Provided by: zoneminder_1.36.24+dfsg1-1_amd64 bug

NAME

       zoneminder - ZoneMinder Documentation

USER GUIDE

   Introduction
       Welcome to ZoneMinder, the all-in-one security camera solution for Linux with GPL License.

       Commercial  “security  systems”  are  often  designed  as  a monitoring system with little
       attention to recording quality. In such a system, locating and  exporting  relevant  video
       can  be  challenging  and  often  requires  extensive  human  intervention. ZoneMinder was
       designed to provide the best  possible  record  quality  while  allowing  easy  searching,
       filtering and exporting of security footage.

       ZoneMinder  is  designed around a series of independent components that only function when
       necessary, limiting any wasted resource and maximising the efficiency of your machine.  An
       outdated Pentium II PC can have multiple recording devices connected to it, and it is able
       to track one camera per device at up to 25 frames per second, which drops by approximately
       half  for each additional camera on the same device. Additional cameras on devices that do
       not interact with other devices can maintain the 25  frame  rate  per  second.  Monitoring
       several  cameras  will not overload the CPU as frame processing is designed to synchronise
       with capture.

       A fast video interface core, a user-friendly and comprehensive  PHP  based  web  interface
       allows  ZoneMinder  to be efficient, friendly and most importantly useful. You can control
       and monitor your cameras from home, at work, on the road, or a web-enabled cell phone.  It
       supports  variable  web  capabilities based on available bandwidth. The web interface also
       allows you to view events that your cameras have captured, which can be archived, reviewed
       or  deleted.  The  web  application directly interacts with the core daemons ensuring full
       co-operation at all times. ZoneMinder can also be installed as a system service to  reboot
       a system remotely.

       The core of ZoneMinder is the capture and analysis of images and a highly configurable set
       of parameters that eliminate false positives whilst ensuring minimum loss of footage.  For
       example,  you  can  define  a  set  of  ‘zones’ for each camera of varying sensitivity and
       functionality. This eliminates zones that you don’t wish to track  or  define  areas  that
       will alarm if various thresholds are exceeded in conjunction with other zones.

       ZoneMinder  is free under GPL License, but if you do find it useful, then please feel free
       to visit https://zoneminder.com/donate/ and help us fund our future improvements.

   Components
       ZoneMinder is not a single monolithic application but is formed from  several  components.
       These  components  primarily  include executable compiled binaries which do the main video
       processing work, perl scripts which usually perform helper and/or external interface tasks
       and php web scripts which are used for the web interface.

   System Overview
       Depicted  below  is  a  high  level  diagram  of the ZoneMinder system with key components
       [image]

       A brief description of each of the principle components follows.

   Binaries
       zmc    This is the ZoneMinder Capture daemon. This binary’s job  is  to  sit  on  a  video
              device and suck frames off it as fast as possible, this should  run at more or less
              constant speed.

       zma    This is the ZoneMinder Analysis daemon. This is the component that goes through the
              captured  frames and checks them for motion which might generate an alarm or event.
              It generally keeps up with the Capture daemon but if very busy may skip some frames
              to prevent it falling behind.

       zms    This  is  the  ZoneMinder Streaming server. The web interface connects with this to
              get real-time or historical streamed images. It  runs  only  when  a  live  monitor
              stream or event stream is actually being viewed and dies when the event finishes or
              the associate web page is closed. If  you  find  you  have  several  zms  processes
              running  when nothing is being viewed then it is likely you need a patch for apache
              (see the Troubleshooting section). A  non-parsed  header  version  of  zms,  called
              nph-zms,  is  also  installed  and may be used instead depending on your web server
              configuration.

       zmu    This is the ZoneMinder Utility. It’s basically a handy command  line  interface  to
              several useful functions. It’s not really meant to be used by anyone except the web
              page (there’s only limited ‘help’ in it so far) but can be if necessary, especially
              for debugging video problems.

   PHP
       As  well as this there are the web PHP files in the web directory. Currently these consist
       of a single skin with Classic and Flat styles.

       Classic
              Original ZoneMinder skin

       Flat   An updated version of Classic skin, retaining the same layout with  a  more  modern
              style. Originally a skin this is now just a CSS style.

   Perl
       Finally  some  perl  scripts  in  the  scripts  directory.  These  scripts  all  have some
       configuration at the top of the files which should be viewed and amended if necessary  and
       are as follows.

       zmpkg.pl
              This  is  the  ZoneMinder Package Control script. This is used by the web interface
              and service scripts to control the execution of the system as a whole.

       zmdc.pl
              This is the ZoneMinder Daemon Control script. This is used by the web interface and
              the  zmpkg.pl  script  to  control  and  maintain  the execution of the capture and
              analysis daemons, amongst others. You should not need to run this script  yourself,
              although you can use it to start/top individual ZM processes.

       zmfilter.pl
              This script controls the execution of saved filters and will be started and stopped
              by the web interface based on whether there are filters that have been  defined  to
              be  autonomous(background).  This  script  is  also  responsible  for the automatic
              uploading of events to a 3rd party server.  Prior to 1.32 there was one zmfilter.pl
              process.  In 1.32 onwards we start a zmfilter.pl process for each background filter
              so that the processing time of one filter doesn’t delay the processing  of  another
              filter.

       zmaudit.pl
              This script is used to check the consistency of the event file system and database.
              It can delete orphaned events, i.e. ones that appear in one location  and  not  the
              other as well as checking that all the various event related tables are in line. It
              can be run interactively or in batch mode either from the command line  or  a  cron
              job or similar. In the zmconfig.pl there is an option to specify fast event deletes
              where the web interface only deletes the event entry from the database  itself.  If
              this  is  set  then it is this script that tidies up the rest.  We do not recommend
              fast event  deletion  and  we  do  not  recommend  having  zmaudit.pl  run  in  the
              background.   It  is  a  very  ram  cpu  and  disk io intensive program, constantly
              scanning every event.  Please run it manually or from a cron  job  on  weekends  or
              something.

       zmwatch.pl
              This  is  a simple script purely designed to keep an eye on the capture daemons and
              restart them if they lockup. It has been known  for  sync  problems  in  the  video
              drivers to cause this so this script makes sure that nothing important gets missed.

       zmupdate.pl
              Currently  this  script  is  responsible  for  checking  whether  a  new version of
              ZoneMinder is available and other miscellaneous actions  related  to  upgrades  and
              migrations.  It  is also intended to be a ‘one stop shop’ for any upgrades and will
              execute everything necessary to update your installation to a new version.

       zmvideo.pl
              This script is used from the web interface  to  generate  video  files  in  various
              formats  in  a  common  way.  You  can also use it from the command line in certain
              circumstances but this is not usually necessary.

       zmx10.pl
              This is an optional script that can be  used  to  initiate  and  monitor  X10  Home
              Automation style events and interface with an alarm system either by the generation
              of X10 signals on ZoneMinder events or  by  initiating  ZoneMinder  monitoring  and
              capture on receipt of X10 signals from elsewhere, for instance the triggering of an
              X10 PIR. For example I have several cameras that don’t do motion detection until  I
              arm  my  alarm  system  whereupon  they switch to active mode when an X10 signal is
              generated by the alarm system and received by ZoneMinder.

       zmtrigger.pl
              This is an optional script that is a more generic solution to  external  triggering
              of  alarms.  It  can  handle  external connections via either internet socket, unix
              socket or file/device interfaces. You  can  either  use  it  ‘as  is’  if  you  can
              interface  with  the  existing  format,  or  override  connections  and channels to
              customise it to your needs. The format of  triggers  used  by  zmtrigger.pl  is  as
              follows “<id>|<action>|<score>|<cause>|<text>|<showtext>” where

              • ‘id’ is the id number or name of the ZM monitor.

              • ‘action’  is ‘on’, ‘off’, ‘cancel’ or ‘show’ where ‘on’ forces an alarm condition
                on, ‘off’ forces an alarm condition off and ‘cancel’ negates the previous ‘on’ or
                ‘off’.  The ‘show’ action merely updates some auxiliary text which can optionally
                be displayed in the images captured by the monitor. Ordinarily you would use ‘on’
                and  ‘cancel’,  ‘off’  would  tend  to  be  used to suppress motion based events.
                Additionally ‘on’ and ‘off’ can take an additional time offset, e.g. on+20  which
                automatically ‘cancel’s the previous action after that number of seconds.

              • ‘score’ is the score given to the alarm, usually to indicate it’s importance. For
                ‘on’ triggers it should be non-zero, otherwise it should be zero.

              • ‘cause’ is a 32 char max string indicating the reason for, or source of the alarm
                e.g. ‘Relay 1 open’. This is saved in the ‘Cause’ field of the event. Ignored for
                ‘off’ or ‘cancel’ messages.

              • ‘text’ is  a  256  char  max  additional  info  field,  which  is  saved  in  the
                ‘Description’ field of an event. Ignored for ‘off’ or ‘cancel’ messages.

              • ‘showtext’  is up to 32 characters of text that can be displayed in the timestamp
                that is added to images. The ‘show’  action  is  designed  to  update  this  text
                without  affecting  alarms  but  the  text is updated, if present, for any of the
                actions. This is designed to  allow  external  input  to  appear  on  the  images
                captured, for instance temperature or personnel identity etc.

              Note that multiple messages can be sent at once and should be LF or CRLF delimited.
              This script is not necessarily intended to be a solution in itself, but is intended
              to  be  used  as  ‘glue’  to  help ZoneMinder interface with other systems. It will
              almost certainly require some customisation before you can make any use of  it.  If
              all  you  want  to  do  is  generate  alarms  from  external sources then using the
              ZoneMinder::SharedMem perl module is likely to be easier.

       zmcamtool.pl
              This optional script is new for the upcoming 1.27  release  of  ZoneMinder.  It  is
              intended  to make it easy to do the following: bring in new ptz controls and camera
              presets, convert existing monitors into presets, and export custom ptz controls and
              presets.  For  the  initial  release, this script is not integrated into the UI and
              must be called from the command line.  Type ‘’zmcamtool.pl –help’’ from the command
              line to get an explanation of the different arguments one can pass to the script.

       zmcontrol-*.pl
              These are a set of example scripts which can be used to control Pan/Tilt/Zoom class
              cameras. Each script converts a set of standard parameters used for camera  control
              into  the  actual  protocol  commands sent to the camera. If you are using a camera
              control protocol that is not in the shipped list then you will  have  to  create  a
              similar  script  though  it  can be created entirely separately from ZoneMinder and
              does not need to named as these scripts are.  Although  the  scripts  are  used  to
              action commands originated from the web interface they can also be used directly or
              from other programs or scripts, for instance  to  implement  periodic  scanning  to
              different presets.

       zmtrack.pl
              This  script  is  used  to  manage  the experimental motion tracking feature. It is
              responsible for detecting that an alarm is taking place and moving  the  camera  to
              point  to  the  alarmed  location,  and then subsequently returning it to a defined
              standby location. As well as  moving  the  camera  it  also  controls  when  motion
              detection  is suspended and restored so that the action of the camera tracking does
              not trigger endless further alarms which are not justified.

       zm     This is the (optional) ZoneMinder init script, see below for details.

       zmeventnotification.pl
              This is an optional 3rd  party  real  time  event  notification  server  that  also
              provides  push  notifications  for  zmNinja  as  well  as  machine learning powered
              object/face-detection. Please see Event Notification Server Documentation for  more
              details  (Note that the machine learning components are optional, and are developed
              in Python3)

       Finally, there are also a number of ZoneMinder perl modules included. These  are  used  by
       the  scripts  above,  but  can  also  be  used  by  your  own  or  3rd party scripts. Full
       documentation for most modules is available in ‘pod’ form via ‘perldoc’  but  the  general
       purpose of each module is as follows.

       ZoneMinder.pm
              This  is  a general ZoneMinder container module. It includes the Base.pm, Config.pm
              Debug.pm, Database.pm, and SharedMem.pm modules described below.  It  also  exports
              all  of  their  symbols  by default. If you use the other modules directly you have
              request which symbol tags to import.

       ZoneMinder/Base.pm
              This is the base ZoneMinder perl module. It  contains  only  simple  data  such  as
              version information. It is included by all other ZoneMinder perl modules

       ZoneMinder/Config.pm
              This module imports the ZoneMinder configuration from the database.

       ZoneMinder/Debug.pm
              This  module  contains  the defined Debug and Error functions etc, that are used by
              scripts to produce diagnostic information in a standard format.

       ZoneMinder/Database.pm
              This module contains database access definitions and functions. Currently not a lot
              is in this module but it is included as a placeholder for future development.

       ZoneMinder/Event.pm
              This module contains functions to load, manipulate, delete, copy, move events.

       ZoneMinder/Filter.pm
              This module contains functions to load, execute etc filters.

       ZoneMinder/SharedMem.pm
              This  module contains standard shared memory access functions. These can be used to
              access the current state of monitors  etc  as  well  as  issuing  commands  to  the
              monitors to switch things on and off. This module effectively provides a ZoneMinder
              API.

       ZoneMinder/ConfigAdmin.pm
              This module is a  specialised  module  that  contains  the  definition,  and  other
              information, about the various configuration options. It is not intended for use by
              3rd parties.

       ZoneMinder/Control/*.pm
              These modules contain implementations of the various PTZ protocols.

       ZoneMinder/Trigger/*.pm
              These modules contain definitions of trigger channels and connections used  by  the
              zmtrigger.pl script. Although they can be used ‘as is’, they are really intended as
              examples  that  can  be  customised  or  specialised  for   different   interfaces.
              Contributed  modules  for new channels or connections will be welcomed and included
              in future versions of ZoneMinder.

   Getting Started
       After installation of Zoneminder you should  now  be  able  to  load  the  ZoneMinder  web
       frontend.  By  default this will be with the Classic skin, below is an example of the page
       you should now see.  [image]

   Setting Timezone
       Previous versions of ZoneMinder required the user to set up Timezone correctly in php.ini.
       This  is  no longer the case. Starting 1.34, ZoneMinder allows you to specify the TimeZone
       in the UI. Please make sure it is set  up  correctly.  The  Timezone  can  be  changed  by
       selecting Options->System->Timezone [image]

   Enabling Authentication
       We  strongly recommend enabling authentication right away. There are some situations where
       certain users don't enable authentication, such as instances where the server is in a  LAN
       not  directly  exposed  to  the Internet, and is only accessible via VPN etc., but in most
       cases, authentication should be enabled. So let's do that right away.

       • Click on the Options link on the top bar of the web interface

       • You will now be presented with a sidebar full of options. Click on the "System" link
       [image]

       • The relevant portions to change are marked in red above

       • Enable OPT_USE_AUTH - this automatically switches to authentication mode with a  default
         user (more on that later)

       • Select  a  random  string for AUTH_HASH_SECRET - this is used to make the authentication
         logic more secure, so please generate your own string and make sure it  is  sufficiently
         randomized  and  long.  Note  that  if  you  plan to use APIs with ZoneMinder (needed by
         zmNinja/other apps), it is mandatory that you have this field populated

       • The other options highlighed above should already be set, but if not, please  make  sure
         they are

       • Note that if you are planning to use zmNinja and plan to use ZM authentication, you must
         also:

         • set AUTH_RELAY to hashed

         • Enable AUTH_HASH_LOGINS

       • Click on Save at the bottom and that's it! The next time you refresh that page, you will
         now be presented with a login screen. Job well done!
       [image]

       NOTE:
          The default login/password is "admin/admin"

   Understanding the Web Console
       Before  we  proceed,  lets  spend a few minutes understanding the key functions of the web
       console.  For the sake of illustration,  we  are  going  to  use  a  populated  zoneminder
       configuration with several monitors and events.  [image]

       This  screen  is  called  the  "console"  screen in ZoneMinder and shows a summary of your
       monitors, associated events and more information.

       • A: The options menu lets you configure many aspects of ZoneMinder. Refer to Options.

       • B: This brings up a color coded log window that shows various system and component level
         logs. This window is useful if you are trying to diagnose issues. Refer to Logging.

       • C:  ZoneMinder allows you to group monitors for logical separation. This option lets you
         create new groups, associate monitors to them and edit/delete existing groups.

       • D: Filters are a powerful mechanism to perform actions when certain conditions are  met.
         ZoneMinder comes with some preset filters that keep a tab of disk space and others. Many
         users create their own filters for  more  advanced  actions  like  sending  emails  when
         certain events occur and more. Refer to Filtering Events.

       • E: The Cycle option allows you to rotate between live views of each configured monitor.

       • F: The Montage option shows a collage of your monitors. You can customize them including
         moving them around.

       • G: Montage Review allows you to simultaneously view past events for different  monitors.
         Note  that this is a very resource intensive page and its performance will vary based on
         your system capabilities.

       • H: Audit Events Report is more of a power user feature. This option looks for  recording
         gaps in events and recording issues in mp4 files.

       • I: This is the user you are currently logged in as.

       • J:  ZoneMinder  allows you to maintain "run states". If you click on the "Running" text,
         ZoneMinder brings up a popup that allows you to define additional "states" (referred  to
         as  runstates).  A  runstate  is  essentially  a snapshot that records the state of each
         monitor and you can switch between states easily. For example,  you  might  have  a  run
         state  defined  that  switches  all  monitors  to  "monitor"  mode in which they are not
         recording anything while another state that sets some of the monitors to  "modect".  Why
         would  you  want  this? A great example is to disable recording when you are at home and
         enable when you are away, based on time of day or other triggers. You can switch  states
         by  selecting  an  appropriate state manually, or do it automatically via cron jobs, for
         example. An example of using cron to automatically  switch is provided in the FAQ.  More
         esoteric examples of switching run states based on phone location can be found here.

       Here  is  an example of multiple run states that I've defined. Each one of these runstates
       changes the mode of specific monitors depending on time of day and other  conditions.  Use
       your imagination to decide which conditions require state changes.  [image]

       • K: This line shows you system health information

       • L:  This  defines  how  Zoneminder will record events. There are various modes. In brief
         Modect == record if a motion is detected,Record = always record 24x7,  Mocord  =  always
         record PLUS detect motion,  Monitor = just provide a live view but don't record anytime,
         Nodect = Don't record till an external entity via zmtrigger tells Zoneminder to (this is
         advanced usage).

       • M:  This  is  the  "source"  column that tells you the type of the camera - if its an IP
         camera, a USB camera or more. In this example, they are all IP cameras. Green means  the
         monitor is running. Red  means there is something wrong with that camera.

       • N:  This  is the core of ZoneMinder - recording events. It gives you a count of how many
         events were recorded over the hour, day, week, month.

       • O: These are the "Zones". Zones are areas within the camera that you mark as  'hotspots'
         for  motion  detection. Simply put, when you first configure your monitors (cameras), by
         default Zoneminder uses the entire field of view of the camera to detect motion. You may
         not  want  this.  You  may  want to create "zones" specifically for detecting motion and
         ignore others. For example, lets consider a room with a fan that spins. You surely don't
         want  to consider the fan moving continuously a reason for triggering a record? Probably
         not - in that case, you'd leave the fan out while making your zones.

       • P: This is a "visual filter" which lets you 'filter' the console display based  on  text
         you  enter.  While  this may not be particularly useful for small systems, ZoneMinder is
         also used in mega-installations will well over 200+ cameras and this visual filter helps
         reduce the monitors you are seeing at one time.

   Adding Monitors
       Now  that  we  have  a  basic understanding of the web console, lets go about adding a new
       camera (monitor). For this example, lets assume we have an IP camera that streams RTSP  at
       LAN IP address 192.168.1.33.

   Note
       This  is  meant  to  be a simple example. For a more detailed explanation of other options
       available when creating a monitor, please see Defining Monitors

       The first thing we will need to know is how to access that camera's video feed.  You  will
       need to consult your camera's manual or check their forum. Zoneminder community users also
       have a frequently updated list right here that lists information about  many  cameras.  If
       you  don't find your list there and can't seem to find it elsewhere, feel free to register
       and ask in the user forums.

       The camera we are using as an example here is a Foscam 9831W  which  is  a  1280x960  RTSP
       camera, and the URL to access it's feed is username:password@IPADDRESS:PORT/videoMain

       Let's get started:

       Click on the "Add" button below: [image]

       This brings up the new monitor window: [image]

       • We've  given it a name of 'Garage', because, well, its better than Monitor-1 and this is
         my Garage camera.

       • There are various source types. As a brief introduction you'd want  to  use  'Local'  if
         your  camera  is physically attached to your ZM server (like a USB camera, for example),
         and one of 'Remote', 'FFMpeg', 'Libvlc' or 'cURL' for a remote camera (not  necessarily,
         but usually). For this example, let's go with 'FFMpeg'.

       NOTE:
          As  a   thumb  rule,  if  you have a camera accessible via IP and it does HTTP or RTSP,
          start with FFMpeg first and libvlc if it doesn't work (Defining Monitors  covers  other
          modes  in  more  details).  If you are wondering what 'File' does, well, ZoneMinder was
          built with compatibility in mind. Take a look at this post  to see how file can be used
          for leisure reading.

       • In this example, the Function is 'Modect', which means it will start recording if motion
         is detected on that camera feed. The parameters for what constitutes motion detected  is
         specific in Defining Zones

       • In  Analysis  FPS,  we've  put in 5FPS here. Note that you should not put an FPS that is
         greater than the camera FPS. In my case, 5FPS is sufficient for my needs

       NOTE:
          Leave Maximum FPS and Alarm Maximum FPS empty if you are configuring an IP  camera.  In
          older  versions  of ZoneMinder, you were encouraged to put a value here, but that is no
          longer recommended. Infact, if you see your feed going much slower  than  the  feed  is
          supposed  to go, or you get a lot of buffering/display issues, make sure this is empty.
          If you need to control camera FPS, please do it directly on the camera (via its own web
          interface, for example)

       • We are done for the General tab. Let's move to the next tab
       [image]

       • Let's select a protocol of RTSP and a remote method of RTP/RTSP (this is an RTSP camera)

       • Note  that  starting  ZM  1.34, GPUs are supported. In my case, I have an NVIDIA GeForce
         GTX1050i. These cuda and cuvid parameters are what my system supports to use the  NVIDIA
         hardware  decoder  and  GPU  resources.  If  you  don't have a GPU, or don't know how to
         configure your ffmpeg to support it, leave it empty for now. In future, we  will  add  a
         section on how to set up a GPU

       NOTE:  It  is  entirely  possible  that  cuda  and  cuvid  don't work for you and you need
       different values. Isaac uses cuda in DecoderHWAccelName  and  leaves  DecoderHWAccelDevice
       empty. Try that too.

   Todo
       add GPU docs

       That's  pretty  much it. Click on Save. We are not going to explore the other tabs in this
       simple guide.

       You now have a configured monitor: [image]

       And then, finally, to see if everything works, if you click on the garage monitor you just
       added,  you should be able to see its live feed. If you don't, inspect your webserver logs
       and your ZoneMinder logs to see what is going on.

   Switching to another theme
   Todo
       Fix theme text after I clearly understand that System->CSS is doing

       When you first install ZoneMinder, you see is what is called a "classic" skin.  Zoneminder
       has  a host of configuration options that you can customize over time. This guide is meant
       to get you started the easiest possible way, so we will  not  go  into  all  the  details.
       However,  it  is worthwhile to note that Zoneminder also has a 'flat' theme that depending
       on your preferences may look more modern. So let's use that as an example  of  introducing
       you to the Options menu

       • Click on the Options link on the top right of the web interface in the image above

       • This  will bring you to the options window as shown below. Click on the "System" tab and
         then select the "flat" option for CSS_DEFAULT as shown below
       [image]

       • Click Save at the bottom

       Now, switch to the "Display" tab and also select "Flat" there like so: [image]

       Your screen will now look like this:

       Congratulations! You now have a modern looking interface.  [image]

   Conclusion
       This was a quick 'Getting Started' guide where you were introduced to the very  basics  of
       how  to  add  a  monitor (camera). We've skipped many details to keep this concise. Please
       refer to Defining Monitors for many other customization details.

   Defining Monitors
       To use ZoneMinder properly you need to define at least one Monitor. Essentially, a monitor
       is  associated  with  a  camera and can continually check it for motion detection and such
       like.

       You can access the monitor window by clicking on the  “Add  New  Monitor”  button,  or  by
       clicking on the “Source” column of a predefined monitor.  [image]

       There  are  a  small  number of camera setups that ZoneMinder knows about and which can be
       accessed by clicking on the ‘Presets’ link. Selecting one of the presets will fill in  the
       monitor  configuration with appropriate values but you will still need to enter others and
       confirm the preset settings. Here is an example of the presets window: [image]

       The options are divided into a set of tabs to make it easier to edit. You do not  have  to
       ‘save’  to  change  to  different tab so you can make all the changes you require and then
       click ‘Save’ at the end. The individual options are explained  in  a  little  more  detail
       below,

   Monitor Tab
       Name   The  name  for  your  monitor.  This  should  be made up of alphanumeric characters
              (a-z,A-Z,0-9) and hyphen (-) and underscore(_) only. Whitespace is not allowed.

       Server Multi-Server implementation  allows  the  ability  to  define  multiple  ZoneMinder
              servers  sharing a single database. When servers are configured this setting allows
              you nominate the server for each monitor.

       Source Type
              This determines whether the camera is a local one attached to a physical  video  or
              USB  port  on  your  machine,  a  remote  network camera or an image source that is
              represented by a file  (for  instance  periodically  downloaded  from  a  alternate
              location).  Choosing one or the other affects which set of options are shown in the
              Source tab.

       Function
              This essentially defines what the  monitor  is  doing.  This  can  be  one  of  the
              following;

                 • None  –  The monitor is currently disabled. No streams can be viewed or events
                   generated. Nothing is recorded.

                 • Monitor – The monitor is only available for live streaming. No image  analysis
                   is  done  so  no  alarms  or  events  will  be  generated, and nothing will be
                   recorded.

                 • Modect – or MOtion DEteCTtion. All captured images will be analysed and events
                   generated with recorded video where motion is detected.

                 • Record  –  The monitor will be continuously recorded. Events of a fixed-length
                   will be generated regardless of motion, analogous to a conventional time-lapse
                   video recorder. No motion detection takes place in this mode.

                 • Mocord  –  The  monitor  will  be continuously recorded, with any motion being
                   highlighted within those events.

                 • Nodect – or No DEteCTtion. This is a special mode designed  to  be  used  with
                   external  triggers.  In  Nodect no motion detection takes place but events are
                   recorded if external triggers require it.

              Generally speaking it is best to choose ‘Monitor’ as an initial setting here.

       Enabled
              The enabled field indicates whether the monitor should be started in an active mode
              or in a more passive state. You will nearly always want to check this box, the only
              exceptions being when you want the camera to be enabled  or  disabled  by  external
              triggers  or scripts. If not enabled then the monitor will not create any events in
              response to motion or any other triggers.

       Linked Monitors
              This field allows you to select other monitors on your system that act as  triggers
              for  this monitor. So if you have a camera covering one aspect of your property you
              can force all cameras to record while that camera detects motion or  other  events.
              You  can  either  directly  enter a comma separated list of monitor ids or click on
              ‘Select’ to choose a selection. Be very careful not to create circular dependencies
              with  this  feature  however  you  will  have infinitely persisting alarms which is
              almost certainly not what you want! To unlink monitors you can ctrl-click.

       Maximum FPS

          WARNING:
              Unless you know what you are doing, please leave this field  empty,  especially  if
              you  are  configuring  a  network camera. More often than not, putting a value here
              adversely affects recording.

          On some occasions you may have one or more cameras capable of high  capture  rates  but
          find  that  you generally do not require this performance at all times and would prefer
          to lighten the load on your server. This  option  permits  you  to  limit  the  maximum
          capture rate to a specified value. This may allow you to have more cameras supported on
          your system by reducing the CPU load or to allocate video  bandwidth  unevenly  between
          cameras  sharing  the same video device. This value is only a rough guide and the lower
          the value you set the less close the actual FPS may approach it  especially  on  shared
          devices  where  it  can be difficult to synchronise two or more different capture rates
          precisely. This option controls the maximum FPS in the circumstance where no  alarm  is
          occurring only.

          This feature is limited and will only work under the following conditions:

          1. Local cameras

          2. Remote (IP) cameras in snapshot or jpeg mode only

          Using  this field for video streams from IP cameras will cause undesirable results when
          the value is equal to or less than the frame rate from the camera. Note that placing  a
          value  higher  than  the camera’s frame rate is allowed and can help prevent cpu spikes
          when communication from the camera is lost.

       Alarm Maximum FPS

          WARNING:
              Unless you know what you are doing, please leave this field  empty,  especially  if
              you  are  configuring  a  network camera. More often than not, putting a value here
              adversely affects recording.

          If you have specified a Maximum FPS it may be that you don’t want  this  limitation  to
          apply  when your monitor is recording motion or other event. This setting allows you to
          override the Maximum FPS value if this circumstance occurs. As  with  the  Maximum  FPS
          setting  leaving  this  blank  implies no limit so if you have set a maximum fps in the
          previous option then when an alarm occurs this limit would be  ignored  and  ZoneMinder
          would  capture  as  fast  as  possible  for the duration of the alarm, returning to the
          limited value after the alarm has concluded. Equally you could set this to the same, or
          higher (or even lower) value than Maximum FPS for more precise control over the capture
          rate in the event of an alarm.

          IMPORTANT: This field is subject to the same limitations  as  the  Maximum  FPS  field.
          Ignoring these limitations will produce undesriable results.

       Reference Image Blend %ge
              Each  analysed  image in ZoneMinder is a composite of previous images and is formed
              by applying the current image as a certain percentage  of  the  previous  reference
              image. Thus, if we entered the value of 10 here, each image’s part in the reference
              image will diminish by a factor of 0.9 each time  round.  So  a  typical  reference
              image  will  be 10% the previous image, 9% the one before that and then 8.1%, 7.2%,
              6.5% and so on of the rest of the way. An image will effectively vanish  around  25
              images later than when it was added. This blend value is what is specified here and
              if higher will make slower progressing events  less  detectable  as  the  reference
              image  would  change  more quickly. Similarly events will be deemed to be over much
              sooner as the reference image adapts to the new  images  more  quickly.  In  signal
              processing  terms  the  higher this value the steeper the event attack and decay of
              the signal. It depends on your particular requirements what the  appropriate  value
              would  be  for  you  but  start  with 10 here and adjust it (usually down) later if
              necessary.

       Triggers
              This small section lets you select which triggers will apply if the  run  mode  has
              been  set to ‘triggered’ above. The most common trigger is X10 and this will appear
              here if you indicated that your system supported it during installation.  Only  X10
              is  supported  as  a  shipped trigger with ZoneMinder at present but it is possible
              that other triggers will become available as  necessary.  You  can  also  just  use
              ‘cron’  jobs  or  other  mechanisms  to  actually  control the camera and keep them
              completely outside of the ZoneMinder settings.  The  zmtrigger.pl  script  is  also
              available to implement custom external triggering.

   Source Tab
   FFmpeg
          This is the recommended source type for most modern ip cameras.

       Source Path
              Use  this  field  to enter the full URL of the stream or file your camera supports.
              This is usually an RTSP url. There are several methods to learn this:

                 • Check the documentation that came with your camera

                 • Look for your camera in  the  hardware  compatibility  list  in  the  hardware
                   compatibility wiki

                 • Try ZoneMinder’s new ONVIF probe feature

                 • Download and install the ONVIF Device Manager onto a Windows machine

                 • Use  Google  to  find  third  party  sites,  such as ispy, which document this
                   information

       Source Colours
              Specify the amount of colours in the captured image. 32 bit is the preferred choice
              here.  Unlike  with  local  cameras  changing this has no controlling effect on the
              remote camera itself so ensure that your  camera  is  actually  capturing  to  this
              palette beforehand.

       Capture Width/Height
              Make  sure  you  enter  here  the  same  values  as they are in the remote camera’s
              internal setting.

       Keep aspect ratio
              As per local devices.

       Orientation
              As per local devices.

   LibVLC
          The fields for the LibVLC source type are configured the same way as the ffmpeg  source
          type.  We  recommend  only  using  this  source type if issues are experienced with the
          ffmpeg source type.

   cURL
   Local
       Device Path/Channel
              Enter the full path to the device file  that  your  camera  is  attached  to,  e.g.
              /dev/video0.  Some  video  devices, e.g. BTTV cards support multiple cameras on one
              device so in this case enter the channel number in the Channel box or leave  it  at
              zero  if  you’re using a USB camera or one with just one channel. Look in Supported
              Hardware section, how to see if your capture card or USB  webcam  is  supported  or
              not, and what extra settings you may have to do, to make it work.

       Device Format
              Enter the video format of the video stream. This is defined in various system files
              (e.g. /usr/include/linux/videodev.h) but the two most common are 0 for  PAL  and  1
              for NTSC.

       Capture Palette
              Finally  for the video part of the configuration enter the colour depth. ZoneMinder
              supports a handful of the most common palettes, so choose one here. If in doubt try
              32  bit  colour  first,  then  24 bit colour, then grey. If none of these work very
              well, and your camera is local, then YUV420P or one of the  others  probably  will.
              There  is  a  slight  performance penalty when using palettes other than 32, 24, or
              grey palettes as an internal conversion is involved. Recent versions of  ZoneMinder
              support  32bit  colour. This capture palette provides a performance boost when used
              on all modern Intel-based processors.

       Capture Width/Height
              The dimensions of the video stream your camera will supply. If your camera supports
              several  just enter the one you’ll want to use for this application, you can always
              change it later. However I would recommend starting with no larger than 320x240  or
              384x288  and  then  perhaps increasing and seeing how performance is affected. This
              size should be adequate in most cases. Some cameras  are  quite  choosy  about  the
              sizes  you  can  use  here  so  unusual  sizes  such  as  197x333 should be avoided
              initially.

       Keep aspect ratio
              When typing in the dimensions of monitors you can click  this  checkbox  to  ensure
              that  the  width stays in the correct ratio to the height, or vice versa. It allows
              height to be calculated automatically from  width  (or  vice  versa)  according  to
              preset  aspect  ratio.  This  is  preset to 4:3 but can be amended globally via the
              Options->Config->ZM_DEFAULT_ASPECT_RATIO setting. Aside from 4:3 which is the usual
              for  network  and  analog  cameras another common setting is 11:9 for CIF (352x288)
              based sources.

       Orientation
              If your camera is mounted upside down or at right angles you can use this field  to
              specify  a  rotation that is applied to the image as it is captured. This incurs an
              additional processing overhead so if possible it is better to mount your camera the
              right  way  round if you can. If you choose one of the rotation options remember to
              switch the height and width fields so that they apply, e.g. if your camera captures
              at  352x288  and  you  choose ‘Rotate Right’ here then set the height to be 352 and
              width to be 288. You can also choose to ‘flip’ the image if  your  camera  provides
              mirrored input.

   Remote
       Remote Protocol
              Choices are currently HTTP and RTSP. Before RTSP became the industry standard, many
              ip cameras streamed directly from their web portal. If you have an ip  camera  that
              does  not  speak RTSP then choose HTTP here. If you camera does speak RTSP then you
              should change your source type to ffmpeg instead of selecting RTSP here. The Remote
              ->  RTSP  method is no longer being maintained and may go away at some point in the
              future.

       Remote Method
              When HTTP is the Remote Protocol, your choices are Simple and Regexp.  Most  should
              choose  Simple.  When  RTSP  is  the Remote Protocol, your choices are RTP/Unicast,
              RTP/Multicast, RTP/RTSP, RTP,RTSP,HTTP. Try each of these to determine which  works
              with your camera. Most cameras will use either RTP/Unicast (UDP) or RTP/RTSP (TCP).

       Remote Host/Port/Path
              Use  these  fields to enter the full URL of the camera. Basically if your camera is
              at http://camserver.home.net:8192/cameras/camera1.jpg then  these  fields  will  be
              camserver.home.net,  8192  and /cameras/camera1.jpg respectively. Leave the port at
              80 if there is no special port required. If you require  authentication  to  access
              your    camera    then    add    this    onto   the   host   name   in   the   form
              <username>:<password>@<hostname>.com. This will usually be 32 or 24 bit colour even
              if  the  image  looks black and white. Look in Supported Hardware > Network Cameras
              section, how to obtain these strings that may apply to your camera.

       Remote Image Colours
              Specify the amount of colours in the captured  image.  Unlike  with  local  cameras
              changing  this has no controlling effect on the remote camera itself so ensure that
              your camera is actually capturing to this palette beforehand.

       Capture Width/Height
              Make sure you enter here the same  values  as  they  are  in  the  remote  camera’s
              internal setting.

       Keep aspect ratio
              As per local devices.

       Orientation
              As per local devices.

       For       an       example       to       setup       a       MPEG-4      camera      see:
       How_to_Setup_an_Axis211A_with_MPEG-4_streaming

   File
       File Path
              Enter the full path to the file to be used as the image source.

       File Colours
              Specify the amount of colours in the image. Usually 32 bit colour.

       Capture Width/Height
              As per local devices.

       Keep aspect ratio
              As per local devices.

       Orientation
              As per local devices.

   WebSite
       This Source Type allows one to configure an arbitrary website as a  non-recordable,  fully
       interactive, monitor in ZoneMinder. Note that sites with self-signed certificates will not
       display until the end user first manually navigates to the site and accpets  the  unsigned
       certificate.  Also  note  that  some sites will set an X-Frame option in the header, which
       discourages their site from being displayed within a frame. ZoneMinder  will  detect  this
       condition  and  present a warning in the log. When this occurs, the end user can choose to
       install a browser plugin or extension to workaround this issue.

       Website URL
              Enter the full http or https url to the desired website.

       Width (pixels)
              Chose a desired width in pixels that gives an acceptable appearance. This may  take
              some expirimentation.

       Height (pixels)
              Chose a desired height in pixels that gives an acceptable appearance. This may take
              some expirimentation.

       Web Site Refresh
              If the website in question has static content, optionally enter a  time  period  in
              seconds for ZoneMinder to refresh the content.

   Storage Tab
       The  storage  section  allows for each monitor to configure if and how video and audio are
       recorded.

       Save JPEGs
              Records video in individual JPEG frames. Storing JPEG frames requires more  storage
              space  than  h264  but  it  allows  one  to view an event anytime while it is being
              recorded.

              • Disabled – video is not recorded as JPEG frames. If  this  setting  is  selected,
                then  “Video  Writer”  should be enabled otherwise there is no video recording at
                all.

              • Frames only – video is recorded in individual JPEG frames.

              • Analysis images only (if available) – video is recorded in individual JPEG frames
                with  an  overlay  of  the  motion detection analysis information. Note that this
                overlay remains permanently visible in the frames.

              • Frames + Analysis images (if available) – video is recorded twice, once as normal
                individual  JPEG  frames  and  once  in  individual  JPEG  frames  with  analysis
                information overlaid.

       Video Writer
              Records video in real video format. It provides  much  better  compression  results
              than saving JPEGs, thus longer video history can be stored.

              • Disabled  –  video  is not recorded in video format. If this setting is selected,
                then “Save JPEGs” should be enabled otherwise there is no video recording at all.

              • X264 Encode – the video or picture frames received from the camera are transcoded
                into  h264  and  stored  as  a  video. This option is useful if the camera cannot
                natively stream h264.

              • H264 Camera Passthrough – this option assumes that the camera is already  sending
                an  h264  stream.  Video  will  be recorded as is, without any post-processing in
                zoneminder. Video characteristics such as bitrate, encoding mode, etc. should  be
                set directly in the camera.

       Recording Audio
              Check  the box labeled “Whether to store the audio stream when saving an event.” in
              order to save audio (if available) when events are recorded.

   Timestamp Tab
       Timestamp Label Format
              This relates to the timestamp that is applied to each frame.  It  is  a  ‘strftime’
              style  string with a few extra tokens. You can add %f to add the decimal hundredths
              of a  second  to  the  frame  timestamp,  so  %H:%M:%S.%f  will  output  time  like
              10:45:37.45.  You  can  also use %N for the name of the monitor and %Qwhich will be
              filled by any of the ‘show text’ detailed in the zmtriggers.pl section.

       Timestamp Label X/Y
              The X and Y values determine where to put the timestamp. A value of  0  for  the  X
              value will put it on the left side of the image and a Y value of 0 will place it at
              the top of the image. To place the timestamp at the bottom of the image use a value
              eight less than the image height.

   Buffers Tab
       Image Buffer Size
              This option determines how many frames are held in the ring buffer at any one time.
              The ring buffer is the storage space where the last ‘n’ images are kept,  ready  to
              be resurrected on an alarm or just kept waiting to be analysed. It can be any value
              you like with a couple of provisos, (see next options). However  it  is  stored  in
              shared  memory  and  making  it  too  large especially for large images with a high
              colour depth can use a lot of memory. A value of no more than 50 is usually ok.  If
              you  find  that  your system will not let you use the value you want it is probably
              because your system has an arbitrary limit on the size of shared memory that may be
              used  even  though  you  may  have  plenty  of free memory available. This limit is
              usually fairly easy to change, see the Troubleshooting section for details.

       Warm-up Frames
              This specifies how many frames the analysis daemon should process but  not  examine
              when  it  starts.  This  allows  it  to generate an accurate reference image from a
              series of images before looking too carefully for any changes. I use a value of  25
              here,  too  high  and  it  will take a long time to start, too low and you will get
              false alarms when the analysis daemon starts up.

       Pre/Post Event Image Buffer
              These options determine how many frames from before and after an  event  should  be
              preserved  with  it.  This  allows  you to view what happened immediately prior and
              subsequent to the event. A value of 10 for both of these will get you  started  but
              if  you  get  a  lot  of short events and would prefer them to run together to form
              fewer longer ones then increase the Post Event buffer size. The pre-event buffer is
              a  true  buffer and should not really exceed half the ring buffer size. However the
              post-event buffer is just a count that is applied to captured frames and so can  be
              managed  more  flexibly.  You should also bear in mind the frame rate of the camera
              when choosing these values. For instance a network camera capturing  at  1FPS  will
              give you 10 seconds before and after each event if you chose 10 here. This may well
              be too much and pad out events more than necessary. However a fast video  card  may
              capture  at 25FPS and you will want to ensure that this setting enables you to view
              a reasonable time frame pre and post event.

       Stream Replay Image Buffer
              The number of frames buffered to allow pausing and rewinding  of  the  stream  when
              live  viewing a monitor. A value of 0 disables the feature.  Frames are buffered to
              ZM_PATH_SWAP. If this path points to a physical drive, a lot of IO will  be  caused
              during live view / montage. If you experience high system load in those situations,
              either disable the feature or use a RAM drive for ZM_PATH_SWAP.

       Alarm Frame Count
              This option allows you to specify how many  consecutive  alarm  frames  must  occur
              before  an  alarm  event  is  generated.  The  usual, and default, value is 1 which
              implies that any alarm frame will cause or participate in an event. You  can  enter
              any value up to 16 here to eliminate bogus events caused perhaps by screen flickers
              or other transients. Values over 3 or 4 are unlikely to be useful  however.  Please
              note  that  if  you have statistics recording enabled then currently statistics are
              not recorded for the first ‘Alarm Frame Count’-1 frames of an event. So if you  set
              this value to 5 then the first 4 frames will be missing statistics whereas the more
              usual value of 1 will ensure that all alarm frames have statistics recorded.

   Control Tab
       Note: This tab and its options will only appear if you have  selected  the  ZM_OPT_CONTROL
       option  to  indicate that your system contains cameras which are able to be controlled via
       Pan/Tilt/Zoom or other mechanisms. See  the  Camera  Control  section  elsewhere  in  this
       document for further details on camera control protocols and methods.

       Controllable
              Check this box to indicate your camera can be controlled.

       Control Type
              Select  the control type that is appropriate for your camera. ZoneMinder ships with
              a small number of predefined control protocols which will works with  some  cameras
              without  modification but which may have to amended to function with others, Choose
              the edit link to create new control types or to edit the existing ones.

       Control Device
              This is the device that is used to control your camera. This  will  normally  be  a
              serial  or similar port. If your camera is a network camera, you will generally not
              need to specify a control device.

       Control Address
              This is the address of your camera. Some control protocols require that each camera
              is  identified by a particular, usually numeric, id. If your camera uses addressing
              then enter the id of your camera here. If your camera is a network camera then  you
              will  usually  need  to  enter  the  hostname  or  IP  address  of it here. This is
              ordinarily the same as that given for the camera itself.

       Auto Stop Timeout
              Some cameras only support a continuous mode of movement. For instance you tell  the
              camera  to  pan right and then when it is aligned correctly you tell it to stop. In
              some cases it is difficult to time this precisely over  a  web  interface  so  this
              option  allows  you  to  specify  an  automatic  timeout  where the command will be
              automatically stopped. So a value of 0.25 here can tell the script to stop moving a
              quarter  of  a  second  after  starting.  This allows a more precise method of fine
              control. If this value is left blank or at zero it will be ignored, if set then  it
              will  be  used  as the timeout however it will only be applied for the lower 25% of
              possible speed ranges. In other words if your camera has a pan speed range of 1  to
              100  then  selecting to move at 26 or over will be assumed to imply that you want a
              larger movement that you can control yourself  and  no  timeout  will  be  applied.
              Selecting motion at lower speeds will be interpreted as requiring finer control and
              the automatic timeout will be invoked.

       Track Motion
              This and the following four options are used with the experimental motion function.
              This  will only work if your camera supports mapped movement modes where a point on
              an image can be mapped to a control command.  This  is  generally  most  common  on
              network  cameras but can be replicated to some degree on other cameras that support
              relative movement modes. See the Camera Control section  for  more  details.  Check
              this box to enable motion tracking.

       Track Delay
              This  is  the  number  of  seconds  to  suspend  motion detection for following any
              movement that the camera may make to track motion.

       Return Location
              If you camera supports a ‘home’ position or presets you can choose which preset the
              camera should return to after tracking motion.

       Return Delay
              This  is  the delay, in seconds, once motion has stopped being detected, before the
              camera returns to any defined return location.

   X10 Tab
       Note: This tab and its options will only appear if you have  indicated  that  your  system
       supports the X10 home automation protocol during initial system configuration.

       X10 Activation String
              The  contents  of  this  field  determine  when a monitor starts and/or stops being
              active when running in ‘Triggered; mode and with X10 triggers. The format  of  this
              string is as follows,

                 • n  :  If  you simply enter a number then the monitor will be activated when an
                   X10 ON signal for that unit code is detected and will be deactivated  when  an
                   OFF signal is detected.

                 • !n  :  This  inverts  the  previous  mode,  e.g.  !5 means that the monitor is
                   activated when an OFF signal for unit code 5 is detected and deactivated by an
                   ON.

                 • n+ : Entering a unit code followed by + means that the monitor is activated on
                   receipt of a ON signal for that unit code but will ignore the OFF  signal  and
                   as  such  will not be deactivated by this instruction. If you prepend a ‘!’ as
                   per the previous definition it similarly inverts the mode, i.e. the ON  signal
                   deactivates the monitor.

                 • n+<seconds> : As per the previous mode except that the monitor will deactivate
                   itself after the given number of seconds.

                 • n- : Entering a unit code followed by - means that the monitor is  deactivated
                   on  receipt  of  a OFF signal for that unit code but will ignore the ON signal
                   and as such will not be activated by this instruction. If you prepend a ‘!’ as
                   per the previous definition it similarly inverts the mode, i.e. the OFF signal
                   activates the monitor.

                 • n-<seconds> : As per the previous mode except that the monitor  will  activate
                   itself after the given number of seconds.

              You  can  also  combine  several  of these expressions to by separating them with a
              comma to create multiple circumstances of activation. However for  now  leave  this
              blank.

       X10 Input Alarm String
              This  has  the  same  format  as  the  previous field but instead of activating the
              monitor with will cause a forced alarm to be generated and an event recorded if the
              monitor  is  Active. The same definition as above applies except that for activated
              read alarmed and for deactivated read unalarmed(!). Again leave this blank for now.

       X10 Output Alarm String
              This X10 string also has the same format as the two above options. However it works
              in  a  slightly  different  way.  Instead of ZoneMinder reacting to X10 events this
              option controls how ZoneMinder emits X10 signals when the current monitor goes into
              or  comes  out  of  the  alarm state. Thus just entering a number will cause the ON
              signal for that unit code to be sent when going into alarm state and the OFF signal
              when  coming out of alarm state. Similarly 7+30 will send the unit code 7 ON signal
              when going into alarm state and the OFF  signal  30  seconds  later  regardless  of
              state.   The  combination  of  the  X10  instruction  allows  ZoneMinder  to  react
              intelligently to, and also assume control of, other devices when necessary. However
              the  indiscriminate  use of the Input Alarm and Output Alarm signals can cause some
              horrendous race conditions such as a light going on in response to an  alarm  which
              then  causes  an alarm itself and so on. Thus some circumspection is required here.
              Leave this blank for now anyway.

   Misc Tab
       Event Prefix
              By default events are named ‘Event-<event id>’, however you are free to rename them
              individually  as  you  wish.  This  option  lets  you  modify the event prefix, the
              ‘Event-‘ part, to be a value of your choice so that events are named differently as
              they  are  generated.  This  allows  you  to name events according to which monitor
              generated them.

       Section Length
              This specifies the length (in seconds) of any fixed length events produced when the
              monitor  function is ‘Record’ or ‘Mocord’. Otherwise it is ignored. This should not
              be so long that events are difficult to navigate nor so short that too many  events
              are generated. A length of between 300 and 900 seconds I recommended.

       Frame Skip
              This  setting also applies only to the ‘Record’ or ‘Mocord’ functions and specifies
              how many frames should be skipped in the recorded events. The  default  setting  of
              zero  results  in every captured frame being saved. Using a value of one would mean
              that one frame is skipped between each saved, two means that two frames are skipped
              between  each  saved  frame  etc. An alternate way of thinking is that one in every
              ‘Frame Skip + 1’ frames is saved. The point of this is to ensure that saved  events
              do  not  take  up  too much space unnecessarily whilst still allowing the camera to
              capture at a fairly high frame rate. The alternate approach is to limit the capture
              frame rate which will obviously affect the rate at which frames are saved.

       FPS Report Interval
              How  often  the  current performance in terms of Frames Per Second is output to the
              system log. Not used in any functional way so set it to maybe 1000 for now. If  you
              watch  /var/log/messages  (normally)  you  will see this value being emitted at the
              frequency you specify both for video capture and processing.

       Default Scale
              If your monitor has been defined with a particularly large or small image size then
              you  can choose a default scale here with which to view the monitor so it is easier
              or more visible from the web interface.

       Web Colour
              Some elements of ZoneMinder now use colours to identify monitors on certain  views.
              You  can  select which colour is used for each monitor here. Any specification that
              is valid for HTML colours is valid here, e.g. ‘red’ or ‘#ff0000’.  A  small  swatch
              next to the input box displays the colour you have chosen.

       Embed EXIF data into image:
              Embeds EXIF data into each jpeg frame

   Todo
       what about mp4s?

   Defining Zones
       The  next  important  thing  to  do  with  a new monitor is set up Zones for it to use. By
       default you’ll already have one generated for you  when  you  created  your  monitor  (the
       default  zone is the full area captured by the monitor) but you might want to modify it or
       add others.

       Click on the Zones column for your monitor and you should see a small popup window  appear
       which  contains  an  image  from your camera overlain with a stippled pattern representing
       your zone. In the default case this will cover the whole image. The colour  of  the  zones
       appearing here is determined by what type they are. The default zone is Active and so will
       be red, Inclusive zones are orange, exclusive zones are purple, preclusive zones are  blue
       and inactive zones are white.

       Beneath  the  zones  image will be a table containing a listing of your zones. Clicking on
       either the relevant bit of the image or on the Id or Name  in  the  table  will  bring  up
       another  window where you can edit the particulars for your Zones. For more information on
       defining or editing a zone, see Defining Zones.

       Zone configuration and tuning are important when running in the motion detection modes  to
       avoid storing, sorting through, or being alerted on uninteresting video data.  Configuring
       a zone involves setting some basic parameters, as well as choosing an alarm  check  method
       and tuning their associated detection parameters.

       The Zone view is split into two main areas, on the left is the options are area and on the
       right is the zone drawing area. A default or new zone will cover the  whole  drawing  area
       and  will  overlay  any  other  zones you already have on there. Unlike the previous zones
       image, the current zone is coloured green, other zones will be orange regardless of  type.
       The smaller the zone, the less processing time it takes to examine it.

   Basic parameters
       Name   Each  Zone  can  be  named  for  reference  purposes.   It  is used for logging and
              debugging.  Choose a name that helps you identify your zones.

       Type   This is one of the more important concepts in  ZoneMinder  and  there  are  six  to
              choose from.

              • Active  Triggers  an  alarm  when motion is detected within it.  This is the zone
                type you’ll use most often, and which will be set for your  default  zone.   Only
                Active and Exclusive zones can trigger an alarm.

              • Inclusive  This  zone  type can be used for any zones that you want to trigger an
                alarm only if at least one other Active zone  has  already  triggered  one.  This
                might  be  for  example  to cover an area of the image like a plant or tree which
                moves a lot and which would trigger lots of alarms. Perhaps  this  is  behind  an
                area  you’d  like  to  monitor  though,  in this case you’d create an active zone
                covering the non-moving parts and an inclusive zone  covering  the  tree  perhaps
                with  less  sensitive detection settings also. If something triggered an alarm in
                the Active zone and also in the Inclusive zone they would both be registered  and
                the  resulting  alarm  would  be  that much bigger than if you had blanked it out
                altogether.

              • Exclusive Triggers an alarm when motion is detected within  it,  as  long  as  no
                alarms  have  already  been  triggered  in  an  Active  zone.   This  is the most
                specialized of the zone types. For instance in the camera covering  my  garden  I
                keep  watch  for a hedgehog that visits most nights and scoffs the food out of my
                cats bowls. By creating a sensitive Exclusive zone in that area I can ensure that
                a  hedgehog  alarm  will only trigger if there is activity in that small area. If
                something much bigger occurs, like someone walking by it will trigger  a  regular
                alarm and not one from the Exclusive zone. Thus I can ensure I get alarms for big
                events and also special small events but not the noise in between.

              • Preclusive This zone type is relatively recent. It is called  a  Preclusive  zone
                because  if  it  is  triggered it actually precludes an alarm being generated for
                that image frame. So motion or other changes that occur in a Preclusive zone will
                have the effect of ensuring that no alarm occurs at all. The application for this
                zone type is primarily as a shortcut for detecting general  large-scale  lighting
                or  other  changes. Generally this may be achieved by limiting the maximum number
                of alarm pixels or other measure in an Active zone. However in  some  cases  that
                zone  may  cover  an  area  where  the  area  of  variable illumination occurs in
                different places as the sun and/or shadows move and it thus may be  difficult  to
                come  up  with  general  values.  Additionally, if the sun comes out rapidly then
                although the initial change may be ignored in this way  as  the  reference  image
                catches  up  an  alarm  may  ultimately  be  triggered  as the image becomes less
                different. Using one or  more  Preclusive  zones  offers  a  different  approach.
                Preclusive  zones are designed to be fairly small, even just a few pixels across,
                with quite low alarm thresholds. They should be situated in areas  of  the  image
                that  are less likely to have motion occur such as high on a wall or in a corner.
                Should a general illumination change occur they would be triggered  at  least  as
                early  as  any Active zones and prevent any other zones from generating an alarm.
                Obviously careful placement is required to ensure that they  do  not  cancel  any
                genuine  alarms  or that they are not so close together that any motion just hops
                from one Preclusive zone to another.  Preclusive zones may also be used to reduce
                processing  time  by  situating  one over an Active zone.  The Preclusive zone is
                processed first; if it is small, and is triggered, the  rest  of  the  zone/image
                will  not  be processed. See Extend Alarm Frame Count below for a way to hold the
                preclusive zone active for an extended period.

              • Inactive Suppresses the detection of motion within it.  This can  be  layered  on
                top of any other zone type, preventing motion within the Inactive zone from being
                effective for any other zone type.  Use inactive zones to cover  areas  in  which
                nothing  notable will ever happen or where you get false alarms that don’t relate
                to what you are trying to monitor.  Inactive zones may be overlaid on other zones
                to blank out areas, and are processed first (with the exception of Privacy zones,
                see below).  As a general practice, you should try and make zones abut each other
                instead of overlapping to avoid repeated duplicate processing of the same area.

              • Privacy  Blackens the pixels within it. This can be used if you want to hide some
                regions in the image if the situation does not allow another solution. This  zone
                type is different to all the others in that it gets processed as soon as possible
                during capture (even before the timestamp gets into the image)  and  not  in  the
                analyzing  process. So if you add, change or delete a Privacy zone, you don’t see
                the changes in the image until the capture process gets restarted. This  will  be
                done automatically, but needs a few seconds.

       Preset The  preset chooser sets sensible default values based on computational needs (fast
              v. best) and sensitivity (low, medium, high.)  It is not required that you select a
              preset,  and  you  can  alter any of the parameters after choosing a preset.  For a
              small number of monitors with ZoneMinder running on modern  equipment,  Best,  high
              sensitivity can be chosen as a good starting point.

              It  is  important to understand that the available presets are intended merely as a
              starting point. Since every camera’s view is unique, they  are  not  guaranteed  to
              work  properly  in  every case. Presets tend to work acceptably for indoor cameras,
              where the objects of interest are relatively close and there typically are  few  or
              no  unwanted  objects  moving  within the cameras view. Presets, on the other hand,
              tend to not work acceptably for  outdoor  cameras,  where  the  field  of  view  is
              typically  much  wider,  objects of interest are farther away, and changing weather
              patterns can cause false triggers. For outdoor  cameras  in  particular,  you  will
              almost  certainly  have  to tune your motion detection zone to get desired results.
              Please refer to this guide to learn how to do this.

       Units

              • Pixels - Selecting this option will allow many of  the  following  values  to  be
                entered (or viewed) in units of pixels.

              • Percentage  -  Selecting this option will allow may of the following values to be
                entered (or viewed) as a percentage.  The sense of the percentage  values  refers
                to  the  area of the zone and not the image as a whole. This makes trying to work
                out necessary sizes rather easier.

       Region points [image]

       The sample region shown to the right shows a region defined  by  6  control  points.   The
       shape of the region causes the check methods to ignore the sidewalk and areas of the porch
       wall that receive changing sunlight; two conditions that are not of interest in this zone.
          A region is a part of the captured image  that  is  of  interest  for  this  zone.   By
          default,  a  region  is configured to cover the whole captured image.  Depending on the
          selected type of this zone, the shape of the region  can  be  adjusted  to  accommodate
          multiple  effects.   This  can  be done by dragging the control points in the reference
          image around, or by altering the coordinates found in the controls below the  reference
          image.   Clicking  on a control point in the reference image highlights the coordinates
          in the table below.  Clicking the + button in a point row adds a control point  between
          this  point  and  the  next;  clicking  the - button removes this control point.  It is
          possible to accidentally place a control point outside of the valid coordinates of  the
          image.  This will prevent the monitor from working properly.  You can make zones almost
          any shape you like; except that zones may not self-intersect (i.e. edges crossing  over
          each other).

       Alarm Colour
              These  parameters  can  be  used to individually colorize the zone overlay pattern.
              Alarms in this zone will be highlighted  in  the  alarm  colour.   This  option  is
              irrelevant for Preclusive and Inactive zones and will be disabled.

       Alarm Check Methods
              There  are  3  Alarm  Check  Methods.   They  are  sequential, and are layered:  In
              AlarmedPixels mode, only the AlarmedPixel analysis is performed.  In FilteredPixels
              mode,  the  AlarmedPixel analysis is performed first, followed by the FilteredPixel
              analysis.  In the Blobs mode, all 3 analysis methods are performed  in  order.   An
              alarm  is  only  triggered if all of the enabled analysis modes are triggered.  For
              performance reasons, as soon as the criteria for one of the analysis modes  is  not
              met, the alarm checking for the frame is complete.  Since the subsequent modes each
              require progressively more computations, it is a good idea to tune  the  parameters
              in each of the activated layers.

              For  reference  purposes,  the Zone Area box shows the area of the entire region of
              interest.  In percent mode, this is 100.  In Pixels mode, this is the  pixel  count
              of  the  region.  All 3 Min/Max Area parameter groups are based on the Zone Area as
              the maximum sensible value, and all 3 are interpreted in the units specified in the
              Units input.

       AlarmedPixels
              Alarmed  pixels  is  the  first  layer  of  analysis,  and  is always enabled.  Its
              recommended that you start with this method and move on to the  subsequent  methods
              once  the  effects  of  the  basic parameters are understood.  In the AlarmedPixels
              mode, 2 parameter categories are available for tuning: Min/Max Pixel Threshold, and
              Min/Max Alarmed Area.

       Min/Max Pixel Threshold (0-255)
              In  the  AlarmedPixel  layer  of  analysis,  each  individual pixel of the image is
              compared to the current reference  image.   Pixels  that  are  different  from  the
              reference  image  are  considered  alarmed  pixels.   However, small aberrations in
              lighting or auto exposure camera adjustments may cause  the  explicit  value  of  a
              pixel  to  vary by small amounts from image to image.  This parameter allows you to
              set the limits of what will be considered a changed pixel.  For  example,  if  your
              camera  points to a blank white wall, and you raise a black colored item into view,
              then the change in any one pixel will be great, indeed, extreme.  If  however,  you
              raise a white piece of paper, then the change in an individual pixel will be less.

              The  minimum pixel threshold setting should be high enough to cause minor lighting,
              imaging, or compression changes to be ignored.  Setting the minimum value too high,
              may allow a white cat to walk undetected across the view of the white wall.  A good
              starting point for the minimum pixel threshold is 40, meaning that  the  difference
              in  pixel value from must be greater than 40.  A good default for the maximum pixel
              threshold is 0 (indicating that all differences above  the  minimum  threshold  are
              considered a change.)

       Min/Max Alarmed Area
              The  count of alarmed pixels (or percentage of alarmed pixels relative to the pixel
              area of the region if in percent mode) is used in this first layer of  analysis  to
              determine  if  an  alarm  is  triggered.   If  the count or percentage is above the
              minimum alarmed area,  but  less  than  the  maximum  alarmed  area,  an  alarm  is
              triggered.   These  settings  depend  on  the  size of the object you are trying to
              capture: a value too low may cause false alarms, while a value too high  might  not
              detect small objects.  A good starting point for both the minimum and maximum are 0
              and 0, indicating that any number of alarmed pixels  (or  any  percentage)  greater
              than 0 will trigger an alarm.  The frame scores from logged events can then be used
              to bring the minimum up to a reasonable value.  An alternative starting  point  for
              the minimum alarmed area (in percent) is 25% of the area that an object of interest
              takes up in the region.  For example, if you  approximate  that  a  subject  moving
              through  the  frame takes up 30% of the frame, then a good starting minimum area is
              about 7.5%.

       FilteredPixels
              Selecting the FilteredPixels  Alarm  Check  Method  adds  an  additional  layer  of
              analysis  to  the  AlarmedPixels check along with 2 additional parameter categories
              for tuning.  This layer works by analyzing the alarmed  pixels  identified  in  the
              first layer.  Alarmed pixels are disregarded, in this and future layers if enabled,
              if they are not in  groups  of  a  minimum  small  square  size.   Primarily,  this
              filtering  removes  isolated  alarmed  pixels  that may be artifacts of the camera,
              lens, or compression.

       Filter Width/Height (pixels)
              This parameter is always  specified  in  Pixels,  even  when  Percentages  are  the
              selected  units.   It specifies the size of the group of pixels surrounding a given
              pixel that must be in alarmed pixels for the  pixel  itself  to  be  considered  an
              alarmed  pixel.  The width and height should always be an odd number.  3 x 3 is the
              default value, and 5 x 5 is also suggested as a sensible alternative.  Avoid  using
              large  numbers  for  the width and height of the filter area.  When using the Blobs
              Alarm Check Method, FilteredPixels can be effectively disabled  by  setting  either
              the width or height to a value less than 1.

       Min/Max Filtered Area
              Applying  the  filtering  analysis results in an area that is less than or equal to
              the alarmed area.  Thus the minimum and maximum filtered area parameters for  alarm
              should  be  equal  to  or less than the corresponding alarm area parameters, or the
              FilteredPixels analysis will never trigger an alarm.  In particular, it  is  useful
              to raise the minimum alarmed area parameter until false events from image artifacts
              disappear, and setting a minimum filtered area parameter less the  minimum  alarmed
              area parameter by enough to capture small events of interest.

       Blobs [image]

       This  image  shows  an  image  with  1 identified blob.  The blob is outlined in the Alarm
       Colour specified above.

       When two or more Filtered areas touch or share a boundary, it is sensible to evaluate  the
       regions  as one contiguous area instead of separate entities.  A Blob is a contiguous area
       made up of multiple filtered areas.  Whereas FilteredPixes is useful for  excluding  parts
       of  the  image  that  are not part of the actual scene, Blob filtering is better suited to
       disregarding areas of the actual scene that are not of interest.
          Selecting the Blobs Alarm Check Method  opens  up  all  of  the  available  parameters.
          Enabling  Blobs  adds  one more layer of analysis to the AlarmedPixel and FilteredPixel
          checks in the determination of a valid alarm along along with  2  additional  parameter
          categories  for  tuning: the size of the blobs, and the number of blobs.  A Blob is not
          necessarily the whole object that may be  of  interest.   In  the  example  image,  the
          subject  is  moving, but only a portion of him is marked as a blob.  This is because as
          the subject moves, many pixels of the image do not  change  in  value  beyond  the  set
          threshold.   A  pixel  that  is representing the subject’s shoulder in one frame may be
          representing his back in the next, however, the value of the pixel remains  nearly  the
          same.

       Min/Max Blob Area
              The blob area parameters control the smallest and largest contiguous areas that are
              to be considered a blob.  A good value for the maximum area is the  default  of  0.
              (There  is  no  upper  bound  for  the size of a contiguous area that will still be
              considered a blob.)

       Min/Max Blobs
              Normally, you would want any positive number of blobs to trigger an event,  so  the
              default  value  of 1 should suffice.  In some circumstances, it may benefit to have
              only one blob NOT trigger an event, in which case,  setting  this  value  to  2  or
              higher  may  serve some special purpose.  A good value for the maximum blobs is the
              default of 0. (There is no upper bound for the number of blobs that will trigger an
              event.   Use the maximum blobs parameter can be used to tune out events that show a
              high number of blobs.

       Overload Frame Ignore Count
              This setting specifies the number  of  frames  to  NOT  raise  an  alarm  after  an
              overload.  In  this  context,  overload  is defined as a detected change too big to
              raise an alarm. Depending on the alarm check method  that  could  be  *  Number  of
              alarmed  pixels  >  Max  Alarmed Area or * Number of filtered pixels > Max Filtered
              Area or * Number of Blobs > Max Blobs The idea is that after a change like a  light
              going on that is considered too big to count as an alarm, it could take a couple of
              frames for things to settle down again.

       Extend Alarm Frame Count
              This field applies to Preclusive Zones only. Placing a value in  this  field  holds
              the  Preclusive  zone  active  for the specified number of frames after the initial
              triggering event. This is useful in cases where a  sudden  change  in  light  level
              triggers the Preclusive zone, but the zone needs to be held active for a few frames
              as the camera itself adjusts to that change in light level.

   Other information
       Refer to this user contributed Zone guide for additional information will illustrations if
       you are new to zones and need more help.

   Viewing Monitors
       ZoneMinder allows you to view a live feed of your configured monitors. One can access this
       view by clicking on the “Name” column of any of the monitors [image]

       Clicking on the name produces a view similar to this: [image]

       The image should be self-explanatory but if it looks like garbage it is possible that  the
       video  configuration  is  wrong  so  look in your system error log and check for or report
       anything unusual. The centre of the window will have a tiny frame  that  just  contains  a
       status;  this  will be ‘Idle’, ‘Alarm’ or ‘Alert’ depending on the function of the Monitor
       and what’s going on in the field of view. Idle means nothing  is  happening,  Alarm  means
       there  is  an alarm in progress and Alert means that an alarm has happened and the monitor
       is ‘cooling down’, if another alarm is generated in this time it will just become part  of
       the same event. These indicators are colour coded in green, red and amber.

       By  default if you have minimised this window or opened other windows in front it will pop
       up to the front if it goes to Alarm state. This behaviour can be turned off  in  ‘options’
       if  required. You can also specify a sound file in the configuration, which will be played
       when an alarm occurs to alert you to the fact if you are not in front  of  your  computer.
       This  should be a short sound of only a couple of seconds ideally. Note that as the status
       is refreshed every few seconds it is possible for this not to alert  you  to  every  event
       that  takes  place,  so you shouldn’t rely on it for this purpose if you expect very brief
       events. Alternatively you can decrease  the  refresh  interval  for  this  window  in  the
       configuration though having too frequent refreshing may impact on performance.

       Below  the  status  is  a  list  of recent events that have occurred, by default this is a
       listing of just the last 10 but clicking on ‘All’ will give you a full list and  ‘Archive’
       will  take  you to the event archive for this monitor, more on this later. Clicking on any
       of the column headings will sort the events appropriately.

       From here you can also delete events if you wish. The events themselves  are  listed  with
       the event id, and event name (which you can change), the time that the event occurred, the
       length of the event including any preamble and postamble  frames,  the  number  of  frames
       comprising  the  event  with  the  number  that  actually contain an alarm in brackets and
       finally a score. This column lists the average score  per  alarm  frame  as  well  as  the
       maximum score that any alarm frame had.

       The  score  is  an arbitrary value that essentially represents the percentage of pixels in
       the zone that are in blobs divided by the square root of the  number  of  blobs  and  then
       divided  by  the  size of the zone. This gives a nominal maximum of 100 for a zone and the
       totals for each zone  are  added  together,  Active  zones  scores  are  added  unchanged,
       Inclusive  zones  are  halved first and Exclusive zones are doubled. In reality values are
       likely to be much less than 100 but it does give a simple  indication  of  how  major  the
       event was.

   Filtering Events
       Filters  allow  you  to  define  complex conditions with associated actions in ZoneMinder.
       Examples could include:

       • Send an email each time a new event occurs for a specific monitor

       • Delete events that are more than 10 days old

       And many more.

       The filter window can be accessed by tapping on the top level filter menu

       You can use the filter window to create your own filters or to modify existing  ones.  You
       can  even  save  your  favourite  filters  to re-use at a future date. Filtering itself is
       fairly simple; you first choose how many expressions you’d like your  filter  to  contain.
       Changing  this  value  will  cause  the window to redraw with a corresponding row for each
       expression. You then select what you want to filter on and how the expressions  relate  by
       choosing  whether  they  are  ‘and’  or  ‘or’ relationships. For filters comprised of many
       expressions you will also get the option to bracket parts of the filter to ensure you  can
       express  it  as  desired.  Then  if  you  like choose how you want your results sorted and
       whether you want to limit the amount of events displayed.

       Here is what the filter window looks like [image]

       • A: This is a dropdown list where you can select pre-defined  filters.  You  will  notice
         that ZoneMinder comes with a PurgeWhenFull filter that is configured to delete events if
         you reach 95% of disk space.

       • B: If you are creating a new filter, you can type in a name for your filter here

       • C: This is where you specify  conditions  that  need  to  match  before  the  filter  is
         executed. You use the “+” and “-” buttons to add/delete conditions

       • D:  This  allows you to perform sorting and limiting operations on the output before you
         take an action

       • E: This is where you specify what needs to happen when the conditions match:

                • Archive all matches: sets the archive field  to  1  in  the  Database  for  the
                  matched events.  Think of ‘archiving’ as grouping them under a special category
                  - you can view archived events later and also make sure archived  events  don’t
                  get deleted, for example

   Todo
       For the “create video” filter, put in more details on how it works, any dependencies etc.

         • Update used disk space: calculates how much disk space is currently taken by the event
           and updates the db record.

         • Create video for all matches: creates a video file of all the events that match

         •

           Create video for all matches: ffmpeg will be used to create a video file (mp4) out  of
           all the stored jpgs if using jpeg storage.

                  • Execute  command  on all matches: Allows you to execute any arbitrary command
                    on the matched events. You can use replacement tokens as subsequent  arguents
                    to  the  command,  the  last argument will be the absolute path to the event,
                    preceded by replacement arguents. eg: /usr/bin/script.sh %MN% will execute as
                    /usr/bin/script.sh  MonitorName  /path/to/event.  Please  note  that urls may
                    contain characters like & that need quoting. So you may need  to  put  quotes
                    around them like /usr/bin/scrupt.sh “%MN%”.

                  • Delete all matches: Deletes all the matched events.

                  • Email  details  of all matches: Sends an email to the configured address with
                    details about the event.

         • Copy all matches: copies the event files to another location, specified in the Copy To
           dropdown.  The other location must be setup in the Storage Tab under options.

         • Message  details  of  all matches: Uses an email to SMS gateway to send an SMS message
           for each match.

         • Move all matches: copies the event files to another location, specified in the Move To
           dropdown.   The  other  location  must  be setup in the Storage Tab under options. The
           files will be delete from the original location.

         • Run filter in background:  When checked, ZoneMinder  will  make  sure  the  filter  is
           checked regularly. For example, if you want to be notified of new events by email, you
           should make sure this is checked. Filters that are configured to run in the background
           have a “*” next to it.

         • Run  filter  concurrently: Allows this filter to run in its own thread thereby letting
           other filters run in parallel.

       • F: Use ‘List Matches’ to ‘test’ your matching conditions. This will just match and  show
         you what filters match. Use ‘Execute’ to actually execute the action after matching your
         conditions. Use ‘Save’ to save the filter for future  use  and  ‘Reset’  to  clear  your
         settings

       NOTE:
          More details on filter conditions:
              There  are  several  different elements to an event that you can filter on, some of
              which require further explanation. These are as follows, * ‘Date/Time’  which  must
              evaluate  to  a  date  and  a time together, * ‘Date’ and ‘Time’ which are variants
              which may only contain the relevant subsets of this, * ‘Weekday’ which as  expected
              is a day of the week.

              All  of  the  preceding elements take a very flexible free format of dates and time
              based        on        the        PHP         strtotime         function         (‐
              https://www.php.net/manual/en/function.strtotime.php).  This  allows values such as
              ‘last Wednesday’ etc to be entered. We recommend  acquainting  yourself  with  this
              function  to see what the allowed formats are. However automated filters are run in
              perl and so are parsed by  the  Date::Manip  package.  Not  all  date  formats  are
              available  in  both  so  if  you are saved your filter to do automatic deletions or
              other tasks you should make  sure  that  the  date  and  time  format  you  use  is
              compatible  with  both  methods.  The  safest  type of format to use is ‘-3 day’ or
              similar with easily parseable numbers and units are in English.

              The other things you can filter on are all fairly self explanatory, except  perhaps
              for  ‘Archived’ which you can use to include or exclude Archived events. In general
              you’ll probably do most  filtering  on  un-archived  events.  There  are  also  two
              elements,  Disk  Blocks  and Disk Percent which don’t directly relate to the events
              themselves but to the disk partition on which the events are  stored.  These  allow
              you  to  specify  an  amount  of  disk  usage  either in blocks or in percentage as
              returned by the ‘df’ command. They relate to the amount of disk space used and  not
              the  amount left free. Once your filter is specified, clicking ‘submit’ will filter
              the events according to your specification. As the  disk  based  elements  are  not
              event  related  directly if you create a filter and include the term ‘DiskPercent >
              95’ then if your current disk usage is over that amount when you submit the  filter
              then all events will be listed whereas if it is less then none at all will. As such
              the disk related terms will tend to be  used  mostly  for  automatic  filters  (see
              below).  If you have created a filter you want to keep, you can name it and save it
              by clicking ‘Save’.

              If you do this then the subsequent dialog will also allow you specify  whether  you
              want  this  filter automatically applied in order to delete events or upload events
              via ftp to another server and mail notifications of events to  one  or  more  email
              accounts.  Emails and messages (essentially small emails intended for mobile phones
              or pagers) have a format defined in the Options screen, and may include  a  variety
              of  tokens  that  can  be  substituted for various details of the event that caused
              them. This includes links to the event view or the filter as well as the option  of
              attaching images or videos to the email itself. Be aware that tokens that represent
              links may require you to log in to  access  the  actual  page,  and  sometimes  may
              function  differently  when  viewed  outside of the general ZoneMinder context. The
              tokens you can use are as follows.

          • %EI%       Id of the event

          • %EN%       Name of the event

          • %EC%       Cause of the event

          • %ED%       Event description

          • %ET%       Time of the event

          • %EL%       Length of the event

          • %EF%       Number of frames in the event

          • %EFA%      Number of alarm frames in the event

          • %EST%      Total score of the event

          • %ESA%      Average score of the event

          • %ESM%      Maximum score of the event

          • %EP%       Path to the event

          • %EPS%      Path to the event stream

          • %EPF1%     Path to the frame view for the first alarmed event image

          • %EPFM%     Path to the frame view for the (first) event image with the highest score

          • %EPFMOD%   Path to image containing object detection, in frame view

          • %EPFMODG%  Path to image containing object detection animated gif version,  in  frame
            view

          • %EPI%      Path to the event images

          • %EPI1%     Path to the first alarmed event image, suitable for use in img tags

          • %EPIM%      Path  to the (first) event image with the highest score, suitable for use
            in img tags

          • %EPIMOD%   Path to image containing object detection, suitable for use in img tags

          • %EPIMODG%  Path to image containing object detection animated gif  version,  suitable
            for use in img tags

          •

            %EI1% Attach first alarmed event image

                   • %EI1A%     Attach first alarmed event analysis image

          •

            %EIM% Attach (first) event image with the highest score

                   • %EIMA%     Attach (first) event analysis image with the highest score

          • %EIMOD%    Attach image containing object detection

          • %EIMODG%   Attach image containing object detection animated gif version

          •

            %EV% Attach event mpeg video

                   • %EVM%      Attach event mpeg video in phone format

          • %MN%       Name of the monitor

          • %MET%      Total number of events for the monitor

          • %MEH%      Number of events for the monitor in the last hour

          • %MED%      Number of events for the monitor in the last day

          • %MEW%      Number of events for the monitor in the last week

          • %MEM%      Number of events for the monitor in the last month

          • %MEA%      Number of archived events for the monitor

          • %MP%       Path to the monitor window

          • %MPS%      Path to the monitor stream

          • %MPI%      Path to the monitor recent image

          • %FN%       Name of the current filter that matched

          • %FP%       Path to the current filter that matched

          • %ZP%       Path to your ZoneMinder console
              Finally  you  can  also  specify  a script which is run on each matched event. This
              script should be readable and executable by your web server user. It will  get  run
              once  per  event  and  the  relative  path to the directory containing the event in
              question. Normally this will be of the form <MonitorName>/<EventId>  so  from  this
              path  you  can derive both the monitor name and event id and perform any action you
              wish. Note that arbitrary commands are not allowed to be specified in  the  filter,
              for  security the only thing it may contain is the full path to an executable. What
              that contains is entirely up to you however.

              Filtering is a powerful mechanism you can  use  to  eliminate  events  that  fit  a
              certain  pattern  however  in  many  cases  modifying the zone settings will better
              address this. Where it really comes into its own  is  generally  in  applying  time
              filters,  so for instance events that happen during weekdays or at certain times of
              the day are highlighted, uploaded or deleted. Additionally using disk related terms
              in  your  filters means you can automatically create filters that delete the oldest
              events when your disk gets full. Be warned however that if you  use  this  strategy
              then you should limit the returned results to the amount of events you want deleted
              in each pass until the disk usage is at an acceptable level. If you do not do  this
              then  the  first  pass when the disk usage is high will match, and then delete, all
              events unless you have used other criteria inside of limits. ZoneMinder ships  with
              a sample filter already installed, though disabled. The PurgeWhenFull filter can be
              used to delete the oldest events when your disk starts filling up. To  use  it  you
              should  select and load it in the filter interface, modify it to your requirements,
              and then save it making you sure you check the ‘Delete all  matches’  option.  This
              will  then  run  in  the background and ensure that your disk does not fill up with
              events.

   Saving filters
       When saving filters, if you want the filter to run in the background make sure you  select
       the  “Run filter in background” option. When checked, ZoneMinder will make sure the filter
       is checked regularly. For example, if you want to be notified of new events by email,  you
       should  make  sure  this  is checked. Filters that are configured to run in the background
       have a “*” next to it.

   How filters actually work
       It is useful to know how filters actually work behind the scenes  in  ZoneMinder,  in  the
       event you find your filter not functioning as intended:

       • Each  filter  set  to  run  in  the  background  will  be run in it’s own process called
         zmfilter.pl which retrieves filters from the Filters database table

       • zmfilter.pl runs every FILTER_EXECUTE_INTERVAL seconds (default is 20s, can  be  changed
         in Options->System)

       • after  each  interval  the  filter  will query the database and apply the action to each
         matching event.

       • zmfilter.pl also reloads  the  filter  every  FILTER_RELOAD_DELAY  seconds  (default  is
         300s/5mins, can be changed in Options->System)

       • In  previous  versions of ZoneMinder filter changes would not take immediate effect, but
         now the web ui will start/stop/restart filters as appropriate upon editing a filter.

   Relative items in date strings
       Relative items adjust a date (or the current  date  if  none)  forward  or  backward.  The
       effects of relative items accumulate. Here are some examples:

          * 1 year
          * 1 year ago
          * 3 years
          * 2 days

       The  unit  of time displacement may be selected by the string ‘year’ or ‘month’ for moving
       by whole years or months. These are fuzzy units, as years and months are not all of  equal
       duration.  More precise units are ‘fortnight’ which is worth 14 days, ‘week’ worth 7 days,
       ‘day’ worth 24 hours, ‘hour’ worth 60 minutes, ‘minute’ or ‘min’  worth  60  seconds,  and
       ‘second’ or ‘sec’ worth one second. An ‘s’ suffix on these units is accepted and ignored.

       The  unit  of  time may be preceded by a multiplier, given as an optionally signed number.
       Unsigned numbers are taken as positively  signed.  No  number  at  all  implies  1  for  a
       multiplier.  Following  a relative item by the string ‘ago’ is equivalent to preceding the
       unit by a multiplier with value -1.

       The string ‘tomorrow’ is worth one day in the future (equivalent  to  ‘day’),  the  string
       ‘yesterday’ is worth one day in the past (equivalent to ‘day ago’).

       The  strings  ‘now’  or  ‘today’  are  relative  items  corresponding  to zero-valued time
       displacement, these strings come from the fact a zero-valued time displacement  represents
       the  current time when not otherwise changed by previous items. They may be used to stress
       other items, like in  ‘12:00  today’.  The  string  ‘this’  also  has  the  meaning  of  a
       zero-valued time displacement, but is preferred in date strings like ‘this thursday’.

       When  a  relative item causes the resulting date to cross a boundary where the clocks were
       adjusted, typically for daylight saving time, the resulting date  and  time  are  adjusted
       accordingly.

       The  fuzz  in  units  can  cause problems with relative items. For example, ‘2003-07-31 -1
       month’ might evaluate to 2003-07-01, because 2003-06-31 is an invalid date.  To  determine
       the previous month more reliably, you can ask for the month before the 15th of the current
       month. For example:

          $ date -R

          Thu, 31 Jul 2003 13:02:39 -0700

          $ date --date='-1 month' +'Last month was %B?'

          Last month was July?

          $ date --date="$(date +%Y-%m-15) -1 month" +'Last month was %B!'

          Last month was June!

       As this applies to ZoneMinder filters, you might want to search  for events in a period of
       time,  or  maybe for example create a purge filter that removes events older than 30 days.
       For the later you would want at least two lines in your filter. The first line should be:
          [<Archive Status> <equal to> <Unarchived Only>]

       as you don’t want to delete your archived events.

       Your second line to find events older than 30 days would be:
          [and <Date><less than> -30 days]

       You use “less than” to indicate that you want to match events before the  specified  date,
       and  you  specify “-30 days” to indicate a date 30 days before the time the filter is run.
       Of course you could use 30 days ago as well(?).

       You should always test your filters before enabling any actions based on them to make sure
       they  consistently  return the results you want. You can use the submit button to see what
       events are returned by your query.

   Caveat with Relative items
       One thing to remember if you specify relative dates like “now” or  “1  minute  ago”,  etc,
       they  are  converted  to  a  specific  date  and  time  by  Zoneminder’s filtering process
       (zmfilter.pl) when the filters are loaded. They are _NOT_ recomputed each time the  filter
       runs.  Filters  are  re-loaded  depending  on  the  value specified by FILTER_RELOAD_DELAY
       variable in  the Zoneminder Web Console->Options->System

       This may cause confusion in the following cases, for example: Let’s say a  user  specifies
       that  he wants to be notified of events via email the moment the event “DateTime” is “less
       than” “now” as a filter criteria. When the filter first gets loaded by  zmfilter.pl,  this
       will translate to “Match events where Start Time < ” + localtime() where local time is the
       time that is resolved when this filter gets loaded. Now till  the  time  the  filter  gets
       reloaded  after  FILTER_RELOAD_DELAY  seconds  (which  is usually set to 300 seconds, or 5
       minutes), that time does not get recomputed, so the filter will not process any new events
       that occur after that computed date till another 5 minutes, which is probably not what you
       want.

   Troubleshooting tips
       If your filter is not working, here are some useful tips:

       • Look at Info and Debug logs in Zoneminder

       • Run sudo zmfilter.pl -f <yourfiltername> from command line and see the log output

       • Check how long your action is taking - zmfilter.pl will wait for the action to  complete
         before it checks again

       • If  you  are using relative times like ‘now’ or ‘1 year ago’ etc. remember that zmfilter
         converts that relative time to an absolute date only when it reloads filters,  which  is
         dictated  by the FILTER_RELOAD_DELAY duration. So, for example, if you are wondering why
         your events are not being detected before intervals of 5 minutes and you have used  such
         a relative condition, this is why

       • In  the event that you see your new filter is working great when you try it out from the
         Web Console (using the Submit or Execute button) but does not  seem  to  work  when  its
         running  in  background  mode,  you  might  have just chanced upon a compatibility issue
         between how Perl and PHP translate free form text to dates/times. When you test  it  via
         the  “Submit”  or “Execute” button, you are invoking a PHP function for time conversion.
         When the filter runs in background mode, zmfilter.pl calls a perl  equivalent  function.
         In  some cases, depending on the version of Perl and PHP you have, the results may vary.
         If you face this situation, the  best  thing  to  do  is  to  run  sudo  zmfilter.pl  -f
         <yourfiltername> from a terminal to make sure the filter actually works in Perl as well.

   Viewing Events
       From  the  monitor  or filtered events listing you can now click on an event to view it in
       more detail.

       This is an example view that shows events for a specific monitor: [image]

       If you have streaming capability you will see a series of images that make up  the  event.
       Under  that  you should also see a progress bar. Depending on your configuration this will
       either be static or will be filled in to indicate how far through the event  you  are.  By
       default  this functionality is turned off for low bandwidth settings as the image delivery
       tends to not be able to keep up with real-time and the progress bar cannot take this  into
       account.  Regardless  of whether the progress bar updates, you can click on it to navigate
       to particular points in the events.

       You will also see a link to allow you to view the still images themselves.  If  you  don’t
       have  streaming  then  you  will be taken directly to this page. The images themselves are
       thumbnail size and depending on the configuration  and  bandwidth  you  have  chosen  will
       either  be  the  full  images scaled in your browser of actual scaled images. If it is the
       latter, if you have low bandwidth for example, it may take a few seconds to  generate  the
       images.  If  thumbnail  images  are  required  to  be generated, they will be kept and not
       re-generated in future. Once the images appear you can mouse over them to  get  the  image
       sequence number and the image score.

       Here is an example of viewing an event stream: [image]

       The image above shows a typical window for an event that was recorded as an MP4 video

   Options
       The  various  options  you can specify are displayed in a tabbed dialog with each group of
       options displayed under a different heading. Each option is displayed  with  its  name,  a
       short description and the current value. You can also click on the ‘?’ link following each
       description to get a fuller explanation about each option. This is the same as  you  would
       get  from  zmconfig.pl.  A number of option groups have a master option near the top which
       enables or disables the whole group so you should be aware of the  state  of  this  before
       modifying options and expecting them to make any difference.

       If  you  have  changed  the  value of an option you should then ‘save’ it. A number of the
       option groups will then prompt you to let you know that the  option(s)  you  have  changed
       will require a system restart. This is not done automatically in case you will be changing
       many values in the same session, however once you have made all of your changes you should
       restart  ZoneMinder  as soon as possible. The reason for this is that web and some scripts
       will pick up the new changes immediately but some of the daemons will still be  using  the
       old values and this can lead to data inconsistency or loss.

       NOTE:
          If  you  are  looking for Options->Paths documentation, it was moved to a configuration
          file starting ZoneMinder 1.32. See here.

   Options - Display
       This option screen allows user to select the  skin  for  ZoneMinder.  Currently  available
       styles  are: [image]

   Options - System
       This screen allows the admin to configure various core operations of the system.

       A partial screenshot is shown below: [image]

       SKIN_DEFAULT  -  ZoneMinder  allows  the use of many different web interfaces. This option
       allows you to set the default skin used by the website. Users can change their skin later,
       this merely sets the default.

       CSS_DEFAULT  -  ZoneMinder allows the use of many different web interfaces, and some skins
       allow the use of different set of CSS files to control the appearance. This option  allows
       you  to  set  the default set of css files used by the website. Users can change their css
       later, this merely sets the default.

       LANG_DEFAULT - ZoneMinder allows the web interface to use languages other than English  if
       the  appropriate  language file has been created and is present. This option allows you to
       change the default language that is used from the shipped language,  British  English,  to
       another language.

       OPT_USE_AUTH   -   ZoneMinder   can  run  in  two  modes.  The  simplest  is  an  entirely
       unauthenticated mode where anyone can access ZoneMinder and perform  all  tasks.  This  is
       most  suitable for installations where the web server access is limited in other ways. The
       other mode enables user accounts with varying sets of permissions.  Users  must  login  or
       authenticate   to  access  ZoneMinder  and  are  limited  by  their  defined  permissions.
       Authenticated mode  alone  should  not  be  relied  up  for  securing  Internet  connected
       ZoneMinder.

       AUTH_TYPE  -  ZoneMinder  can  use  two  methods  to  authenticate  users  when running in
       authenticated mode. The first is a builtin method where ZoneMinder provides facilities for
       users  to  log  in  and  maintains  track  of  their  identity.  The  second method allows
       interworking with other  methods  such  as  http  basic  authentication  which  passes  an
       independently  authenticated ‘remote’ user via http. In this case ZoneMinder would use the
       supplied user without additional authentication provided such  a  user  is  configured  in
       ZoneMinder.

       AUTH_RELAY  -  When  ZoneMinder  is running in authenticated mode it can pass user details
       between the web pages and the back end processes. There are two methods  for  doing  this.
       This  first  is  to  use a time limited hashed string which contains no direct username or
       password details, the second method is to  pass  the  username  and  passwords  around  in
       plaintext.  This  method  is  not recommend except where you do not have the md5 libraries
       available on your system or you have a completely isolated system with no external access.
       You can also switch off authentication relaying if your system is isolated in other ways.

       AUTH_HASH_SECRET - When ZoneMinder is running in hashed authenticated mode it is necessary
       to generate hashed strings containing encrypted sensitive information  such  as  usernames
       and  passwords.  Although  these  strings  are  reasonably secure the addition of a random
       secret increases security substantially. Note that if you are using the  new  token  based
       APIs, then this field is mandatory with ZM 1.34 and above.

       AUTH_HASH_IPS  - When ZoneMinder is running in hashed authenticated mode it can optionally
       include the requesting IP address in the resultant hash.  This  adds  an  extra  level  of
       security  as  only  requests from that address may use that authentication key. However in
       some circumstances, such as access over mobile networks, the requesting address can change
       for each request which will cause most requests to fail. This option allows you to control
       whether IP addresses are included in the  authentication  hash  on  your  system.  If  you
       experience  intermitent  problems with authentication, switching this option off may help.
       It is recommended you keep this off if you  use  mobile  apps  like  zmNinja  over  mobile
       carrier  networks  -  several  APNs  change  the  IP  very  frequently which may result in
       authentication failures.

       AUTH_HASH_TTL - Time before ZM auth will expire  (does  not  apply  to  API  tokens).  The
       default  has  traditionally  been 2 hours. A new hash will automatically be regenerated at
       half this value.

       AUTH_HASH_LOGINS - The normal process for logging into ZoneMinder is via the login  screen
       with  username  and  password.  In  some circumstances it may be desirable to allow access
       directly to one or more pages, for instance from a third party application. If this option
       is  enabled  then  adding an ‘auth’ parameter to any request will include a shortcut login
       bypassing the login screen, if not already logged in. As authentication  hashes  are  time
       and,  optionally,  IP limited, this can allow short-term access to ZoneMinder screens from
       other web pages etc. In order to use this, the calling application will have  to  generate
       the  authentication  hash itself and ensure it is valid. If you use this option you should
       ensure that you have modified the ZM_AUTH_HASH_SECRET to something unique to your system.

       ENABLE_CSRF_MAGIC - CSRF stands for  Cross-Site  Request  Forgery  which,  under  specific
       circumstances,  can allow an attacker to perform any task your ZoneMinder user account has
       permission to perform. To accomplish this, the attacker must write  a  very  specific  web
       page  and  get you to navigate to it, while you are logged into the ZoneMinder web console
       at the same time. Enabling ZM_ENABLE_CSRF_MAGIC will help mitigate these kinds of attacks.
       If you are using zmNinja and face access issues, you might try turning this off.

       OPT_USE_API  - A global setting to enable/disable ZoneMinder APIs. If you are using mobile
       apps like zmNinja, this needs to be enabled

       NOTE:
          If you are using zmNinja along with authentication, please make  sure  AUTH_HASH_LOGINS
          is  enabled,  OPT_USE_API is elabled, AUTH_RELAY is set to hashed, AUTH_HASH_IPS is off
          and a valid AUTH_HASHED_SECRET is specified.

       OPT_USE_LEGACY_AUTH  -  Starting  version  1.34.0,   ZoneMinder   uses   a   more   secure
       Authentication  mechanism  using  JWT  tokens. Older versions used a less secure MD5 based
       auth hash. It is recommended you turn this off after you are sure you don’t  need  it.  If
       you  are using a 3rd party app that relies on the older API auth mechanisms, you will have
       to update that app if you turn this off. Note that zmNinja 1.3.057  onwards  supports  the
       new token system.

       OPT_USE_EVENT_NOTIFICATION  - zmeventnotification is a 3rd party event notification server
       that is used to get notifications for alarms detected by ZoneMinder in real time.  zmNinja
       requires this server for push notifications to mobile phones. This option only enables the
       server if it is already installed. Please visit the Event Notification Server project site
       for installation instructions.

       OPT_USE_GOOG_RECAPTCHA  -  This option allows you to include a google reCaptcha validation
       at login. This means in addition to providing a valid username and password, you will also
       have  to  pass  the  reCaptcha  test. Please note that enabling this option results in the
       zoneminder login page reaching out to google servers for captcha validation.  Also  please
       note  that  enabling  this  option  may  break 3rd party clients if they rely on web based
       logins (Note that zmNinja now uses the API based token method and will not be affected  if
       reCAPTCHA  is  enabled). If you enable this, you also need to specify your site and secret
       key (please refer to context help in the ZoneMinder system screen).

       SYSTEM_SHUTDOWN - this option puts a poweroff icon in the header of the ZM  UI  for  users
       with  System  privilege accessi. This icon will allow the user to shutdown the full system
       via the ZM UI. The system will need to have sudo installed  and  the  following  added  to
       /etc/sudoers:

          www-data ALL=NOPASSWD: /sbin/shutdown

       to perform the shutdown or reboot

       OPT_FAST_DELETE  - Normally an event created as the result of an alarm consists of entries
       in one or more database tables plus the various files associated with  it.  When  deleting
       events in the browser it can take a long time to remove all of this if youxr are trying to
       do a lot of events at once. NOTE: It is recommended that you keep this option OFF,  unless
       you are running on an old or low-powered system.

       FILTER_RELOAD_DELAY  -  ZoneMinder  allows you to save filters to the database which allow
       events that match certain criteria to be emailed, deleted or uploaded to a remote  machine
       etc. The zmfilter daemon loads these and does the actual operation. This option determines
       how often in seconds the filters are reloaded from the database to get the latest versions
       or  new  filters.  If you don’t change filters very often this value can be set to a large
       value. As of 1.34.0 filters should be automatically reloaded when saving a filter so  this
       setting should have little effect.

       FILTER_EXECUTE_INTERVAL  -  ZoneMinder  allows  you  to save filters to the database which
       allow events that match certain criteria to be emailed, deleted or uploaded  to  a  remote
       machine  etc.  The  zmfilter daemon loads these and does the actual operation. This option
       determines how often the filters are executed on the saved event in the database.  If  you
       want  a  rapid  response  to  new  events this should be a smaller value, however this may
       increase the overall load on the system and affect performance of other elements.

       MAX_RESTART_DELAY - The zmdc (zm daemon control) process  controls  when  processeses  are
       started or stopped and will attempt to restart any that fail. If a daemon fails frequently
       then a delay is introduced between each restart attempt. If the daemon stills  fails  then
       this  delay  is  increased  to  prevent extra load being placed on the system by continual
       restarts. This option controls what this maximum delay is.

       STATUS_UPDATE_INTERVAL - The  zmstats  daemon  performs  various  db  queries  related  to
       collecting  system  statistics  that  may  take a long time in the background. This option
       decides how often this update is scheduled.

       WATCH_CHECK_INTERVAL - The zmwatch daemon checks the  image  capture  performance  of  the
       capture  daemons  to  ensure  that  they have not locked up (rarely a sync error may occur
       which blocks indefinitely). This option determines how often the daemons are checked.

       WATCH_MAX_DELAY - The zmwatch daemon checks the image capture performance of  the  capture
       daemons to ensure that they have not locked up (rarely a sync error may occur which blocks
       indefinitely). This option determines the maximum delay to allow since the  last  captured
       frame.  The  daemon  will be restarted if it has not captured any images after this period
       though the actual restart may take slightly longer in conjunction with the check  interval
       value  above.   Please  note  that  some  cameras can take up to 30 seconds to get a valid
       image, so this setting should be larger than that.

       RUN_AUDIT - The zmaudit daemon exists to check that the saved information in the  database
       and  on  the filesystem match and are consistent with each other. If an error occurs or if
       you are using ‘fast deletes’ it may be that database records are deleted but files remain.
       In  this  case,  and similar, zmaudit will remove redundant information to synchronise the
       two data stores. This option controls  whether  zmaudit  is  run  in  the  background  and
       performs  these checks and fixes continuously. It is recommended you keep this OFF in most
       systems and run it manually if needed after a system crash.

       AUDIT_CHECK_INTERVAL - The zmaudit daemon exists to check that the  saved  information  in
       the  database  and on the filesystem match and are consistent with each other. If an error
       occurs or if you are using ‘fast deletes’ it may be that database records are deleted  but
       files  remain.  In  this  case,  and similar, zmaudit will remove redundant information to
       synchronise the two data stores. The default check interval of 900 seconds (15 minutes) is
       fine  for  most  systems  however if you have a very large number of events the process of
       scanning the database and filesystem may take a long time and impact performance. In  this
       case you may prefer to make this interval much larger to reduce the impact on your system.
       This option determines how often these checks are performed.

       AUDIT_MIN_AGE - The zmaudit daemon exists to check  that  the  saved  information  in  the
       database and on the filesystem match and are consistent with each other. Event files or db
       records that are younger than this setting will not be deleted and a warning will be given

       OPT_CONTROL - ZoneMinder includes limited support for controllable cameras.  A  number  of
       sample  protocols are included and others can easily be added. If you wish to control your
       cameras via ZoneMinder then select this option otherwise if you only have  static  cameras
       or use other control methods then leave this option off.

       OPT_TRIGGERS  -  ZoneMinder  can  interact  with  external  systems which prompt or cancel
       alarms. This is done via the zmtrigger.pl script. This option indicates whether  you  want
       to use these external triggers. Most people will say no here.

       CHECK_FOR_UPDATES  -  To  save checking manually for each new version ZoneMinder can check
       with the zoneminder.com website to determine the most recent  release.  These  checks  are
       infrequent,  about  once  per  week,  and no personal or system information is transmitted
       other than your current version number. If you do not wish these checks to take  place  or
       your  ZoneMinder  system  has  no internet access you can switch these check off with this
       configuration variable.

       TELEMETRY_DATA - Enable collection of usage information of the local system and send it to
       the  ZoneMinder  development team. This data will be used to determine things like who and
       where our customers are, how big their systems are, the underlying hardware and  operating
       system,  etc. This is being done for the sole purpose of creating a better product for our
       target audience. This script is intended to be completely transparent to the end user, and
       can  be  disabled from the web console under Options. For more details on what information
       we collect, please refer to Zoneminder’s privacy statement (available  in  the  contextual
       help of TELEMETRY_DATA on your installation).

       UPDATE_CHECK_PROXY  -  If  you use a proxy to access the internet then ZoneMinder needs to
       know so it can access zoneminder.com to check for updates. If you do use a proxy enter the
       full proxy url here in the form of http://<proxy host>:<proxy port>/.

       SHM_KEY  -  ZoneMinder  uses  shared  memory to speed up communication between modules. To
       identify the right area to use shared memory keys are used. This option controls what  the
       base  key  is,  each monitor will have it’s Id or’ed with this to get the actual key used.
       You will not normally need to change this value unless it clashes with another instance of
       ZoneMinder  on  the  same machine. Only the first four hex digits are used, the lower four
       will be masked out and ignored.

       COOKIE_LIFETIME - This will affect how long a session will be valid  for  since  the  last
       request. Keeping this short helps prevent session hijacking. Keeping it long allows you to
       stay logged in longer without refreshing the view. We  recommend  you  keep  this  to  the
       default of 3600 if you are not sure.

   Options - Config
       The  config  screen allows the admin to change various configuration parameters related to
       image capturing and storage.

       A partial screenshot is shown below: [image]

       TIMESTAMP_ON_CAPTURE - ZoneMinder can add a timestamp to images in two ways.  The  default
       method,  when  this  option  is  set,  is  that each image is timestamped immediately when
       captured and so the image held in memory is marked right away. The second method does  not
       timestamp  the images until they are either saved as part of an event or accessed over the
       web. The timestamp used in both methods will contain the same time as  this  is  preserved
       along  with the image. The first method ensures that an image is timestamped regardless of
       any other circumstances but will result in all images being timestamped even  those  never
       saved  or viewed. The second method necessitates that saved images are copied before being
       saved otherwise two timestamps perhaps at different scales may be applied.  This  has  the
       (perhaps)  desirable  side  effect  that  the  timestamp  is  always  applied  at the same
       resolution so an image that has scaling applied will still have a  legible  and  correctly
       scaled timestamp.

       TIMESTAMP_CODE_CHAR  - There are a few codes one can use to tell ZoneMinder to insert data
       into the timestamp of each image. Traditionally, the percent (%) character has  been  used
       to  identify  these  codes  since  the  current  character  codes do not conflict with the
       strftime codes, which can also be used in the timestamp. While this works well for  Linux,
       this  does  not  work  well  for  BSD operating systems. Changing the default character to
       something else, such as an exclamation point (!),  resolves  the  issue.  Note  this  only
       affects  the  timestamp  codes  built  into  ZoneMinder. It has no effect on the family of
       strftime codes one can use.

       CPU_EXTENSIONS - When advanced processor extensions such as SSE2 or SSSE3  are  available,
       ZoneMinder  can  use  them,  which  should  increase  performance  and reduce system load.
       Enabling this option on processors that do not support the advanced processors  extensions
       used by ZoneMinder is harmless and will have no effect.

       FAST_IMAGE_BLENDS - To detect alarms ZoneMinder needs to blend the captured image with the
       stored reference image to update it for comparison with  the  next  image.  The  reference
       blend  percentage  specified  for  the monitor controls how much the new image affects the
       reference image. There are two methods that are available for this. If this option is  set
       then  fast  calculation  which  does  not use any multiplication or division is used. This
       calculation is extremely fast, however it limits the possible blend  percentages  to  50%,
       25%,  12.5%,  6.25%,  3.25%  and  1.5%.  Any other blend percentage will be rounded to the
       nearest possible one. The alternative is to  switch  this  option  off  and  use  standard
       blending instead, which is slower.

       OPT_ADAPTIVE_SKIP  -  In previous versions of ZoneMinder the analysis daemon would attempt
       to keep up with the capture daemon by processing the last captured  frame  on  each  pass.
       This  would  sometimes  have the undesirable side-effect of missing a chunk of the initial
       activity that caused the alarm because the pre-alarm frames would all have to  be  written
       to  disk  and the database before processing the next frame, leading to some delay between
       the first and second event frames. Setting this option enables a newer adaptive  algorithm
       where  the  analysis  daemon attempts to process as many captured frames as possible, only
       skipping frames when in danger of the capture  daemon  overwriting  yet  to  be  processed
       frames.  This  skip is variable depending on the size of the ring buffer and the amount of
       space left in it. Enabling this option will give you much better coverage of the beginning
       of  alarms  whilst  biasing out any skipped frames towards the middle or end of the event.
       However you should be aware that this will have the effect of making the  analysis  daemon
       run  somewhat  behind  the capture daemon during events and for particularly fast rates of
       capture it is possible for the adaptive algorithm to be overwhelmed and not have  time  to
       react  to  a  rapid  build up of pending frames and thus for a buffer overrun condition to
       occur.

       MAX_SUSPEND_TIME - ZoneMinder allows monitors to have motion detection  to  be  suspended,
       for  instance  while  panning  a  camera.  Ordinarily this relies on the operator resuming
       motion detection afterwards as failure to do so can  leave  a  monitor  in  a  permanently
       suspended  state.  This  setting  allows  you  to set a maximum time which a camera may be
       suspended for before it automatically resumes motion detection. This time can be  extended
       by  subsequent suspend indications after the first so continuous camera movement will also
       occur while the monitor is suspended.

       STRICT_VIDEO_CONFIG - With some video devices  errors  can  be  reported  in  setting  the
       various  video attributes when in fact the operation was successful. Switching this option
       off will still allow these errors to be reported but will not cause them to kill the video
       capture daemon. Note however that doing this will cause all errors to be ignored including
       those which are genuine and which may cause the video capture to not  function  correctly.
       Use this option with caution.

       LD_PRELOAD  -  Some older cameras require the use of the v4l1 compat library. This setting
       allows the setting of the path to the library, so that it can be loaded by zmdc.pl  before
       launching zmc.

       V4L_MULTI_BUFFER  -  Performance  when  using  Video  4  Linux  devices is usually best if
       multiple buffers are used allowing the next image to be captured while the previous one is
       being  processed.  If  you have multiple devices on a card sharing one input that requires
       switching then this approach can sometimes cause frames from one source  to  be  mixed  up
       with  frames from another. Switching this option off prevents multi buffering resulting in
       slower but more stable image capture. This option is ignored for non-local cameras  or  if
       only  one  input  is present on a capture chip. This option addresses a similar problem to
       the ZM_CAPTURES_PER_FRAME option and you should normally change the value of only  one  of
       the options at a time.  If you have different capture cards that need different values you
       can ovveride them in each individual monitor on the source page.

       CAPTURES_PER_FRAME - If you are using cameras attached  to  a  video  capture  card  which
       forces  multiple  inputs  to  share one capture chip, it can sometimes produce images with
       interlaced frames reversed resulting in poor image quality and  a  distinctive  comb  edge
       appearance.  Increasing  this setting allows you to force additional image captures before
       one is selected as the captured frame. This allows the capture hardware to  ‘settle  down’
       and produce better quality images at the price of lesser capture rates. This option has no
       effect on (a) network cameras, or (b) where multiple inputs do not share a  capture  chip.
       This  option  addresses a similar problem to the ZM_V4L_MULTI_BUFFER option and you should
       normally change the value of only one of the options at a time.   If  you  have  different
       capture  cards that need different values you can ovveride them in each individual monitor
       on the source page.

       FORCED_ALARM_SCORE - The ‘zmu’ utility can be used to force an alarm on a  monitor  rather
       than  rely  on  the motion detection algorithms. This option determines what score to give
       these alarms to distinguish them from regular ones. It must be 255 or less.

       BULK_FRAME_INTERVAL - Traditionally ZoneMinder writes an entry into  the  Frames  database
       table  for  each  frame  that  is  captured and saved. This works well in motion detection
       scenarios but when in a DVR situation (‘Record’ or ‘Mocord’ mode) this results in  a  huge
       number of frame writes and a lot of database and disk bandwidth for very little additional
       information. Setting this to a non-zero value  will  enabled  ZoneMinder  to  group  these
       non-alarm frames into one ‘bulk’ frame entry which saves a lot of bandwidth and space. The
       only disadvantage of this is that timing information for individual frames is lost but  in
       constant frame rate situations this is usually not significant. This setting is ignored in
       Modect mode and individual frames are still written if an  alarm  occurs  in  Mocord  mode
       also.

       EVENT_CLOSE_MODE  -  When  a  monitor is running in a continuous recording mode (Record or
       Mocord) events are usually closed after a fixed  period  of  time  (the  section  length).
       However  in  Mocord  mode it is possible that motion detection may occur near the end of a
       section. This option controls what happens when an alarm occurs in Mocord mode. The ‘time’
       setting  means that the event will be closed at the end of the section regardless of alarm
       activity. The ‘idle’ setting means that the event will be closed at the end of the section
       if  there  is no alarm activity occurring at the time otherwise it will be closed once the
       alarm is over meaning the event may end up being longer than the  normal  section  length.
       The  ‘alarm’  setting  means  that  if an alarm occurs during the event, the event will be
       closed once the alarm is over regardless of when this  occurs.  This  has  the  effect  of
       limiting  the  number  of  alarms to one per event and the events will be shorter than the
       section length if an alarm has occurred.

       WEIGHTED_ALARM_CENTRES - ZoneMinder will always calculate the centre point of an alarm  in
       a  zone  to  give  some  indication  of where on the screen it is. This can be used by the
       experimental motion tracking feature or your own custom  extensions.  In  the  alarmed  or
       filtered pixels mode this is a simple midpoint between the extents of the detected pxiesl.
       However in the blob method this can instead be calculated using weighted  pixel  locations
       to  give  more  accurate positioning for irregularly shaped blobs. This method, while more
       precise is also slower and so is turned off by default.

       EVENT_IMAGE_DIGITS - As event images are captured they are stored to the filesystem with a
       numerical index. By default this index has three digits so the numbers start 001, 002 etc.
       This works works for most scenarios as  events  with  more  than  999  frames  are  rarely
       captured. However if you have extremely long events and use external applications then you
       may wish to increase this to ensure correct sorting of images in  listings  etc.  Warning,
       increasing  this value on a live system may render existing events unviewable as the event
       will have been saved with the previous scheme. Decreasing this value should  have  no  ill
       effects.

       DEFAULT_ASPECT_RATIO - When specifying the dimensions of monitors you can click a checkbox
       to ensure that the width stays in the correct ratio to the height,  or  vice  versa.  This
       setting  allows you to indicate what the ratio of these settings should be. This should be
       specified in the format <width value>:<height value> and the default of  4:3  normally  be
       acceptable  but  11:9  is  another  common  setting.  If  the checkbox is not clicked when
       specifying monitor dimensions this setting has no effect.

       USER_SELF_EDIT - Ordinarily only users with system edit privilege are able to change users
       details.  Switching  this  option  on  allows ordinary users to change their passwords and
       their language settings

   Options - API
       NOTE:
          The ZoneMinder web interface does not use APIs and therefore, the tokens discussed here
          don’t  apply to the ZoneMinder UI. These only appy to apps that use the ZoneMinder API,
          like zmNinja.

       The API option screen allows you enable/disable APIs on a per user basis. Furthermore,  it
       also  allows  you  to “revoke” tokens allotted to users. Starting ZoneMinder 1.34, the API
       ecosystem was overhauled and we now support JWT tokens with a concept  of  refresh  tokens
       and  access  tokens. This allows for authentication without the need for sending passwords
       with each authentication request. For a more detailed understanding  of  how  this  works,
       please refer to API. Over time, more control will be added to this screen.  [image]

       The  “Revoke  All  Tokens” button can be used to globally invalidate access tokens for all
       users. If tokens are revoked, the user(s) will need  to  re-authenticate  with  login  and
       password.  As of today, refresh tokens last for 24 hours and access tokens for 1 hour.

   Options - Servers
   Todo
       needs to be refreshed
       [image]

       Servers  tab  is used for setting up multiple ZoneMinder servers sharing the same database
       and using a shared file share for all event data. To add a new server use the  Add  Server
       button. All that is required is a Name for the Server and Hostname.

       To delete a server mark that server and click the Delete button.

       Please note that all servers must have a functional web UI as the live view must come from
       the monitor’s host server.

       On each server, you will have to edit /etc/zm/zm.conf and set either ZM_SERVER_NAME=

   Options - Storage
       [image]

       Storage tab is used to setup storage areas for recorded Events. To add a new area use  the
       Add New Storage button.

       By  default  storage on local drive is automatically set up on installion. When no area is
       specified events will be stored to a default  built-in  location,  which  for  example  on
       Ubuntu is /var/cache/zoneminder/events.

       Name: Storage names - can be anything

       Path: String path to storage location for example /media/Videos

       Url:          Used          for          S3         communication         -         format
       s3fs://ACCESS_KEY_ID:SECRET_ACCESS_KEY@s3.ca-central-1.amazonaws.com/bucket-name/events

       Supported storage types:

              • Local - Local/mounted or network storage in local network

              • s3fs - S3 mounted drive

       Some users may require more advanced storage such as S3 provided by amazon or others.

   S3 storage setup
       You must use s3fs to mount the S3 bucket in your fs tree.   Telling  ZoneMinder  that  the
       location is S3 will let it use more efficient code to send and delete the event data.  The
       Do Deletes option tells ZoneMinder whether to  actually  perform  delete  operations  when
       deleting events.  S3fs systems often do deletes in a cron job or other background task and
       doing the deletes can overload an S3 system.

       Refer   to   this   guide   for    installation    and    configuration    of    s3fs    -
       https://github.com/s3fs-fuse/s3fs-fuse

       Adding credentials to passwd_file

       Create credentials file echo ACCESS_KEY_ID:SECRET_ACCESS_KEY > /etc/passwd-s3fs

       Set file permissions chmod 600 /etc/passwd-s3fs

       S3 mounting with fstab
              s3fs#bucket_name                           /media/S3                           fuse
              _netdev,allow_other,uid=33,url=https://s3.ca-central-1.amazonaws.com,passwd_file=/etc/passwd-s3fs,umask=022
              0 0

       Setting up storage.

              1. Click on Add new Storage

              2. Set path to /media/S3

              3. Add                                                                          Url
                 s3fs://username:password@s3.ca-central-1.amazonaws.com/bucket-name/events

              4. Set type to s3fs

              5. Save settings and monitor logs for errors

   Options - Web
       This screen lets you customize several aspects of  the  web  interface  of  ZoneMinder.  A
       partial screenshot is shown below: [image]

       WEB_TITLE - The actual text that is shown on the login screen. It is possible that it also
       appears in other areas.

       WEB_TITLE_PREFIX - If you have more than one installation of ZoneMinder it can be  helpful
       to display different titles for each one. Changing this option allows you to customise the
       window titles to include further information to aid identification.

       HOME_URL - the link to navigate to, when a user clicks on the top left title.

       HOME_CONTENT - The actual text that is shown on the top left corner.  You  can  choose  to
       leave it empty and put in a logo in a custom CSS as well.

       WEB_CONSOLE_BANNER  - Allows the administrator to place an arbitrary text message near the
       top of the web console. This is useful for the  developers  to  display  a  message  which
       indicates the running instance of ZoneMinder is a development snapshot, but it can also be
       used for any other purpose as well.

       WEB_EVENT_DISK_SPACE - Adds another column to the listing of events showing the disk space
       used  by  the  event.  This  will  impart a small overhead as it will call du on the event
       directory.  In  practice  this  overhead  is  fairly  small  but  may  be  noticeable   on
       IO-constrained systems.

       WEB_RESIZE_CONSOLE  -  Traditionally  the  main  ZoneMinder web console window has resized
       itself to shrink to a size small enough to  list  only  the  monitors  that  are  actually
       present.  This is intended to make the window more unobtrusize but may not be to everyones
       tastes, especially if opened in a tab in browsers  which  support  this  kind  if  layout.
       Switch this option off to have the console window size left to the users preference.

       WEB_ID_ON_CONSOLE  -  Some  find  it  useful  to have the monitor id always visible on the
       console. This option will add a column listing it. Note that if it is  disabled,  you  can
       always hover over the monitor to see the id as well.

       WEB_POPUP_ON_ALARM  -  When viewing a live monitor stream you can specify whether you want
       the window to pop to the front if an alarm occurs when the window is minimised  or  behind
       another  window. This is most useful if your monitors are over doors for example when they
       can pop up if someone comes to the doorway.

       WEB_SOUND_ON_ALARM - When viewing a live monitor stream you can specify whether  you  want
       the window to play a sound to alert you if an alarm occurs.

       WEB_ALARM_SOUND  -  You can specify a sound file to play if an alarm occurs whilst you are
       watching a live monitor stream. So long as your browser understands the format it does not
       need to be any particular type. This file should be placed in the sounds directory defined
       earlier.

       WEB_COMPACT_MONTAGE - The montage view shows the output of all of your active monitors  in
       one  window.  This  include  a  small  menu  and status information for each one. This can
       increase the web traffic and make the window larger than  may  be  desired.  Setting  this
       option on removes all this extraneous information and just displays the images.

       WEB_EVENT_SORT_FIELD  - Events in lists can be initially ordered in any way you want. This
       option controls what field is used to sort them. You can modify this ordering from filters
       or  by  clicking on headings in the lists themselves. Bear in mind however that the ‘Prev’
       and ‘Next’ links, when scrolling through events, relate to the ordering in the  lists  and
       so not always to time based ordering.

       WEB_EVENT_SORT_ORDER  - Events in lists can be initially ordered in any way you want. This
       option controls what order (ascending or descending) is used to sort them. You can  modify
       this  ordering  from  filters  or by clicking on headings in the lists themselves. Bear in
       mind however that the ‘Prev’ and ‘Next’ links, when scrolling through  events,  relate  to
       the ordering in the lists and so not always to time based ordering.

       WEB_EVENTS_PER_PAGE - In the event list view you can either list all events or just a page
       at a time. This option controls how many events are listed per page in paged mode and  how
       often to repeat the column headers in non-paged mode.

       WEB_LIST_THUMBS  -  Ordinarily  the event lists just display text details of the events to
       save space and time. By switching this option on you can also display small thumbnails  to
       help  you  identify  events of interest. The size of these thumbnails is controlled by the
       following two options.

       WEB_LIST_THUMB_WIDTH - This options controls the width of the thumbnail images that appear
       in the event lists. It should be fairly small to fit in with the rest of the table. If you
       prefer you can specify a height instead in the next option but you should only use one  of
       the  width  or height and the other option should be set to zero. If both width and height
       are specified then width will be used and height ignored.

       WEB_LIST_THUMB_HEIGHT - This options controls the height  of  the  thumbnail  images  that
       appear in the event lists. It should be fairly small to fit in with the rest of the table.
       If you prefer you can specify a width instead in the previous option but you  should  only
       use  one  of the width or height and the other option should be set to zero. If both width
       and height are specified then width will be used and height ignored.

       WEB_USE_OBJECT_TAGS - There are two methods of including media content in web  pages.  The
       most  common way is use the EMBED tag which is able to give some indication of the type of
       content. However this is not a standard part of HTML. The official method is to use OBJECT
       tags  which are able to give more information allowing the correct media viewers etc to be
       loaded. However these are less widely supported and content may be  specifically  tailored
       to a particular platform or player. This option controls whether media content is enclosed
       in EMBED tags only or whether, where appropriate, it is  additionally  wrapped  in  OBJECT
       tags.  Currently  OBJECT  tags are only used in a limited number of circumstances but they
       may become more widespread in the future. It is suggested that you leave  this  option  on
       unless you encounter problems playing some content.

       WEB_XFRAME_WARN  -  When  creating  a  Web  Site  monitor,  if  the  target  web  site has
       X-Frame-Options set to sameorigin in the header, the site will not display in  ZoneMinder.
       This  is  a design feature in most modern browsers. When this condition occurs, ZoneMinder
       will write a warning to the log file. To get around this, one can install a browser plugin
       or  extension to ignore X-Frame headers, and then the page will display properly. Once the
       plugin or extension has ben installed, the end user may choose to turn this warning off

       WEB_FILTER_SOURCE - This option only affects  monitors  with  a  source  type  of  Ffmpeg,
       Libvlc,  or  WebSite.  This  setting  controls what information is displayed in the Source
       column on the console. Selecting ‘None’ will not filter anything. The entire source string
       will be displayed, which may contain sensitive information. Selecting ‘NoCredentials’ will
       strip out usernames and passwords from the string. If there are any port  numbers  in  the
       string  and  they  are common (80, 554, etc) then those will be removed as well. Selecting
       ‘Hostname’ will filter out all information except for the hostname or ip address. When  in
       doubt, stay with the default ‘Hostname’. This feature uses the php function ‘url_parts’ to
       identify the various pieces of the url. If the url in question is unusual or not  standard
       in some way, then filtering may not produce the desired results.

   Options - Images
       This  screen lets you control various image quality settings for live and recorded events.
       A partial screenshot is shown below: [image]

       COLOUR_JPEG_FILES - Cameras that capture in greyscale can write their captured  images  to
       jpeg  files with a corresponding greyscale colour space. This saves a small amount of disk
       space over colour ones. However some tools such as ffmpeg either fail to  work  with  this
       colour space or have to convert it beforehand. Setting this option to yes uses up a little
       more space but makes creation of MPEG files much faster.

       ADD_JPEG_COMMENTS - JPEG files may have a number of extra fields added to the file header.
       The  comment  field  may  have any kind of text added. This options allows you to have the
       same text that is used to annotate the  image  additionally  included  as  a  file  header
       comment.  If  you  archive event images to other locations this may help you locate images
       for particular events or times if you use software that can read comment headers.

       JPEG_FILE_QUALITY - When ZoneMinder detects an event it will save  the  images  associated
       with that event to files. These files are in the JPEG format and can be viewed or streamed
       later. This option specifies what image quality should be used  to  save  these  files.  A
       higher  number  means  better quality but less compression so will take up more disk space
       and take longer to view over a slow connection. By contrast a low  number  means  smaller,
       quicker  to  view, files but at the price of lower quality images. This setting applies to
       all images written except if the capture image has caused an  alarm  and  the  alarm  file
       quality option is set at a higher value when that is used instead.

       JPEG_ALARM_FILE_QUALITY  -  This  value  is  equivalent  to  the regular jpeg file quality
       setting above except that it only applies to images saved while in an alarm state and then
       only  if  this value is set to a higher quality setting than the ordinary file setting. If
       set to a lower value then it is ignored. Thus leaving it at the default of  0  effectively
       means  to  use  the  regular file quality setting for all saved images. This is to prevent
       accidentally saving important images at a worse quality setting.

       JPEG_STREAM_QUALITY - When viewing a ‘live’ stream for a monitor ZoneMinder will  grab  an
       image  from  the  buffer  and  encode  it  into JPEG format before sending it. This option
       specifies what image quality should be used to encode these images. A higher number  means
       better quality but less compression so will take longer to view over a slow connection. By
       contrast a low number means quicker to view images but  at  the  price  of  lower  quality
       images.  This  option  does  not  apply  when  viewing events or still images as these are
       usually just read from disk and so will  be  encoded  at  the  quality  specified  by  the
       previous options.

       MPEG_TIMED_FRAMES  - When using streamed MPEG based video, either for live monitor streams
       or events, ZoneMinder can send the streams in two ways. If this option  is  selected  then
       the  timestamp  for  each  frame, taken from it’s capture time, is included in the stream.
       This means that where the frame rate varies, for instance around an alarm, the stream will
       still  maintain  it’s  ‘real’  timing.  If this option is not selected then an approximate
       frame rate is calculated and that is used to schedule frames instead. This  option  should
       be selected unless you encounter problems with your preferred streaming method.

       MPEG_LIVE_FORMAT  -  When  using  MPEG mode ZoneMinder can output live video. However what
       formats are handled by the browser varies greatly between machines. This option allows you
       to  specify  a  video  format  using  a file extension format, so you would just enter the
       extension of the file type you would like and  the  rest  is  determined  from  that.  The
       default  of ‘asf’ works well under Windows with Windows Media Player but I’m currently not
       sure what, if anything, works on a Linux platform. If you find out please let me know!  If
       this option is left blank then live streams will revert to being in motion jpeg format.

       MPEG_REPLAY_FORMAT  -  When  using MPEG mode ZoneMinder can replay events in encoded video
       format. However what formats are handled by the browser varies greatly  between  machines.
       This  option  allows  you  to specify a video format using a file extension format, so you
       would just enter the extension of the file type you would like and the rest is  determined
       from  that.  The  default  of ‘asf’ works well under Windows with Windows Media Player and
       ‘mpg’, or ‘avi’ etc should work under Linux. If you know any more then please let me know!
       If this option is left blank then live streams will revert to being in motion jpeg format.

       RAND_STREAM  - Some browsers can cache the streams used by ZoneMinder. In order to prevent
       this a harmless random string can be appended to the url to make each  invocation  of  the
       stream appear unique.

       OPT_CAMBOZOLA  - Cambozola is a handy low fat cheese flavoured Java applet that ZoneMinder
       uses to view image streams on browsers such  as  Internet  Explorer  that  don’t  natively
       support this format. If you use this browser it is highly recommended to install this from
       this link  however if it is not installed still images at a lower refresh rate  can  still
       be  viewed.  Note  that  practically,  if you are not using an old version of IE, you will
       likely not need this.

       PATH_CAMBOZOLA - Leave this as ‘cambozola.jar’ if  cambozola  is  installed  in  the  same
       directory as the ZoneMinder web client files.

       RELOAD_CAMBOZOLA  -  Cambozola allows for the viewing of streaming MJPEG however it caches
       the entire stream into cache space on the computer, setting this to  a  number  >  0  will
       cause it to automatically reload after that many seconds to avoid filling up a hard drive.

       OPT_FFMPEG  -  ZoneMinder  can  optionally  encode  a  series of video images into an MPEG
       encoded movie file for viewing, downloading or storage. This option allows you to  specify
       whether  you  have the ffmpeg tools installed. Note that creating MPEG files can be fairly
       CPU and disk intensive and is not a required option as events can  still  be  reviewed  as
       video streams without it.

       PATH_FFMPEG - This path should point to where ffmpeg has been installed.

       FFMPEG_INPUT_OPTIONS  -  Ffmpeg  can  take many options on the command line to control the
       quality of video produced. This option allows you to specify your own set  that  apply  to
       the  input  to  ffmpeg  (options  that  are  given before the -i option). Check the ffmpeg
       documentation for a full list of options which may be used here.

       FFMPEG_OUTPUT_OPTIONS - Ffmpeg can take many options on the command line  to  control  the
       quality  of  video  produced. This option allows you to specify your own set that apply to
       the output from ffmpeg (options that are given after the  -i  option).  Check  the  ffmpeg
       documentation  for a full list of options which may be used here. The most common one will
       often be to force an output frame rate supported by the video encoder.

       FFMPEG_FORMATS - Ffmpeg can generate video in many different formats. This  option  allows
       you to list the ones you want to be able to select. As new formats are supported by ffmpeg
       you can add them here and be able to use them immediately. Adding a  ‘*’  after  a  format
       indicates that this will be the default format used for web video, adding ‘**’ defines the
       default format for phone video.

       FFMPEG_OPEN_TIMEOUT - When Ffmpeg is opening a stream, it can  take  a  long  time  before
       failing;  certain  circumstances  even  seem  to be able to lock indefinitely. This option
       allows you to set a maximum time in seconds to pass before closing the stream  and  trying
       to reopen it again.

   Options - Logging
       ZoneMinder has a powerful logging system. Understanding how to configure logging will help
       you track issues better. The logging options  are  accessed  via  Options->Logging.  Let’s
       follow  along  with  an example. But before that, here is a basic construct of how logging
       works:

       • Every component of ZoneMinder can generate  different  types  of  logs.  Typically,  ERR
         refers  to an error condition that you should look at (in some cases, they are transient
         during  startup/shutdown  in  which  case  they  are  usually  benign).  INF  logs   are
         informational,  WAR are warning logs that might have a potential to cause issues, whilst
         DBG are debug logs that are useful when you need to debug a problems

       • You can decide where these  logs  are  written.  Typically  ZoneMinder  writes  logs  to
         multiple  sources:  *  Syslog  * Database * individual files belonging to each component
         inside the logging folder configured

       Consider for example, that you are trying to figure out why your “zmc  11”  (i.e.  Monitor
       11) is not working. Obviously, you need to enable debug logs if you are not able to figure
       out what is going on with standard info logs. But you wouldn’t want to write debug logs to
       the  Database.  Maybe, you also don’t want it polluting your syslog and only want to write
       debug logs to the debug file of _that_ component  (/var/log/zm/zmc_m11.log  for  example).
       That is where customizing your logging is useful.

   Logging example
       [image]

       In the example above, I’ve configured my logging as follows:

       • I only want to log INFO level logs to Syslog

       • I want DEBUG logs to only go to the conmponent file

       • When  it  comes  to my WEBLOG (what I see in the ZM Log window) and Database log, I only
         want FATAL logs (you may want to set this to WAR or INF)

       • I don’t want to save FFMPEG logs (this was a new feature added). FFMPEG generates a  log
         of  logs  on  its  own that you should only enable if you are trying to figure out video
         playback related issues

       • I have enabled LOG_DEBUG (unless you enable this, DEBUG logs won’t be logged)

       • The LOG_DEBUG_TARGET is useful if  you  don’t  want  to  enable  DEBUG  logs  for  every
         component.  In  this  case,  I’m  only  interested  in debugging the ZM Event Server and
         Monitor 11. Nothing else will have debug logs enabled.

       • I prefer to keep the LOG_DEBUG_FILE to empty. This creates nicely separate files  in  my
         log folder with component names

       The other logging parameters are left to their defaults, like so: [image]

   A more comprehensive explanation of the various log options
       LOG_LEVEL_SYSLOG - ZoneMinder logging is now more integrated between components and allows
       you to specify the destination for logging output and the individual levels for each. This
       option  lets  you  control  the  level  of  logging  output  that  goes to the system log.
       ZoneMinder binaries have always logged to the system log but now scripts and  web  logging
       is  also  included. To preserve the previous behaviour you should ensure this value is set
       to Info or Warning. This option controls  the  maximum  level  of  logging  that  will  be
       written, so Info includes Warnings and Errors etc. To disable entirely, set this option to
       None. You should use caution when setting this option to Debug as it can  severely  affect
       system  performance.  If  you  want  debug you will also need to set a level and component
       below

       LOG_LEVEL_FILE - ZoneMinder logging is now more integrated between components  and  allows
       you to specify the destination for logging output and the individual levels for each. This
       option lets you control the level of logging output that  goes  to  individual  log  files
       written  by specific components. This is how logging worked previously and although useful
       for tracking down issues in specific components it also resulted  in  many  disparate  log
       files.  To preserve this behaviour you should ensure this value is set to Info or Warning.
       This option controls the maximum level of logging that will be written, so  Info  includes
       Warnings  and  Errors  etc.  To  disable entirely, set this option to None. You should use
       caution when setting this option to Debug as it can  severely  affect  system  performance
       though file output has less impact than the other options. If you want debug you will also
       need to set a level and component below

       LOG_LEVEL_WEBLOG - ZoneMinder logging is now more integrated between components and allows
       you to specify the destination for logging output and the individual levels for each. This
       option lets you control the level of logging output from the web interface  that  goes  to
       the  httpd error log. Note that only web logging from PHP and JavaScript files is included
       and so this option is really only useful for  investigating  specific  issues  with  those
       components.  This  option  controls  the maximum level of logging that will be written, so
       Info includes Warnings and Errors etc. To disable entirely, set this option to  None.  You
       should  use  caution  when  setting  this option to Debug as it can severely affect system
       performance. If you want debug you will also need to set a level and component below

       LOG_LEVEL_DATABASE - ZoneMinder logging is now  more  integrated  between  components  and
       allows  you  to  specify  the destination for logging output and the individual levels for
       each. This option lets you control the level of logging output  that  is  written  to  the
       database.  This  is  a  new  option  which can make viewing logging output easier and more
       intuitive and also makes it easier to get an overall  impression  of  how  the  system  is
       performing.  If  you have a large or very busy system then it is possible that use of this
       option may slow your system down if the table becomes  very  large.  Ensure  you  use  the
       LOG_DATABASE_LIMIT option to keep the table to a manageable size. This option controls the
       maximum level of logging that will be written, so Info includes Warnings and  Errors  etc.
       To  disable  entirely,  set  this option to None. You should use caution when setting this
       option to Debug as it can severely affect system performance. If you want debug  you  will
       also need to set a level and component below

       LOG_DATABASE_LIMIT  -  If  you  are  using database logging then it is possible to quickly
       build up a large number of entries in the Logs table. This option allows  you  to  specify
       how  many  of these entries are kept. If you set this option to a number greater than zero
       then that number is used to determine the maximum number of rows, less than  or  equal  to
       zero indicates no limit and is not recommended. You can also set this value to time values
       such as ‘<n> day’ which will limit the log entries to those newer than that time. You  can
       specify ‘hour’, ‘day’, ‘week’, ‘month’ and ‘year’, note that the values should be singular
       (no ‘s’ at the end). The Logs table is pruned periodically so it is possible for more than
       the expected number of rows to be present briefly in the meantime.

       LOG_DEBUG”  -  ZoneMinder  components usually support debug logging available to help with
       diagnosing problems. Binary components have several levels of  debug  whereas  more  other
       components  have only one. Normally this is disabled to minimise performance penalties and
       avoid filling logs too quickly. This option lets you switch on other  options  that  allow
       you  to  configure additional debug information to be output. Components will pick up this
       instruction when they are restarted.

       LOG_DEBUG_TARGET - There are three scopes of debug available. Leaving  this  option  blank
       means  that  all components will use extra debug (not recommended). Setting this option to
       ‘_<component>’, e.g. _zmc, will limit extra debug to that  component  only.  Setting  this
       option  to  ‘_<component>_<identity>’,  e.g.  ‘_zmc_m1’  will  limit  extra  debug to that
       instance of the component only. This is ordinarily what you probably want to do. To  debug
       scripts  use  their  names  without the .pl extension, e.g. ‘_zmvideo’ and to debug issues
       with the web interface use ‘_web’. You can specify multiple  targets  by  separating  them
       with ‘|’ characters.

       LOG_DEBUG_LEVEL  -  There  are 9 levels of debug available, with higher numbers being more
       debug and level 0 being no debug. However not all levels are used by all components.  Also
       if  there is debug at a high level it is usually likely to be output at such a volume that
       it may obstruct normal operation. For this reason you should set the level  carefully  and
       cautiously  until  the  degree  of  debug  you wish to see is present. Scripts and the web
       interface only have one level so this is an on/off type option for them.

       LOG_DEBUG_FILE - This option allows you to specify a different target  for  debug  output.
       All  components have a default log file which will norally be in /tmp or /var/log and this
       is where debug will be written to if  this  value  is  empty.  Adding  a  path  here  will
       temporarily  redirect  debug,  and  other  logging  output, to this file. This option is a
       simple filename and you are debugging several components then they will all try and  write
       to the same file with undesirable consequences. Appending a ‘+’ to the filename will cause
       the file to be created with a ‘.<pid>’ suffix containing your  process  id.  In  this  way
       debug from each run of a component is kept separate. This is the recommended setting as it
       will also prevent subsequent runs from overwriting the same log. You  should  ensure  that
       permissions are set up to allow writing to the file and directory specified here.

       LOG_CHECK_PERIOD   -   When   ZoneMinder   is  logging  events  to  the  database  it  can
       retrospectively examine the number of warnings and errors that have occurred to  calculate
       an  overall  state  of  system  health.  This option allows you to indicate what period of
       historical events are used in this calculation. This value is expressed in seconds and  is
       ignored if LOG_LEVEL_DATABASE is set to None.

       LOG_ALERT_WAR_COUNT   -  When  ZoneMinder  is  logging  events  to  the  database  it  can
       retrospectively examine the number of warnings and errors that have occurred to  calculate
       an  overall  state  of  system health. This option allows you to specify how many warnings
       must have occurred within the defined time period to  generate  an  overall  system  alert
       state.  A  value  of  zero  means  warnings  are  not considered. This value is ignored if
       LOG_LEVEL_DATABASE is set to None.

       LOG_ALERT_ERR_COUNT  -  When  ZoneMinder  is  logging  events  to  the  database  it   can
       retrospectively  examine the number of warnings and errors that have occurred to calculate
       an overall state of system health. This option allows you to specify how many errors  must
       have  occurred within the defined time period to generate an overall system alert state. A
       value of zero means errors are not considered. This value is ignored if LOG_LEVEL_DATABASE
       is set to None.

       LOG_ALERT_FAT_COUNT   -  When  ZoneMinder  is  logging  events  to  the  database  it  can
       retrospectively examine the number of warnings and errors that have occurred to  calculate
       an overall state of system health. This option allows you to specify how many fatal errors
       (including panics) must have occurred within  the  defined  time  period  to  generate  an
       overall  system  alert  state. A value of zero means fatal errors are not considered. This
       value is ignored if LOG_LEVEL_DATABASE is set to None.

       LOG_ALARM_WAR_COUNT  -  When  ZoneMinder  is  logging  events  to  the  database  it   can
       retrospectively  examine the number of warnings and errors that have occurred to calculate
       an overall state of system health. This option allows you to  specify  how  many  warnings
       must  have  occurred  within  the  defined time period to generate an overall system alarm
       state. A value of zero means warnings  are  not  considered.  This  value  is  ignored  if
       LOG_LEVEL_DATABASE is set to None.

       LOG_ALARM_ERR_COUNT   -  When  ZoneMinder  is  logging  events  to  the  database  it  can
       retrospectively examine the number of warnings and errors that have occurred to  calculate
       an  overall state of system health. This option allows you to specify how many errors must
       have occurred within the defined time period to generate an overall system alarm state.  A
       value of zero means errors are not considered. This value is ignored if LOG_LEVEL_DATABASE
       is set to None.

       LOG_ALARM_FAT_COUNT  -  When  ZoneMinder  is  logging  events  to  the  database  it   can
       retrospectively  examine the number of warnings and errors that have occurred to calculate
       an overall state of system health. This option allows you to specify how many fatal errors
       (including  panics)  must  have  occurred  within  the  defined time period to generate an
       overall system alarm state. A value of zero means fatal errors are  not  considered.  This
       value is ignored if LOG_LEVEL_DATABASE is set to None.

       RECORD_EVENT_STATS  - This version of ZoneMinder records detailed information about events
       in the Stats table. This can help in profiling what the optimum  settings  are  for  Zones
       though this is tricky at present. However in future releases this will be done more easily
       and intuitively, especially with a large sample of events. The  default  option  of  ‘yes’
       allows this information to be collected now in readiness for this but if you are concerned
       about performance you can switch this off in which  case  no  Stats  information  will  be
       saved.

       RECORD_DIAG_IMAGES  -  In  addition  to recording event statistics you can also record the
       intermediate diagnostic images  that  display  the  results  of  the  various  checks  and
       processing  that  occur  when trying to determine if an alarm event has taken place. There
       are several of these images generated for each frame and zone  for  each  alarm  or  alert
       frame  so  this  can have a massive impact on performance. Only switch this setting on for
       debug or analysis purposes and remember to switch it off again once no longer required.

       RECORD_DIAG_IMAGES_FIFO - Adds fifo options for diagnostic images for  much  lower  impact
       diagnostics  mode.  Diagnostic  images are only written when there is a client (like a web
       browser) listening for them. If there is no  active  client  connected,  FIFO  images  are
       skipped.  Note  that  this  feature  also  needs  RECORD_DIAG_IMAGES to be on.  Note: Your
       monitor needs to be in some recording mode (modect/mocord/etc.)

       In addition to creating diagnostic images, this feature also adds a json  stream  for  the
       detection  data  so  you can see in real time the pixels or blobs detected for the motion.
       This allows for easy real time stream  of  both  delta  and  reference  images  (as  video
       streams) along with the detection numbers.

       Once  you  turn  on  RECORD_DIAG_IMAGES and the new RECORD_DIAG_IMAGES_FIFO in the logging
       options you can then use 3 new remote stream urls:

       • The delta images as an MJPEG stream (great to see  where  it  is  seeing  the  motion!):
         https://portal/zm/cgi-bin/nph-zms?mode=jpeg&bitrate=2&buffer=0&source=fifo&format=delta&monitor=1&maxfps=5&<auth>
         (change monitor,  portal  to  your  values.  <auth>  could  be  &user=user&pass=pass  or
         &auth=authval or &token=access_token)

       • The         reference         images         as         an         MJPEG         stream:
         https://portal/zm/cgi-bin/nph-zms?mode=jpeg&bitrate=2&buffer=0&source=fifo&format=reference&monitor=1&maxfps=5&<auth>
         (change  monitor,  portal  to  your  values.  <auth>  could  be  &user=user&pass=pass or
         &auth=authval or &token=access_token)

       • text                       json                       raw                        stream:
         https://portal/zm/cgi-bin/nph-zms?&buffer=0&source=fifo&format=raw&monitor=1&<auth>
         (change monitor,  portal  to  your  values,  <auth>  could  be  &user=user&pass=pass  or
         &auth=authval or &token=access_token)

       This will output a text stream on the browser like:

          {"zone":5,"type":"ALRM","pixels":778661,"avg_diff":50}
          {"zone":5,"type":"FILT","pixels":762704}
          {"zone":5,"type":"RBLB","pixels":728102,"blobs":5}
          {"zone":5,"type":"FBLB","pixels":728021,"blobs":2}
          {"zone":6,"type":"ALRM","pixels":130844,"avg_diff":44}
          {"zone":6,"type":"FILT","pixels":128608}

       There are four types of events right now: Alarm (ALRM), Filter (FILT), Raw Blob (RBLB) and
       Filtered Blobs (FBLB) that correspond to those stages of analysis. It will show the number
       of  pixels detected (along with average pixel difference against the threshold) and number
       of blobs at each stage.

       For example, here is a delta image stream from one of my monitors showing in live mode:

       https://myserver/cgi-bin/nph-zms?mode=jpeg&bitrate=2&buffer=0&source=fifo&format=delta&monitor=8&maxfps=5&user=admin&pass=mypass
       [image]

       DUMP_CORES  -  When  an  unrecoverable  error occurs in a ZoneMinder binary process is has
       traditionally been trapped and the details written to logs  to  aid  in  remote  analysis.
       However in some cases it is easier to diagnose the error if a core file, which is a memory
       dump of the process at the time of the  error,  is  created.  This  can  be  interactively
       analysed  in  the  debugger  and may reveal more or better information than that available
       from the logs. This option is recommended for advanced users only otherwise leave  at  the
       default.  Note  using  this  option  to trigger core files will mean that there will be no
       indication in the binary logs that a process has died, they will just  stop,  however  the
       zmdc  log  will  still  contain an entry. Also note that you may have to explicitly enable
       core file creation on your system via the ‘ulimit -c’ command or other means otherwise  no
       file will be created regardless of the value of this option.

   Options - Network
       [image]

       HTTP_VERSION  -  ZoneMinder  can  communicate  with  network  cameras  using either of the
       HTTP/1.1 or HTTP/1.0 standard. A server will normally fall back to the version it supports
       with  no  problem so this should usually by left at the default. However it can be changed
       to HTTP/1.0 if necessary to resolve particular issues.

       HTTP_UA - When ZoneMinder communicates with remote cameras it will identify  itself  using
       this  string and it’s version number. This is normally sufficient, however if a particular
       cameras expects only to communicate with certain browsers then this can be  changed  to  a
       different string identifying ZoneMinder as Internet Explorer or Netscape etc.

       HTTP_TIMEOUT  - When retrieving remote images ZoneMinder will wait for this length of time
       before deciding that an image is not going to arrive  and  taking  steps  to  retry.  This
       timeout is in milliseconds (1000 per second) and will apply to each part of an image if it
       is not sent in one whole chunk.

       MIN_STREAMING_PORT - ZoneMinder supports a concept called multi-port streaming.  The  core
       concept  is  that modern browsers like Chrome limit the number of simultaneous connections
       allowed from a specific domain (host name+port). In the case of Chrome this  value  is  6,
       which  means  you can’t see more than 6 simultaneous streams from your server at one time.
       However, if the streams originated from different ports (or sub domains), this  limitation
       would  not  apply.  When  you  enable  this option with a value (in this case, 30000), the
       streams from the monitors will originate from  30000  plus  the  monitor  ID,  effectively
       overcoming  this  limitation.  Note  that  this also needs additional setup your webserver
       configuration before this can start to work. Please refer to this article on how to  setup
       multi port streaming on Apache.

       MIN_RTP_PORT  - When ZoneMinder communicates with MPEG4 capable cameras using RTP with the
       unicast method it must open ports for the camera  to  connect  back  to  for  control  and
       streaming  purposes.  This  setting specifies the minimum port number that ZoneMinder will
       use. Ordinarily two adjacent ports are used for each camera, one for control  packets  and
       one for data packets. This port should be set to an even number, you may also need to open
       up a hole in your firewall to allow cameras to connect back if you wish to use unicasting.

       MAX_RTP_PORT - When ZoneMinder communicates with MPEG4 capable cameras using RTP with  the
       unicast  method  it  must  open  ports  for  the camera to connect back to for control and
       streaming purposes. This setting specifies the maximum port number  that  ZoneMinder  will
       use.  Ordinarily  two adjacent ports are used for each camera, one for control packets and
       one for data packets. This port should be set to an even number, you may also need to open
       up a hole in your firewall to allow cameras to connect back if you wish to use unicasting.
       You should also ensure that you have opened up at least two ports for  each  monitor  that
       will be connecting to unicasting network cameras.

   Options - Email
       [image]

       OPT_EMAIL  -  In  ZoneMinder you can create event filters that specify whether events that
       match certain criteria should have their details emailed to  you  at  a  designated  email
       address.  This  will  allow you to be notified of events as soon as they occur and also to
       quickly view the events directly. This option specifies whether this functionality  should
       be  available.  The  email  created with this option can be any size and is intended to be
       sent to a regular email reader rather than a mobile device.

       EMAIL_ADDRESS - This option is used to define the email address that any events that match
       the appropriate filters will be sent to.

       EMAIL_SUBJECT  -  This  option is used to define the subject of the email that is sent for
       any events that match the appropriate filters.

       EMAIL_BODY - This option is used to define the content of the email that is sent  for  any
       events that match the appropriate filters.

   Todo
       check if any other tags have been added

                              ┌────────┬──────────────────────────────────┐
                              │Token   │ Description                      │
                              ├────────┼──────────────────────────────────┤
                              │%EI%    │ Id of the event                  │
                              ├────────┼──────────────────────────────────┤
                              │%EN%    │ Name of the event                │
                              ├────────┼──────────────────────────────────┤
                              │%EC%    │ Cause of the event               │
                              ├────────┼──────────────────────────────────┤
                              │%ED%    │ Event description                │
                              ├────────┼──────────────────────────────────┤
                              │%ET%    │ Time of the event                │
                              ├────────┼──────────────────────────────────┤
                              │%EL%    │ Length of the event              │
                              ├────────┼──────────────────────────────────┤
                              │%EF%    │ Number of frames in the event    │
                              ├────────┼──────────────────────────────────┤
                              │%EFA%   │ Number  of  alarm  frames in the │
                              │        │ event                            │
                              ├────────┼──────────────────────────────────┤
                              │%EST%   │ Total score of the event         │
                              ├────────┼──────────────────────────────────┤
                              │%ESA%   │ Average score of the event       │
                              ├────────┼──────────────────────────────────┤
                              │%ESM%   │ Maximum score of the event       │
                              ├────────┼──────────────────────────────────┤
                              │%EP%    │ Path to the event                │
                              ├────────┼──────────────────────────────────┤
                              │%EPS%   │ Path to the event stream         │
                              ├────────┼──────────────────────────────────┤
                              │%EPI%   │ Path to the event images         │
                              └────────┴──────────────────────────────────┘

                              │%EPI1%  │ Path to the first alarmed  event │
                              │        │ image                            │
                              ├────────┼──────────────────────────────────┤
                              │%EPIM%  │ Path  to the (first) event image │
                              │        │ with the highest score           │
                              ├────────┼──────────────────────────────────┤
                              │%EI1%   │ Attach first alarmed event image │
                              ├────────┼──────────────────────────────────┤
                              │%EIM%   │ Attach (first) event image  with │
                              │        │ the highest score                │
                              ├────────┼──────────────────────────────────┤
                              │%EIMOD% │ Attach image of object detected. │
                              │        │ Requires  event  notfn.   server │
                              │        │ setup and machine learning hooks │
                              ├────────┼──────────────────────────────────┤
                              │%EV%    │ Attach event mpeg video          │
                              ├────────┼──────────────────────────────────┤
                              │%MN%    │ Name of the monitor              │
                              ├────────┼──────────────────────────────────┤
                              │%MET%   │ Total  number  of events for the │
                              │        │ monitor                          │
                              ├────────┼──────────────────────────────────┤
                              │%MEH%   │ Number of events for the monitor │
                              │        │ in the last hour                 │
                              ├────────┼──────────────────────────────────┤
                              │%MED%   │ Number of events for the monitor │
                              │        │ in the last day                  │
                              ├────────┼──────────────────────────────────┤
                              │%MEW%   │ Number of events for the monitor │
                              │        │ in the last week                 │
                              ├────────┼──────────────────────────────────┤
                              │%MEM%   │ Number of events for the monitor │
                              │        │ in the last month                │
                              ├────────┼──────────────────────────────────┤
                              │%MEA%   │ Number of  archived  events  for │
                              │        │ the monitor                      │
                              ├────────┼──────────────────────────────────┤
                              │%MP%    │ Path to the monitor window       │
                              ├────────┼──────────────────────────────────┤
                              │%MPS%   │ Path to the monitor stream       │
                              ├────────┼──────────────────────────────────┤
                              │%MPI%   │ Path to the monitor recent image │
                              ├────────┼──────────────────────────────────┤
                              │%FN%    │ Name  of the current filter that │
                              │        │ matched                          │
                              ├────────┼──────────────────────────────────┤
                              │%FP%    │ Path to the current filter  that │
                              │        │ matched                          │
                              ├────────┼──────────────────────────────────┤
                              │%ZP%    │ Path to your ZoneMinder console  │
                              └────────┴──────────────────────────────────┘

       OPT_MESSAGE  - In ZoneMinder you can create event filters that specify whether events that
       match certain criteria should have their details sent to you at a designated short message
       email  address.  This  will allow you to be notified of events as soon as they occur. This
       option specifies whether this functionality should be available. The email created by this
       option will be brief and is intended to be sent to an SMS gateway or a minimal mail reader
       such as a mobile device or phone rather than a regular email reader.

       MESSAGE_ADDRESS - This option is used to define the short message email address  that  any
       events that match the appropriate filters will be sent to.

       MESSAGE_SUBJECT  -  This  option is used to define the subject of the message that is sent
       for any events that match the appropriate filters.

       MESSAGE_BODY - This option is used to define the content of the message that is  sent  for
       any events that match the appropriate filters.

       NEW_MAIL_MODULES  -  Traditionally  ZoneMinder  has  used  the MIME::Entity perl module to
       construct and send notification emails and messages. Some people  have  reported  problems
       with  this  module not being present at all or flexible enough for their needs. If you are
       one of those people this option allows you to select a new mailing method using MIME::Lite
       and  Net::SMTP  instead.  This  method  was  contributed by Ross Melin and should work for
       everyone but has not been extensively tested so currently is not selected by default.

       EMAIL_HOST - If you have chosen SMTP as the method by which to send notification emails or
       messages  then this option allows you to choose which SMTP server to use to send them. The
       default of localhost may work if you have the sendmail, exim or a similar  daemon  running
       however you may wish to enter your ISP’s SMTP mail server here.

       FROM_EMAIL  -  The emails or messages that will be sent to you informing you of events can
       appear to come from a designated email address to help you with  mail  filtering  etc.  An
       address of something like ZoneMinder@your.domain is recommended.

       URL  - The emails or messages that will be sent to you informing you of events can include
       a link to the events themselves for easy viewing. If you intend to use this  feature  then
       set  this  option  to  the url of your installation as it would appear from where you read
       your email, e.g. http://host.your.domain/zm/index.php.

       SSMTP_MAIL - SSMTP is a  lightweight  and  efficient  method  to  send  email.  The  SSMTP
       application  is  not  installed  by default. NEW_MAIL_MODULES must also be enabled. Please
       visit the ZoneMinder SSMTP Wiki page for setup and configuration help.

       SSMTP_PATH - The path to the SSMTP application. If path is not  defined.  Zoneminder  will
       try to determine the path via shell command. Example path: /usr/sbin/ssmtp.

   Options - Upload
       A partial screenshot of the upload options is shown below: [image]

       OPT_UPLOAD  -  In ZoneMinder you can create event filters that specify whether events that
       match certain criteria should be uploaded to a remote server for  archiving.  This  option
       specifies whether this functionality should be available.

       UPLOAD_ARCH_FORMAT  -  Uploaded  events  may be stored in either .tar or .zip format, this
       option specifies which. Note that to use this you  will  need  to  have  the  Archive::Tar
       and/or Archive::Zip perl modules installed.

       UPLOAD_ARCH_COMPRESS  - When the archive files are created they can be compressed. However
       in general since the images are compressed already this saves only  a  minimal  amount  of
       space  versus  utilising  more CPU in their creation. Only enable if you have CPU to waste
       and are limited in disk space on your remote server or bandwidth.

       UPLOAD_ARCH_ANALYSE - When the archive files are created they can contain either just  the
       captured  frames  or  both  the  captured frames and, for frames that caused an alarm, the
       analysed image with the changed area highlighted. This option controls files are included.
       Only  include analysed frames if you have a high bandwidth connection to the remote server
       or if you need help in figuring out what caused an alarm in the first  place  as  archives
       with these files in can be considerably larger.

       UPLOAD_PROTOCOL  -  ZoneMinder  can  upload  events to a remote server using either FTP or
       SFTP. Regular FTP is widely supported but not necessarily very secure whereas SFTP (Secure
       FTP) runs over an ssh connection and so is encrypted and uses regular ssh ports. Note that
       to use this you will need  to  have  the  appropriate  perl  module,  either  Net::FTP  or
       Net::SFTP installed depending on your choice.

       UPLOAD_HOST  -  You  can  use  filters to instruct ZoneMinder to upload events to a remote
       server. This option indicates the name, or ip address, of the server to use.

       UPLOAD_PORT - You can use filters to instruct ZoneMinder to  upload  events  to  a  remote
       server.  If  you  are  using  the  SFTP  protocol then this option allows you to specify a
       particular port to use for connection. If this option is left blank then the default, port
       22, is used. This option is ignored for FTP uploads.

       UPLOAD_USER  -  You  can  use  filters to instruct ZoneMinder to upload events to a remote
       server. This option indicates the username that  ZoneMinder  should  use  to  log  in  for
       transfer.

       UPLOAD_PASS  -  You  can  use  filters to instruct ZoneMinder to upload events to a remote
       server. This option indicates the password that  ZoneMinder  should  use  to  log  in  for
       transfer.  If  you  are using certificate based logins for SFTP servers you can leave this
       option blank.

       UPLOAD_LOC_DIR - You can use filters to instruct ZoneMinder to upload events to  a  remote
       server. This option indicates the local directory that ZoneMinder should use for temporary
       upload files. These are files that are created from events, uploaded and then deleted.

       UPLOAD_REM_DIR - You can use filters to instruct ZoneMinder to upload events to  a  remote
       server.  This  option  indicates the remote directory that ZoneMinder should use to upload
       event files to.

       UPLOAD_TIMEOUT - You can use filters to instruct ZoneMinder to upload events to  a  remote
       server.  This  option indicates the maximum inactivity timeout (in seconds) that should be
       tolerated before ZoneMinder determines that the transfer has failed and  closes  down  the
       connection.

       UPLOAD_STRICT  -  You can require SFTP uploads to verify the host key of the remote server
       for protection against man-in-the-middle attacks. You will need to add the server’s key to
       the  known_hosts  file.  On  most systems, this will be ~/.ssh/known_hosts, where ~ is the
       home directory of the web server running ZoneMinder.

       UPLOAD_FTP_PASSIVE - You can use filters to instruct ZoneMinder  to  upload  events  to  a
       remote  ftp  server.  This  option  indicates that ftp transfers should be done in passive
       mode. This uses a single connection for all ftp activity and, whilst  slower  than  active
       transfers, is more robust and likely to work from behind filewalls. This option is ignored
       for SFTP transfers.

       UPLOAD_DEBUG - You can use filters to instruct ZoneMinder to upload  events  to  a  remote
       server.  If you are having (or expecting) troubles with uploading events then setting this
       to ‘yes’ permits additional information to be generated by the underlying transfer modules
       and included in the logs.

   Options - X10
       [image]

       OPT_X10  - If you have an X10 Home Automation setup in your home you can use ZoneMinder to
       initiate or  react  to  X10  signals  if  your  computer  has  the  appropriate  interface
       controller.  This  option  indicates  whether X10 options will be available in the browser
       client.

       X10_DEVICE - If you have an X10 controller device (e.g. XM10U) connected to your  computer
       this  option  details  which  port  it  is connected on, the default of /dev/ttyS0 maps to
       serial or com port 1.

       X10_HOUSE_CODE - X10 devices are grouped together by identifying them as all belonging  to
       one  House  Code. This option details what that is. It should be a single letter between A
       and P.

       X10_DB_RELOAD_INTERVAL - The zmx10 daemon periodically checks the  database  to  find  out
       what  X10  events  trigger,  or result from, alarms. This option determines how frequently
       this check occurs, unless you change this area frequently  this  can  be  a  fairly  large
       value.

   Options - High, Medium and Low B/W
       There  are a number of options that are grouped into bandwidth categories, this allows you
       to configure the ZoneMinder client to work optimally over the various access  methods  you
       might  to access the client. You may want to use different modes depending on your network
       to preserve bandwidth.

       A partial screenshot is shown below: [image]

       The following options are available in H, M and L options. These  3  groups  control  what
       happens  when  the  client  is  running  in  ‘high’,  ‘medium’  and  ‘low’  bandwidth mode
       respectively. In most cases the default values will be suitable as a starting point.

       High - You should set these options for when accessing the ZoneMinder client over a  local
       network or high speed link.

       Medium  -   You  should  set these options for when accessing the ZoneMinder client over a
       slower cable or DSL link.

       Slow - You should set these options for when  accessing  Zoneminder  client  over  a  slow
       network link.

       WEB_H_REFRESH_MAIN,  WEB_M_REFRESH_MAIN,  WEB_L_REFRESH_MAIN  - How often (in seconds) the
       main console window should refresh itself. The main console window lists a general  status
       and  the  event  totals  for  all  monitors.  This is not a trivial task and should not be
       repeated too frequently or it may affect the performance of the rest of the system.

       WEB_H_REFRESH_CYCLE, WEB_M_REFRESH_CYCLE, WEB_L_REFRESH_CYCLE - How often (in seconds) the
       cycle  watch  window  swaps  to  the  next  monitor. The cycle watch window is a method of
       continuously cycling between images from all of your monitors. This option determines  how
       often to refresh with a new image.

       WEB_H_REFRESH_IMAGE, WEB_M_REFRESH_IMAGE, WEB_L_REFRESH_IMAGE - How often (in seconds) the
       watched image is refreshed (if not streaming). The live  images  from  a  monitor  can  be
       viewed  in either streamed or stills mode. This option determines how often a stills image
       is refreshed, it has no effect if streaming is selected.

       WEB_H_REFRESH_STATUS, WEB_M_REFRESH_STATUS, WEB_L_REFRESH_STATUS - How often (in  seconds)
       the  status refreshes itself in the watch window. The monitor window is actually made from
       several frames. The one in the middle merely contains a  monitor  status  which  needs  to
       refresh  fairly  frequently  to  give  a  true  indication.  This  option  determines that
       frequency.

       WEB_H_REFRESH_EVENTS, WEB_M_REFRESH_EVENTS, WEB_L_REFRESH_EVENTS - How often (in  seconds)
       the  event  listing  is refreshed in the watch window. The monitor window is actually made
       from several frames. The lower framme contains a listing of the last few events  for  easy
       access. This option determines how often this is refreshed.

       WEB_H_CAN_STREAM,  WEB_M_CAN_STREAM,  WEB_L_CAN_STREAM - If you know that your browser can
       handle image streams of the  type  ‘multipart/x-mixed-replace’  but  ZoneMinder  does  not
       detect  this correctly you can set this option to ensure that the stream is delivered with
       or without the use of the Cambozola plugin. Selecting ‘yes’ will tell ZoneMinder that your
       browser can handle the streams nativ

       WEB_H_STREAM_METHOD,   WEB_M_STREAM_METHOD,   WEB_H_STREAM_METHOD   -  ZoneMinder  can  be
       configured to use either mpeg encoded video or a series or still jpeg images when  sending
       video  streams.  This  option  defines which is used. If you choose mpeg you should ensure
       that you have the appropriate plugins available on your browser whereas choosing jpeg will
       work natively on Mozilla and related browsers and with a Java applet on Internet Explorer

       WEB_H_DEFAULT_SCALE,  WEB_M_DEFAULT_SCALE,  WEB_L_DEFAULT_SCALE - Normally ZoneMinder will
       display ‘live’ or ‘event’ streams in their native size. However if you have monitors  with
       large  dimensions  or  a  slow  link you may prefer to reduce this size, alternatively for
       small monitors you can enlarge it. This options lets you specify what the default  scaling
       factor  will be. It is expressed as a percentage so 100 is normal size, 200 is double size
       etc.

       WEB_H_DEFAULT_RATE, WEB_M_DEFAULT_RATE,  WEB_L_DEFAULT_RATE  -  Normally  ZoneMinder  will
       display  ‘event’  streams  at  their  native rate, i.e. as close to real-time as possible.
       However if you have long events it is often convenient to replay them at a faster rate for
       review. This option lets you specify what the default replay rate will be. It is expressed
       as a percentage so 100 is normal rate, 200 is double speed etc.

       WEB_H_VIDEO_BITRATE, WEB_M_VIDEO_BITRATE, WEB_L_VIDEO_BITRATE - When encoding  real  video
       via  the  ffmpeg  library  a  bit  rate  can be specified which roughly corresponds to the
       available bandwidth used for  the  stream.  This  setting  effectively  corresponds  to  a
       ‘quality’  setting for the video. A low value will result in a blocky image whereas a high
       value will produce a clearer view. Note that this setting does not control the frame  rate
       of  the  video  however the quality of the video produced is affected both by this setting
       and the frame rate that the video is produced at. A higher frame rate at a particular  bit
       rate result in individual frames being at a lower quality.

       WEB_H_VIDEO_MAXFPS, WEB_M_VIDEO_MAXFPS, WEB_L_VIDEO_MAXFPS - When using streamed video the
       main control is the bitrate which determines how much data can be transmitted.  However  a
       lower bitrate at high frame rates results in a lower quality image. This option allows you
       to limit the maximum frame rate to ensure that video quality is maintained. An  additional
       advantage  is  that  encoding video at high frame rates is a processor intensive task when
       for the most part a very high frame rate offers little perceptible  improvement  over  one
       that has a more manageable resource requirement. Note, this option is implemented as a cap
       beyond which binary reduction takes place. So if you have a device capturing at 15fps  and
       set this option to 10fps then the video is not produced at 10fps, but rather at 7.5fps (15
       divided by 2) as the final frame rate must be the original divided by a power of 2.

       WEB_H_SCALE_THUMBS, WEB_M_SCALE_THUMBS, WEB_L_SCALE_THUMBS - If unset, this  option  sends
       the  whole image to the browser which resizes it in the window. If set the image is scaled
       down on the server before sending  a  reduced  size  image  to  the  browser  to  conserve
       bandwidth  at the cost of cpu on the server. Note that ZM can only perform the resizing if
       the appropriate PHP graphics functionality is installed. This is usually available in  the
       php-gd package.

       WEB_H_EVENTS_VIEW,  WEB_M_EVENTS_VIEW,  WEB_L_EVENTS_VIEW - Stored events can be viewed in
       either an events list format or in a timeline based one. This option sets the default view
       that will be used. Choosing one view here does not prevent the other view being used as it
       will always be selectable from whichever view is currently being used.

       WEB_H_SHOW_PROGRESS, WEB_M_SHOW_PROGRESS, WEB_L_SHOW_PROGRESS -  When  viewing  events  an
       event  navigation  panel and progress bar is shown below the event itself. This allows you
       to jump to specific points in the event, but can can also dynamically  update  to  display
       the  current  progress  of  the  event replay itself. This progress is calculated from the
       actual event duration and is not directly linked to  the  replay  itself,  so  on  limited
       bandwidth  connections  may be out of step with the replay. This option allows you to turn
       off the progress display, whilst still keeping  the  navigation  aspect,  where  bandwidth
       prevents it functioning effectively.

       WEB_H_AJAX_TIMEOUT,  WEB_M_AJAX_TIMEOUT,  WEB_L_AJAX_TIMEOUT  -  The newer versions of the
       live feed and event views use Ajax to request information from the server and populate the
       views  dynamically.  This  option  allows you to specify a timeout if required after which
       requests are abandoned. A timeout may be necessary if requests would overwise hang such as
       on  a  slow  connection.  This  would tend to consume a lot of browser memory and make the
       interface unresponsive. Ordinarily no requests should timeout so this  setting  should  be
       set  to  a value greater than the slowest expected response. This value is in milliseconds
       but if set to zero then no timeout will be used.

   Options - Users
       [image]

       In this section you will see a list of the current users defined on the  system.  You  can
       also  add  or  delete  users from here. It is recommended you do not delete the admin user
       unless you have created another fully privileged user to take over  the  same  role.  Each
       user  is  defined with a name and password (which is hidden) as well as an enabled setting
       which you can use to temporarily enable or disable users, for example  a  guest  user  for
       limited time access. As well as that there is a language setting that allows you to define
       user specific languages. Setting a  language  here  that  is  different  than  the  system
       language  will mean that when that user logs in they will have the web interface presented
       in their own language rather than the system default, if it is available.

       This screen allows you  to  configure  various  permissions  on  a  per  user  basis.  The
       permissions as of today are defined as follows:

       • Streams  - None: the user has no access to view live streams from the defined monitors -
         View: the user has access to only view live streams from the defined  monitors  -  Edit:
         the user has access to edit live streams from the defined monitors

       • Events  -  These  permissions  relate  to  the  ability  to view events from the defined
         monitors. The permission levels are the same as the  Streams  permissions,  except  that
         they apply to recorded events

       • Control  - These permissions relate to the ability to control Pan/Tilt/Zoom (PTZ) of the
         defined monitors. The permission levels are the same as the Streams permissions,  except
         that they apply to PTZ

       • Monitors  -  specifies  whether  a  user can see the current monitor settings and change
         them. The permissions levels are the same as the Streams permissions, except  that  they
         apply to monitor settings

       • Groups  -  specifies  whether  a  user  can  see  monitor  groups  and  change them. The
         permissions levels are the same as the Streams permissions, except that  they  apply  to
         groups

       • System  -  Determines  whether a user can view or modify the system settings as a whole,
         such as options and users or controlling the running of  the  system  as  a  whole.  The
         permissions  levels  are  the same as the Streams permissions, except that they apply to
         groups.

         NOTE:
            if you are using zmNinja, users are required to have ‘View’ access to system  because
            multi-server information is only available as part of this permission

       • Bandwidth - Specifies the maximum bandwidth that this user can configure (Low, Medium or
         High)

       • API enabled - Specifies if the ZoneMinder API is enabled for this user (needs to be  on,
         if you are using a mobile app such as zmNinja)

       Finally,  you  can  specify  a  list  of monitors this user is allowed to access using the
       ‘Restriced  Monitors’  list.  You  can  select   multiple   monitors   by   shift+click(or
       command+click)  on multiple monitors. If a user with ‘Monitors’ edit privileges is limited
       to specific monitors here they will not be able to add or delete monitors but only  change
       the  details  of  those  they  have  access to. If a user has ‘System’ privileges then the
       ‘Monitors Ids’ setting is ignored and has no effect.

       Here is an example of a restricted user, for example: [image]

       This user “home” is enabled, can view live streams and events, but  only  from  “DoorBell”
       and “DeckCamera”. This user also cannot control PTZ.

   Camera Control
       ZoneMinder  provides  the  facility  to control cameras from the web interface and to some
       extent automatically. Pan/Tilt/Zoom (PTZ) cameras have a wide range  of  capabilities  and
       use  a  large  number  of  different protocols making any kind of generic control solution
       potentially very difficult. To address this ZoneMinder uses  two  key  approaches  to  get
       around this problem.

       Definition of Capabilities
              For  each  camera  model you use, an entry in the camera capabilities table must be
              created. These indicate what functions the camera  supports  and  ensure  that  the
              interface  presents  only  those capabilities that the camera supports. There are a
              very large number of capabilities that may be supported and it  is  very  important
              that  the entries in this table reflect the actual abilities of the camera. A small
              number of example capabilities are included in ZoneMinder, these can  be  used  ‘as
              is’ or modified.

       Control Scripts
              ZoneMinder  itself  does  not  generally  provide  the  ability to send commands to
              cameras or receive responses. What it does is mediate motion requests from the  web
              interface  into  a standard set of commands which are passed to a script defined in
              the control capability. Example scripts are provided in ZoneMinder which support  a
              number  of  serial  or network protocols but it is likely that for many cameras new
              scripts will have to be created. These can be modelled on the example ones,  or  if
              control  commands  already  exist from other applications, then the script can just
              act as a ‘glue’ layer between ZoneMinder and those commands.

       It should be emphasised that the control and capability elements  of  ZoneMinder  are  not
       intended  to be able to support every camera out of the box. Some degree of development is
       likely to be required for many cameras.

   Controlling Monitors
       If you have defined your system as having controllable monitors and you are looking  at  a
       monitor  that is configured for control, then clicking on the ‘Control’ link along the top
       of the window will change the short event listing area to a control area. The capabilities
       you have defined earlier determine exactly what is displayed in this window. Generally you
       will have a Pan/Tilt control area along with one or subsidiary areas such as zoom or focus
       control  to the side. If you have preset support then these will be near the bottom of the
       window. The normal method of controlling the monitor is by  clicking  on  the  appropriate
       graphics  which  then send a command via the control script to the camera itself. This may
       sometimes take a noticeable delay before the camera responds.

       It is usually the case that the control arrows are sensitive to where you click  on  them.
       If  you  have  a camera that allows different speeds to be used for panning or zooming etc
       then clicking near the point of the arrow will invoke the  faster  speed  whilst  clicking
       near  the  base  of  the  arrow will be slower. If you have defined continuous motion then
       ongoing activities can be stopped by clicking on the area between the arrows,  which  will
       either  be  a  graphic  in the case of pan/tilt controls or a word in the case of zoom and
       focus controls etc.

       Certain control capabilities such as mapped motion allow direct control by clicking on the
       image  itself  when  used in browsers which support streamed images directly. Used in this
       way you can just click on the area of the image that interests you  and  the  camera  will
       centre  on  that  spot. You can also use direct image control for relative motion when the
       area of the image you click on defines the direction and the distance away from the centre
       of  the  image  determines  the speed. As it is not always very easy to estimate direction
       near the centre of the image, the active area does not start until a short  distance  away
       from the centre, resulting in a ‘dead’ zone in the middle of the image.

   Control Flow
       Having  a basic understanding of how camera control works in ZoneMinder will go a long way
       in debugging issues in the future. It is important  to  note  that  many  of  the  ‘camera
       control’  scripts  are  user  contributed and it is entirely possible that they break in a
       future version upgrade.

       • ZoneMinder relies on ‘control protocols’ for specific  camera  models.  These  ‘control’
         protocols  are nothing but perl packages located in /usr/share/perl5/ZoneMinder/Control/
         (in Ubuntu distributions) that are invoked by ZoneMinder when you invoke a PTZ operation

       • When you associate a ‘protocol’ for PTZ  for  a  camera,  you  are  effectively  letting
         ZoneMinder  know  where  to locate the perl file that will eventually control the camera
         movement

       • Let’s for example, assume that you are  configuring  a  Foscam  9831W  camera  and  have
         associated  the  ‘9831w’ protocol to that camara. This basically means when you move the
         camera  via  ZoneMinder,  it   will   pass   on   the   movements   to   FI9831w.pm   in
         /usr/share/perl5/ZoneMinder/Control/

       • ZoneMinder  also  maintains protocol configuration parameters in a table called Controls
         in the DB. This table is used to store  parameters  like  whether  the  camera  supports
         continuous move, zoom etc.

       • The Controls table is used by ZoneMinder to build its PTZ web interface. For example, an
         FI9831W camera does not support Zoom –> so when you open the PTZ interface of ZoneMinder
         via  the  Web  Console  and  navigate to the FI9831W camera, the Zoom option will not be
         shown. It knows not to show this because the Control table entry for  FI9831W  specifies
         it    does   not   support   Zoom.   Note   that   you   edit   these   parameters   via
         Source->Control->Control Type->Edit in the web console

       • If you ever look at any of the control protocol files, you will notice it has  functions
         like  moveRelUp  or  moveConLeft  etc.  ->  these  are the functions that eventually get
         invoked to move the camera around and it is expected  that  contributors  who  implement
         missing  camera  profiles  fill  in these functions with the appropriate camera specific
         commands. This way, the core ZoneMinder  code  does  not  need  to  worry  about  camera
         specific  commands.  All  it  needs  to know is the features of a camera and accordinfly
         invoke abstract commands in the protocol perl file and it is the responsibility  of  the
         perl  file  for  that  camera to implement the specifics. So, if you are facing problems
         with PTZ not working, these protocol files are what you should be debugging.

   Control Capabilities
       If you have a camera that supports PTZ controls and wish to use it  with  ZoneMinder  then
       the first thing you need to do is ensure that it has an accurate entry in the capabilities
       table. To do this you need to go to the Control tab of the  Monitor  configuration  dialog
       and select ‘Edit’ where it is listed by the Control Type selection box. This will bring up
       a new window which lists, with a brief summary, the  existing  capabilities.  To  edit  an
       existing  capability  to  modify  select  the Id or Name of the capability in question, or
       click on the Add button to add a new control capability. Either of these  approaches  will
       create a new window, in familiar style, with tabs along the top and forms fields below. In
       the case of the capabilities table there are a large number of settings and tabs, the mean
       and use of these are briefly explained below.

   Main Tab
       Name   This  is  the  name  of  the control capability, it will usually make sense to name
              capabilities after the camera model or protocol being used.

       Type   Whether the capability uses a local (usually serial) or network control protocol.

       Command
              This is the full path to a script or application that will map the standard set  of
              ZoneMinder control commands to equivalent control protocol command. This may be one
              of the shipped example zmcontrol-*.pl scripts or something else entirely.

       Can Wake
              This is the first of the actual capability definitions. Checking this box indicates
              that a protocol command exists to wake up the camera from a sleeping state.

       Can Sleep
              The camera can be put to sleep.

       Can Reset
              The camera can be reset to a previously defined state.

   Move Tab
       Can Move
              The camera is able move, i.e. pan or tilt.

       Can Move Diagonally
              The  camera  can  move  diagonally.  Some  devices  can  move  only  vertically  or
              horizontally at a time.

       Can Move Mapped
              The camera is able internally map a point on an image to a precise degree of motion
              to centre that point in the image.

       Can Move Absolute
              The camera can move to an absolute location.

       Can Move Relative
              The camera can more to a relative location, e.g. 7 point left or up.

       Can Move Continuous
              The  camera  can move continuously in a defined direction until told to stop or the
              movement limits are reached, e.g. left.

   Pan Tab
       Can Pan
              The camera can pan, or move horizontally.

       Min/Max Pan Range
              If the camera supports  absolute  motion  this  is  the  minimum  and  maximum  pan
              co-ordinates that may be specified, e.g. -100 to 100.

       Min/Man Pan Step
              If  the  camera supports relative motion, this is the minimum and maximum amount of
              movement that can be specified.

       Has Pan Speed
              The camera supports specification of pan speeds.

       Min/Max Pan Speed
              The minimum and maximum pan speed supported.

       Has Turbo Pan
              The camera supports an additional turbo pan speed.

       Turbo Pan Speed
              The actual turbo pan speed.

   Tilt Tab
       Definition of Tilt capabilities, fields as for ‘Pan’ tab.

   Zoom Tab
       Can Zoom
              The camera can zoom.

       Can Zoom Absolute
              The camera can zoom to an absolute position.

       Can Zoom Relative
              The camera can zoom to a relative position.

       Can Zoom Continuous
              The camera can zoom continuously in or out until told to stop or  the  zoom  limits
              are reached.

       Min/Max Zoom Range
              If  the  camera supports absolute zoom this is the minimum and maximum zoom amounts
              that may be specified.

       Min/Man Zoom Step
              If the camera supports relative zoom, this is the minimum  and  maximum  amount  of
              zoom change that can be specified.

       Has Zoom Speed
              The camera supports specification of zoom speed.

       Min/Max Zoom Speed
              The minimum and maximum zoom speed supported.

   Focus Tab
       Definition  of  Focus  capabilities,  fields  as  for  ‘Zoom’  tab, but with the following
       additional capability.

       Can Auto Focus
              The camera can focus automatically.

   White Tab
       Definition of White Balance capabilities, fields as for ‘Focus’ tab.

   Iris Tab
       Definition of Iris Control capabilities, fields as for ‘Focus’ tab.

   Presets Tab
       Has Presets
              The camera supports preset positions.

       Num Presets
              How many presets the camera supports. If the  camera  supports  a  huge  number  of
              presets then it makes sense to specify a more reasonable number here, 20 or less is
              recommended.

       Has Home Preset
              The camera has a defined ‘home’ position, usually in the mid point of its range.

       Can Set Presets
              The camera supports setting preset locations via its control protocol.

   Control Scripts
       The second key element  to  controlling  cameras  with  ZoneMinder  is  ensuring  that  an
       appropriate control script or application is present. A small number of sample scripts are
       included with ZoneMinder and can be used directly or as the basis for development. Control
       scripts  are  run  atomically,  that  is  to  say  that  one requested action from the web
       interface results in one execution of the script and no state information  is  maintained.
       If  your  protocol  requires state information to be preserved then you should ensure that
       your scripts do this as ZoneMinder has no concept of the state of the  camera  in  control
       terms.

       If  you  are  writing  a  new  control script then you need to ensure that it supports the
       parameters that ZoneMinder will pass to it. If you already have  scripts  or  applications
       that  control your cameras, the ZoneMinder control script will just act as glue to convert
       the parameters passed into a form that your existing application understands. If  you  are
       writing  a  script  to support a new protocol then you will need to convert the parameters
       passed into the script to equivalent protocol commands. If you have carefully defined your
       control  capabilities  above then you should only expect commands that correspond to those
       capabilities.

       The standard set of parameters passed to control scripts is defined below,
          –device=<device> : This is the control device from the monitor definition. Absent if no
          device  is  specified.   —  address=<address>  :  This  is the control address from the
          monitor definition. This will usually be a hostname or ip address for  network  cameras
          or a simple numeric camera id for other cameras.
          –autostop=<timeout>  : This indicates whether an automatic timeout should be applied to
          ‘’’stop’’’ the given command. It will only be included for  ‘’’continuous’’’  commands,
          as  listed  below,  and  will  be a timeout in decimal seconds, probably fractional.  —
          command=<command> : This specifies the command that the script  should  execute.  Valid
          commands are given below.
          –xcoord=<x>, –ycoord=<y> : This specifies the x and/or y coordinates for commands which
          require them. These will normally be absolute or mapped commands.   —  width=<width>’’,
          ‘’–height=<height>  :  This  specifies  the  width and height of the current image, for
          mapped motion commands where the coordinates values passed must have a context.
          –speed=<speed> : This specifies the speed that the command should use, if  appropriate.
          —  panspeed=<speed>’’,  ‘’–tiltspeed=<speed> : This indicates the specific pan and tilt
          speeds for diagonal movements which may allow a different motion  rate  for  horizontal
          and vertical components.
          –step=<step>  :  This  specifies  the  amount of motion that the command should use, if
          appropriate.  Normally  used  for  relative   commands   only.    —   panstep=<step>’’,
          ‘’–tiltstep=<step>  :  This  indicates  the  specific  pan  and tilt steps for diagonal
          movements which may allow a different amount of  motion  for  horizontal  and  vertical
          components.
          –preset=<preset>  :  This specifies the particular preset that relevant commands should
          operate on.

       The command option listed above may take one of the following commands as a parameter.

       wake   Wake the camera.

       sleep  Send the camera to sleep.

       reset  Reset the camera.

       move_map
              Move mapped to a specified location on the image.

       move_pseudo_map
              As move_map above. Pseudo-mapped motion can be  used  when  mapped  motion  is  not
              supported  but  relative  motion  is  in  which  case  mapped motion can be roughly
              approximated by careful calibration.

       move_abs_<direction>
              Move to a specified absolute location. The direction element gives a  hint  to  the
              direction  to  go  but  can  be omitted. If present it will be one of “up”, “down”,
              “left”, “right”, “upleft”, “upright”, “downleft” or “downright”.

       move_rel_<direction>
              Move a specified amount in the given direction.

       move_con_<direction>
              Move continuously in the given direction until told to stop.

       move_stop
              Stop any motion which may be in progress.

       zoom_abs_<direction>
              Zoom to a specified absolute zoom position. The direction element gives a  hint  to
              the  direction  to  go  but  can be omitted. If present it will be one of “tele” or
              “wide”.

       zoom_rel_<direction>
              Zoom a specified amount in the given direction.

       zoom_con_<direction>
              Zoom continuously in the given direction until told to stop.

       zoom_stop
              Stop any zooming which may be in progress.

       focus_auto
              Set focusing to be automatic.

       focus_man
              Set focusing to be manual.

       focus_abs_<direction>
              Focus to a specified absolute focus position. The direction element gives a hint to
              the  direction  to  go  but  can be omitted. If present it will be one of “near” or
              “far”.

       focus_rel_<direction>
              Focus a specified amount in the given direction.

       focus_con_<direction>
              Focus continuously in the given direction until told to stop.

       focus_stop
              Stop any focusing which may be in progress.

       white_<subcommand>
              As per the focus commands, except that direction may be “in” or “out”.

       iris_<subcommand>
              As per the focus commands, except that direction may be “open” or “close”.

       preset_set
              Set the given preset to the current location.

       preset_goto
              Move to the given preset.

       preset_home
              Move to the “home” preset.

   Mobile Devices
       Here are some options for using ZoneMinder on Mobile devices:

   Third party mobile clientszmNinja (source code, needs APIs to be installed to work)

                • Available in App Store, Play Store and for Desktops - website

   Using the existing web console
       • You can directly use the ZoneMinder interface by launching a browser and  going  to  the
         ZoneMinder server just like you do on the Desktop

   Discontinued clients
       The following are a list of clients that do not work and have not been updated:

       • eyeZM

       • zmView

   Logging
       NOTE:
          Understanding  how logging works in ZoneMinder is key to being able to isolate/pinpoint
          issues well. Please refer to Options - Logging to read about how to customize logging.

       Most components of ZoneMinder can emit informational, warning, error and debug messages in
       a  standard  format. These messages can be logged in one or more locations. By default all
       messages produced by scripts are logged in <script name>.log files which are placed in the
       directory defined by the ZM_PATH_LOGS configuration variable. This is initially defined as
       /var/log/zm (on debian based systems) though it can be overridden to a  custom  path  (the
       path  is  usually  defined in /etc/zm/conf.d/01-system-paths.conf, but to override it, you
       should create your own config file, not overwrite this file). So for example, the  zmdc.pl
       script will output messages to /var/log/zmdc.log, an example of these messages is:

          10/24/2019 08:01:19.291513 zmdc[6414].INF [ZMServer:408] [Starting pending process, zma -m 2]
          10/24/2019 08:01:19.296575 zmdc[6414].INF [ZMServer:408] ['zma -m 2' starting at 19/10/24 08:01:19, pid = 15740]
          10/24/2019 08:01:19.296927 zmdc[15740].INF [ZMServer:408] ['zma -m 2' started at 19/10/24 08:01:19]

       where  the  first  part  refers to the date and time of the entry, the next section is the
       name (or an abbreviated version) of the script, followed  by  the  process  id  in  square
       brackets,  a  severity  code  (INF, WAR, ERR or DBG) and the debug text. If you change the
       location of the log directory, ensure it refers to an existing  directory  which  the  web
       user  has  permissions to write to. Also ensure that no logs are present in that directory
       the web user does not have permission to open. This can happen  if  you  run  commands  or
       scripts  as  the  root  user  for  testing  at  some point. If this occurs then subsequent
       non-privileged runs will fails due to being unable to open the log files.

       As well as specific script logging above, information,  warning  and  error  messages  are
       logged  via  the  system syslog service. This is a standard component on Linux systems and
       allows logging of all sorts of messages in a standard way and using a standard format.  On
       most  systems, unless otherwise configured, messages produced by ZoneMinder will go to the
       /var/log/messages or /var/log/syslog file. On  some  distributions  they  may  end  up  in
       another file, but usually still in /var/log. Messages in this file are similar to those in
       the script log files but differ slightly. For example the above event in  the  system  log
       file looks like:

          Jan  3 13:46:00 shuttle52 zmpkg[11148]: INF [Command: start]

       where  you can see that the date is formatted differently (and only to 1 second precision)
       and there is an additional field for the hostname (as syslog can operate over a  network).
       As  well  as  ZoneMinder  entries in this file you may also see entries from various other
       system components. You should ensure that  your  syslogd  daemon  is  running  for  syslog
       messages to be correctly handled.

   Customizing logging properly in ZoneMinder
   Other Notes
       A  number  of  users  have  asked how to suppress or redirect ZoneMinder messages that are
       written to this file. This most often occurs due to not wanting other system  messages  to
       be  overwhelmed  and obscured by the ZoneMinder produced ones (which can be quite frequent
       by default). In order to  control  syslog  messages  you  need  to  locate  and  edit  the
       syslog.conf  file  on  your  system.  This  will often be in the /etc directory. This file
       allows configuration of syslog so that certain classes  and  categories  of  messages  are
       routed  to  different  files or highlighted to a console, or just ignored. Full details of
       the format of this file is outside the scope of this document  (typing  ‘man  syslog.conf’
       will  give  you  more  information)  but  the  most  often  requested  changes are easy to
       implement.

       The syslog service uses the concept of priorities and facilities where the  former  refers
       to  the  importance  of  the message and the latter refers to that part of the system from
       which it originated. Standard priorities include ‘info’, ‘warning’, ‘err’ and ‘debug’  and
       ZoneMinder  uses  these  priorities  when  generating  the corresponding class of message.
       Standard facilities include ‘mail’, ‘cron’ and ‘security’ etc but as well this, there  are
       eight  ‘local’  facilities  that  can  be  used  by  machine  specific message generators.
       ZoneMinder produces it’s messages via the ‘local1’ facility.

       So armed with the knowledge of the priority and facility of  a  message,  the  syslog.conf
       file can be amended to handle messages however you like.

       So  to  ensure  that  all  ZoneMinder  messages  go to a specific log file you can add the
       following line near the top of your syslog.conf file:

          # Save ZoneMinder messages to zm.log
          local1.*                        /var/log/zm/zm.log

       which will ensure that all messages produced with the local1 facility are  routed  to  fhe
       /var/log/zm/zm.log  file.  However  this does not necessarily prevent them also going into
       the standard system log. To do this you will need to modify the line that determines which
       messages are logged to this file. This may look something like:

          # Log anything (except mail) of level info or higher.
          # Don't log private authentication messages!
          *.info;mail.none;news.none;authpriv.none;cron.none      /var/log/messages

       by  default.  To  remove ZoneMinder messages altogether from this file you can modify this
       line to look like:

          *.info;local1.!*;mail.none;news.none;authpriv.none;cron.none     /var/log/messages

       which instructs syslog to ignore any messages from the local1  facility.  If  however  you
       still want warnings and errors to occur in the system log file, you could change it to:

          *.info;local1.!*;local1.warning;mail.none;news.none;authpriv.none;cron.none     /var/log/messages

       which follows the ignore instruction with a further one to indicate that any messages with
       a facility of local1 and a priority of warning or above should still go into the file.

       These recipes are just examples of how you can modify the logging  to  suit  your  system,
       there  are  a  lot  of  other  modifications you could make. If you do make any changes to
       syslog.conf you should ensure you restart the syslogd process or send it a HUP  signal  to
       force it to reread its configuration file otherwise your changes will be ignored.

       The  discussion  of  logging above began by describing how scripts produce error and debug
       messages. The way  that  the  binaries  work  is  slightly  different.  Binaries  generate
       information,  warning  and  error messages using syslog in exactly the same way as scripts
       and these  messages  will  be  handled  identically.  However  debug  output  is  somewhat
       different.  For  the scripts, if you want to enable debug you will need to edit the script
       file itself and change the DBG_LEVEL constant to have a value of 1. This will  then  cause
       debug  messages  to  be  written  to  the  <script>.log file as well as the more important
       messages. Debug messages however are not routed via syslog. Scripts  currently  only  have
       one level of debug so this will cause any and all debug messages to be generated. Binaries
       work slightly differently and while you can edit the call to zmDbgInit that is present  in
       every  binary’s  ‘main’ function to update the initial value of the debug level, there are
       easier ways.

       The simplest way of collecting debug output is to click on the Options link from the  main
       ZoneMinder  console  view  and  then  go to the Debug tab. There you will find a number of
       debug options. The first thing you should do is ensure that the ZM_EXTRA_DEBUG setting  is
       switched  on.  This  enables  debug generally. The next thing you need to do is select the
       debug target, level and destination file using the relevant options. Click on the  ‘?’  by
       each option for more information about valid settings. You will need to restart ZoneMinder
       as a whole or at least the component in question for logging to take effect. When you have
       finished debugging you should ensure you switch debug off by unchecking the ZM_EXTRA_DEBUG
       option and restarting ZoneMinder. You can leave the other options as you like as they  are
       ignored if the master debug option is off.

       Once you have debug being logged you can modify the level by sending USR1 and USR2 signals
       to the relevant binary (or binaries) to increase or decrease  the  level  of  debug  being
       emitted  with  immediate  effect.  This  modification  will not persist if the binary gets
       restarted however.

       If you wish to run a binary directly from the command line to test specific  functionality
       or scenarios, you can set the ZM_DBG_LEVEL and ZM_DBG_LOG environment variables to set the
       level and log file of the debug you wish to see, and the ZM_DBG_PRINT environment variable
       to 1 to output the debug directly to your terminal.

       All  ZoneMinder  logs  can  now be rotated by logrotate. A sample logrotate config file is
       shown below:

          /var/log/zm/*.log {
              missingok
              notifempty
              sharedscripts
              postrotate
                  /usr/local/bin/zmpkg.pl logrot 2> /dev/null > /dev/null || true
              endscript
          }

   Configuration Files
       This section describes configuration files that ZoneMinder uses beyond the various Web  UI
       options.

   System Path Configurations
       At  one  point of time, ZoneMinder stored various system path configurations under the Web
       UI  (Options->Paths).  This  was  removed  a  few  versions  ago  and  now  resides  in  a
       configuration file. The motivation for this change can be read in this discussion.

       Typically, path configurations now reside in /etc/zm.

       Here is an example of the file hierarchy:

          /etc/zm
          ├── conf.d
          │   ├── 01-system-paths.conf
          │   ├── 02-multiserver.conf
          |   ├── 03-custom.conf #optional
          │   └── README
          ├── objectconfig.ini # optional
          ├── zm.conf
          └── zmeventnotification.ini #optional

       The roles of the files are as follows:

       • zm.conf contains various base configuration entries. You should not edit this file as it
         may be overwritten on an upgrade.

       • zmeventnotification.ini is only present if  you  have  installed  the  ZoneMinder  Event
         Notification Server.

       • objectconfig.ini  is  only  present if you have installed the machine learning hooks for
         the Event Notification Server.

       • conf.d contains additional configuration items as follows:

         • 01-system-paths.conf contains all the paths that were once part of  Options->Paths  in
           the Web UI. You should not edit this file as it may be overwritten on an upgrade

         • 02-multiserver.conf  file consists of custom variables if you are deploying ZoneMinder
           in a multi-server configuration (see /installationguide/multiserver)

         • 03-custom.conf is an  custom config file that I created to override specific variables
           in the path files. This is the recommended way to customize entries. Anything that you
           want to change should be in a new file inside conf.d. Note that ZoneMinder  will  sort
           all  the files alphabetically and run their contents in ascending order. So it doesn’t
           really matter what you name them, as long as  you  make  sure  your  changes  are  not
           overwritten  by another file in the sorting sequence. It is therefore good practice to
           prefix your file names by  nn-  where  nn  is  a  monotonically  increasing  numerical
           sequence 01- 02- 03- and so forth, so you know the order they will be processed.

   Timezone Configuration
       Earlier  versions of ZoneMinder relied on php.ini to set Date/Time Zone. This is no longer
       the case. You can (and must) set the Timezone via the Web UI, starting ZoneMinder  version
       1.34. See here.

   Database Specific Configuration
   Todo
       do we really need to have this section? Not sure if its generic and not specific to ZM

       While  the  ZoneMinder  specific  database  config  entries  reside in /etc/zm/zm.conf and
       related customizations discussed  above,  general  database  configuration  items  can  be
       tweaked in /etc/mysql (or whichever path your DB server is installed)

API

       This document will provide an overview of ZoneMinder’s API.

   Overview
       In  an  effort  to further ‘open up’ ZoneMinder, an API was needed.  This will allow quick
       integration with and development of ZoneMinder.

       The API is built in CakePHP and lives under the /api directory.   It  provides  a  RESTful
       service  and  supports  CRUD  (create,  retrieve,  update, delete) functions for Monitors,
       Events, Frames, Zones and Config.

   API Wrappers
       • pyzm is a python wrapper for the ZoneMinder APIs. It supports both the  legacy  and  new
         token  based  API, as well as ZM logs/ZM shared memory support. See its project site for
         more details. Documentation is here.

   API evolution
       The ZoneMinder API has evolved over time. Broadly speaking the iterations were as follows:

       • Prior to version 1.29, there really was no API layer. Users had to  use  the  same  URLs
         that the web console used to ‘mimic’ operations, or use an XML skin

       • Starting  version  1.29, a v1.0 CakePHP based API was released which continues to evolve
         over time. From a security perspective, it still tied into ZM auth and  required  client
         cookies for many operations. Primarily, two authentication modes were offered:

         • You use cookies to maintain session state (ZM_SESS_ID)

         • You  use an authentication hash to validate yourself, which included encoding personal
           information and time stamps which at times caused timing validation issues, especially
           for mobile consumers

       • Starting  version  1.34,  ZoneMinder  has introduced a new “token” based system which is
         based JWT. We have given it a ‘2.0’ version ID. These tokens don’t encode  any  personal
         data  and  can  be  statelessly  passed  around per request. It introduces concepts like
         access tokens, refresh tokens and per user  level  API  revocation  to  manage  security
         better. The internal components of ZoneMinder all support this new scheme now and if you
         are using the APIs we strongly recommend you migrate to 1.34  and  use  this  new  token
         system  (as  a  side  note, 1.34 also moves from MYSQL PASSWORD to Bcrypt for passwords,
         which is also a good reason why you should migate).

       • Note that as of 1.34, both versions of API access will work (tokens and the  older  auth
         hash  mechanism),  however we no longer use sessions by default.  You will have to add a
         stateful=1 query parameter during login to tell  ZM  to  set  a  COOKIE  and  store  the
         required  info  in the session. This option is only available if OPT_USE_LEGACY_API_AUTH
         is set to ON.

       NOTE:
          For the rest of the document, we will specifically highlight v2.0 only features. If you
          don’t see a special mention, assume it applies for both API versions.

   Enabling API
       ZoneMinder  comes  with APIs enabled. To check if APIs are enabled, visit Options->System.
       If OPT_USE_API is enabled, your APIs are active.  For v2.0 APIs, you  have  an  additional
       option right below it:

          • OPT_USE_LEGACY_API_AUTH which is enabled by default. When enabled, the login.json API
            (discussed later) will return both the old  style  (auth=)  and  new  style  (token=)
            credentials.  The reason this is enabled by default is because any existing apps that
            use the API would break if they were not updated to  use  v2.0.  (Note  that  zmNinja
            1.3.057 and beyond will support tokens)

   Enabling secret key
       • It  is important that you create a “Secret Key”. This needs to be a set of hard to guess
         characters, that only you know. ZoneMinder does not create a key for  you.  It  is  your
         responsibility  to  create it. If you haven’t created one already, please do so by going
         to Options->Systems and populating AUTH_HASH_SECRET. Don’t forget to save.

       • If you plan on using V2.0 token based security, it is mandatory to populate this  secret
         key, as it is used to sign the token. If you don’t, token authentication will fail. V1.0
         did not mandate this requirement.

   Getting an API key
       To get an API key:

          curl -XPOST -d "user=yourusername&pass=yourpassword" https://yourserver/zm/api/host/login.json

       If you want to use a stateful connection, so you don’t have to pass auth credentials  with
       each query, you can use the following:

          curl -XPOST -c cookies.txt -d "user=yourusername&pass=yourpassword&stateful=1" https://yourserver/zm/api/host/login.json

       This returns a payload like this for API v1.0:

          {
              "credentials": "auth=05f3a50e8f7<deleted>063",
              "append_password": 0,
              "version": "1.33.9",
              "apiversion": "1.0"
          }

       Or for API 2.0:

          {
              "access_token": "eyJ0eXAiOiJK<deleted>HE",
              "access_token_expires": 3600,
              "refresh_token": "eyJ0eXAiOi<deleted>mPs",
              "refresh_token_expires": 86400,
              "credentials": "auth=05f3a50e8f7<deleted>063",  # only if OPT_USE_LEGACY_API_AUTH is enabled
              "append_password": 0, # only if OPT_USE_LEGACY_API_AUTH is enabled
              "version": "1.33.9",
              "apiversion": "2.0"
          }

   Using these keys with subsequent requests
       Once  you  have  the  keys (a.k.a credentials (v1.0, v2.0) or token (v2.0)) you should now
       supply that key to subsequent API calls like this:

          # v1.0 or 2.0 based API access (will only work if AUTH_HASH_LOGINS is enabled

          # RECOMMENDED: v2.0 token based
            curl -XGET  https://yourserver/zm/api/monitors.json?token=<access_token>

          # or, for legacy mode:

          curl -XGET  https://yourserver/zm/api/monitors.json?auth=<hex digits from 'credentials'>

          # or, if you specified -c cookies.txt in the original login request

          curl -b cookies.txt -XGET   https://yourserver/zm/api/monitors.json

       NOTE:
          If you are using an HTTP GET request, the token/auth needs to  be  passed  as  a  query
          parameter  in  the  URL.  If  you  are using an HTTP POST (like when you use the API to
          modify a monitor, for example), you can choose to pass the  token  as  a  data  payload
          instead.  The API layer discards data payloads for HTTP GET. Finally, If you don’t pass
          keys, you could also use cookies (not recommended as a general approach).

   Key lifetime (v1.0)
       If you are using the old credentials mechanism present in v1.0, then the credentials  will
       time  out  based  on  PHP  session  timeout  (if  you  are using cookies), or the value of
       AUTH_HASH_TTL (if you are using auth= and have enabled AUTH_HASH_LOGINS) which defaults to
       2  hours.   Note  that  there  is no way to look at the hash and decipher how much time is
       remaining. So it is your responsibility to record the time you got the hash and assume  it
       was generated at the time you got it and re-login before that time expires.

   Key lifetime (v2.0)
       In  version 2.0, it is easy to know when a key will expire before you use it. You can find
       that out from the access_token_expires and refresh_token_expires values (in seconds) after
       you  decode  the JWT key (there are JWT decode libraries for every language you want). You
       should refresh the keys before the timeout occurs, or you will not  be  able  to  use  the
       APIs.

   Understanding access/refresh tokens (v2.0)
       If you are using V2.0, then you need to know how to use these tokens effectively:

       • Access  tokens  are  short  lived.  ZoneMinder  issues  access tokens that live for 3600
         seconds (1 hour).

       • Access tokens should be used for all subsequent API accesses.

       • Refresh tokens should ONLY be used to generate new access tokens.  For  example,  if  an
         access  token  lives  for  1  hour, before the hour completes, invoke the login.json API
         above with the refresh token to get a new access token. ZoneMinder issues refresh tokens
         that live for 24 hours.

       • To  generate a new refresh token before 24 hours are up, you will need to pass your user
         login and password to login.json

       To Summarize:

       • Pass your username and password to login.json only once in 24 hours to renew your tokens

       • Pass your “refresh token” to login.json once in two hours (or whatever you have set  the
         value of AUTH_HASH_TTL to) to renew your access token

       • Use your access token for all API invocations.

       In  fact,  V2.0  will  reject your request (if it is not to login.json) if it comes with a
       refresh token instead of an access token to discourage usage of this token when it  should
       not be used.

       This  minimizes  the  amount of sensitive data that is sent over the wire and the lifetime
       durations are made so that if they get compromised, you can regenerate or invalidate  them
       (more on this later)

   Understanding key security
       • Version 1.0 uses an MD5 hash to generate the credentials. The hash is computed over your
         secret key (if available), username, password  and  some  time  parameters  (along  with
         remote  IP if enabled). This is not a secure/recommended hashing mechanism. If your auth
         hash is compromised, an attacker will be able to use your hash till it expires. To avoid
         this,  you  could  disable  the  user  in  ZoneMinder.  Furthermore,  enabling remote IP
         (AUTH_HASH_REMOTE_IP) requires that you issue future requests  from  the  same  IP  that
         generated  the  tokens.  While  this may be considered an additional layer for security,
         this can cause issues with mobile devices.

       • Version 2.0 uses a different approach. The hash is  a  simple  base64  encoded  form  of
         “claims”,  but  signed  with your secret key. Consider for example, the following access
         key:

          eyJ0eXAiOiJKV1QiLCJhbGciOiJIUzI1NiJ9.eyJpc3MiOiJab25lTWluZGVyIiwiaWF0IjoxNTU3OTQwNzUyLCJleHAiOjE1NTc5NDQzNTIsInVzZXIiOiJhZG1pbiIsInR5cGUiOiJhY2Nlc3MifQ.-5VOcpw3cFHiSTN5zfGDSrrPyVya1M8_2Anh5u6eNlI

       If you were to use any JWT token verifier it can easily decode that token and will show:

          {
          "iss": "ZoneMinder",
          "iat": 1557940752,
          "exp": 1557944352,
          "user": "admin",
          "type": "access"
          }
          Invalid Signature

       Don’t be surprised. JWT tokens, by default, are not meant to be encrypted. It is  just  an
       assertion  of  a  claim.  It  states  that the issuer of this token was ZoneMinder, It was
       issued at (iat) Wednesday, 2019-05-15 17:19:12 UTC and will  expire  on  (exp)  Wednesday,
       2019-05-15 18:19:12 UTC. This token claims to be owned by an admin and is an access token.
       If your token were to be stolen, this information is available to the person who stole it.
       Note that there are no sensitive details like passwords in this claim.

       However,  that  person  will not have your secret key as part of this token and therefore,
       will NOT be able to create a new JWT token  to  get,  say,  a  refresh  token.  They  will
       however,  be  able  to  use  your access token to access resources just like the auth hash
       above, till the access token expires (2 hrs). To revoke this  token,  you  don’t  need  to
       disable  the  user.  Go  to  Options->API and tap on “Revoke All Access Tokens”. This will
       invalidate the token immediately (this option will invalidate all tokens  for  all  users,
       and new ones will need to be generated).

       Over time, we will provide you with more fine grained access to these options.

       Summarizing good practices:

       • Use HTTPS, not HTTP

       • If  possible,  use  free  services  like LetsEncrypt instead of self-signed certificates
         (sometimes this is not possible)

       • Keep your tokens as private as possible, and use them as recommended above

       • If you believe your tokens are compromised, revoke them, but also check if your attacker
         has  compromised more than you think (example, they may also have your username/password
         or access to your system via other exploits, in which case they can regenerate  as  many
         tokens/credentials as they want).

       NOTE:
          Subsequent  sections  don’t explicitly callout the key addition to APIs. We assume that
          you will append the correct keys as per our explanation above.

   Examples
       (In all examples, replace ‘server’ with IP or hostname & port where ZoneMinder is running)

   API Version
       To retrieve the API version:

          curl http://server/zm/api/host/getVersion.json

   Return a list of all monitors
          curl http://server/zm/api/monitors.json

       It is worthwhile to note that starting ZM 1.32.3 and  beyond,  this  API  also  returns  a
       Monitor_Status object per monitor. It looks like this:

          "Monitor_Status": {
                  "MonitorId": "2",
                  "Status": "Connected",
                  "CaptureFPS": "1.67",
                  "AnalysisFPS": "1.67",
                  "CaptureBandwidth": "52095"
              }

       If  you don’t see this in your API, you are running an older version of ZM. This gives you
       a very convenient way  to  check  monitor  status  without  calling  the  daemonCheck  API
       described later.

   Retrieve monitor 1
          curl http://server/zm/api/monitors/1.json

   Change State of Monitor 1
       This API changes monitor 1 to Modect and Enabled

          curl -XPOST http://server/zm/api/monitors/1.json -d "Monitor[Function]=Modect&Monitor[Enabled]=1"

   Get Daemon Status of Monitor 1
          curl http://server/zm/api/monitors/daemonStatus/id:1/daemon:zmc.json

   Add a monitor
       This command will add a new http monitor.

          curl -XPOST http://server/zm/api/monitors.json -d "Monitor[Name]=Cliff-Burton\
          &Monitor[Function]=Modect\
          &Monitor[Protocol]=http\
          &Monitor[Method]=simple\
          &Monitor[Host]=usr:pass@192.168.11.20\
          &Monitor[Port]=80\
          &Monitor[Path]=/mjpg/video.mjpg\
          &Monitor[Width]=704\
          &Monitor[Height]=480\
          &Monitor[Colours]=4"

   Edit monitor 1
       This command will change the ‘Name’ field of Monitor 1 to ‘test1’

          curl -XPUT http://server/zm/api/monitors/1.json -d "Monitor[Name]=test1"

   Delete monitor 1
       This command will delete Monitor 1, but will _not_ delete any Events which depend on it.

          curl -XDELETE http://server/zm/api/monitors/1.json

   Arm/Disarm monitors
       This command will force an alarm on Monitor 1:

          curl http://server/zm/api/monitors/alarm/id:1/command:on.json

       This command will disable the  alarm on Monitor 1:

          curl http://server/zm/api/monitors/alarm/id:1/command:off.json

       This command will report the status of the alarm  Monitor 1:

          curl http://server/zm/api/monitors/alarm/id:1/command:status.json

   Return a list of all events
          http://server/zm/api/events.json

       Note  that events list can be quite large and this API (as with all other APIs in ZM) uses
       pagination. Each page returns a specific set of entries. By default this is  25  and  ties
       into WEB_EVENTS_PER_PAGE in the ZM options menu.

       So  the  logic  to  iterate through all events should be something like this (pseudocode):
       (unfortunately there is no way to get pageCount without getting the first page)

          data = http://server/zm/api/events.json?page=1 # this returns the first page
          # The json object returned now has a property called data.pagination.pageCount
          count = data.pagination.pageCount;
          for (i=1, i<count, i++)
          {
            data = http://server/zm/api/events.json?page=i;
             doStuff(data);
          }

   Retrieve event Id 1000
          curl -XGET http://server/zm/api/events/1000.json

   Edit event 1
       This command will change the ‘Name’ field of Event 1 to ‘Seek and Destroy’

          curl -XPUT http://server/zm/api/events/1.json -d "Event[Name]=Seek and Destroy"

   Delete event 1
       This command will delete Event 1, and any Frames which depend on it.

          curl -XDELETE http://server/zm/api/events/1.json

   Return a list of events for a specific monitor Id =5
          curl -XGET http://server/zm/api/events/index/MonitorId:5.json

       Note that the same pagination logic applies if the list is too long

   Return a list of events for a specific monitor within a specific date/time range
          http://server/zm/api/events/index/MonitorId:5/StartTime >=:2015-05-15 18:43:56/EndTime <=:2015-05-16 18:43:56.json

       To try this in CuRL, you need to URL escape the spaces like so:

          curl -XGET  "http://server/zm/api/events/index/MonitorId:5/StartTime%20>=:2015-05-15%2018:43:56/EndTime%20<=:2015-05-16%2018:43:56.json"

   Return a list of events for all monitors within a specified date/time range
          curl -XGET "http://server/zm/api/events/index/StartTime%20>=:2015-05-15%2018:43:56/EndTime%20<=:208:43:56.json"

   Return event count based on times and conditions
       The API also supports a handy mechanism to return a count of events for a period of time.

       This returns number of events per monitor that were recorded in the last one hour

          curl "http://server/zm/api/events/consoleEvents/1%20hour.json"

       This returns number of events per monitor that were recorded in the last day  where  there
       were atleast 10 frames that were alarms”

          curl "http://server/zm/api/events/consoleEvents/1%20day.json/AlarmFrames >=: 10.json"

   Return sorted events
       This returns a list of events within a time range and also sorts it by descending order

          curl -XGET "http://server/zm/api/events/index/StartTime%20>=:2015-05-15%2018:43:56/EndTime%20<=:208:43:56.json?sort=StartTime&direction=desc"

   Configuration Apis
       The APIs allow you to access all the configuration parameters of ZM that you typically set
       inside the web console.  This returns the full list of configuration parameters:

          curl -XGET http://server/zm/api/configs.json

       Each configuration parameter has an Id, Name, Value and other fields. Chances are you  are
       likely only going to focus on these 3.

       The edit function of the Configs API is a little quirky at the moment. Its format deviates
       from the usual edit flow of other APIs. This will be fixed, eventually. For now, to change
       the “Value” of ZM_X10_HOUSE_CODE from A to B:

          curl -XPUT http://server/zm/api/configs/edit/ZM_X10_HOUSE_CODE.json  -d "Config[Value]=B"

       To validate changes have been made:

          curl -XGET http://server/zm/api/configs/view/ZM_X10_HOUSE_CODE.json

   Run State Apis
       ZM API can be used to start/stop/restart/list states of  ZM as well Examples:

          curl -XGET  http://server/zm/api/states.json # returns list of run states
          curl -XPOST  http://server/zm/api/states/change/restart.json #restarts ZM
          curl -XPOST  http://server/zm/api/states/change/stop.json #Stops ZM
          curl -XPOST  http://server/zm/api/states/change/start.json #Starts ZM

   Create a Zone
          curl -XPOST http://server/zm/api/zones.json -d "Zone[Name]=Jason-Newsted\
          &Zone[MonitorId]=3\
          &Zone[Type]=Active\
          &Zone[Units]=Percent\
          &Zone[NumCoords]=4\
          &Zone[Coords]=0,0 639,0 639,479 0,479\
          &Zone[Area]=307200\
          &Zone[AlarmRGB]=16711680\
          &Zone[CheckMethod]=Blobs\
          &Zone[MinPixelThreshold]=25\
          &Zone[MaxPixelThreshold]=\
          &Zone[MinAlarmPixels]=9216\
          &Zone[MaxAlarmPixels]=\
          &Zone[FilterX]=3\
          &Zone[FilterY]=3\
          &Zone[MinFilterPixels]=9216\
          &Zone[MaxFilterPixels]=230400\
          &Zone[MinBlobPixels]=6144\
          &Zone[MaxBlobPixels]=\
          &Zone[MinBlobs]=1\
          &Zone[MaxBlobs]=\
          &Zone[OverloadFrames]=0"

   PTZ Control Meta-Data APIs
       PTZ  controls  associated  with  a  monitor  are  stored in the Controls table and not the
       Monitors table inside ZM. What that means is when you get the details of  a  Monitor,  you
       will only know if it is controllable (isControllable:true) and the control ID.  To be able
       to retrieve PTZ information related to that Control ID, you need to use the controls API

       Note that these APIs only retrieve control data related to PTZ. They don’t  actually  move
       the camera. See the “PTZ on live streams” section to move the camera.

       This returns all the control definitions:

          curl http://server/zm/api/controls.json

       This returns control definitions for a specific control ID=5

          curl http://server/zm/api/controls/5.json

   Host APIs
       ZM  APIs  have various APIs that help you in determining host (aka ZM) daemon status, load
       etc. Some examples:

          curl -XGET  http://server/zm/api/host/getLoad.json # returns current load of ZM

          # Note that ZM 1.32.3 onwards has the same information in Monitors.json which is more reliable and works for multi-server too.
          curl -XGET  http://server/zm/api/host/daemonCheck.json # 1 = ZM running 0=not running

          # The API below uses "du" to calculate disk space. We no longer recommend you use it if you have many events. Use the Storage APIs instead, described later
          curl -XGET  http://server/zm/api/host/getDiskPercent.json # returns in GB (not percentage), disk usage per monitor (that is,space taken to store various event related information,images etc. per monitor)

   Storage and Server APIs
       ZoneMinder   introduced   many   new   options   that    allowed    you    to    configure
       multiserver/multistorage  configurations.  While  a part of this was available in previous
       versions, a lot of rework was done as part of ZM 1.31 and 1.32. As part of  that  work,  a
       lot  of  new and useful APIs were added. Some of these are part of ZM 1.32 and others will
       be part of ZM 1.32.3 (of course, if you build from master, you can access them right away,
       or wait till a stable release is out.

       This  returns  storage  data for my single server install. If you are using multi-storage,
       you’ll see many such “Storage” entries, one for each storage defined:

          curl http://server/zm/api/storage.json

       Returns:

          {
              "storage": [
                  {
                      "Storage": {
                          "Id": "0",
                          "Path": "\/var\/cache\/zoneminder\/events",
                          "Name": "Default",
                          "Type": "local",
                          "Url": null,
                          "DiskSpace": "364705447651",
                          "Scheme": "Medium",
                          "ServerId": null,
                          "DoDelete": true
                      }
                   }
                 ]
          }

       “DiskSpace” is the disk used in bytes. While this doesn’t return disk space data  as  rich
       as  /host/getDiskPercent, it is much more efficient.

       Similarly,

          curl http://server/zm/api/servers.json

       Returns:

          {
                "servers": [
                    {
                        "Server": {
                            "Id": "1",
                            "Name": "server1",
                            "Hostname": "server1.mydomain.com",
                            "State_Id": null,
                            "Status": "Running",
                            "CpuLoad": "0.9",
                            "TotalMem": "6186237952",
                            "FreeMem": "156102656",
                            "TotalSwap": "536866816",
                            "FreeSwap": "525697024",
                            "zmstats": false,
                            "zmaudit": false,
                            "zmtrigger": false
                        }
                    }
                ]
            }

       This  only  works if you have a multiserver setup in place. If you don’t it will return an
       empty array.

   Other APIs
       This is not a complete list. ZM supports more parameters/APIs. A good way to dive in is to
       look at the API code directly.

   Streaming Interface
       Developers  working  on  their  application often ask if there is an “API” to receive live
       streams, or recorded event streams.  It is possible  to  stream  both  live  and  recorded
       streams.  This isn’t strictly an “API” per-se (that is, it is not integrated into the Cake
       PHP based API layer discussed here) and also why we’ve used the term  “Interface”  instead
       of an “API”.

   Live Streams
       What  you need to know is that if you want to display “live streams”, ZoneMinder sends you
       streaming JPEG images (MJPEG) which can easily be rendered in a browser using an  img  src
       tag.

       For example:

          <img src="https://yourserver/zm/cgi-bin/nph-zms?scale=50&width=640p&height=480px&mode=jpeg&maxfps=5&buffer=1000&&monitor=1&token=eW<deleted>03&connkey=36139" />

          # or

          <img src="https://yourserver/zm/cgi-bin/nph-zms?scale=50&width=640p&height=480px&mode=jpeg&maxfps=5&buffer=1000&&monitor=1&auth=b5<deleted>03&connkey=36139" />

       will  display  a live feed from monitor id 1, scaled down by 50% in quality and resized to
       640x480px.

       • This assumes /zm/cgi-bin is your CGI_BIN path. Change it to  what  is  correct  in  your
         system

       • The  “auth”  token  you  see  above is required if you use ZoneMinder authentication. To
         understand how to get the auth token, please read the “Login,  Logout  &  API  security”
         section below.

       • The  “connkey”  parameter  is  essentially  a  random number which uniquely identifies a
         stream. If you don’t specify a connkey, ZM will generate its own. It is  recommended  to
         generate  a  connkey  because  you can then use it to “control” the stream (pause/resume
         etc.)

       • Instead of dealing with the “auth” token, you can also use  &user=username&pass=password
         where  “username” and “password” are your ZoneMinder username and password respectively.
         Note that this is not recommended because you are transmitting them in a URL and even if
         you use HTTPS, they may show up in web server logs.

   PTZ on live streams
       PTZ  commands  are  pretty  cryptic  in  ZoneMinder. This is not meant to be an exhaustive
       guide, but just something to whet your appetite:

       Lets assume you have a monitor, with ID=6. Let’s further assume you want to pan it left.

       You’d need to send a: POST command to https://yourserver/zm/index.php with  the  following
       data payload in the command (NOT in the URL)

       view=request&request=control&id=6&control=moveConLeft&xge=30&yge=30

       Obviously, if you are using authentication, you need to be logged in for this to work.

       Like  I said, at this stage, this is only meant to get you started. Explore the ZoneMinder
       code and use “Inspect source” as you use PTZ  commands  in  the  ZoneMinder  source  code.
       control_functions.php is a great place to start.

   Pre-recorded (past event) streams
       Similar to live playback, if you have chosen to store events in JPEG mode, you can play it
       back using:

          <img src="https://yourserver/zm/cgi-bin/nph-zms?mode=jpeg&frame=1&replay=none&source=event&event=293820&connkey=77493&token=ew<deleted>" />

          # or

          <img src="https://yourserver/zm/cgi-bin/nph-zms?mode=jpeg&frame=1&replay=none&source=event&event=293820&connkey=77493&auth=b5<deleted>" />

       • This assumes /zm/cgi-bin is your CGI_BIN path. Change it to  what  is  correct  in  your
         system

       • This will playback event 293820, starting from frame 1 as an MJPEG stream

       • Like before, you can add more parameters like scale etc.

       • auth  and  connkey  have  the  same  meaning as before, and yes, you can replace auth by
         &user=usename&pass=password as before and the same security concerns cited above apply.

       If instead, you have chosen to use the MP4  (Video)  storage  mode  for  events,  you  can
       directly play back the saved video file:

          <video src="https://yourserver/zm/index.php?view=view_video&eid=294690&token=eW<deleted>" type="video/mp4"></video>

          # or

          <video src="https://yourserver/zm/index.php?view=view_video&eid=294690&auth=33<deleted>" type="video/mp4"></video>

       This above will play back the video recording for event 294690

   What other parameters are supported?
       The  best  way to answer this question is to play with ZoneMinder console. Open a browser,
       play back live or recorded feed, and do an “Inspect Source” to  see  what  parameters  are
       generated. Change and observe.

   Further Reading
       As  described  earlier, treat this document as an “introduction” to the important parts of
       the API and streaming interfaces.   There  are  several  details  that  haven’t  yet  been
       documented. Till they are, here are some resources:

       • zmNinja, the open source mobile app for ZoneMinder is 100% based on ZM APIs. Explore its
         source code to see how things work.

       • Launch up ZM console in a browser, and do an “Inspect source”. See how images are  being
         rendered.  Go  to  the  networks  tab  of the inspect source console and look at network
         requests that are made when you pause/play/forward streams.

       • If you still can’t find an answer, post your question in  the  forums  (not  the  github
         repo).

FAQ

TODO

       needs  to  be  reviewed  -  some entries may be old/invalid. I’ve done one round, but icOn
       needs to review.

       This is the FAQ page. Feel free to contribute any FAQs that you think are missing.

       NOTE:
          It is always a good idea to refer to the ZoneMinder forums for tips and  tricks.  While
          we  try  and  make  sure  this  FAQ  is pruned/adjusted to align with the latest stable
          release, some of the entries may  no  longer  be  accurate  (or  there  may  be  better
          suggestions in the forums).

   How can I stop ZoneMinder filling up my disk?
       Recent  versions  of  ZoneMinder  come  with a filter you can use for this purpose already
       included.  The filter is called PurgeWhenFull and to find it, click on the word Filters in
       the  header.   Note that this filter is automatically enabled if you do a fresh install of
       ZoneMinder including creating a new database. If you already have an existing database and
       are  upgrading  ZoneMinder,  it  will  retain the settings of the filter (which in earlier
       releases was disabled by default). So you may want to check if  PurgeWhenFull  is  enabled
       and if not, enable it.

       To enable it, go to Web Console, click on the word Filters in the UI header.

       In  the  filter window there is a drop down select box labeled ‘Use Filter’, that lets you
       select a saved filter. Select ‘PurgeWhenFull’ and it will load that filter.

       Make any modifications you might want, such as the percentage full you want it to kick in,
       or  how many events to delete at a time (it will repeat the filter as many times as needed
       to clear the space, but will only delete this many events each time to get there).

       Ensure that the Run filter in background checkbox is checked.  Ensure that the Delete  all
       matches checkbox is checked.

       Then  click  on  ‘Save’.  The filter will immediately begin executing in the background to
       keep your disk within those limits.

       Please note that that this filter will only affect the default storage location.   If  you
       have  added  other storage areas, you must create a PurgeWhenFull filter for each one, and
       specify the Storage Area as one of the parameters in the filter.  You  can  duplicate  the
       existing PurgeWhenFull filter by using Save As instead of Save.

       Check  the  zmfilter.log file to make sure it is running as sometimes missing perl modules
       mean that it never runs but people don’t always realize.

       Purge By Age To delete events that are older than 7 days, create a new  filter  with  “End
       Date”  set  to  “less  than”  and a value of “-7 days”, sort by “date/time” in “asc”ending
       order, then enable the checkbox “delete all matches”. You can also use a value of week  or
       week and days: “-2 week”  or “-2 week 4 day”

       Save  with ‘Run Filter In Background’ enabled to have it run automatically.  Optional skip
       archived events:  click on the plus sign next to -7 days to add another condition.   “and”
       “archive status” equal to “unarchived only”.

       Optional  slow delete:  limit the number of results to a number, say 10 in the filter.  If
       you have a large backlog of events that would be deleted, this  can  hard  spike  the  CPU
       usage  for  a long time.  Limiting the number of results to only the first three each time
       the filter is run spreads out the delete processes over time, dramatically  lessening  the
       CPU load.

       WARNING:
          We  no longer recommend use enable OPT_FAST_DELETE or RUN_AUDIT anymore, unless you are
          using an old or low powered system to run Zoneminder.  Please  consider  the  remaining
          tips in this answer to be ‘generally deprecated, use only if you must’.

       There  are  two  methods for ZM to remove files when they are deleted that can be found in
       Options under the System tab ZM_OPT_FAST_DELETE and ZM_RUN_AUDIT.

       ZM_OPT_FAST_DELETE:

       Normally an event created as the result of an alarm consists of entries  in  one  or  more
       database  tables  plus  the  various files associated with it. When deleting events in the
       browser it can take a long time to remove all of this if you are trying to  do  a  lot  of
       events  at  once.  If you are running on an older or under-powered system, you may want to
       set this option which means that the browser client only deletes the key  entries  in  the
       events  table, which means the events will no longer appear in the listing, and leaves the
       zmaudit daemon to clear up the rest later. If you do so, disk  space  will  not  be  freed
       immediately  so  you  will  need  to  run  zmaudit more frequently.  On modern systems, we
       recommend that you leave this off.

       ZM_RUN_AUDIT:

       The zmaudit daemon exists to check that the saved information in the database and  on  the
       file  system  match  and  are consistent with each other. If an error occurs or if you are
       using ‘fast deletes’ it may be that database records are deleted but files remain. In this
       case,  and  similar, zmaudit will remove redundant information to synchronize the two data
       stores. This option controls whether zmaudit is run in the background and  performs  these
       checks  and fixes continuously. This is not recommended for most systems, as zmaudit.pl is
       very resource intensive.

       ZM_AUDIT_CHECK_INTERVAL:

       The zmaudit daemon exists to check that the saved information in the database and  on  the
       files  system  match  and are consistent with each other. If an error occurs or if you are
       using ‘fast deletes’ it may be that database records are deleted but files remain. In this
       case,  and  similar, zmaudit will remove redundant information to synchronize the two data
       stores. The default check interval of 900 seconds (15 minutes) is fine  for  most  systems
       however if you have a very large number of events the process of scanning the database and
       file system may take a long time and impact performance. In this case you  may  prefer  to
       make this interval much larger to reduce the impact on your system. This option determines
       how often these checks are performed.

   Math for Memory: Making sure you have enough memory to handle your cameras
       One of the most common issues for erratic ZoneMinder behavior is  you  don’t  have  enough
       memory  to handle all your cameras. Many users often configure multiple HD cameras at full
       resolution and 15FPS or more and then face various issues about processes  failing,  blank
       screens  and  other  completely  erratic  behavior. The core reason for all of this is you
       either don’t have enough memory or horsepower to handle all  your  cameras.  The  solution
       often is to reduce FPS, reduce cameras or bump up your server capabilities.

       Here are some guidelines with examples on how you can figure out how much memory you need.
       With respect to CPU, you should benchmark your server using standard unix tools like  top,
       iotop  and  others to make sure your CPU load is manageable. ZoneMinder also shows average
       load on the top right corner of the Web Console for easy access.

       In general a good estimate of memory required would be:

          Min Bits of Memory = 20% overhead * (image-width*image-height*image buffer size*target color space*number of cameras)

       Where:

       • image-width and image-height are the width and height of  images  that  your  camera  is
         configured for (in my case, 1280x960). This value is in the Source tab for each monitor

       • image  buffer size is the # of images ZM will keep in memory (this is used by ZM to make
         sure it has pre and post images before detecting an alarm - very useful because  by  the
         time an alarm is detected, the reason for the alarm may move out of view and a buffer is
         really useful for this, including for analyzing stats/scores).  This  value  is  in  the
         buffers tab for each monitor

       • target  color  space is the color depth - 8bit, 24bit or 32bit. It’s again in the source
         tab of each monitor

       The 20% overhead on top of the calculation to account for image/stream overheads (this  is
       an estimate)

       The  math  breakdown  for  4  cameras running at 1280x960 capture, 50 frame buffer, 24 bit
       color space:

          1280*960 = 1,228,800 (bytes)
          1,228,800 * (3 bytes for 24 bit) = 3,686,400 (bytes)
          3,686,400 * 50 = 184,320,000 (bytes)
          184,320,000 * 4 = 737,280,000 (bytes)
          737,280,000 / 1024 = 720,000 (Kilobytes)
          720,000 / 1024 = 703.125 (Megabytes)
          703.125 / 1024 = 0.686 (Gigabytes)

       Around 700MB of memory.

       So if you have 2GB of memory, you should be all set. Right? Not, really:

          • This is just the base memory required to capture the streams. Remember ZM  is  always
            capturing streams irrespective of whether you are actually recording or not - to make
            sure its image ring buffer is there with pre images when an alarm kicks in.

          • You also need to account for other processes not related to ZM running in your box

          • You also need to account for other ZM processes - for example, I  noticed  the  audit
            daemon takes up a good amount of memory when it runs, DB updates also take up memory

          • If you are using H264 encoding, that buffers a lot of frames in memory as well.

       So a good rule of thumb is to make sure you have twice the memory as the calculation above
       (and if you are using the ZM server for other purposes,  please  factor  in  those  memory
       requirements as well)

       Also remember by default ZM only uses 50% of your available memory unless you change it

       As it turns out, ZM uses mapped memory and by default, 50% of your physical memory is what
       this will grow to. When you reach that limit , ZM breaks down with various errors.

       A good way to know how much memory is allocated to ZM for its operation is to do a df -h

       A sample output on Ubuntu:

          pp@camerapc:~$ df -h|grep "Filesystem\|shm"
          Filesystem                 Size  Used Avail Use% Mounted on
          tmpfs                      2.6G  923M  1.7G  36% /run/shm

       The key item here is tmpfs –> the example above shows we have  allocated  1.7G  of  mapped
       memory  space of which 36% is used which is a healthy number. If you are seeing Use% going
       beyond 70% you should probaby increase the mapped memory.

       For example, if you want to increase this limit to 70% of your memory, add  the  following
       to /etc/fstab tmpfs SHMPATH tmpfs defaults,noexec,nosuid,size=70% 0 0 where SHMPATH is the
       Mounted on path.  Here, that would be /run/shm.  Other systems may be /dev/shm.

   I have enabled motion detection but it is not always being triggered when things happen in the
       camera view
       ZoneMinder  uses zones to examine images for motion detection. When you create the initial
       zones you can choose from a number of preset values for sensitivity etc. Whilst these  are
       usually a good starting point they are not always suitable for all situations and you will
       probably need to tweak the values for your specific circumstances.  The  meanings  of  the
       various  settings  are  described  in  the  documentation (here). Another user contributed
       illustrated Zone definition guide can be found here: An illustrated guide to Zones

       However if you believe you have sensible settings configured  then  there  are  diagnostic
       approaches you can use.

   Event Statistics
       The  first  technique  is  to  use  event  statistics.  Firstly you should ensure they are
       switched on in Options->Logging->RECORD_EVENT_STATS. This will then cause the  raw  motion
       detection  statistics for any subsequently generated events to be written to the DB. These
       can then be accessed by first clicking on the Frames or Alarm Frames values of  the  event
       from  any  event list view in the web gui. Then click on the score value to see the actual
       values that caused the event. Alternatively the stats can be accessed by clicking  on  the
       ‘Stats’ link when viewing any individual frame. The values displayed there correspond with
       the values that are used in the zone configuration and give you  an  idea  of  what  ‘real
       world’ values are being generated.

       Note that if you are investigating why events ‘do not’ happen then these will not be saved
       and so won’t be accessible. The best thing to do in that circumstance is to make your zone
       more sensitive so that it captures all events (perhap even ones you don’t want) so you can
       get an idea of what values are being generated and then  start  to  adjust  back  to  less
       sensitive  settings  if  necessary.  You  should  make sure you test your settings under a
       variety of lighting conditions (e.g. day and night, sunny or dull) to get  the  best  feel
       for that works and what doesn’t.

       Using  statistics will slow your system down to a small degree and use a little extra disk
       space in the DB so once you are happy you  can  switch  them  off  again.  However  it  is
       perfectly  feasible  to keep them permanently on if your system is able to cope which will
       allow you to review your setting periodically.

   Diagnostic Images along with FIFO
       The second approach is to use diagnostic images which are saved copies of the intermediate
       images that ZM uses when determining motion detection. These are switched on and off using
       Options->Logging->RECORD_DIAG_IMAGES.

       NOTE:
          In addition to the detailed explanation below, a recently added RECORD_DIAG_IMAGES_FIFO
          option,  also  available  in Options->Logging can be an invaluable tool to see how your
          current motion settings are affecting motion detection. The delta stream along with the
          raw (json output) stream can be invaluable to see the effect in real time. Please refer
          to the explanation of this feature in Options - Logging

       There are two kinds of diagnostic images which  are  and  are  written  (and  continuously
       overwritten)  to  the top level monitor event directory. If an event occurs then the files
       are additionally copied to the event directory and  renamed  with  the  appropriate  frame
       number as a prefix.

       The first set are produced by the monitor on the image as a whole. The diag-r.jpg image is
       the current reference image against which all  individual  frames  are  compared  and  the
       diag-d.jpg  image  is  the  delta  image highlighting the difference between the reference
       image and the last analysed image. In this images identical pixels will be black  and  the
       more  different  a  pixel is the whiter it will be. Viewing this image and determining the
       colour of the pixels is a good way of getting a feel for the pixel differences  you  might
       expect (often more than you think).

       The  second  set  of diag images are labelled as diag-<zoneid>-<stage>.jpg where zoneid is
       the id of the zone in question (Smile) and the stage is where in the alarm  check  process
       the  image  is generated from. So if you have several zones you can expect to see multiple
       files. Also these files are only interested in what is happening in their  zone  only  and
       will  ignore anything else outside of the zone. The stages that each number represents are
       as follows,

       • Alarmed Pixels - This image shows all pixels in the  zone  that  are  considered  to  be
         alarmed as white pixels and all other pixels as black.

       • Filtered Pixels - This is as stage one except that all pixels removed by the filters are
         now black. The white pixels represent the pixels that  are  candidates  to  generate  an
         event.

       • Raw  Blobs  -  This  image  contains all alarmed pixels from stage 2 but aggrageted into
         blobs. Each blob will have a different greyscale value (between 1 and 254) so  they  can
         be difficult to spot with the naked eye but using a colour picker or photoshop will make
         it easier to see what blob is what.

       • Filtered Blobs - This image is as stage 3 but under (or  over)  sized  blobs  have  been
         removed.  This is the final step before determining if an event has occurred, just prior
         to the number of blobs being counted. Thus this image forms the  basis  for  determining
         whether  an event is generated and outlining on alarmed images is done from the blobs in
         this image.

       Using the above images you should be able to tell at  all  stages  what  ZM  is  doing  to
       determine  if  an  event  should happen or not. They are useful diagnostic tools but as is
       mentioned elsewhere they will massively slow your system down and take  up  a  great  deal
       more  space.  You  should  never  leave  ZM running for any length of time with diagnostic
       images on.

   Why can’t ZoneMinder capture images (either at all or just particularly fast) when I  can  see
       my camera just fine in xawtv or similar?
       With  capture  cards ZoneMinder will pull images as fast as it possibly can unless limited
       by configuration.  ZoneMinder  (and  any  similar  application)  uses  the  frame  grabber
       interface to copy frames from video memory into user memory. This takes some time, plus if
       you have several inputs sharing one capture chip it has to switch between  inputs  between
       captures which further slows things down.

       On  average  a  card  that  can  capture at 25fps per chip PAL for one input will do maybe
       6-10fps for two, 1-4fps for three and 1-2 for four. For a 30fps NTSC chip the figures will
       be  correspondingly  higher.  However  sometimes it is necessary to slow down capture even
       further as after an input switch it may take a short while for the  new  image  to  settle
       before it can be captured without corruption.

       When using xawtv etc to view the stream you are not looking at an image captured using the
       frame grabber but the card’s video memory  mapped  onto  your  screen.  This  requires  no
       capture  or  processing  unless  you  do  an explicit capture via the J or ctrl-J keys for
       instance. Some cards or drivers do not support the frame grabber interface at all  so  may
       not  work  with ZoneMinder even though you can view the stream in xawtv. If you can grab a
       still using the grab functionality of xawtv then in  general  your  card  will  work  with
       ZoneMinder.

   Why can’t I see streamed images when I can see stills in the zone window etc?
       This issue is normally down to one of two causes

       1. You are using Internet Explorer and are trying to view multi-part jpeg streams. IE does
          not support these streams directly, unlike  most  other  browsers.  You  will  need  to
          install  Cambozola or another multi-part jpeg aware plugin to view them. To do this you
          will need to obtain the applet from the Downloads page and  install  the  cambozola.jar
          file  in  the  same  directory  as  the  ZoneMinder php files. Then find the ZoneMinder
          Options->Images page and enable OPT_CAMBOZOLA and enter the web path to the  .jar  file
          in  PATH_CAMBOZOLA. This will ordinarily just be cambozola.jar. Provided (Options / B/W
          tabs) WEB_H_CAN_STREAM is set to auto and  WEB_H_STREAM_METHOD  is  set  to  jpeg  then
          Cambozola should be loaded next time you try and view a stream.

       NOTE:  If  you find that the Cambozola applet loads in IE but the applet just displays the
       version  of Cambozola and the author’s name (as opposed to seeing the  streaming  images),
       you may need to chmod (-rwxrwxr-x) your (usr/share/zoneminder/) cambozola.jar:

          sudo chmod 775 cambozola.jar

       Once I did this, images started to stream for me.

       2. The  other common cause for being unable to view streams is that you have installed the
          ZoneMinder cgi binaries (zms and nph-zms) in a different directory than your web server
          is  expecting.  Make  sure  that  the  –with-cgidir  option  you  use to the ZoneMinder
          configure script is the same as the CGI directory configure for your web server. If you
          are  using  Apache,  which  is  the most common one, then in your httpd.conf file there
          should be  a  line  like  ScriptAlias  /cgi-bin/  "/var/www/cgi-bin/"  where  the  last
          directory  in  the  quotes is the one you have specified. If not then change one or the
          other to match. Be warned that configuring apache can be complex so  changing  the  one
          passed   to  the  ZoneMinder  configure  (and  then  rebuilding  and  reinstalling)  is
          recommended in the first instance. If you change the apache config  you  will  need  to
          restart  apache for the changes to take effect. If you still cannot see stream reliably
          then try changing ZM_PATH_ZMS in your /etc/zm/config  directory  to  just  use  zms  if
          nph-zms is specified, or vice versa. Also check in your apache error logs.

       Lastly,  please  look for errors created by the zmc processes.  If zmc isn’t running, then
       zms will not be able to get an image from it and will exit.

   I have several monitors configured but when I load the Montage view why can I  only  see  two?
       or, Why don’t all my cameras display when I use the Montage view?
       By  default  most  browsers only support a small number of simultaneous connections to any
       given server. Using the montage view usually requires one persistent connection  for  each
       camera plus intermittent connections for other information such as statuses.

       In  firefox  you  can  increase the limit, but other browsers are not configurable in this
       way.

       A solution for all browsers is something we call multi-port.   We  reconfigure  apache  to
       operate  on  ports  other  than the default of 80(http) or 443(https).  You need to pick a
       range, let’s say 30000 to 30010 in order to support 10 cameras.   We  add  lines  to  your
       zoneminder apache config file as follows:

       Listen 30000 Listen 30001 Listen 30002 Listen 30003 etc Listen 30010

       If  you are using virtualhosts, you will have to add these to the VirtualHost directive as
       well.

       Then in ZoneMinder config, Go Options -> Network and set MIN_STREAMING_PORT to 30000.  Now
       when  generating  urls  to  stream  images from ZoneMinder a port will be appended that is
       30000 + MonitorId, so Monitor 1 will stream from 30001 and so on.  This will allow Montage
       to stream from all monitors.

       Alternatively  if  you  are  in  fact  using  only  Firefox, you can increase the limit as
       follows:

       Enter about:config in the address bar

       scroll down to browser.cache.check_doc_frequency 3 change the 3 to a 1

          browser.cache.disk.enable True -> False
          network.http.max-connections-per-server -> put a value of 100
          network.http.max-persistent-connections-per-proxy -> 100 again
          network.http.max-persistent-connections-per-server -> 100 again

   I can’t see more than 6 monitors in montage on my browser
       Browsers such a Chrome and Safari only support up to 6 streams from the  same  domain.  To
       work  around  that,  take  a  look  at  the  multi-port  configuration  discussed  in  the
       MIN_STREAMING_PORT configuration in Options - Network

   Why is ZoneMinder using so much CPU?
       The various elements of ZoneMinder can be involved  in  some  pretty  intensive  activity,
       especially  while analysing images for motion. However generally this should not overwhelm
       your machine unless it is very old or underpowered.

       There are a number of specific reasons why processor loads can be high either by design or
       by accident. To figure out exactly what is causing it in your circumstances requires a bit
       of experimentation.

       The main causes are.

          • Using a video palette other than greyscale or RGB24.  This  can  cause  a  relatively
            minor  performance  hit,  though  still  significant. Although some cameras and cards
            require using planar palettes ZM currently doesn’t support this format internally and
            each frame is converted to an RGB representation prior to processing. Unless you have
            compelling reasons for using YUV or reduced RGB type palettes  such  as  hitting  USB
            transfer  limits I would experiment to see if RGB24 or greyscale is quicker. Put your
            monitors into ‘Monitor’ mode so that only the capture daemons are running and monitor
            the  process  load  of  these  (the  ‘zmc’  processes) using top. Try it with various
            palettes to see if it makes a difference.

          • Big image sizes. A image of 640x480 requires at least four times the processing of  a
            320x240  image.  Experiment  with  different  sizes  to  see what effect it may have.
            Sometimes a large image is just two interlaced smaller frames so has no real  benefit
            anyway.  This  is  especially  true for analog cameras/cards as image height over 320
            (NTSC) or 352 PAL) are invariably interlaced.

          • Capture frame rates. Unless there’s a compelling reason in your case there  is  often
            little  benefit  in running cameras at 25fps when 5-10fps would often get you results
            just as good. Try changing your monitor settings to limit your cameras to lower frame
            rates.  You  can  still  configure  ZM  to ignore these limits and capture as fast as
            possible when motion is detected.

          • Run function. Obviously running in Record or Mocord modes or in Modect with  lots  of
            events generates a lot of DB and file activity and so CPU and load will increase.

          • Basic  default  detection zones. By default when a camera is added one detection zone
            is added which covers the whole image with a  default  set  of  parameters.  If  your
            camera  covers a view in which various regions are unlikely to generate a valid alarm
            (ie the sky) then I would experiment with reducing the zone sizes or adding  inactive
            zones  to blank out areas you don’t want to monitor. Additionally the actual settings
            of the zone themselves may not be optimal. When doing motion detection the number  of
            changed  pixels  above  a threshold is examined, then this is filter, then contiguous
            regions are calculated to see if an alarm is generated. If  any  maximum  or  minimum
            threshold  is  exceeded  according  to your zone settings at any time the calculation
            stops. If your settings always result in the calculations going through to  the  last
            stage  before  being failed then additional CPU time is used unnecessarily. Make sure
            your maximum and minimumzone thresholds are set to sensible values and experiment  by
            switching  RECORD_EVENT_STATS  on and seeing what the actual values of alarmed pixels
            etc are during sample events.

          • Optimise your settings. After  you’ve  got  some  settings  you’re  happy  with  then
            switching  off  RECORD_EVENT_STATS  will  prevent the statistics being written to the
            database which saves some time. Other settings which  might  make  a  difference  are
            ZM_FAST_RGB_DIFFS and the JPEG_xxx_QUALITY ones.

       I’m  sure  there are other things which might make a difference such as what else you have
       running on the box and memory sizes (make sure there’s no swapping going on).  Also  speed
       of  disk  etc  will make some difference during event capture and also if you are watching
       the whole time then you may have a bunch of zms processes running also.

       I think the biggest factors are image size, colour depth and  capture  rate.  Having  said
       that  I  also don’t always know why you get certains results from ‘top’. For instance if I
       have a ‘zma’ daemon running for a monitor that is capturing an image. I’ve  commented  out
       the  actual  analysis  so  all  it’s doing is blending the image with the previous one. In
       colour mode this takes ~11 milliseconds per frame on my system and the camera is capturing
       at  ~10fps.  Using  ‘top’  this reports the process as using ~5% of CPU and permanently in
       R(un) state. Changing to greyscale mode the blending takes ~4msec (as you would expect  as
       this  is  roughly  a  third  of  11)  but  top  reports the process as now with 0% CPU and
       permanently in S(leep) state. So an actual CPU resource usage change  of  a  factor  of  3
       causes huge differences in reported CPU usage. I have yet to get to the bottom of this but
       I suspect it’s to do with scheduling somewhere along the line and that maybe the greyscale
       processing will fit into one scheduling time slice whereas the colour one won’t but I have
       no evidence of this yet!

   Why is the timeline view all messed up?
       The timeline view is a new view allowing you to see a graph of alarm  activity  over  time
       and  to  quickly  scan  and  home in on events of interest. However this feature is highly
       complex and still in beta. It is based extensively on HTML div  tags,  sometimes  lots  of
       them.  Whilst  FireFox is able to render this view successfully other browsers, particular
       Internet Explorer do not seem able to cope and so present a messed up view, either  always
       or when there are a lot of events.  Using the timeline view is only recommended when using
       FireFox, however even then there may be issues.

       This function has from time to time been corrupted in the SVN release  or  in  the  stable
       releases, try and reinstall from a fresh download.

   How much Hard Disk Space / Bandwidth do I need for ZM?
       Please see this online excel sheet. Note that this is just an estimate

       Or  go  to  this  link  for  the Axis bandwidth calculator. Although this is aimed at Axis
       cameras it still produces valid results for any kind of IP camera.

       As a quick guide I have 4 cameras at 320x240 storing 1 fps  except  during  alarm  events.
       After  1  week  60GB of space in the volume where the events are stored (/var/www/html/zm)
       has been used.

   When I try and run ZoneMinder I get lots of audit permission errors in the logs and  it  won’t
       start
       Many  Linux  distributions  nowadays  are  built  with security in mind. One of the latest
       methods of achieving this is via SELinux (Secure Linux) which controls who is able to  run
       what  in a more precise way then traditional accounting and file based permissions (link).
       If you are seeing entries in your system log like:
          Jun 11 20:44:02 kernel: audit(1150033442.443:226): avc: denied { read  }  for  pid=5068
          comm=”uptime”               name=”utmp”              dev=dm-0              ino=16908345
          scontext=user_u:system_r:httpd_sys_script_t   tcontext=user_u:object_r:initrc_var_run_t
          tclass=file

       then  it  is  likely  that your system has SELinux enabled and it is preventing ZoneMinder
       from performaing certain activities. You then  have  two  choices.  You  can  either  tune
       SELinux  to  permit the required operations or you can disable SELinux entirely which will
       permit ZoneMinder to run unhindered. Disabling SELinux is usually performed by editing its
       configuration  file  (e.g.,  /etc/selinux/config) and then rebooting. However if you run a
       public server you should read up on the risks associated with disabled Secure Linux before
       disabling it.

       Note  that SELinux may cause errors other than those listed above. If you are in any doubt
       then it can be worth disabling SELinux experimentally to see  if  it  fixes  your  problem
       before trying other solutions.

   How do I enable ZoneMinder’s security?
       In  the console, click on Options->System. Check the box next to ZM_OPT_USE_AUTH. You will
       immediately be asked to login. The  default  username  is  ‘admin’  and  the  password  is
       ‘admin’.

       To Manage Users: In main console, go to Options->Users.

       You  may  also  consider to use the web server security, for example, htaccess files under
       Apache scope; You may even  use  this  as  an  additional/redundant  security  on  top  of
       Zoneminders  built-in security features. Note that if you choose to enable webserver auth,
       zmNinja may have issues. Please read the zmNinja FAQ  on  basic  authentication  for  more
       information. Also please note that zmNinja does not support digest authentication.

   Managing system load (with IP Cameras in mind)
   Introduction
       Zoneminder  is  a  superb  application in every way, but it does a job that needs a lot of
       horsepower especially when using multiple IP cameras. IP Cams require an  extra  level  of
       processing  to  analogue  cards  as  the  jpg  or  mjpeg  images need to be decoded before
       analysing. This needs grunt. If you have lots of cameras, you need lots of grunt.

       Why do ZM need so much grunt?  Think what Zoneminder is actually doing. In modect mode  ZM
       is:  1.  Fetching  a  jpeg from the camera. (Either in single part or multipart stream) 2.
       Decoding the jpeg image.  3. Comparing the zoned  selections  to  the  previous  image  or
       images  and  applying  rules.   4.  If  in alarm state, writing that image to the disk and
       updating the mysql database.

       If you’re capturing at five frames per second, the above  is  repeated  five  times  every
       second,  multiplied  by  the number of cameras. Decoding the images is what takes the real
       power from the processor and this is the main reason why analogue cameras which present an
       image ready-decoded in memory take less work.

   How do I know if my computer is overloaded?
       If your CPU is running at 100% all the time, it’s probably overloaded (or running at exact
       optimisation). If the load is consistently high (over 10.0 for a  single  processor)  then
       Bad  Things  happen  - like lost frames, unrecorded events etc. Occasional peaks are fine,
       normal and nothing to worry about.

       Zoneminder runs on Linux, Linux measures system load using “load”,  which  is  complicated
       but  gives a rough guide on what the computer is doing at any given time. Zoneminder shows
       Load on the main page (top right) as well as disk space. Typing “uptime”  on  the  command
       line  will give a similar guide, but with three figures to give a fuller measure of what’s
       happening over a period of time but for the best guide to see  what’s  happening,  install
       “htop” - which gives easy to read graphs for load, memory and cpu usage.

       A  load  of  1.0  means the processor has “just enough to do right now”. Also worth noting
       that a load of 4.0 means exactly the same for a  quad  processor  machine  -  each  number
       equals  a single processor’s workload. A very high load can be fine on a computer that has
       a stacked workload - such as a machine sending out bulk emails, or working its way through
       a  knotty  problem;  it’ll  just  keep churning away until it’s done. However - Zoneminder
       needs to process information in real time so it can’t afford to stack its jobs,  it  needs
       to deal with them right away.

       For a better and full explanation of Load: Please read this

   My load is too high, how can I reduce it?
       (The  previous  documentation explained how to use turbo jpeg libraries as an optimization
       technique. These libraries have long been  part  of  standard  linux  distros  since  that
       article was authored and hence that section has been removed)

       Zoneminder is very tweakable and it’s possible to tune it to compromise. The following are
       good things to try, in no particular order;

          • If your camera allows you to change image size, think whether you can get  away  with
            smaller images. Smaller pics = less load. 320x240 is usually ok for close-up corridor
            shots.

          • Go Black and White. Colour pictures use twice to three  times  the  CPU,  memory  and
            diskspace but give little benefit to identification.

          • Reduce  frames per second. Halve the fps, halve the workload. If your camera supports
            fps throttling (Axis do), try that - saves ZM having to drop frames  from  a  stream.
            2-5 fps seems to be widely used.

          • Experiment with using jpeg instead of mjpeg. Some users have reported it gives better
            performance, but YMMV.

          • Tweak the zones. Keep them as small and as few as possible. Stick to one zone  unless
            you  really need more. Read this for an easy to understand explanation along with the
            official Zone guide.

          • Schedule. If you are running a linux system at near capacity, you’ll  need  to  think
            carefully about things like backups and scheduled tasks. updatedb - the process which
            maintains a file database so that ‘locate’ works quickly, is  normally  scheduled  to
            run  once  a day and if on a busy system can create a heavy increase on the load. The
            same is true for scheduled  backups,  especially  those  which  compress  the  files.
            Re-schedule these tasks to a time when the cpu is less likely to be busy, if possible
            -  and  also  use  the  “nice”  command  to  reduce  their  priority.  (crontab   and
            /etc/cron.daily/ are good places to start)

          • Reduce  clutter  on your PC. Don’t run X unless you really need it, the GUI is a huge
            overhead in both memory and cpu.

       More expensive options:

          • Increase RAM. If your system is having  to  use  disk  swap  it  will  HUGELY  impact
            performance  in  all  areas.  Again,  htop  is a good monitor - but first you need to
            understand that because Linux is using all the memory, it doesn’t mean  it  needs  it
            all  -  linux handles ram very differently to Windows/DOS and caches stuff. htop will
            show cached ram as a different colour in the memory graph.  Also  check  that  you’re
            actually  using  a high memory capable kernel - many kernels don’t enable high memory
            by default.

          • Faster CPU. Simple but effective. Zoneminder  also  works  very  well  with  multiple
            processor  systems  out  of  the  box (if SMP is enabled in your kernel). The load of
            different cameras is spread across the processors.

          • Try building Zoneminder with processor specific instructions that  are  optimised  to
            the  system  it  will  be  running  on, also increasing the optimisation level of GCC
            beyond -O2 will help.  This topic is beyond the scope of this document.

       Processor specific commands can be found in the GCC manual along with  some  more  options
       that may increase performance.

   What about disks and bandwidth?
       A  typical  100mbit  LAN will cope with most setups easily. If you’re feeding from cameras
       over smaller or internet links, obviously fps will be much lower.

       Disk and Bandwidth calculators are referenced in How much Hard Disk Space / Bandwidth do I
       need for ZM?.

   How do I build for X10 support?
       You  do  not  need to rebuild ZM for X10 support. You will need to install the perl module
       and switch on X10 in the options, then restart. Installing the perl module is  covered  in
       the README amongst other places but in summary, do:
          perl -MCPAN -eshell install X10::ActiveHome quit

   Extending Zoneminder
   How can I get ZM to do different things at different times of day or week?
       If  you want to configure ZoneMinder to do motion detection during the day and just record
       at night, for example, you will need to use ZoneMinder ‘run states’.  A  run  state  is  a
       particular configuration of monitor functions that you want to use at any time.

       To  save  a run state you should first configure your monitors for Modect, Record, Monitor
       etc as you would want them during one of the times of day. Then click on the running state
       link  at  the  top  of the Console view. This will usually say ‘Running’ or ‘Stopped’. You
       will then be able to save the current state and give it a name, ‘Daytime’ for example. Now
       configure  your  monitors how you would want them during other times of day and save that,
       for instance as ‘Nighttime’.

       Now you can switch between these two states by selecting them from  the  same  dialog  you
       saved  them, or from the command line from issue the command ‘’zmpkg.pl <run state>’’, for
       example ‘’zmpkg.pl Daytime’’.

       The final step you need to take, is scheduling the time the changes take effect. For  this
       you  can  use  cron.  A  simple entry to change to the Daylight state at at 8am and to the
       nighttime state at 8pm would be as follows,

          0 8 * * * root /usr/local/bin/zmpkg.pl Daytime
          0 20 * * * root /usr/local/bin/zmpkg.pl Nighttime

       On Ubuntu 7.04 and possibly others, look in  /usr/bin  not  just  /usr/local/bin  for  the
       zmpkg.pl file.

       Although  the  example above describes changing states at different times of day, the same
       principle can equally be applied to days of the week or other more arbitrary periods.

   How can I use ZoneMinder to trigger something else when there is an alarm?
       ZoneMinder includes a perl API which means you can create a script to interact with the ZM
       shared  memory  data and use it in your own scripts to react to ZM alarms or to trigger ZM
       to generate new alarms. Full details are in the README  or  by  doing  perldoc  ZoneMinder
       etc.

       ZoneMinder  provides  a  sample  alarm script called zmalarm.pl that you can refer to as a
       starting point.

   Trouble Shooting
       Here are some things that will help you track down whats  wrong.   This  is  also  how  to
       obtain the info that we need to help you on the forums.

   What logs should I check for errors?
       ZoneMinder  creates its own logs and are usually located in the /var/log/ directory. Refer
       to the logging discussion in Options - Logging for more details on where logs  are  stored
       and how to enable various log levels.

       Since  ZM is dependent on other components to work, you might not find errors in ZM but in
       the other components.

          */var/log/messages and/or /var/log/syslog
          */var/log/dmesg
          */var/log/httpd/error_log`` (RedHat/Fedora) or ``/var/log/apache2/error_log
          */var/log/mysqld.log`` (Errors here don't happen very often but just in case)

       If ZM is not functioning, you should always be able to find an error in at  least  one  of
       these logs. Use the [[tail]] command to get info from the logs. This can be done like so:
          tail -f /var/log/messages /var/log/httpd/error_log /var/log/zm/zm*.log

       This  will  append  any  data entered to any of these logs to your console screen (-f). To
       exit, hit [ctrl -c].

   How can I trouble shoot the hardware and/or software?
       Here are some  commands  to  get  information  about  your  hardware.  Some  commands  are
       distribution  dependent.   *  [[lspci]]  -vv  –  Returns  lots of detailed info. Check for
       conflicting interrupts or port assignments. You can sometimes alter interrupts/  ports  in
       bios. Try a different pci slot to get a clue if it is HW conflict (command provided by the
       pciutils package).  * [[scanpci]] -v  – Gives you information from your hardware  EPROM  *
       [[lsusb]]  -vv  –  Returns  lots  of detail about USB devices (camand provided by usbutils
       package).  * [[dmesg]] – Shows you how your hardware initialized (or didn’t)  on  boot-up.
       You will get the most use of this.  * [[v4l-info]] – to see how driver is talking to card.
       look for unusual values.  * [[modinfo bttv]] – some bttv driver stats.  * [[zmu]]  -m 0 -q
       -v  –  Returns  various  information regarding a monitor configuration.  * [[ipcs]] ``  --
       Provides information on the ipc facilities for which the calling process has read  access.
       *  ``[[ipcrm]]  ``   --  The  ipcrm  command  can be used to remove an IPC object from the
       kernel.  * ``cat /proc/interrupts  – This will dispaly what interrupts  your  hardware  is
       using.

   Why  am  I  getting  a  403  access  error  with  my  web  browser  when trying to access http
       //localhost/zm?
       The apache web server needs to have the right permissions and configuration to be able  to
       read   the  Zoneminder  files.  Check  the  forums  for  solution,  and  edit  the  apache
       configuration and change directory permissions to  give  apache  the  right  to  read  the
       Zoneminder  files.  Depending  on your Zoneminder configuration, you would use the zm user
       and group that Zoneminder was built with, such as wwwuser and www.

   Why am I getting broken images when trying to view events?
       Zoneminder and the Apache web server need to have the right permissions. Check this  forum
       topic and similar ones:

   I can review events for the current day, but ones from yesterday and beyond error out
       If  you’ve  checked that the www-data user has permissions to the storage folders, perhaps
       your php.ini’s timezone setting is incorrect.  They  _must_  match  for  certain  playback
       functions.

       If you’re using Linux, this can be found using the following command:

          timedatectl | grep "Time zone"

       If using FreeBSD, you can use this one-liner:

          cd /usr/share/zoneinfo/ && find * -type f -exec cmp -s {} /etc/localtime \; -print;

       Once you know what timezone your system is set to make sure you set the right time zone in
       ZM (Available in Options->System->TimeZone)

   Why is the image from my color camera appearing in black and white?
       If you recently upgraded to zoneminder 1.26, there is a per camera option that defaults to
       black  and  white and can be mis-set if your upgrade didn’t happen right. See this thread:
       https://forums.zoneminder.com/viewtopic.php?f=30&t=21344

       This may occur if you have a  NTSC  analog  camera  but  have  configured  the  source  in
       ZoneMinder  as  PAL  for  the Device Format under the source tab.  You may also be mislead
       because zmu can report the video port as being PAL  when  the  camera  is  actually  NTSC.
       Confirm  the  format  of  your  analog  camera  by checking it’s technical specifications,
       possibly found with the packaging it came in, on the manufacturers website, or even on the
       retail  website  where you purchased the camera.  Change the Device Format setting to NTSC
       and set it to the lowest resolution of 320 x 240.  If you have confirmed that  the  camera
       itself is NTSC format, but don’t get a picture using the NTSC setting, consider increasing
       the shared memory ‘’’kernel.shmall’’’ and ‘’’kernel.shmmax’’’ settings in /etc/sysctl.conf
       to  a  larger  value such as 268435456.  This is also the reason you should start with the
       320x240 resolution, so as to  minimize  the  potential  of  memory  problems  which  would
       interfere  with  your  attempts  to  troubleshoot  the device format issue.  Once you have
       obtained a picture in the monitor using the NTSC format,  then  you  can  experiment  with
       raising the resolution.

   Why do I only see blue screens with a timestamp when monitoring my camera?
       If  this camera is attached to a capture card, then you may have selected the wrong Device
       Source or Channel when configuring the monitor in the ZoneMinder console.  If you  have  a
       capture  card  with  2  D-sub  style  inputs(looks  like a VGA port) to which you attach a
       provided splitter that splits off multiple cables, then the splitter may  be  attached  to
       the  wrong  port.  For example, PV-149 capture cards have two D-sub style ports labeled as
       DB1 and DB2, and come packaged with a connector for one of these ports that splits into  4
       BNC  connecters.  The initial four video ports are available with the splitter attached to
       DB1.

   Why do I only see black screens with a timestamp when monitoring my camera?
       In the monitor windows where you see the black screen with a  timestamp,  select  settings
       and enter the Brightness, Contrast, Hue, and Color settings reported for the device by zmu
       -d <device_path> -q -v.  32768 may be appropriate values to try for these settings.  After
       saving the settings, select Settings again to confirm they saved successfully.

   How do I repair the MySQL Database?
       There  is  two ways to go about this. In most cases you can run from the command prompt ->
       mysqlcheck --all-databases --auto-repair -p your_database_password -u your_databse_user

       If that does not work then you will have to make sure that ZoneMinder is stopped then  run
       the  following  (nothing should be using the database while running this and you will have
       to adjust for your correct path if it is different):

       myisamchk --silent --force --fast --update-state -O key_buffer=64M -O  sort_buffer=64M  -O
       read_buffer=1M -O write_buffer=1M /var/lib/mysql/*/*.MYI

   How do I repair the MySQL Database when the cli fails?
       In  Ubuntu,  the commands listed above do not seem to work.  However, actually doing it by
       hand from within MySQL does.  (But that is beyond the scope of this  document)   But  that
       got  me  thinking…   And phpmyadmin does work.  Bring up a terminal.  sudo apt-get install
       phpmyadmin

       Now   go   to   http://zoneminder_IP/   and   stop   the   ZM   service.    Continue    to
       http://zoneminder_IP/phpmyadmin  and  select  the  zoneminder database.  Select and tables
       marked ‘in use’ and pick the action ‘repare’ to fix.  Restart the zoneminder service  from
       the  web  browser.   Remove  or  disable the phpmyadmin tool, as it is not always the most
       secure thing around, and opens your database wide to any  skilled  hacker.   sudo  apt-get
       remove phpmyadmin

   I upgraded by distribution and ZM stopped working
       Some  possibilities  (Incomplete  list  and subject to correction) [[/usr/local/bin/zmfix:
       /usr/lib/libmysqlclient.so.15:   version    `MYSQL_5.0'    not    found    (required    by
       /usr/local/bin/zmfix)]]   ::  Solution:  Recompile and reinstall Zoneminder.  Any time you
       update a major version that ZoneMinder depends on, you need to recompile ZoneMinder.

   Zoneminder doesn’t start automatically on boot
       Check the list for log entries like “zmfix[766]:  ERR  [Can’t  connect  to  server:  Can’t
       connect  to  local MySQL server through socket ‘/var/run/mysqld/mysqld.sock’ (2)] “.  What
       can happen is that zoneminder is started too quickly after Mysql and tries to contact  the
       database  server  before  it’s ready. Zoneminder gets no answer and aborts.  August 2010 -
       Ubuntu upgrades seem to be leaving several systems in this state. One way around  this  is
       to  add  a  delay  to  the  zoneminder  startup  script allowing Mysql to finish starting.
       “Simply adding ‘sleep 15’ in the line above ‘zmfix -a’ in the /etc/init.d/zoneminder  file
       fixed my ZoneMinder startup problems!” - credit to Pada.

   Remote Path setup for Panasonic and other Camera
       On  adding or editing the source you can select the preset link for the parameters for the
       specified camera .  In version 1.23.3  presets  for  BTTV,Axis,Panasonic,GadSpot,VEO,  and
       BlueNet  are  available  .  Selecting  the presets  ZM fills up the required value for the
       remote path variable

   Why do I get repeated/ mixed/unstable/ blank monitors on bt878-like cards (a.k.a. PICO 2000)
       Please have a check at [[Pico2000]];

   What causes “Invalid JPEG file structure: two SOI markers” from zmc (1.24.x)
       Some settings that used to be global only are now per camera.  On the Monitor Source  tab,
       if  you  are using Remote Protocol  “HTTP” and Remote Method “Simple”, try changing Remote
       Method to “Regexp”.

   Miscellaneous
   I see ZoneMinder is licensed under the GPL. What does that allow or restrict me in doing  with
       ZoneMinder?
       The  ZoneMinder  license  is described at the end of the documentation and consists of the
       following section
          This program is free software; you can redistribute it and/or modify it under the terms
          of  the GNU General Public License as published by the Free Software Foundation; either
          version 2 of the License, or (at your option) any later version.

          This program is distributed in the hope  that  it  will  be  useful,  but  WITHOUT  ANY
          WARRANTY;  without  even  the  implied  warranty  of  MERCHANTABILITY  or FITNESS FOR A
          PARTICULAR PURPOSE. See the GNU General Public License for more details.

       This means that ZoneMinder is  licensed  under  the  terms  described  here.  There  is  a
       comprehensive  FAQ  covering  the  GPL at https://www.gnu.org/licenses/gpl-faq.html but in
       essence you are allowed to redistribute or modify GPL licensed software provided that  you
       release your distribution or modifications freely under the same terms. You are allowed to
       sell systems based on GPL software. You are not allowed to restrict or reduce  the  rights
       of  GPL  software  in  your  distribution  however.  Of  course  if  you  are  just making
       modifications for your system locally you  are  not  releasing  changes  so  you  have  no
       obligations  in  this  case. I recommend reading the GPL FAQ for more in-depth coverage of
       this issue.

   Can I use ZoneMinder as part of my commercial product?
       The GPL license allows you produce systems based on GPL  software  provided  your  systems
       also  adhere  to  that  license and any modifications you make are also released under the
       same terms.  The GPL does not permit you to include ZoneMinder in proprietary systems (see
       https://www.gnu.org/licenses/gpl-faq.html#GPLInProprietarySystem for details). If you wish
       to include ZoneMinder in this kind of system then you  will  need  to  license  ZoneMinder
       under  different  terms.  This  is  sometimes possible and you will need to contact me for
       further details in these circumstances.

   I am having issues with zmNinja and/or Event Notification Server
       zmNinja and the Event Notification Server are 3rd party solutions. The developer maintains
       exhaustive documentation and FAQs. Please direct your questions there.

CONTRIBUTING

       Source hosted at GitHub Report issues/questions/feature requests on GitHub Issues

       Pull  requests  are  very  welcome!  If  you  would  like to contribute, please follow the
       following steps.

       • Fork the repo

       • Open an issue at our GitHub Issues Tracker. Describe the bug that you’ve found,  or  the
         feature which you’re asking for. Jot down the issue number (e.g. 456)

       • Create your feature branch (git checkout -b 456-my-new-feature)

       • Commit  your  changes  (git  commit  -m  'Added  some feature') It is preferred that you
         ‘commit early and often’ instead of bunching all changes into a single commit.

       • Push your branch to your fork on github (git push origin 456-my-new-feature)

       • Create new Pull Request

       • The team will then review, discuss and hopefully merge your changes.

       Welcome to ZoneMinder’s documentation. Please navigate to one of the links below.

       If you are facing issues that are not covered in the documentation, please  feel  free  to
       check  the  ZoneMinder Forums or join the ZoneMinder-Chat Slack channel if you prefer real
       time interaction.

       User Guide
              Guide to setting up ZoneMinder for the first time and detailed guides for using the
              ZoneMinder front end.

       API    Information on using the CakePHP based API for interfacing to ZoneMinder

       FAQ    Frequently Asked Questions

       Contributing
              How  to  contribute  to ZoneMinder. As a community project we always need help, you
              don’t need to be a coder to test or update documentation.

       Event Notification Server and Machine Learning hooks
              Documentation for the 3rd party Event Notification Server and Machine Learning  for
              Object/People/Face detection.

       • IndexModule IndexSearch Page

AUTHOR

       https://github.com/ZoneMinder/ZoneMinder/graphs/contributors

COPYRIGHT

       2022, https://github.com/ZoneMinder/ZoneMinder/graphs/contributors

                                           Aug 08, 2022                             ZONEMINDER(1)