Provided by: plc-utils-extra_0.0.6+git20211210.358dfcf-2_amd64 bug

NAME

       mdustats - MDU traffic statistics

SYNOPSIS

       mdustats [options] [device] [device] [...]

DESCRIPTION

       Collect  and  display  MDU  traffic  statistics using the Qualcomm Atheros vendor specific
       VS_MDU_TRAFFIC_STATS message.

       This program is part of the Qualcomm Atheros Powerline Toolkit.  See the plc man page  for
       an overview and installation instructions.

OPTIONS

       -c command
              An  integer  indicating  the  type  of  statistics  to  be  collected and reported.
              Permitted values are 0 through 255 decimal but only 4 through 15 are valid at  this
              time.  This option is mandatory because the default value of 0 is invalid.
               4 - retrieve traffic statistics on the slave side
               5 - retrieve traffic statistics (master TX/RX) collected on the master side
               6 - retrieve traffic statistics (slave TX/RX) collected on the master side
               7 - retrieve traffic statistics (master/slave TX/RX) collected on the master side
               8 - clear traffic statistics on the slave side
               9 - clear traffic statistics (master TX/RX) colleted on the master side
               10 - clear traffic statistics (slave TX/RX) collected on the master side
               11 - clear traffic statistics (master/slave TX/RX) collected on the master side
               12 - retrieve then clear traffic statistics collected on the slave side
               13 - retrieve then clear traffic statistics (master TX/RX) collected on the master
              side
               14 - retrieve then clear traffic statistics (slave TX/RX) collected on the  master
              side
               15  - retrieve then clear traffic statistics (master/slave TX/RX) collected on the
              master side

       -s session
              The session identifier used to  associate  request/confirm  message  pairs.   Valid
              identifiers are 0 through 255.  The default is 0.

       -t milliseconds
              Read  timeout  in milliseconds.  Values range from 0 through UINT_MAX.  This is the
              maximum time allowed for a response.  The default  is  shown  in  brackets  on  the
              program menu.

       -u unit
              The slave unit number.  This is the same as the slave Terminal Equipment Identifier
              or TEI.  Valid unit numbers are 0 through 255.  Unit 0 is the default.  This option
              is ignored when option -c specified any of the "slave side" commands 4, 8 or 12.

       -v     Print additional information on stdout.

       -x     Cause  the  program to exit on the first error instead of continuing with remaining
              iterations, operations or devices.  Normally, the program reports errors and  moves
              on to the next operation, iteration or device depending on the command line.

       -?,--help
              Print  program  help  summary  on  stdout.  This option takes precedence over other
              options on the command line.

       -?,--version
              Print program version information on stdout.  This  option  takes  precedence  over
              other  options  on  the command line.  Use this option when sending screen dumps to
              Atheros Technical Support so that they know exactly  which  version  of  the  Linux
              Toolkit you are using.

ARGUMENTS

       device The  Ethernet hardware address of some powerline device.  More than one address may
              be specified on the command line.  If more  than  one  address  is  specified  then
              operations are performed on each device in turn.  The default address is local.  as
              explained in the DEVICES section.

DEVICES

       Powerline devices use Ethernet hardware, or Media Access Control (MAC), addresses.  Device
       addresses  are expressed as 12 hexadecimal digits (0123456789ABCDEFabcdef) in upper, lower
       or mixed case.  Individual octets may be separated by colons, for  clarity,  but  not  all
       octets  need  to  be  seperated.   For  example,  "00b052000001",  "00:b0:52:00:00:01" and
       "00b052:000001" are valid and equivalent.

       These symbolic addresses are recognized by this program and may be  used  instead  of  the
       actual address value.

       all    Equivalent to "broadcast", described next.

       broadcast
              A  synonym  for  the  standard  Ethernet broadcast address, FF:FF:FF:FF:FF:FF.  All
              devices, whether local, remote or foreign will respond to this address.

       local  A synonym for the Qualcomm Atheros vendor specific Local Management Address  (LMA),
              00:B0:52:00:00:01.   All  local  Atheros  devices  will  recognize this address but
              remote and foreign devices will not.  A remote device is any device at the far  end
              of  a  powerline  connection.   A  foreign device is any device not manufactured by
              Atheros.

REFERENCES

       See  the  Qualcomm  Atheros  Powerline  Firmware  Technical  Reference  Manual  for   more
       information about MDU powerline configuration and the VS_MDU_TRAFFIC_STATS message type.

DISCLAIMER

       Atheros   HomePlug  AV  Vendor  Specific  Management  Message  structure  and  content  is
       proprietary to Qualcomm Atheros, Ocala FL USA.  Consequently, public information  may  not
       be  available.  Qualcomm Atheros reserves the right to modify message structure or content
       in future firmware releases without any obligation to notify or compensate users  of  this
       program.

EXAMPLES

       The  following  example  collects and displays MDU traffic statistics on the slave side of
       the local device because option -c is 4.  The local device is implicit because  no  device
       is specified on the command line.

          # mdustats -c 4

       The  next  example  collects and displays MDU traffic statistics for slave 2 on the master
       side of device 00:b0:52:9F:E0:14 because option -c is 5 and option -s is  2.   The  master
       device is explicit in this example.

          # mdustats -c 5 -u 2 00b0529FE014

SEE ALSO

       plc(1), int6kstat(1), sada(1)

CREDITS

        Charles Maier