Provided by: ndctl_67-1_amd64 

NAME
ndctl-inject-smart - perform smart threshold/injection operations on a DIMM
SYNOPSIS
ndctl inject-smart <dimm> [<options>]
DESCRIPTION
A generic DIMM device object, named /dev/nmemX, is registered for each memory device indicated in the ACPI NFIT table, or other platform NVDIMM resource discovery mechanism. ndctl-inject-smart can be used to set smart thresholds, and inject smart attributes.
EXAMPLES
Set smart controller temperature and spares threshold for DIMM-0 to 32C, spares threshold to 8, and enable the spares alarm. ndctl inject-smart --ctrl-temperature-threshold=32 --spares-threshold=8 --spares-alarm nmem0 Inject a media temperature value of 52 and fatal health status flag for DIMM-0 ndctl inject-smart --media-temperature=52 --health=fatal nmem0
OPTIONS
-b, --bus= Enforce that the operation only be carried on devices that are attached to the given bus. Where bus can be a provider name or a bus id number. -m, --media-temperature= Inject <value> for the media temperature smart attribute. -M, --media-temperature-threshold= Set <value> for the smart media temperature threshold. --media-temperature-alarm= Enable or disable the smart media temperature alarm. Options are on or off. --media-temperature-uninject Uninject any media temperature previously injected. -c, --ctrl-temperature= Inject <value> for the controller temperature smart attribute. -C, --ctrl-temperature-threshold= Set <value> for the smart controller temperature threshold. --ctrl-temperature-alarm= Enable or disable the smart controller temperature alarm. Options are on or off. --ctrl-temperature-uninject Uninject any controller temperature previously injected. -s, --spares= Inject <value> for the spares smart attribute. -S, --spares-threshold= Set <value> for the smart spares threshold. --spares-alarm= Enable or disable the smart spares alarm. Options are on or off. --spares-uninject Uninject any spare percentage previously injected. -f, --fatal Set the flag to spoof fatal health status. --fatal-uninject Uninject the fatal health status flag. -U, --unsafe-shutdown Set the flag to spoof an unsafe shutdown on the next power down. --unsafe-shutdown-uninject Uninject the unsafe shutdown flag. -N, --uninject-all Uninject all possible smart fields/values irrespective of whether they have been previously injected or not. -v, --verbose Emit debug messages for the error injection process -u, --human Format numbers representing storage sizes, or offsets as human readable strings with units instead of the default machine-friendly raw-integer data. Convert other numeric fields into hexadecimal strings.
COPYRIGHT
Copyright (c) 2016 - 2019, Intel Corporation. License GPLv2: GNU GPL version 2 http://gnu.org/licenses/gpl.html. This is free software: you are free to change and redistribute it. There is NO WARRANTY, to the extent permitted by law.
SEE ALSO
ndctl-list(1),