/Penguin Relion 700, and Intel S2600JF/Appro
       512X.

       guidformat - A number of vendors send  the  bytes  of  the  GUID  (such  as  the  GUID  in
       --get-device-guid  or  --get-system-guid)  in  an alternate format that aligns incorrectly
       with IPMI, but correctly with other standards. This workaround flag will instruct bmc-info
       to read the GUID and output the GUID based on this common alternate format.

       No  IPMI  1.5  Support  -  Some  motherboards that support IPMI 2.0 have been found to not
       support IPMI 1.5. Those hitting this issue may see "ipmi 2.0 unavailable"  or  "connection
       timeout"  errors. This issue can be worked around by using IPMI 2.0 instead of IPMI 1.5 by
       specifying --driver-type=LAN_2_0. Issue observed on HP Proliant DL 145.

OEM INTERPRETATION

       The following motherboards are confirmed to have atleast some support by the  --interpret-
       oem-data  option.  While  highly  probable  the OEM data interpretations would work across
       other motherboards by the  same  manufacturer,  there  are  no  guarantees.  Some  of  the
       motherboards below may be rebranded by vendors/distributors.

       Dell Poweredge R610, Dell Poweredge R710, Intel SR870BN4/Tiger4

EXAMPLES

       # bmc-info

       Get BMC information of the local machine.

       # bmc-info -h ahost -u myusername -p mypassword

       Get BMC information of a remote machine using IPMI over LAN.

       # bmc-info -h mycluster[0-127] -u myusername -p mypassword

       Get BMC information across a cluster using IPMI over LAN.

DIAGNOSTICS

       Upon successful execution, exit status is 0. On error, exit status is 1.

       If multiple hosts are specified for communication, the exit status is 0 if and only if all
       targets successfully execute. Otherwise the exit status is 1.

KNOWN ISSUES

       On older operating systems, if you input your username, password,  and  other  potentially
       security  relevant  information on the command line, this information may be discovered by
       other users when using tools like the ps(1) command or looking in the /proc  file  system.
       It  is  generally more secure to input password information with options like the -P or -K
       options. Configuring security relevant information  in  the  FreeIPMI  configuration  file
       would also be an appropriate way to hide this information.

       In  order  to  prevent  brute  force attacks, some BMCs will temporarily "lock up" after a
       number of remote authentication errors. You may need to  wait  awhile  in  order  to  this
       temporary "lock up" to pass before you may authenticate again.

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright © 2003-2014 FreeIPMI Core Team.

       This program is free software; you can redistribute it and/or modify it under the terms of
       the GNU General Public License as  published  by  the  Free  Software  Foundation;  either
       version 3 of the License, or (at your option) any later version.

SEE ALSO

       freeipmi.conf(5), freeipmi(7), ipmi-config(8)

       http://www.gnu.org/software/freeipmi/