Provided by: libmodbus-dev_3.1.6-2_amd64 

NAME
modbus_connect - establish a Modbus connection
SYNOPSIS
int modbus_connect(modbus_t *ctx);
DESCRIPTION
The modbus_connect() function shall establish a connection to a Modbus server, a network or a bus using
the context information of libmodbus context given in argument.
RETURN VALUE
The function shall return 0 if successful. Otherwise it shall return -1 and set errno to one of the
values defined by the system calls of the underlying platform.
EXAMPLE
modbus_t *ctx;
ctx = modbus_new_tcp("127.0.0.1", 502);
if (modbus_connect(ctx) == -1) {
fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
modbus_free(ctx);
return -1;
}
SEE ALSO
modbus_close(3)
AUTHORS
The libmodbus documentation was written by Stéphane Raimbault <stephane.raimbault@gmail.com>
libmodbus v3.1.6 12/09/2019 MODBUS_CONNECT(3)