Provided by: sg3-utils_1.44-1ubuntu2_amd64 bug

NAME

       sg_readcap - send SCSI READ CAPACITY command

SYNOPSIS

       sg_readcap   [--16]  [--brief]  [--help]  [--hex]  [--lba=LBA]  [--long]  [--pmi]  [--raw]
       [--readonly] [--verbose] [--version] DEVICE

       sg_readcap [-16] [-b] [-h] [-H] [-lba=LBA] [-pmi] [-r] [-R] [-v] [-V] DEVICE

DESCRIPTION

       The normal action of the SCSI READ CAPACITY command is to fetch the number of blocks  (and
       block size) from the DEVICE.

       The SCSI READ CAPACITY command (both 10 and 16 byte cdbs) actually yield the block address
       of the last block and the block size. The number of blocks is  thus  one  plus  the  block
       address  of  the  last  block  (as  blocks are counted origin zero (i.e. starting at block
       zero)). This is the source of many "off by one" errors.

       The READ CAPACITY(16) response provides additional  information  not  found  in  the  READ
       CAPACITY(10)   response.   This   includes   protection  and  logical  block  provisioning
       information, plus the number of logical blocks per physical  block.  So  even  though  the
       media  size  may  not  exceed  what  READ CAPACITY(10) can show, it may still be useful to
       examine the response to READ CAPACITY(16). Sadly  there  are  horrible  SCSI  command  set
       implementations in the wild that crash when the READ CAPACITY(16) command is sent to them.

       Device  capacity  is  the product of the number of blocks by the block size.  This utility
       outputs this figure in bytes, MiB (1048576 bytes per MiB), GB (1000000000  bytes  per  GB)
       and, if large enough, TB (1000 GB).

       If  sg_readcap is called without the --long option then the 10 byte cdb version (i.e. READ
       CAPACITY (10)) is sent to the DEVICE. If the number of blocks in the response is  reported
       as  0xffffffff  (i.e.  (2**32  -  1)  ) and the --hex option has not been given, then READ
       CAPACITY (16) is called and its response is output.

       This utility supports two command line syntaxes, the preferred one is shown first  in  the
       synopsis  and  explained  in  this section. A later section on the old command line syntax
       outlines the second group of options.

OPTIONS

       Arguments to long options are mandatory for  short  options  as  well.   The  options  are
       arranged in alphabetical order based on the long option name.

       --16   Use  the 16 byte cdb variant of the READ CAPACITY command. See the '--long' option.
              -b, --brief outputs two hex numbers (prefixed with '0x'  and  space  separated)  to
              stdout.  The  first  number is the maximum number of blocks on the device (which is
              one plus the lba of the last accessible block). The second number is  the  size  in
              bytes of each block. If the operation fails then "0x0 0x0" is written to stdout.

       -h, --help
              print out the usage message then exit.

       -H, --hex
              output  the  response  to  the  READ CAPACITY command (either the 10 or 16 byte cdb
              variant) in ASCII hexadecimal on stdout.

       -L, --lba=LBA
              used in conjunction with --pmi option. This variant of READ CAPACITY will yield the
              last  block  address  after LBA prior to a delay. For a disk, given a LBA it yields
              the highest numbered block on the same cylinder (i.e.  before  the  heads  need  to
              move).  LBA  is  assumed to be decimal unless prefixed by "0x" or it has a trailing
              "h". Defaults to 0.  This option was made obsolete in SBC-3 revision 26.

       -l, --long
              Use the 16 byte cdb variant of the READ CAPACITY command. The default action is  to
              use  the 10 byte cdb variant which limits the maximum block address to (2**32 - 2).
              When a 10 byte cdb READ CAPACITY command is used on a  device  whose  size  is  too
              large  then  a last block address of 0xffffffff is returned (if the device complies
              with SBC-2 or later).

       -O, --old
              Switch to older style options. Please use as first option.

       -p, --pmi
              partial medium indicator: for finding the next block address prior  to  some  delay
              (e.g. head movement). In the absence of this option, the total number of blocks and
              the block size of the device are output.  Used in conjunction  with  the  --lba=LBA
              option. This option was made obsolete in SBC-3 revision 26.

       -r, --raw
              output response in binary to stdout.

       -R, --readonly
              open  the  DEVICE read-only (e.g. in Unix with the O_RDONLY flag).  The default for
              READ CAPACITY(16) is to open it read-write. The default for READ CAPACITY(10) is to
              open it read-only so this option does not change anything for this case.

       -v, --verbose
              increase level of verbosity. Can be used multiple times.

       -V, --version
              outputs version string then exits.

NOTES

       The  response to READ CAPACITY(16) contains a LBPRZ bit in the SBC-3 standard (ANSI INCITS
       514-2014). There was also a  LBPRZ  bit  with  the  same  meaning  in  the  Logical  block
       provisioning  VPD page (0xb2). Then somewhat confusingly T10 expanded the LBPRZ bit to a 3
       bit field in SBC-4 draft revision 7, but only in the LB provisioning VPD page. The  reason
       for the expansion was to report a new "provisioning initialization pattern" state (when an
       unmapped logical block is read). The new state has been assigned LBPRZ=2 in the  VPD  page
       and it re-uses LBPRZ=0 in the READ CAPACITY(16) response. LBPRZ=1 retains the same meaning
       for both variants, namely that a block of zeroes will be returned when an unmapped logical
       block is read.

EXIT STATUS

       The  exit  status of sg_readcap is 0 when it is successful. Otherwise see the sg3_utils(8)
       man page.

OLDER COMMAND LINE OPTIONS

       The options in this section were the only ones available prior to sg3_utils version 1.23 .
       Since then this utility defaults to the newer command line options which can be overridden
       by using --old (or -O) as the first option. See  the  ENVIRONMENT  VARIABLES  section  for
       another way to force the use of these older command line options.

       -16    Use  the 16 byte cdb variant of the READ CAPACITY command.  Equivalent to --long in
              the main description.

       -b     utility outputs two hex numbers (prefixed with '0x' and space separated) to stdout.
              The  first  number is the maximum number of blocks on the device (which is one plus
              the lba of the last accessible block). The second number is the size of each block.
              If  the operation fails then "0x0 0x0" is written to stdout.  Equivalent to --brief
              in the main description.

       -h     output the usage message then exit. Giving the -? option  also  outputs  the  usage
              message then exits.

       -H     output  the  response  to  the  READ CAPACITY command (either the 10 or 16 byte cdb
              variant) in ASCII hexadecimal on stdout.

       -lba=LBA
              used in conjunction with -pmi option. This variant of READ CAPACITY will yield  the
              last block address after LBA prior to a delay.  Equivalent to --lba=LBA in the main
              description.

       -N, --new
              Switch to the newer style options.

       -pmi   partial medium indicator: for finding the next block address prior  to  some  delay
              (e.g. head movement). In the absence of this switch, the total number of blocks and
              the block size of  the  device  are  output.   Equivalent  to  --pmi  in  the  main
              description.

       -r     output response in binary (to stdout).

       -R     Equivalent to --readonly in the main description.

       -v     verbose:  print out cdb of issued commands prior to execution. '-vv' and '-vvv' are
              also accepted yielding greater verbosity.

       -V     outputs version string then exits.

ENVIRONMENT VARIABLES

       Since sg3_utils version 1.23 the environment variable  SG3_UTILS_OLD_OPTS  can  be  given.
       When  it  is  present  this  utility  will  expect  the older command line options. So the
       presence of this environment variable is equivalent to using --old (or -O)  as  the  first
       command line option.

AUTHORS

       Written by Douglas Gilbert

COPYRIGHT

       Copyright © 1999-2018 Douglas Gilbert
       This  software  is distributed under the GPL version 2. There is NO warranty; not even for
       MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

       sg_inq(sg3_utils)