Provided by: libncarg-dev_6.6.2-10build2_amd64 

NAME
ginq_clip - Inquire GKS clipping indicator
DESCRIPTION
ginq_clip (Inquire clipping indicator) - retrieves the current value of the clipping indicator as well as
the current clipping rectangle.
SYNOPSIS
#include <ncarg/gks.h>
void ginq_clip(Gint *err_ind, Gclip *clip_ind_rect);
DESCRIPTION
err_ind (Output) - If the inquired values cannot be returned correctly, a non-zero error indicator is
returned in err_ind, otherwise a zero is returned. Consult "User's Guide for NCAR GKS-0A
Graphics" for a description of the meaning of the error indicators.
clip_ind_rect.clip_ind
(Output) - Returns the current value of the clipping indicator as set by default or by a call
to gset_clip_ind.
GIND_NO_CLIP
Clipping is off, or deactivated.
GIND_CLIP
Clipping is on. Data outside of the world coordinate window will not be plotted.
clip_ind_rect.clip_rect
(Glimit, Output) - Four normalized device coordinates providing the corner points of the
current clipping rectangle.
ACCESS
To use the GKS C-binding routines, load the ncarg_gks and ncarg_c libraries.
SEE ALSO
Online: set(3NCARG), gset_clip_ind(3NCARG), gset_win(3NCARG), gsel_norm_tran(3NCARG), gks(3NCARG),
ncarg_gks_cbind(3NCARG)
Hardcopy: User's Guide for NCAR GKS-0A Graphics; NCAR Graphics Fundamentals, UNIX Version
COPYRIGHT
Copyright (C) 1987-2009
University Corporation for Atmospheric Research
The use of this Software is governed by a License Agreement.
UNIX March 1993 GINQ_CLIP(3NCARG)