NAME

       sg_modes - reads mode pages with SCSI MODE SENSE command

SYNOPSIS

       sg_modes  [--all]  [--control=PC]  [--dbd]  [--dbout]  [--examine] [--flexible] [--help] [--hex] [--list]
       [--llbaa] [--maxlen=LEN] [--page=PG[,SPG]] [--raw] [-R]  [--readwrite]  [--six]  [--verbose]  [--version]
       [DEVICE]

       sg_modes  [-6]  [-a]  [-A]  [-c=PC]  [-d]  [-D] [-e] [-f] [-h] [-H] [-l] [-L] [-m=LEN] [-p=PG[,SPG]] [-r]
       [-subp=SPG] [-v] [-V] [-w] [-?] [DEVICE]

DESCRIPTION

       This utility sends a MODE SENSE SCSI command to the DEVICE and outputs the response. There is  a  6  byte
       and  10  byte  (cdb) variant of the MODE SENSE command, this utility defaults to the 10 byte variant. The
       SPC-4 standard (and SPC-5 drafts) include a note stating that implementers should migrate away  from  the
       SCSI MODE SELECT(6) and MODE SENSE(6) commands in favour of the 10 byte variants (e.g.  MODE SENSE(10)).

       This  utility  decodes mode page headers and block descriptors but outputs the contents of each mode page
       in hex. It also has no facility to change the mode page contents or  block  descriptor  data.  Mode  page
       contents are decoded and can be changed by the sdparm utility.

       This  utility  supports  two  command line syntaxes, the preferred one is shown first in the synopsis and
       explained in this section. A later section on the old command line syntax outlines the  second  group  of
       options.

       If  no  page  is  given (and --list is not selected) then --all is assumed. The --all option requests all
       mode pages (but not subpages) in a single response.

OPTIONS

       Arguments to long options are mandatory for short options as well.

       -a, --all
              output all the mode pages reported by the DEVICE. This is what the page code 63 (0x3f) is  defined
              to do. When used once, mode subpages are not fetched. When used twice (e.g. '-aa'), all mode pages
              and subpages are requested which is equivalent to '--page=63,255'.

       -c, --control=PC
              PC is the page control value. Up to four different versions of each page are held by the device:
                0 : current values (i.e. those active at present)
                1 : changeable values
                2 : default values (i.e. the manufacturer's settings)
                3 : saved values
              The  changeable values are bit masks showing which fields could be changed with a MODE SELECT. The
              saved values will be re-instated the next time the device is power cycled or reset. If this option
              is not given then current values [0] are assumed.

       -d, --dbd
              disable block descriptors. By default, block descriptors (usually one (for  disks)  or  none)  are
              returned  in  a MODE SENSE response. This option sets the "disable block descriptors" (DBD) bit in
              the cdb which instructs the device not to return any block  descriptors  in  its  response.  Older
              devices  may not support this setting and may return an "illegal request" sense key; alternatively
              they may ignore it. Oddly the Reduced Block Command set (RBC) requires this bit set.

       -D, --dbout
              disable outputting block descriptors. Irrespective of whether block descriptors are present in the
              response or not, they are not output.

       -e, --examine
              examine each mode page in the range 0 through to 62 (inclusive).  If some response is  given  then
              print out the mode page name or number (in hex) if the name is not known.

       -f, --flexible
              Some  devices,  bridges and/or drivers attempt crude translations between MODE SENSE 6 and 10 byte
              commands without correcting the response. This will  cause  the  response  to  be  mis-interpreted
              (usually  with  an  error  saying  the response is malformed). With this option, the length of the
              response is checked, and if it looks wrong, the response is then decoded  as  if  the  other  mode
              sense (cdb length) was sent.

       -h, --help
              print out the usage message then exit.

       -H, --hex
              The default action is to decode known mode page numbers (and subpage numbers) into text. When this
              option  is  used  once,  the response is output in hexadecimal to stdout. When this option is used
              twice, mode page numbers and page control values are output in hex.
              When this option is used three times, the full response to the MODE SENSE command is output in hex
              to stdout without any decoding. This form can be redirected to a file (or  piped)  and  then  used
              'sdparm --inhex=' to decode.

       -l, --list
              lists  all  common  page  and subpage codes and their names that are found in the command set that
              matches the peripheral type of the given DEVICE.  If no DEVICE and no --page=PG is given then  the
              common  page  and  subpage codes and their names are listed for SBC (e.g. a disk). If no DEVICE is
              given and a --page=PG is given then the common page and subpage codes and their names  are  listed
              for  the  command  set  whose  peripheral  device  type matches the value given to PG. For example
              'sg_mode --list --page=1' lists the command mode pages and subpages for tape devices. Additionally
              if a sub_page_code is given then it is interpreted as a transport identifier and command transport
              specific mode page codes and their names are listed following the  main  mode  page  list.   Other
              options are ignored.

       -L, --llbaa
              set  the  Long LBA Accepted (LLBAA) bit in the MODE SENSE (10) cdb. This bit is not defined in the
              MODE SENSE (6) cdb so setting the '-L' and '--six' options is reported as an error. When  set  the
              DEVICE  may  respond  with  16  byte  block descriptors as indicated by the 'LongLBA' field in the
              response. In most cases setting this option is not needed.

       -m, --maxlen=LEN
              The LEN argument is the maximum response length in bytes. It is the 'allocation length'  field  in
              the  cdb. When not given (or LEN is zero) then the allocation length field is set to 4096 for MODE
              SENSE (10) or 252 for MODE SENSE (6). The LEN argument must be non-negative and  no  greater  than
              65535 for MODE SENSE (10) and not greater than 255 for MODE SENSE (6).

       -O, --old
              Switch to older style options. Please use as first option.

       -p, --page=PG
              page  code  to  fetch.  The  PG  is assumed to be a decimal value unless prefixed by '0x' or has a
              trailing 'h'. It should be a value between 0 and 63 (inclusive). When not given and a  default  is
              required then a value of 63 (0x3f), which fetches all mode pages, is used.
              Alternatively  an acronym for the mode page can be given. The available acronyms can be listed out
              with the --page=xxx option. They are almost the same as the acronyms used for mode  pages  in  the
              sdparm utility.

       -p, --page=PG,SPG
              page  code  and  subpage  code  values  to  fetch. Both arguments are assumed to be decimal unless
              flagged as hexadecimal. The page code should be between 0  and  63  inclusive.  The  subpage  code
              should be between 0 and 255 inclusive. The default value for the subpage code is 0.

       -r, --raw
              output  the response in binary to stdout. Error messages and warnings, if any, are sent to stderr.
              When this option is used twice (e.g. '-rr') then has the same action as '-R'

       -R     output the selected mode page to stdout a byte per line. Each line contains two hexadecimal digits
              (e.g. "3e"). Useful as input (after editing) to the sg_wr_mode(8) utility.

       -w, --readwrite
              open DEVICE in "read-write" mode. Default is to open it in read-only mode.

       -6, --six
              by default this utility sends a 10 byte MODE SENSE  command  to  the  DEVICE.  However  some  SCSI
              devices  only  support 6 byte MODE SENSE commands (e.g. SCSI-2 tape drives). This parameter forces
              the use of 6 byte MODE SENSE commands.

       -v, --verbose
              increase level of verbosity. Can be used multiple times.

       -V, --version
              print out version string then exit.

NOTES

       If the normal sg_modes utility fails with "illegal command operation code" then try the '--six' (or '-6')
       option.

       This utility performs a SCSI INQUIRY command to determine the peripheral type of the device  (e.g.  0  ->
       Direct  Access  Device  (disk))  prior  to sending a MODE SENSE command. This helps in decoding the block
       descriptor and mode pages.

       This utility opens DEVICE in read-only mode (e.g. in Unix, with the O_RDONLY flag) by  default.  It  will
       open DEVICE in read-write mode if the --readwrite option is given.

       In the 2.4 series of Linux kernels the DEVICE must be a SCSI generic (sg) device. In the 2.6 series block
       devices  (e.g.  SCSI disks and DVD drives) can also be specified. For example "sg_modes -a /dev/sda" will
       work in the 2.6 series kernels.

EXIT STATUS

       The exit status of sg_modes is 0 when it is successful. Otherwise see the sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS

       The options in this section were the only ones available prior to sg3_utils version  1.23  .  Since  then
       this utility defaults to the newer command line options which can be overridden by using --old (or -O) as
       the  first  option. See the ENVIRONMENT VARIABLES section for another way to force the use of these older
       command line options.

       -6     by default this utility sends a 10 byte MODE SENSE command to the DEVICE.  This  parameter  forces
              the use of 6 byte MODE SENSE commands.  See --six in the main description.

       -a     see --all in the main description.

       -A     output  all  the mode pages and subpages supported by the DEVICE. Same as '--all --all' in the new
              syntax.

       -c=PC  PC is the page control value. See --control=PC in the main description.

       -d     see --dbd in the main description.

       -D     see --dbout in the main description.

       -e     see --examine in the main description.

       -f     see --flexible in the main description.

       -h     The default action is to decode known mode page numbers (and subpage numbers) into text. With this
              option mode page numbers (and subpage numbers) are output in hexadecimal.

       -H     same action as the '-h' option.

       -l     see --list in the main description.

       -L     see --llbaa in the main description.

       -N, --new
              Switch to the newer style options.

       -m=LEN see --maxlen=LEN in the main description.

       -p=PG  PG is page code to fetch. Should be a hexadecimal number between 0  and  3f  inclusive  (0  to  63
              decimal).  The  default value when required is 3f (fetch all mode pages). Note that an acronym for
              the page and/or subpage values is not accepted in this older format (because any acronym  starting
              with the letters 'a' to 'f' is ambiguous; it could either be a hex number or an acronym).

       -p=PG,SPG
              page code and subpage code values to fetch. The page code should be a hexadecimal number between 0
              and  3f inclusive. The subpage code should be a hexadecimal number between 0 and ff inclusive. The
              default value for the subpage code is 0.

       -r     output the selected mode page to stdout a byte per line. Each line contains two hexadecimal digits
              (e.g. "3e"). Useful as input (after editing) to the sg_wr_mode(8) utility.

       -subp=SPG
              sub page code to fetch. Should be a hexadecimal number between 0 and 0xff inclusive.  The  default
              value is 0.

       -v     increase verbosity of output.

       -V     print out version string then exit.

       -w     see --readwrite in the main description.

       -?     output usage message then exit. Ignore all other parameters.

ENVIRONMENT VARIABLES

       Since sg3_utils version 1.23 the environment variable SG3_UTILS_OLD_OPTS can be given. When it is present
       this  utility will expect the older command line options. So the presence of this environment variable is
       equivalent to using --old (or -O) as the first command line option.

AUTHOR

       Written by Douglas Gilbert

REPORTING BUGS

       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

       Copyright © 2000-2018 Douglas Gilbert
       This software is distributed under the GPL version 2. There is NO warranty; not even for  MERCHANTABILITY
       or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

       sdparm(8), sg_wr_mode(8), sginfo(8), sgmode(scsirastools), scsiinfo(net), scu(net), seatools(seagate)

       All these utilities offer some facility to change mode page (or block descriptor) parameters.

sg3_utils-1.43                                   September 2018                                      SG_MODES(8)