Provided by: freeipmi-ipmiseld_1.4.11-1.1ubuntu4.1_amd64 bug

NAME

       ipmiseld - IPMI SEL logging daemon

SYNOPSIS

       ipmiseld [OPTION...]

DESCRIPTION

       The  ipmiseld  daemon  polls  the  system event log (SEL) of specified hosts and stores the logs into the
       local syslog. By default, the daemon can also make best efforts to manage  the  remote  SEL's  buffer  to
       ensure  events  are  never lost. Recent logging data will be cached to disk to ensure that SEL events are
       not missed in the event the client or server is rebooted.

       Many of the options for this daemon are very similar to the ipmi-sel(8) tool. It can be configured to log
       the  local  host,  a  remote  host, or a range of hosts to the local syslog. It can be configured via the
       command line arguments listed below or via the /etc/freeipmi//ipmiseld.conf configuration file.

       Listed below are general IPMI options, tool specific options, trouble  shooting  information,  workaround
       information, examples, and known issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS

       The  following  options are general options for configuring IPMI communication and executing general tool
       commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
              Specify the driver type to use instead of  doing  an  auto  selection.   The  currently  available
              outofband  drivers  are  LAN  and  LAN_2_0,  which perform IPMI 1.5 and IPMI 2.0 respectively. The
              currently available inband drivers are KCS, SSIF, OPENIPMI, SUNBMC, and INTELDCMI.

       --disable-auto-probe
              Do not probe in-band IPMI devices for default settings.

       --driver-address=DRIVER-ADDRESS
              Specify the in-band driver address to be used instead of the probed value.  DRIVER-ADDRESS  should
              be prefixed with "0x" for a hex value and '0' for an octal value.

       --driver-device=DEVICE
              Specify the in-band driver device path to be used instead of the probed path.

       --register-spacing=REGISTER-SPACING
              Specify  the  in-band  driver  register  spacing instead of the probed value. Argument is in bytes
              (i.e. 32bit register spacing = 4)

       --target-channel-number=CHANNEL-NUMBER
              Specify the in-band driver target channel number to send IPMI requests to.

       --target-slave-address=SLAVE-ADDRESS
              Specify the in-band driver target slave number to send IPMI requests to.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated  by  comma  or
              may  be  specified  in  a  range  format;  see  HOSTRANGED  SUPPORT below. An optional port can be
              specified with each host, which may be useful in port forwarding or similar situations.

       -u USERNAME, --username=USERNAME
              Specify the username to use when authenticating with the remote host.  If not  specified,  a  null
              (i.e. anonymous) username is assumed. The user must have atleast USER privileges in order for this
              tool to operate fully.

       -p PASSWORD, --password=PASSWORD
              Specify the password to use when authenticationg with the remote host.  If not specified,  a  null
              password is assumed. Maximum password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password to avoid possibility of listing it in process lists.

       -k K_G, --k-g=K_G
              Specify  the  K_g  BMC  key  to  use when authenticating with the remote host for IPMI 2.0. If not
              specified, a null key is assumed. To input the key in hexadecimal form,  prefix  the  string  with
              '0x'. E.g., the key 'abc' can be entered with the either the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of listing it in process lists.

       --session-timeout=MILLISECONDS
              Specify  the  session  timeout in milliseconds. Defaults to 20000 milliseconds (20 seconds) if not
              specified.

       --retransmission-timeout=MILLISECONDS
              Specify the packet retransmission timeout  in  milliseconds.  Defaults  to  1000  milliseconds  (1
              second) if not specified. The retransmission timeout cannot be larger than the session timeout.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
              Specify  the IPMI 1.5 authentication type to use. The currently available authentication types are
              NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5. Defaults to MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI  2.0  cipher  suite  ID  to  use.  The  Cipher  Suite  ID  identifies  a  set  of
              authentication,  integrity,  and confidentiality algorithms to use for IPMI 2.0 communication. The
              authentication algorithm identifies  the  algorithm  to  use  for  session  setup,  the  integrity
              algorithm  identifies  the algorithm to use for session packet signatures, and the confidentiality
              algorithm identifies the algorithm to use for payload encryption. Defaults to cipher suite ID 3 if
              not specified. The following cipher suite ids are currently supported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None; Confidentiality Algorithm = None

              1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Confidentiality Algorithm =
              None

              2 - Authentication Algorithm = HMAC-SHA1;  Integrity  Algorithm  =  HMAC-SHA1-96;  Confidentiality
              Algorithm = None

              3  -  Authentication  Algorithm  =  HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality
              Algorithm = AES-CBC-128

              6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confidentiality  Algorithm  =
              None

              7  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity Algorithm = HMAC-MD5-128; Confidentiality
              Algorithm = None

              8 - Authentication Algorithm =  HMAC-MD5;  Integrity  Algorithm  =  HMAC-MD5-128;  Confidentiality
              Algorithm = AES-CBC-128

              11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = None

              12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = AES-CBC-128

              15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm = None; Confidentiality Algorithm
              = None

              16  -  Authentication  Algorithm   =   HMAC-SHA256;   Integrity   Algorithm   =   HMAC_SHA256_128;
              Confidentiality Algorithm = None

              17   -   Authentication   Algorithm   =   HMAC-SHA256;   Integrity  Algorithm  =  HMAC_SHA256_128;
              Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify the privilege level to be  used.  The  currently  available  privilege  levels  are  USER,
              OPERATOR, and ADMIN. Defaults to OPERATOR if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify  workarounds  to vendor compliance issues. Multiple workarounds can be specified separated
              by commas. A special command line flag of "none", will indicate no workarounds (may be useful  for
              overriding configured defaults). See WORKAROUNDS below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMISELD OPTIONS

       The following options are specific to Ipmiseld.

       -v     Log verbose information. This option will log additional information.  Most notably it will output
              additional hex codes to given information on ambiguous SEL entries or SEL records. For example, it
              will  output  Generator ID hex codes for sensors without names. Additional non-critical SEL errors
              or issues will also be logged. Somewhat common errors, such as timeouts or invalid hostnames, will
              output with increased verbosity.

       -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
              Specify  sensor  types  of  SEL  events to log. By default, all sensor types are logged. A special
              command line type of "all", will indicate all types should be shown (may be useful for  overriding
              configured  defaults).  Multiple  types  can  be separated by commas or spaces.  Users may specify
              sensor types by string (see --list-sensor-types in ipmi-sel(8)) or by number (decimal or hex).

       -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
              Specify sensor types of SEL events to not log. By default, no sensor types are filtered. A special
              command  line  type  of  "none",  will  indicate  no  types  should be excluded (may be useful for
              overriding configured defaults). Multiple types can be separated by commas or  spaces.  Users  may
              specify  sensor  types by string (see --list-sensor-types in ipmi-sel(8)) or by number (decimal or
              hex).

       --system-event-only
              Log only system event records (i.e. don't log OEM records).

       --oem-event-only
              Log only OEM event records (i.e. don't log system event records).

       --event-state-config-file=FILE
              Specify an alternate event state configuration file.

       --interpret-oem-data
              Attempt to interpret OEM data, such as event data, sensor readings, or general extra info, etc. If
              an  OEM  interpretation is not available, the default output will be generated. Correctness of OEM
              interpretations cannot be guaranteed due to potential changes OEM vendors may  make  in  products,
              firmware, etc. See OEM INTERPRETATION below for confirmed supported motherboard interpretations.

       --entity-sensor-names
              Output  sensor  names prefixed with their entity id and instance number when appropriate. This may
              be necessary on some motherboards to help identify what sensors are referencing.  For  example,  a
              motherboard  may  have  multiple  sensors named 'TEMP'. The entity id and instance number may help
              clarify which sensor refers to "Processor 1" vs. "Processor 2".

       --non-abbreviated-units
              Output non-abbreviated units (e.g. 'Amps' instead of 'A'). May  aid  in  disambiguation  of  units
              (e.g. 'C' for Celsius or Coulombs).

       --event-state-filter=FILTERSTRING
              Specify  event  states  to  be  filtered out and not logged. Possible inputs are NOMINAL, WARNING,
              CRITICAL, and NA. Multiple states can be listed separted by comma.  The  special  case  string  of
              "none"  will  indicate no event states should be excluded (may be useful for overriding configured
              defaults).

       --warning-threshold=PERCENTINT
              Specify SEL fullness warning threshold as an  integer  percentage.  When  the  SEL  is  past  this
              percentage full, a warning will be output indicating that SEL is nearly full. Specify 0 to disable
              warning logs. Defaults to 80.

       --clear-threshold=PERCENTINT
              Specify SEL fullness clear threshold  as  an  integer  percentage.  When  the  SEL  is  past  this
              percentage  full,  ipmiseld will attempt to clear the SEL. Specify 0 to disable clearing. When the
              SEL is full, it will be the responsibility of the user to clear the SEL manually  if  clearing  is
              disabled. Defaults to 0. If specified to a non-zero value, be careful that the clearing of the SEL
              could affect other applications that monitor the SEL, such as  monitoring  applications  that  use
              ipmi-sel(8) or libipmimonitoring(3).

       --system-event-format=FORMATSTRING
              Specify  the  format  of  the  log output when a SEL system event is encountered. Defaults to "SEL
              System Event: %d, %t, %s, %I, %E" if logging locally, "SEL System Event(%h): %d, %t, %s,  %I,  %E"
              if logging outofband or with hostranges. See SEL LOG FORMAT STRING below for formatting details.

       --oem-timestamped-event-format=FORMATSTRING
              Specify  the format of the log output when a SEL OEM timestamped event is encountered. Defaults to
              "SEL OEM Event: %d, %t, %I, %o" if logging locally, "SEL OEM Event(%h): %d, %t, %I, %o" if logging
              outofband or with hostranges.. See SEL LOG FORMAT STRING below for formatting details.

       --oem-non-timestamped-event-format=FORMATSTRING
              Specify the format of the log output when a SEL OEM non-timestamped event is encountered. Defaults
              to "SEL OEM Event: %I, %o" if logging locally, "SEL OEM Event(%h): %I, %o" if logging outofband or
              with hostranges.. See SEL LOG FORMAT STRING below for formatting details.

       --poll-interval=SECONDS
              Specify  the  poll  interval  to  check  the  SEL  for new events. Defaults to 300 seconds (i.e. 5
              minutes).

       --log-facility=STRING
              Specify the log facility to use. Defaults to LOG_DAEMON. Legal inputs  are  LOG_DAEMON,  LOG_USER,
              LOG_LOCAL0, LOG_LOCAL1, LOG_LOCAL2, LOG_LOCAL3, LOG_LOCAL4, LOG_LOCAL5, LOG_LOCAL6, LOG_LOCAL7.

       --log-priority=STRING
              Specify  the  log  priority  to  use.  Defaults to LOG_ERR. Legal inputs are LOG_EMERG, LOG_ALERT,
              LOG_CRIT, LOG_ERR, LOG_WARNING, LOG_NOTICE, LOG_INFO, LOG_DEBUG.

       --cache-directory=DIRECTORY
              Specify an alternate cache directory location for ipmiseld to use. The  cache  directory  will  be
              used  to  cache a wide variety of data, including the SDR and recent logging information to ensure
              log entries are not missed on reboots and other system failures.

       --ignore-sdr
              Ignore SDR related processing. May lead to incomplete or less  useful  information  being  output,
              however  it  will  allow  functionality for systems without SDRs or when the correct SDR cannot be
              loaded.

       --re-download-sdr
              Re-download the SDR on start even if it is not out of date. This may help work around systems that
              do not properly timestamp SDR modification times.

       --clear-sel
              On  startup, clear any SEL being monitored. May be useful the first time running ipmiseld to avoid
              warning messages or SEL clears until a long time in the future.

       --threadpool-count=NUM
              Specify the number of threads for parallel SEL  polling.  This  option  is  very  similar  to  the
              --fanout  option in ipmi-sel(8) but the threads are created only once on initialization for faster
              processing. Defaults to 8, however the threadpool count will always be decreased if the number  of
              nodes specified is less than the number of threads.

       --test-run
              Do  not  daemonize,  output  the current SEL of configured hosts as a test of current settings and
              configuration.

       --foreground
              Run daemon in the foreground.

SEL LOG FORMAT STRING

       The   output   format   of   log   messages   can   be   adjusted    via    the    --system-event-format,
       --oem-timestamped-event-format   and   --oem-non-timestamped-event-format   options.   Options   such  as
       --interpret-oem-data, --entity-sensor-names, and --non-abbreviated-units can further  adjust  the  output
       format.  The  following  conversion  directives will allow the user to output specifics of each SEL event
       that occurs.

       For System, OEM timestamped, and OEM non-timestamped events

       %h - target host, useful if logging from multiple hosts

       %i - record ID in decimal

       %I - event state interpretation (NOMINAL, WARNING, or CRITICAL)

       For System and OEM timestamped events

       %t - time in format H:M:S using 24 hour clock

       %d - date in format D-M-YEAR

       For System events

       %T - sensor type

       %s - sensor name

       %e - event data 1 string

       %f - event data 2 string [2]

       %h - event data 3 string

       %c - combined event data 2 and event data 3 string

       %p - event data 2 previous state string

       %S - event data 2 severity string

       %E - combined event data 1, 2, and 3 string

       %k - event direction

       For OEM timestamped events

       %m - manufacturer id

       For OEM timestamped and OEM non-timestamped events

       %o - oem data in hex

       %O - OEM supplied string describing the event (depends on manufacturer)

HOSTRANGED SUPPORT

       Multiple hosts can be input either as an explicit comma separated lists of hosts or a range of  hostnames
       in  the  general  form:  prefix[n-m,l-k,...],  where  n  < m and l < k, etc. The later form should not be
       confused with regular expression character classes (also denoted by []). For example,  foo[19]  does  not
       represent foo1 or foo9, but rather represents a degenerate range: foo19.

       This  range  syntax  is  meant  only  as  a convenience on clusters with a prefixNN naming convention and
       specification of ranges should not be considered necessary -- the list foo1,foo9 could  be  specified  as
       such, or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As  a  reminder  to  the  reader,  some  shells  will  interpret brackets ([ and ]) for pattern matching.
       Depending on your shell, it may be necessary to enclose ranged lists within quotes.

       In-band IPMI Communication will be used when the host "localhost" is specified. This allows the  user  to
       add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due to configuration problems.

       IPMI over LAN problems involve a misconfiguration of the remote machine's BMC.  Double check to make sure
       the following are configured properly in the remote machine's BMC: IP address, MAC address, subnet  mask,
       username,  user  enablement,  user  privilege,  password,  LAN  privilege,  LAN  enablement,  and allowed
       authentication type(s). For IPMI 2.0 connections, double check to make sure the cipher suite privilege(s)
       and  K_g  key  are  configured properly. The ipmi-config(8) tool can be used to check and/or change these
       configuration settings.

       Inband IPMI problems are typically caused by improperly configured drivers or non-standard BMCs.

       In addition to the troubleshooting tips below, please see WORKAROUNDS below to  also  if  there  are  any
       vendor specific bugs that have been discovered and worked around.

       Listed below are many of the common issues for error messages.  For additional support, please e-mail the
       <freeipmi-users@gnu.org> mailing list.

       "username invalid" - The username entered (or a NULL username if none was entered) is  not  available  on
       the remote machine. It may also be possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password if none was entered) is not correct. It may
       also be possible the password for the user is not correctly configured on the remote BMC.

       "password verification timeout" - Password verification  has  timed  out.   A  "password  invalid"  error
       (described  above)  or  a generic "session timeout" (described below) occurred.  During this point in the
       protocol it cannot be differentiated which occurred.

       "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered) is not correct. It  may  also
       be possible the K_g key is not correctly configured on the remote BMC.

       "privilege  level  insufficient"  -  An  IPMI  command  requires  a  higher  user  privilege than the one
       authenticated with. Please try to authenticate with a higher privilege. This may  require  authenticating
       to a different user which has a higher maximum privilege.

       "privilege  level  cannot  be  obtained  for  this  user"  -  The  privilege  level you are attempting to
       authenticate with is higher than the maximum allowed for  this  user.  Please  try  again  with  a  lower
       privilege.  It  may  also  be  possible  the maximum privilege level allowed for a user is not configured
       properly on the remote BMC.

       "authentication type unavailable for attempted privilege level" - The authentication  type  you  wish  to
       authenticate  with  is  not  available  for  this  privilege  level.  Please  try again with an alternate
       authentication type or alternate privilege level. It may also be possible  the  available  authentication
       types you can authenticate with are not correctly configured on the remote BMC.

       "cipher suite id unavailable" - The cipher suite id you wish to authenticate with is not available on the
       remote BMC. Please try again with an alternate cipher suite id. It may also  be  possible  the  available
       cipher suite ids are not correctly configured on the remote BMC.

       "ipmi  2.0  unavailable"  - IPMI 2.0 was not discovered on the remote machine. Please try to use IPMI 1.5
       instead.

       "connection timeout" - Initial IPMI communication failed. A number  of  potential  errors  are  possible,
       including  an  invalid  hostname specified, an IPMI IP address cannot be resolved, IPMI is not enabled on
       the remote server, the network connection is bad, etc. Please verify configuration and connectivity.

       "session timeout" - The IPMI session has timed out. Please reconnect.  If this error  occurs  often,  you
       may wish to increase the retransmission timeout. Some remote BMCs are considerably slower than others.

       "device  not  found"  - The specified device could not be found. Please check configuration or inputs and
       try again.

       "driver timeout" - Communication with the driver or device has timed out. Please try again.

       "message timeout" - Communication with the driver or device has timed out. Please try again.

       "BMC busy" - The BMC is currently busy. It may be processing information or have  too  many  simultaneous
       sessions to manage. Please wait and try again.

       "could  not  find  inband  device"  - An inband device could not be found.  Please check configuration or
       specify specific device or driver on the command line.

       "driver timeout" - The inband driver has timed out communicating to the local BMC or  service  processor.
       The BMC or service processor may be busy or (worst case) possibly non-functioning.

       "internal  IPMI  error" - An IPMI error has occurred that FreeIPMI does not know how to handle. Please e-
       mail <freeipmi-users@gnu.org> to report the issue.

IPMISELD TROUBLESHOOTING

       Some timestamps in the SEL may report a date of 1-Jan-1970, the epoch for SEL timestamps. This  timestamp
       is  not  necessarily incorrect. It usually indicates a hardware event that occurred before a timestamp in
       firmware has been initialized. For example, certain hardware components will have their  internal  clocks
       reset during a power cycle.

       However,  if the internal clock of the SEL appears to be regularly incorrect, you may need to set the SEL
       time. This can be done using bmc-device(8).

       The following are common SEL related messages.

       "sel config file parse error" - A parse error was found in the  sel  event  interpretation  configuration
       file. Please see freeipmi_interpret_sel.conf(5).

WORKAROUNDS

       With  so  many  different  vendors implementing their own IPMI solutions, different vendors may implement
       their IPMI protocols incorrectly. The following describes a number of workarounds currently available  to
       handle  discovered  compliance  issues.  When possible, workarounds have been implemented so they will be
       transparent to the user. However, some will require the user to specify a workaround be used via  the  -W
       option.

       The hardware listed below may only indicate the hardware that a problem was discovered on. Newer versions
       of hardware may fix the problems indicated below. Similar machines from vendors may or  may  not  exhibit
       the same problems. Different vendors may license their firmware from the same IPMI firmware developer, so
       it may be worthwhile to try workarounds listed below even if your motherboard is not listed.

       If you believe your  hardware  has  an  additional  compliance  issue  that  needs  a  workaround  to  be
       implemented,    please    contact    the    FreeIPMI    maintainers    on   <freeipmi-users@gnu.org>   or
       <freeipmi-devel@gnu.org>.

       assumeio - This workaround flag will assume inband interfaces communicate with  system  I/O  rather  than
       being memory-mapped. This will work around systems that report invalid base addresses. Those hitting this
       issue may see "device not supported" or "could not find inband device"  errors.   Issue  observed  on  HP
       ProLiant DL145 G1.

       spinpoll  -  This  workaround  flag will inform some inband drivers (most notably the KCS driver) to spin
       while polling rather than putting the process to sleep. This may significantly  improve  the  wall  clock
       running  time  of  tools  because an operating system scheduler's granularity may be much larger than the
       time it takes to perform a single IPMI message transaction. However, by  spinning,  your  system  may  be
       performing less useful work by not contexting out the tool for a more useful task.

       authcap  -  This  workaround  flag  will  skip  early  checks  for  username capabilities, authentication
       capabilities, and K_g support and allow IPMI authentication to succeed. It works around  multiple  issues
       in  which  the remote system does not properly report username capabilities, authentication capabilities,
       or K_g status. Those hitting this issue may see "username invalid", "authentication type unavailable  for
       attempted  privilege  level",  or "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4,
       Intel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

       nochecksumcheck - This workaround flag will tell FreeIPMI to not check the checksums returned  from  IPMI
       command  responses.  It  works around systems that return invalid checksums due to implementation errors,
       but the packet is otherwise valid. Users are  cautioned  on  the  use  of  this  option,  as  it  removes
       validation  of  packet  integrity in a number of circumstances. However, it is unlikely to be an issue in
       most situations. Those hitting this issue may see "connection timeout", "session timeout",  or  "password
       verification  timeout"  errors. On IPMI 1.5 connections, the "noauthcodecheck" workaround may also needed
       too. Issue observed on Supermicro X9SCM-iiF, Supermicro X9DRi-F, and Supermicro X9DRFR.

       idzero - This workaround flag will allow empty session IDs to be accepted by the client. It works  around
       IPMI  sessions  that  report  empty  session IDs to the client. Those hitting this issue may see "session
       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       unexpectedauth - This workaround flag will allow unexpected non-null authcodes to be  checked  as  though
       they  were expected. It works around an issue when packets contain non-null authentication data when they
       should be null due to disabled per-message authentication. Those hitting  this  issue  may  see  "session
       timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This  workaround  flag will force per-message authentication to be used no matter what is
       advertised by the remote system. It works around an issue when per-message authentication  is  advertised
       as  disabled on the remote system, but it is actually required for the protocol. Those hitting this issue
       may see "session timeout" errors.  Issue observed on IBM eServer 325.

       endianseq - This workaround flag will flip the endian of  the  session  sequence  numbers  to  allow  the
       session  to  continue  properly.  It  works  around  IPMI 1.5 session sequence numbers that are the wrong
       endian.  Those hitting this issue may see "session timeout" errors.  Issue  observed  on  some  Sun  ILOM
       1.0/2.0 (depends on service processor endian).

       noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the authentication codes returned
       from IPMI 1.5 command responses. It works around systems that return invalid authentication codes due  to
       hashing  or  implementation  errors.  Users  are  cautioned  on  the use of this option, as it removes an
       authentication check verifying the validity of a packet. However, in most organizations, this is unlikely
       to  be  a  security  issue.  Those hitting this issue may see "connection timeout", "session timeout", or
       "password verification timeout" errors.  Issue observed on Xyratex  FB-H8-SRAY,  Intel  Windmill,  Quanta
       Winterfell, and Wiwynn Windmill.

       intel20  - This workaround flag will work around several Intel IPMI 2.0 authentication issues. The issues
       covered include padding of usernames, and password truncation if the authentication  algorithm  is  HMAC-
       MD5-128.  Those  hitting  this  issue  may  see  "username invalid", "password invalid", or "k_g invalid"
       errors. Issue observed on Intel SE7520AF2 with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro IPMI 2.0 authentication issues on
       motherboards   w/   Peppercon   IPMI  firmware.  The  issues  covered  include  handling  invalid  length
       authentication codes. Those hitting this issue may see "password  invalid"  errors.   Issue  observed  on
       Supermicro H8QME with SIMSO daughter card. Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0 authentication issues. The issues
       covered include invalid lengthed hash keys, improperly hashed keys, and  invalid  cipher  suite  records.
       Those  hitting  this  issue may see "password invalid" or "bmc error" errors.  Issue observed on Sun Fire
       4100/4200/4500 with ILOM.  This workaround automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly  alter  FreeIPMI's  IPMI  2.0  connection  protocol  to
       workaround  an  invalid  hashing algorithm used by the remote system. The privilege level sent during the
       Open Session stage of an IPMI 2.0 connection is used for hashing keys instead of the privilege level sent
       during the RAKP1 connection stage. Those hitting this issue may see "password invalid", "k_g invalid", or
       "bad rmcpplus status code" errors.  Issue  observed  on  Sun  Fire  4100/4200/4500  with  ILOM,  Inventec
       5441/Dell  Xanadu  II,  Supermicro  X8DTH,  Supermicro  X8DTG,  Intel  S5500WBV/Penguin Relion 700, Intel
       S2600JF/Appro 512X, and Quanta QSSC-S4R/Appro GB812X-CN. This workaround is automatically triggered  with
       the "sun20" workaround.

       integritycheckvalue  -  This  workaround flag will work around an invalid integrity check value during an
       IPMI 2.0 session establishment when using Cipher Suite ID 0.  The  integrity  check  value  should  be  0
       length,  however the remote motherboard responds with a non-empty field. Those hitting this issue may see
       "k_g invalid" errors. Issue observed on Supermicro X8DTG, Supermicro X8DTU,  and  Intel  S5500WBV/Penguin
       Relion 700, and Intel S2600JF/Appro 512X.

       assumesystemevent - This workaround option will assume invalid SEL record types are system event records.
       Records may be formatted correctly but report invalid record types. Those  hitting  this  issue  may  see
       "Unknown  SEL  Record Type" errors. Output may be unknown, pray for the best. This option is confirmed to
       work around compliances issues on HP DL 380 G5 motherboards.

       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been found to not  support  IPMI  1.5.
       Those hitting this issue may see "ipmi 2.0 unavailable" or "connection timeout" errors. This issue can be
       worked around by using IPMI 2.0 instead of IPMI 1.5 by specifying --driver-type=LAN_2_0.  Issue  observed
       on HP Proliant DL 145.

OEM INTERPRETATION

       The following motherboards are confirmed to have atleast some support by the --interpret-oem-data option.
       While highly probable the OEM data interpretations would work  across  other  motherboards  by  the  same
       manufacturer,   there   are   no  guarantees.  Some  of  the  motherboards  below  may  be  rebranded  by
       vendors/distributors.

       Dell Poweredge 2900, Dell Poweredge 2950, Dell Poweredge R610, Dell Poweredge R710, Fujitsu iRMC  S1  and
       iRMC  S2  systems,  Intel S5500WB/Penguin Computing Relion 700, Intel S2600JF/Appro 512X, Intel S5000PAL,
       Inventec 5441/Dell Xanadu II, Inventec 5442/Dell Xanadu  III,  Quanta  S99Q/Dell  FS12-TY,  Quanta  QSSC-
       S4R/Appro  GB812X-CN, Sun X4140 Supermicro X7DBR-3, Supermicro X7DB8, Supermicro X8DTN, Supermicro X7SBI-
       LN4, Supermicro X8DTH, Supermicro X8DTG, Supermicro X8DTU, Supermicro  X8DT3-LN4F,  Supermicro  X8DTU-6+,
       Supermicro X8DTL, Supermicro X8DTL-3F, Supermicro X8SIL-F, Supermicro X9SCL, Supermicro X9SCM, Supermicro
       X8DTN+-F, Supermicro X8SIE, Supermicro X9SCA-F-O,  Supermicro  H8DGU-F,  Supermicro  X9DRi-F,  Supermicro
       X9DRI-LN4F+, Supermicro X9SPU-F-O, Supermicro X9SCM-iiF, Wistron/Dell Poweredge C6220.

KNOWN ISSUES

       On older operating systems, if you input your username, password, and other potentially security relevant
       information on the command line, this information may be discovered by other users when using tools  like
       the  ps(1)  command  or  looking  in the /proc file system. It is generally more secure to input password
       information with options like the -P or -K options. Configuring  security  relevant  information  in  the
       FreeIPMI configuration file would also be an appropriate way to hide this information.

       In  order  to  prevent brute force attacks, some BMCs will temporarily "lock up" after a number of remote
       authentication errors. You may need to wait awhile in order to this temporary "lock up"  to  pass  before
       you may authenticate again.

FILES

       /etc/freeipmi//ipmiseld.conf /var/cache/ipmiseld/

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright (C) 2012-2014 Lawrence Livermore National Security, LLC.

       This  program  is  free  software;  you  can  redistribute it and/or modify it under the terms of the GNU
       General Public License as published by the Free Software Foundation; either version 3 of the License,  or
       (at your option) any later version.

SEE ALSO

       freeipmi(7), ipmi-sel(8), ipmiseld.conf(5), bmc-device(8), ipmi-config(8), freeipmi_interpret_sel.conf(5)

       http://www.gnu.org/software/freeipmi/