Provided by: ion_3.2.1+dfsg-1.1_amd64 bug

NAME

       bpsource - Bundle Protocol transmission test shell

SYNOPSIS

       bpsource destinationEndpointId ['text'] [-tTTL]

DESCRIPTION

       When text is supplied, bpsource simply uses Bundle Protocol to send text to a counterpart
       bpsink application task that has opened the BP endpoint identified by
       destinationEndpointId, then terminates.

       Otherwise, bpsource offers the user an interactive "shell" for testing Bundle Protocol
       data transmission.  bpsource prints a prompt string (": ") to stdout, accepts a string of
       text from stdin, uses Bundle Protocol to send the string to a counterpart bpsink
       application task that has opened the BP endpoint identified by destinationEndpointId, then
       prints another prompt string and so on.  To terminate the program, enter a string
       consisting of a single exclamation point (!) character.

       TTL indicates the number of seconds the bundles may remain in the network, undelivered,
       before they are automatically destroyed. If omitted, TTL defaults to 300 seconds.

       The source endpoint ID for each bundle sent by bpsource is the null endpoint ID, i.e., the
       bundles are anonymous.  All bundles are sent standard priority with no custody transfer
       and no status reports requested.

EXIT STATUS

       "0" bpsource has terminated.  Any problems encountered during operation will be noted in
           the ion.log log file.

FILES

       The service data units transmitted by bpsource are sequences of text obtained from a file
       in the current working directory named "bpsourceAduFile", which bpsource creates
       automatically.

ENVIRONMENT

       No environment variables apply.

DIAGNOSTICS

       Diagnostic messages produced by bpsource are written to the ION log file ion.log.

       Can't attach to BP.
           bpadmin has not yet initialized Bundle Protocol operations.

       bpsource fgets failed
           Operating system error.  Check errtext, correct problem, and rerun.

       No space for ZCO extent.
           ION system error.  Check for earlier diagnostic messages describing the cause of the
           error; correct problem and rerun.

       Can't create ZCO extent.
           ION system error.  Check for earlier diagnostic messages describing the cause of the
           error; correct problem and rerun.

       bpsource can't send ADU
           Bundle Protocol service to the remote endpoint has been stopped.

BUGS

       Report bugs to <ion-bugs@korgano.eecs.ohiou.edu>

SEE ALSO