Provided by: nvme-cli_1.16-3ubuntu0.3_amd64 

NAME
nvme-write-zeroes - Send an NVMe write zeroes command, return results
SYNOPSIS
nvme-write-zeroes <device> [--start-block=<slba> | -s <slba>]
[--block-count=<nlb> | -c <nlb>]
[--ref-tag=<reftag> | -r <reftag>]
[--prinfo=<prinfo> | -p <prinfo>]
[--app-tag-mask=<appmask> | -m <appmask>]
[--app-tag=<apptag> | -a <apptag>]
[--deac | -d]
[--limited-retry | -l]
[--force-unit-access | -f]
[--namespace-id=<nsid> | -n <nsid>]
[--storage-tag<storage-tag> | -S <storage-tag>]
[--storage-tag-check<storage-tag-check> | -C <storage-tag-check>]
DESCRIPTION
The Write Zeroes command is used to set a range of logical blocks to 0.
OPTIONS
--start-block=<slba>, -s <slba>
Start block.
--block-count=<nlb>, -c <nlb>
Number of logical blocks to write zeroes.
--prinfo=<prinfo>, -p <prinfo>
Protection Information field definition.
┌─────┬───────────────────────────────────────┐
│ Bit │ Description │
├─────┼───────────────────────────────────────┤
│ 3 │ PRACT: Protection Information Action. │
│ │ When set to 1, PI is │
│ │ stripped/inserted on read/write when │
│ │ the block format’s metadata size is │
│ │ 8. When set to 0, metadata is passes. │
├─────┼───────────────────────────────────────┤
│ 2:0 │ PRCHK: Protection Information Check: │
├─────┼───────────────────────────────────────┤
│ 2 │ Set to 1 enables checking the guard │
│ │ tag │
├─────┼───────────────────────────────────────┤
│ 1 │ Set to 1 enables checking the │
│ │ application tag │
├─────┼───────────────────────────────────────┤
│ 0 │ Set to 1 enables checking the │
│ │ reference tag │
└─────┴───────────────────────────────────────┘
--ref-tag=<reftag>, -r <reftag>
Optional reftag when used with protection information.
--app-tag-mask=<appmask>, -m <appmask>
Optional application tag mask when used with protection information.
--app-tag=<apptag>, -a <apptag>
Optional application tag when used with protection information.
--limited-retry, -l
Sets the limited retry flag.
--deac, -d
Sets the DEAC bit, requesting controller deallocate the logical blocks.
--force-unit-access, -f
Set the force-unit access flag.
--namespace-id=<nsid>, -n <nsid>
Namespace ID use in the command.
--storage-tag=<storage-tag>, -n <storage-tag>
Variable Sized Expected Logical Block Storage Tag(ELBST) and Expected Logical Block Reference Tag
(ELBRT), CDW2 and CDW3 (00:47) bits.
--storage-tag-check=<storage-tag-check>, -C <storage-tag-check>
This bit specifies the Storage Tag field shall be checked as part of end-to-end data protection
processing.
EXAMPLES
No examples yet.
NVME
Part of the nvme-user suite
NVMe 11/11/2021 NVME-ZEROES(1)