Provided by: plc-utils-extra_0.0.6+git20211210.358dfcf-2_amd64 bug

NAME

       edru - Qualcomm Atheros Ethernet II Data Read Utility

SYNOPSIS

       edru [options] [>stdout]

DESCRIPTION

       Listen  for  incoming Ethernet II frames and write frame data, less header information, to
       stdout as a binary data stream.  Since frame  data  can  contain  anything,  users  should
       direct  output  to  a file or pipe it through some type of filter to prevent corruption of
       the terminal session.  If all incoming data is known to be ASCII then directing stdout  to
       the console should not cause any problems.

       This  program  can  be used to test remote Atheros UART-enabled powerline devices.  Remote
       device package serial data from their local host as Ethernet II frames and  forwared  them
       over  the  powerline  to  a  specific  destination.   The destination must be the Ethernet
       address of the receiving host.  This program reads such frames, discards the frame headers
       and writes the frame dat on stdout.  Data should appear exactly as sent by the remote hos.

OPTIONS

       -e ethertype
              The  protocol (or ethertype) of interest expressed as a 16-bit hexadecimal integer.
              Prefix "0x" is optional.  This filters out frames having any other ethertype.   The
              default is ETH_P_802_2 as defined in if_ether.h.

       -i interface
              The  host interface used to read frames.  The default is "eth1" because most people
              use "eth0" as their principle network connection; however, if the string  "PLC"  is
              defined  in  the  environment  then  it  will  over-ride  the program default.  Any
              interface specified on the command line will over-ride the default.

       -q     Quiet mode.  This option has no effect at this time.

       -t milliseconds
              Read timeout in milliseconds.  Values range from 0 through UINT_MAX.  This  is  the
              maximum time allowed for a response.  The default is 50 milliseconds.

       -v     Verbose mode.  This option has no effect at this time.

ARGUMENTS

       None.

EXAMPLES

       The  following example monitors host interface eth1 for incoming 802.2 Ethernet frames and
       writes frame data to stdout.  In this case, stdout is the console.  Frame data is written,
       as  it  arrives,  and  forms a single output stream.  Directing output to  the console may
       corrupt your terminal session, forcing you to close the console window  and  open  another
       one.

          # edru -ieth1

       The next example does the same thing but directs output to file test.log.  The output file
       may be inspected using a binary hex editor.  The programs  continues  to  read  and  write
       until interrupted using ctrl-c or ctrl-z.

          # edru -ieth1 > test.log

       The  next  example does the same thing but pipes output into program hexdmp which displays
       data in hexadecimal format.  This prevents terminal session corruptions caused  by  binary
       data.  Programhexdmp may not be provided with the toolkit.

          # edru -ieth1 | hexdmp

SEE ALSO

       amp(1), efsu(1), hpav(1)

CREDITS

        Charles Maier