Provided by: cod-tools_3.4.0+dfsg-1build2_amd64
NAME
cif_p1 - expand atoms in CIF to the P1 space group, preserving molecules (i.e. outputting atoms that are bonded at bond distances from each other).
SYNOPSIS
cif_p1 --options input1.cif input*.cif
DESCRIPTION
Expand atoms in CIF to the P1 space group, preserving molecules (i.e. outputting atoms that are bonded at bond distances from each other).
OPTIONS
--always-continue Continue processing and return successful return status even if errors are diagnosed. -c-, --always-die Stop and return error status if errors are diagnosed. -1, --one-datablock-output Output all molecules and all alternative conformations to a single output data block. -1-, --multiple-datablocks-output Separate each molecule and each example of an alternative conformation into a separate data block. -c, --covalent-sensitivity Set a new covalent sensitivity value (default: 0.35). --simplify-formula Simplify chemical formula and output not the whole P1 cell but only a minimal stoichiometric set of molecules. Should have the same result as 'cif_molecule --preserve-stoichiometry'. --dont-simplify-formula, --no-simplify-formula Do not simplify formula, output the whole P1 cell (default). --exclude-zero-occupancies Do not use atoms with 0 occupancies in calculations (default). --dump-atoms Dump atoms (including symmetry-equivalent) in CIF format, for inspection with some graphics program. --dont-dump-atoms, --no-dump-atoms Do not dump atoms (default). -i, --ignore-bumps Detect and warn about close atom "bumps" but do not stop processing. --dont-ignore-bumps, --no-ignore-bumps Stop processing immediately if bumps are detected (default). --bump-distance-factor 0.75 A fraction of covalent bond radii sum used to determine when atoms are too close and are considered a bump. --max-polymer-span 4 A span, in +/- unit cells, in which polymeric molecules (repeating units) will be constructed. --max-polymer-atoms 100 A maximum allowed count of polymer example atoms: more than this amount of symmetry (translational) equivalent atoms, for each AU atom, will not be written to the output file: Using --max-polymer-span=0 --max-polymer-atoms=1 essentially switches off the polymer detection. --split-disorder-groups, --dont-merge-disorder-groups Put examples of disorder group conformations into separate data blocks (default). --merge-disorder-groups, --dont-split-disorder-groups Put all disorder groups into one data block. --use-perl-parser Use development CIF parser written in Perl. --use-c-parser Use faster C/Yacc CIF parser (default). --debug Print some human-readable debug output. --no-debug Suppress any debug output (default). --format "%8.6f" Use the specified format for output coordinate printout. --audit Print audit information to the generated CIF file (default). --no-audit Do not print audit information to the generated CIF file. --continue-on-errors Do not terminate script if errors such as unrecognised atoms are encountered; the output may be incorrect and missing some atoms if this option is used! --die-on-errors, --dont-continue-on-errors, --no-continue-on-errors Terminate script immediately if errors are raised (default). --continue-on-warnings Do not terminate script if warnings are raised (default). --die-on-warnings Terminate script immediately if warnings are raised. --continue-on-notes Do not terminate script if notes are raised (default). --die-on-notes Terminate script immediately if notes are raised. --verbose Print warning messages in long format. --no-verbose Print warning messages in concise format (default). --help, --usage Output a short usage message (this message) and exit. --version Output version information and exit.
REPORTING BUGS
Report cif_p1 bugs using e-mail: cod-bugs@ibt.lt CIF_P1(1)