NAME

       sigrok-cli - Command-line client for the sigrok software

SYNOPSIS

       sigrok-cli [OPTIONS] [COMMAND]

DESCRIPTION

       sigrok-cli is a cross-platform command line utility for the sigrok software.

       It  cannot  display  graphical  output,  but  is still sufficient to run through the whole
       process of hardware initialization, acquisition, protocol decoding and saving the session.

       It is useful for running on remote or embedded systems, netbooks, PDAs,  and  for  various
       other  use-cases.  It  can display samples on standard output or save them in various file
       formats.

OPTIONS

       -h, --help
              Show a help text and exit.

       -V, --version
              Show sigrok-cli version and the versions of libraries used.

       -L, --list-supported
              Show information about supported hardware drivers, input file formats, output  file
              formats, and protocol decoders.

       --list-supported-wiki
              Show  information  about  supported protocol decoders in MediaWiki syntax.  This is
              generally only used by developers to easily update the list of  supported  protocol
              decoders in the sigrok wiki.

       -d, --driver <drivername>
              Unless  doing  a  global scan, users typically select one of the available drivers.
              This can  speedup  program  start,  and  can  avoid  false  matches  for  ambiguous
              configurations.  Selecting  a  driver  also  allows  to  pass  more driver specific
              options. Use the -L (--list-supported) option to get a list of available drivers.

              Drivers can take options, in the form key=value separated by colons.

              Drivers communicating with  hardware  via  a  serial  port  always  need  the  port
              specified as the conn option. For example, to use the Openbench Logic Sniffer:

                $ sigrok-cli --driver=ols:conn=/dev/ttyACM0 [...]

              Some  USB  devices don't use a unique VendorID/ProductID combination, and thus need
              that specified as well. Notice that colons are used to  separate  the  driver  name
              from the conn option, thus colons cannot be used within the conn option's argument.
              To select a specific USB device, use either VendorID.ProductID or bus.address:

              USB VendorID.ProductID example:

                $ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 [...]

              USB bus.address example:

                $ sigrok-cli --driver=uni-t-ut61e:conn=4.6 [...]

       -D, --dont-scan
              Do not automatically scan for device drivers in the  absence  of  a  -d  (--driver)
              specification.

       -c, --config <deviceoption>
              A  colon-separated  list  of  device  options,  where  each  option  takes the form
              key=value.  Multiple occurances of the --config option are  supported.   The  first
              item  in  the  list  of  options can take the form channel_group=<name> which would
              override the --channel-group specification for this list of options.  Other  option
              lists  in  other  --config occurances are not affected by this list's channel group
              name.

              For example, to set the samplerate to 1MHz on a device  supported  by  the  fx2lafw
              driver, you might specify

                $ sigrok-cli -d fx2lafw --config samplerate=1m [...]

              Samplerate  is an option common to most logic analyzers. The argument specifies the
              samplerate in Hz. You can also specify the samplerate in  kHz,  MHz  or  GHz.   The
              following are all equivalent:

                $ sigrok-cli -d fx2lafw --config samplerate=1000000 [...]

                $ sigrok-cli -d fx2lafw --config samplerate=1m [...]

                $ sigrok-cli -d fx2lafw --config "samplerate=1 MHz" [...]

              These  examples  specify  options  within  a  channel  group.   The  first  two are
              equivalent.

                $ sigrok-cli -d demo --channel-group Logic --config pattern=random [...]

                $ sigrok-cli -d demo --config channel_group=Logic:pattern=random [...]

                    $     sigrok-cli     -d     demo     --config     samplerate=1m      --config
              channel_group=Logic:pattern=random [...]

       -i, --input-file <filename>
              Load  input  from  a  file instead of a hardware device. You can specify "-" to use
              stdin as input. If the --input-format option is not supplied,  sigrok-cli  attempts
              to autodetect the file format of the input file.

              Example for loading a sigrok session file:

                $ sigrok-cli -i example.sr [...]

              Example for loading a WAV file (autodetection of input format):

                $ sigrok-cli -i example.wav [...]

              Example for loading a VCD file from stdin (autodetection of input format):

                $ cat example.vcd | sigrok-cli -i - [...]

       -I, --input-format <format>
              When  loading an input file, assume it's in the specified format. If this option is
              not supplied (in addition to --input-file), sigrok-cli attempts to  autodetect  the
              file  format  of the input file. Use the -L (--list-supported) option to see a list
              of available input formats.

              The format name may optionally be followed by a colon-separated  list  of  options,
              where each option takes the form key=value.

              Example for loading a binary file with options:

                $ sigrok-cli -i example.bin
                             -I binary:numchannels=4:samplerate=1mhz [...]

       -o, --output-file <filename>
              Save output to a file instead of writing it to stdout. The default format used when
              saving  is  the  sigrok  session  file  format.  This  can  be  changed  with   the
              --output-format option.

              Example for saving data in the sigrok session format:

                $ sigrok-cli [...] -o example.sr

       -O, --output-format <format>
              Set the output format to use. Use the -L (--list-supported) option to see a list of
              available output formats.

              The format name may optionally be followed by a colon-separated  list  of  options,
              where each option takes the form key=value.

              For  example,  the  bits  or  hex  formats,  for  an ASCII bit or ASCII hexadecimal
              display, can take a "width" option, specifying the number of samples (in  bits)  to
              display  per  line.  Thus  -O  hex:width=128  will  display  128  bits per line, in
              hexadecimal:

               0:ffff ffff ffff ffff ffff ffff ffff ffff
               1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00

              The lines always start with the channel number (or name, if defined), followed by a
              colon. If no format is specified, it defaults to bits:width=64, like this:

               0:11111111 11111111 11111111 11111111 [...]
               1:11111111 00000000 11111111 00000000 [...]

              Example for saving data in the CSV format with options:

                $ sigrok-cli [...] -o example.csv -O csv:dedup:header=false

              Notice that boolean options are true when no value gets specified.

       -C, --channels <channellist>
              A comma-separated list of channels to be used in the session.

              Note  that  sigrok  always names the channels according to how they're shown on the
              enclosure of the hardware. If your logic analyzer numbers the channels 0-15, that's
              how  you  must  specify  them  with  this  option. An oscilloscope's channels would
              generally be referred to as "CH1", "CH2", and so on.  Use the --show option to  see
              a list of channel names for your device.

              The  default  is  to  use  all  the  channels available on a device. You can name a
              channel like this: 1=CLK.  A range of channels can also be given, in the form 1-5.

              Example:

                $ sigrok-cli --driver fx2lafw --samples 100
                             --channels 1=CLK,2-4,7
               CLK:11111111 11111111 11111111 11111111 [...]
                 2:11111111 11111111 11111111 11111111 [...]
                 3:11111111 11111111 11111111 11111111 [...]
                 4:11111111 11111111 11111111 11111111 [...]
                 7:11111111 11111111 11111111 11111111 [...]

              The comma-separated list is processed from left to right, i.e. items farther to the
              right  override  previous  items.  For  example  1=CS,CS=MISO  will set the name of
              channel 1 to MISO.

       -g, --channel-group <channel group>
              Specify the channel group to  operate  on.  Some  devices  organize  channels  into
              groups,  the  settings of which can only be changed as a group. The list of channel
              groups, if any, is displayed with the --show command.

              Examples:

                $ sigrok-cli -g CH1 [...]

                $ sigrok-cli -d demo -g Logic -c pattern=graycode [...]

              Channel group specifications in --get or  --config  options  take  precedence  over
              channel  group  names in --channel-group so that a single sigrok-cli invocation can
              support the query or manipulation  of  multiple  device  options  which  reside  in
              different channel groups.

       -t, --triggers <triggerlist>
              A  comma-separated  list  of triggers to use, of the form <channel>=<trigger>.  You
              can use the name or number of the channel, and the trigger itself is  a  series  of
              characters:

              0 or 1: A low or high value on the pin.
              r or f: A rising or falling value on the pin. An r effectively corresponds to 01.
              e: Any kind of change on a pin (either a rising or a falling edge).

              Not every device supports all of these trigger types. Use the --show command to see
              which triggers your device supports.

       -w, --wait-trigger
              Don't output any sample data (even if it's actually  received  from  the  hardware)
              before  the trigger condition is met. In other words, do not output any pre-trigger
              data. This option is useful if you don't care about the data that came  before  the
              trigger (but the hardware delivers this data to sigrok nonetheless).

       -P, --protocol-decoders <list>
              This  option allows the user to specify a comma-separated list of protocol decoders
              to be used in this session. The decoders are specified by their ID, as shown in the
              -L (--list-supported) output.

              Example:

               $ sigrok-cli -i <file.sr> -P i2c

              Each  protocol  decoder  can  optionally  be  followed by a colon-separated list of
              options, where each option takes the form key=value.

              Example:

               $ sigrok-cli -i <file.sr>
                            -P uart:baudrate=115200:parity_type=odd

              The list of supported options depends  entirely  on  the  protocol  decoder.  Every
              protocol decoder has different options it supports.

              Any  "options"  specified  for  a protocol decoder which are not actually supported
              options, will be interpreted as being channel name/number assignments.

              Example:

               $ sigrok-cli -i <file.sr>
                            -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0

              In this example, wordsize is an option  supported  by  the  spi  protocol  decoder.
              Additionally,  the  user tells sigrok to decode the SPI protocol using channel 1 as
              MISO signal for SPI, channel 5 as MOSI, channel 3 as CLK,  and  channel  0  as  CS#
              signal.

              Notice  that  the  sigrok-cli application does not support "name matching". Instead
              it's assumed that the traces in the input stream match the order of  the  decoder's
              input signals, or that users explicitly specify the input channel to decoder signal
              mapping.

              When multiple decoders are specified in the same -P option, they will be stacked on
              top of each other in the specified order.

              Example:

               $ sigrok-cli -i <file.sr> -P i2c,eeprom24xx
               $ sigrok-cli -i <file.sr> -P uart:baudrate=31250,midi

              When  multiple  -P  options  are specified, each of them creates one decoder stack,
              which executes in parallel to other decoder stacks.

              Example:

               $ sigrok-cli -i <file.sr> -P uart:tx=D0:rx=D1 -P timing:data=D2

       -A, --protocol-decoder-annotations <annotations>
              By default, all annotation output of all protocol  decoders  is  shown.  With  this
              option  a specific decoder's annotations can be selected for display, by specifying
              the decoder ID:

               $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c

              If a protocol decoder has multiple annotation classes, you can also  specify  which
              one of them to show by specifying its short description like this:

               $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
                            -A i2c=data-read

              Select multiple annotation classes by separating them with a colon:

               $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
                            -A i2c=data-read:data-write

              Annotation  row  names  will  resolve to their respective list of classes.  Row and
              class names can be used in combination. When names are ambiguous then  class  names
              take precedence.

               $ sigrok-cli -i <file.sr> -P i2c
                            -A i2c=addr-data:warnings

              You can also select multiple protocol decoders, with optionally selected annotation
              classes each, by separating them with commas:

               $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
                            -A i2c=data-read:data-write,edid

       -M, --protocol-decoder-meta <pdname>
              When given, show protocol decoder meta output instead of annotations.  The argument
              is the name of the decoder whose meta output to show.

               $ sigrok-cli -i <file.sr> -M i2c

              Not every decoder generates meta output.

       -B, --protocol-decoder-binary <binaryspec>
              When  given,  decoder  "raw"  data of various kinds is written to stdout instead of
              annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP files, PNG
              files,  or  anything else; this is entirely dependent on the decoder and what kinds
              of binary output make sense for that decoder).

              No other information is printed to stdout, so this  is  suitable  for  piping  into
              other programs or saving to a file.

              Protocol  decoders that support binary output publish a list of binary classes, for
              example the UART decoder might have "TX" and "RX". To select  TX  for  output,  the
              argument to this option would be:

               $ sigrok-cli -i <file.sr> -B uart=tx

              If  only  the  protocol decoder is specified, without binary class, all classes are
              written to stdout:

               $ sigrok-cli -i <file.sr> -B uart

              (this is only useful in rare cases, generally you would specify  a  certain  binary
              class you're interested in)

              Not every decoder generates binary output.

       --protocol-decoder-samplenum
              When  given,  decoder  annotations  will  include sample numbers, too.  This allows
              consumers to receive machine readable timing information.

       -l, --loglevel <level>
              Set the libsigrok and libsigrokdecode loglevel. At the  moment  sigrok-cli  doesn't
              support  setting  the  two loglevels independently. The higher the number, the more
              debug output will be printed. Valid loglevels are:

              0   None
              1   Error
              2   Warnings
              3   Informational
              4   Debug
              5   Spew

       --show
              Show information about the selected option. For  example,  to  see  options  for  a
              connected fx2lafw device:

               $ sigrok-cli --driver fx2lafw --show

              In  order to properly get device options for your hardware, some drivers might need
              a serial port specified:

               $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show

              This also works for protocol decoders, input modules and output modules:

               $ sigrok-cli --protocol-decoders i2c --show
               $ sigrok-cli --input-format csv --show
               $ sigrok-cli --output-format bits --show

              This also works for input files, including optional input format specifications:

               $ sigrok-cli --input-file <file.sr> --show
               $ sigrok-cli --input-file <file.vcd> --input-format vcd --show

       --scan Scan for devices that can be detected automatically.

              Example:

               $ sigrok-cli --scan
               The following devices were found:
               demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3
               fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7

              However, not all devices are auto-detectable (e.g. serial port  based  ones).   For
              those you'll have to provide a conn option, see above.

               $ sigrok-cli --driver digitek-dt4000zc:conn=/dev/ttyUSB0 --scan
               The following devices were found:
               Digitek DT4000ZC with 1 channel: P1

       --time <ms>
              Sample for <ms> milliseconds, then quit.

              You can optionally follow the number by s to specify the time to sample in seconds.

              For example, --time 2s will sample for two seconds.

       --samples <numsamples>
              Acquire <numsamples> samples, then quit.

              You can optionally follow the number by k, m, or g to specify the number of samples
              in kilosamples, megasamples, or gigasamples, respectively.

              For example, --samples 3m will acquire 3000000 samples.

       --frames <numframes>
              Acquire <numframes> frames, then quit.

       --continuous
              Sample continuously until stopped. Not all devices support this.

       --get <variable>
              Get the value of <variable> from the  specified  device  and  print  it.   Multiple
              variable  names  can be specified and get separated by colon.  The list of variable
              names optionally can be preceeded by channel_group=<name> which would override  the
              --channel-group specification.  Multiple --get occurances are supported in a single
              sigrok-cli invocation.

               $ sigrok-cli -d demo --get samplerate:averaging --get channel_group=Logic:pattern

       --set  Set one or more variables specified with the --config  option,  without  doing  any
              acquisition.

EXAMPLES

       In  order  to  get exactly 100 samples from the connected fx2lafw-supported logic analyzer
       hardware, run the following command:

         sigrok-cli --driver fx2lafw --samples 100

       If you want to sample data for 3 seconds (3000 ms), use:

         sigrok-cli --driver fx2lafw --time 3000

       Alternatively, you can also use:

         sigrok-cli --driver fx2lafw --time 3s

       To capture data from the first 4 channels using the Openbench Logic Sniffer lasting  100ms
       at 10 MHz starting at the trigger condition
              0:high, 1:rising, 2:low, 3:high, use:

       sigrok-cli --driver ols:conn=/dev/ttyACM0 --config samplerate=10m \
              --output-format bits --channels 0-3 --wait-trigger \
              --triggers 0=1,1=r,2=0,3=1 --time 100

       To turn on internal logging on a Lascar EL-USB series device:

       sigrok-cli --driver lascar-el-usb:conn=10c4.0002 \
              --config datalog=on --set

EXIT STATUS

       sigrok-cli exits with 0 on success, 1 on most failures.

SEE ALSO

       pulseview(1)

BUGS

       Please  report  any  bugs via Bugzilla (http://sigrok.org/bugzilla) or on the sigrok-devel
       mailing list (sigrok-devel@lists.souceforge.net).

LICENSE

       sigrok-cli is covered by the GNU General Public License (GPL). Some portions are  licensed
       under the "GPL v2 or later", some under "GPL v3 or later".

AUTHORS

       Please see the individual source code files.

       This  manual  page  was written by Uwe Hermann <uwe@hermann-uwe.de>.  It is licensed under