Provided by: smp-utils_0.98-2build1_amd64 bug

NAME

       smp_* - invoke a SAS Serial Management Protocol (SMP) function

SYNOPSIS

       smp_*   [--expected=EX]   [--help]   [--hex]  [--interface=PARAMS]  [--raw]  [--sa=SAS_ADDR]  [--verbose]
       [--version] SMP_DEVICE[,N]

DESCRIPTION

       Serial Attached SCSI (SAS) is a transport (also known as a interconnect) used by storage systems.  A  SAS
       system is made up of Host Bus Adapters (HBAs typically containing SCSI initiators), disks (referred to in
       SCSI  as  both  targets  and  logical  units)  and optionally some switching hardware called "expanders".
       Expanders are not SCSI devices so a new protocol was required to control and monitor them. Its full  name
       is the SAS Serial Management Protocol which is abbreviated to SMP.

       smp_utils  is  a package of utilities. Each utility sends an SMP function request to a SMP_DEVICE (an SMP
       target). Some utilities may invoke the same function more than once. If an error  occurs  then  an  error
       message is sent to stderr. If no error occurs, the response is decoded (the default), output in ASCII hex
       (when --hex is given) or output in binary to stdout (when the --raw option is given).

       If SMP_DEVICE[,N] is not given then the value in the environment variable SMP_UTILS_DEVICE is used.

       This package was originally written for Linux and has been ported to FreeBSD and Solaris.

LINUX INTERFACE

       Currently there are multiple interfaces that allow SMP functions to be passed through to an SMP target.

       One  method  is  to have a SMP_DEVICE which is actually the SMP initiator (e.g. '/dev/mptctl,0'). In this
       case the SMP target's SAS address must be supplied with the --sa=SAS_ADDR option.

       Another method is to have a SMP_DEVICE which represents the SMP target.   In  this  case  no  SAS_ADDRESS
       needs to be given (since it is implicit).

       Each  utility  in  smp_utils  attempts  to  work  out  which interface it has been given by examining the
       SMP_DEVICE file. There are three interfaces supported currently:

       aac    This specifies the aacraid  SAS  pass-through  associated  with  Adaptec/PMC  RAID  products.  The
              SMP_DEVICE[,N]  argument takes the form /dev/aac[N[,E_ID]] where "N" is the raid controller number
              (typically 0) and "E_ID" is the expander identifier (typically 0); both default to 0  so  /dev/aac
              is   equivalent   to   /dev/aac0   and   /dev/aac0,0   .   The  "N"  is  the  unique_id  found  in
              /sys/class/scsi_host<HN>/unique_id .  The "HN" is the host number which is  the  first  number  to
              appear  on  each line in the lsscsi utility which by default uses one line to list each accessible
              SCSI device (typically SCSI or ATA disks). The "E_ID" is the  expander  identifier  which  can  be
              found  with the Adaptec/PMC arcconf utility using the form "arcconf expanderlist <ControllerNum>".
              The <ControllerNum>s start at 1 . If an aac RAID controller is present then  the  /dev/acc  device
              node will be created by the first smp utility to use this interface.

       mpt    This  specifies  the  MPT fusion SAS pass-through. The mptsas driver uses the '/dev/mptctl' device
              node (character device major 10, minor 220) while the mpt2sas driver  uses  '/dev/mpt2ctl'  device
              node   (major  10,  minor  221).   For  the  mpt3sas  driver  the  corresponding  device  node  is
              '/dev/mpt3ctl'.  The 'modprobe mptctl' or 'modprobe mpt2ctl' command may be needed. If  there  are
              multiple  mpt  fusion controllers (HBAs) in the computer, then the user will need to specify which
              one to use with the syntax: '/dev/mptctl,<n>' where <n> is the "ioc_num". This number can be found
              with dmesg after the mptsas driver is registered and appears as a suffix to the driver name  (e.g.
              mpt2sas0).  It can also be found in '/sys/class/scsi_host/host<n>/unique_id'.  When this interface
              is used the --sa=SAS_ADDR option must be given to specify the SAS address of the SMP target.

       sgv4 (sg)
              This interface is more generic and supported by several SAS  HBA  drivers  including  mptsas  (and
              mpt2sas). It was introduced in the Linux 2.6.24 kernel. The SMP functions are passed to the kernel
              via the bsg driver using a format known as "SCSI Generic Version 4" which gives this interface its
              name:  "sgv4"  or  just  "sg".  The SAS transport layer within the SCSI sub-system unpacks the SMP
              requests and forwards them to SAS low level drivers that support this interface. The SMP_DEVICE is
              either a member of the '/sys/class/bsg' directory (e.g. /sys/class/bsg/expander-6:0 ) or a  device
              node  made  for  the bsg driver (e.g. /dev/bsg/expander-6:0 ). Such device nodes are dynamic (i.e.
              they don't have fixed major and minor numbers) and  should  correspond  to  the  major  and  minor
              numbers found in the 'sys/class/bsg/<smp_target_device>/dev' file.

FREEBSD INTERFACE

       The  CAM  subsystem  has  been  enhanced  in  FreeBSD  9  to  pass-through  SMP  requests  and return the
       corresponding responses. However CAM does not directly access expander devices because they are not  SCSI
       devices. It makes the assumption that each SAS expander has an integrated SES (enclosure) device and that
       is  addressed.  This  assumption  seems to be true for SAS-2 expanders but not some SAS-1 expanders. Thus
       invocations look like this:

         # smp_discover /dev/ses0

       where /dev/ses0 is a SES device associated with a SAS expander.

SOLARIS INTERFACE

       The USMP pass-through mechanism is used. Invocations look like this:

         # smp_rep_manufacturer /dev/smp/expd0

ENVIRONMENT VARIABLES

       If the device name is not given then the SMP_UTILS_DEVICE environment variable is checked and if  present
       its contents are used as the device name.

       If  the  SAS address (of the SMP target) is not given and it is required (i.e.  it is not implicit in the
       device name) then the SMP_UTILS_SAS_ADDR environment variable is checked and if present its contents  are
       used  as  the SAS address. SAS addresses are usually given in hex indicated by a leading '0x' or trailing
       'h'.

       If either or both environment variables and the corresponding command line options are  given,  then  the
       command line options take precedence.

COMMON OPTIONS

       Mandatory  arguments  to  long  options  are  mandatory  for short options as well.  If an option takes a
       numeric argument then that argument is assumed to be decimal unless  otherwise  indicated  (e.g.  with  a
       leading "0x" or a trailing "h").

       -E, --expected=EX
              revision  4a  of  the SAS-2 draft introduced an 'expected expander change count' field in some SMP
              requests. The idea is to detect other SMP initiators trying to change the state  of  an  expander.
              The  value EX is from 0 to 65535 inclusive with 0 being the default value. When EX is greater than
              zero then if the value doesn't match the expander  change  count  of  the  SMP  target  (i.e.  the
              expander)  when the request arrives then the target ignores the request and sets a function result
              of "invalid expander change count" in the response.

       -h, --help
              output the usage message for the utility then exit.

       -H, --hex
              output the response in hexadecimal. This does not include the trailing CRC field.

       -I, --interface=PARAMS
              interface specific parameters. This option is usually not  needed  since  the  interface  type  is
              guessed  by  a utility based on the characteristics of the given SMP_DEVICE argument or what is in
              the corresponding environment variables. PARAMS is  of  the  form:  INTF[,force].   If  the  guess
              doesn't  work  then  the  interface  can  be specified by giving a INTF of either 'mpt' or 'sgv4'.
              Sanity checks are still performed and a utility may refuse if it  doesn't  agree  with  the  given
              INTF.  If  the  user is really sure then adding a ',force' will force the utility to use the given
              interface.

       -r, --raw
              send the response to stdout in binary. This does not include the trailing  CRC  field.  All  error
              messages are sent to stderr.

       -s, --sa=SAS_ADDR
              specifies the SAS address of the SMP target device. Typically this is an expander. This option may
              not  be  needed if the SMP_DEVICE has the target's SAS address associated with it. The SAS_ADDR is
              in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either
              prefix it with '0x' or put a trailing 'h' on it. If this option is not given then the value in the
              environment variable SMP_UTILS_SAS_ADDR is used.

       -v, --verbose
              increase the verbosity of the output. Can be used multiple times.

       -V, --version
              print the version string and then exit.

EXIT STATUS

       To aid scripts that call these utilities, the exit status is set to indicate success (0) or failure (1 or
       more):

       0      success

       1 - 63 reserved for SMP function result codes. See the SAS-2 (or later) draft,  in  the  section  on  the
              application  layer,  drilling  down further: management application layer then SMP functions. Here
              are some common function result codes: 1 [unknown SMP function], 2 [SMP function failed], 16  [phy
              does  not  exist],  17  [index  does  not  exist], 18 [phy does not support SATA], 19 [unknown phy
              operation], 22 [phy vacant] and 35 [zone lock violation].

       91     syntax error. Either illegal options, options with bad arguments or a combination of options  that
              is not permitted.

       92     the  utility  is  unable to open, close or use the given SMP_DEVICE.  The given file name could be
              incorrect or there may be file permission problems. Adding the  --verbose  option  may  give  more
              information.

       97     the response to an SMP function failed sanity checks.

       99     any  error  that  can't  be  categorized  into values 1 to 97 may yield this value.  This includes
              transport and operating system errors.

NOTES

       Finding the SAS address of an expander can be a challenge in some environments. An  enclosure  containing
       one or more expanders may have the expander SAS address(es) printed on the back of the device, a bit like
       Ethernet MAC addresses.

       In  the  Linux  2.6  kernel  series  the expander SAS address may well be in the sysfs tree but it is not
       always easy to find. Doing this search may help:

         # find /sys -name "*expander*"

       That should show the suffix on  any  expanders  that  have  been  detected.  Then  a  command  like  'cat
       /sys/class/sas_device/expander-6:0/sas_address' should show its SAS address.

       Another  approach is to work backwards from SCSI devices (i.e. logical units). The protocol specific port
       log page (log page 18h) contains fields for the "attached SAS address".  The  sg_logs  utility  from  the
       sg3_utils package could be used like this:

         # sg_logs --page=18h /dev/sdb

       Any given "attached SAS address" is either a HBA, an expander or 0 indicating that port is not connected.
       An expander is indicated by "attached device type: expander device". A SAS disk's target port identifiers
       (also known as SAS addresses), device name and logical unit name (all NAA 5 format) can be found with the
       sg_vpd  utility  (e.g. 'sg_vpd -i <disk_dev>'). The sdparm utility can provide the same information (e.g.
       'sdparm -i <disk_dev>').

       A SAS expander is often associated with a SCSI Enclosure Services (SES)  device  sometimes  on  the  same
       silicon  attached via a virtual phy to the expander. That SES device may be able to access and control an
       attached enclosure or backplane via SGPIO or I2C on sideband signals  (e.g.  in  a  SFF-8087  cable).  To
       interact with a SES device, see the sg_ses utility.

       Often  expander  phys are grouped in fours on the same connector (e.g.  SFF-8088). Care needs to be taken
       when multiple expanders are interconnected.  An enclosure universal port is one in which  the  "table  to
       table supported" attribute is set (in the REPORT GENERAL response) and the associated phys have the table
       routing attribute (in the DISCOVER response). Enclosure universal ports were introduced in SAS-2 and have
       few  restrictions  when  used  to interconnect expanders or connect SAS or SATA devices. An enclosure out
       port is one in which the "table to table supported" attribute is clear and the associated phys  have  the
       table  routing  attribute.  An enclosure in port is one in which the associated phys have the subtractive
       routing attribute. When universal ports are not available, an expander interconnect should be between  an
       in port and an out port.

EXAMPLES

       See "Examples" section in http://sg.danny.cz/sg/smp_utils.html .

CONFORMING TO

       SAS  has  multiple generations. The early standards are: the original SAS (ANSI INCITS 376-2003), SAS 1.1
       (INCITS 417-2006) and SAS-2 (ANSI INCITS 457-2010) . SAS-2.1  work  was  split  into  an  electrical  and
       physical  layers  document  (standardized  as  SAS-2.1  ANSI INCITS 478-2011) with the upper level layers
       placed in a document called the SAS Protocol Layer and it was standardized as SPL ANSI  INCITS  476-2011.
       Next  came  SPL-2 which was standardized as SPL-2 ANSI INCITS 505-2013. SPL-3 is near standardization and
       its most recent draft is spl3r07.pdf. To avoid  confusion,  the  multiple  generations  of  SAS  will  be
       referred  to  in  these  man  pages as SAS 1, 1.1, 2, 2.1 (SPL) and 3 (SPL-2 and SPL-3). Roughly speaking
       SAS-1 runs at 3 Gbps, SAS-2 at 6 Gbps and SAS-3 at 12  Gbps.   Drafts,  including  those  just  prior  to
       standardization  can  be found at the http://www.t10.org site (e.g. spl-r07.pdf and spl2r04c.pdf). INCITS
       policy now requires a registration to view these drafts, a break from t10.org tradition.

       The two utilities for reading and writing  to  GPIO  registers,  smp_read_gpio  and  smp_write_gpio,  are
       defined  in  the  Small  Form  Factor document SFF-8485 found at http://www.sffcommittee.com . "Enhanced"
       versions of the corresponding SMP functions have been mentioned in some drafts but  no  definitions  have
       been published and the references have been removed in more recent drafts.

       In  this  section  of  each utility's man page is the first standard in which the associated SMP function
       appeared and whether there have been significant additions in later standards.

       The COVERAGE file in the smp_utils source tarball shows a table of all SMP function names defined in  the
       drafts, the versions of those standards in which those SMP functions first appeared and the corresponding
       smp_utils utility names. A lot of extra SMP functions have been added in SAS-2 associated with zoning.

AUTHORS

       Written by Douglas Gilbert.

REPORTING BUGS

       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

       Copyright © 2006-2014 Douglas Gilbert
       This  software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY
       or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

       sg_logs, sg_vpd, sg_ses(sg3_utils); sdparm(sdparm); lsscsi(lsscsi)

smp_utils-0.98                                      May 2014                                        SMP_UTILS(8)