Provided by: dlt-daemon_2.18.6-2.1_amd64 bug

NAME

       dlt.conf - DLT daemon configuration file

DESCRIPTION

       The  DLT  daemon  is  the central application which gathers logs and traces from different
       applications, stores them temporarily or permanently and transfers them to  a  DLT  client
       application, which could run directly on the GENIVI system or more likely on some external
       tester device.

       The configuration file dlt.conf allows to configure the different runtime behaviour of the
       dlt-daemon.  It is loaded during startup of dlt-daemon.

GENERAL OPTIONS

   Verbose
       Start  daemon  in debug mode, so that all internal debug information is printed out on the
       console.

              Default: Off

   Daemonize
       If set to 1 DLT daemon is started in background as daemon.  This option is only needed  in
       System V init systems.  In systemd based startup systems the daemon is started by spawning
       own process.

              Default: 0

   SendSerialHeader
       If set to 1 DLT daemon sends each DLT message to the client  with  prepanding  the  serial
       header “DLS0x01”.

              Default: 0

   SendContextRegistration
       If  set  to  1  each  context  which  is  registered from an application in the DLT daemon
       generates a message to inform the DLT client about the new context.

              Default: 1

   SendMessageTime
       If set to 1 DLt daemon sends each second a DLT control message  to  the  client  with  the
       current timestamp from the system.

              Default: 0

   ECUId
       This value sets the ECU Id, which is sent with each DLT message.

              Default: ECU1

   SharedMemorySize
       This  value  sets  the  size  of the shared memory, which is used to exchange DLT messages
       between applications and daemon.  This value is  defined  in  bytes.   If  this  value  is
       changed the system must be rebooted to take effect.

              Default: 100000

   PersistanceStoragePath
       This  is  the  directory  path,  where  the  DLT  daemon stores its runtime configuration.
       Runtime configuration includes stored log levels, trace status and changed logging mode.

              Default: /tmp

   LoggingMode
       The logging console for internal logging of dlt-daemon.  0 = log to stdout,  1  =  log  to
       syslog, 2 = log to file (see LoggingFilename), 3 = log to stderr

              Default: 0

   LoggingLevel
       The  internal  log  level,  up  to  which logs are written.  LOG_EMERG = 0, LOG_ALERT = 1,
       LOG_CRIT = 2, LOG_ERR = 3, LOG_WARNING = 4, LOG_NOTICE = 5, LOG_INFO = 6, LOG_DEBUG = 7

              Default: 6

   LoggingFilename
       If LoggingMode is set to 2 logs are written to the file path given here.

              Default: /tmp/dlt.log

   TimeOutOnSend
       Socket timeout in seconds for sending to clients.

              Default: 4

   RingbufferMinSize
       The minimum size of the Ringbuffer, used for storing temporary DLT messages, until  client
       is connected.

              Default: 500000

   RingbufferMaxSize
       The  max  size of the Ringbuffer, used for storing temporary DLT messages, until client is
       connected.

              Default: 10000000

   RingbufferStepSize
       The step size the Ringbuffer is increased, used for storing temporary DLT messages,  until
       client is connected.

              Default: 500000

   ContextLogLevel
       Initial  log-level  that  is  sent  when  an  application  registers.   DLT_LOG_OFF  =  0,
       DLT_LOG_FATAL = 1, DLT_LOG_ERROR = 2, DLT_LOG_WARN = 3, DLT_LOG_INFO = 4, DLT_LOG_DEBUG  =
       5, DLT_LOG_VERBOSE = 6

              Default: 4

   ContextTraceStatus
       Initial  trace-status  that is sent when an application registers.  DLT_TRACE_STATUS_OFF =
       0, DLT_TRACE_STATUS_ON = 1

              Default: 0

   ForceContextLogLevelAndTraceStatus
       Force log level  and  trace  status  of  contexts  to  not  exceed  “ContextLogLevel”  and
       “ContextTraceStatus”.   If  set to 1 (ON) whenever a context registers or changes the log-
       level it has to be lower or equal to ContextLogLevel.

              Default: 0

   InjectionMode
       If set to 0, the injection mode (see here) is disabled.

              Default: 1

GATEWAY CONFIGURATION

   GatewayMode
       Enable Gateway mode

              Default: 0

   GatewayConfigFile
       Read gateway configuration from another location

              Default: /etc/dlt_gateway.conf

Permission configuration

       DLT daemon runs with e.g.  User: genivi_dlt Group: genivi_dlt

       DLT user applications  run  with  different  user  and  group  than  dlt-daemon  but  with
       supplimentory group: dlt_user_apps_group

       /dlt  FIFO  will be created by dlt-daemon with User: genivi_dlt Group: dlt_user_apps_group
       Permission: 620

       so that only dlt-daemon can read and only processes in dlt_user_apps_group can write.

       /dltpipes  will  be  created  by  dlt-daemon  with  User:  genivi_dlt  Group:   genivi_dlt
       Permission: 3733 (i.e Sticky bit and SGID turned on)

       /dltpipes/dlt  FIFO  will  be  created  by  dlt  application  (user lib) with User: Group:
       genivi_dlt (inherited from dltpipes/ due to SGID) Permission: 620

       Thus DLT user  applications  (and  also  or  attackers)  can  create  the  dlt  FIFO  (for
       communication from dlt-daemon to DLT user application) under /dltpipes/.  Since sticky bit
       is set the applications who creates the FIFO can only rename/delete it.

       Since SGID of /dltpipes is set the group of dlt FIFO will be genivi_dlt which enables  dlt
       daemon to have write permission on all the dlt FIFO.

       One  dlt  user application cannot access dlt FIFO created by other dlt user application(if
       they run with different user).

       Owner group of daemon FIFO directory(Default: /tmp/dlt) (If not set, primary group of dlt-
       daemon  process  is  used).   Application  should  have write permission to this group for
       tracing into dlt.  For this opton to work, dlt-daemon  should  have  this  group  in  it’s
       supplementary group.

   DaemonFifoGroup
       Owner  group  of daemon FIFO directory (If not set, primary group of dlt-daemon process is
       used) Application should have write permission to this group for tracing into dlt For this
       opton to work, dlt-daemon should have this group in it’s Supplementary group

              Default: group of dlt-daemon process (/tmp/dlt)

CONTROL APPLICATION OPTIONS

   ControlSocketPath
       Path to control socket.

              Default: /tmp/dlt-ctrl.sock

OFFLINE TRACE OPTIONS

   OfflineTraceDirectory
       Store DLT messages to local directory, if not set offline Trace is off.

              Default: /tmp

   OfflineTraceFileSize
       This  value  defines  the  max  size of a offline trace file, if offline trace is enabled.
       This value is defined in bytes.  If the files  size  of  the  current  used  log  file  is
       exceeded, a new log file is created.

              Default: 1000000

   OfflineTraceMaxSize
       This  value  defines the max offline Trace memory size, if offline trace is enabled.  This
       value is defined in bytes.  If the overall offline trace size is excedded, the oldest  log
       files are deleted, until a new trace file fits the overall offline trace max size.

              Default: 4000000

   OfflineTraceFileNameTimestampBased
       Filename timestamp based or index based.  1 = timestamp based, 0 = index based

              Default: Function is disabled

LOCAL CONSOLE OUTPUT OPTIONS

   PrintASCII
       Prints each received DLT message from the application in ASCII to the local console.  This
       option should only be anabled for debugging purpose.

              Default: Function is disabled

   PrintHex
       Prints each received DLT message from the application in ASCII to the local console.   The
       payload is printed in Hex.  This option should only be anabled for debugging purpose.

              Default: Function is disabled

   PrintHeadersOnly
       Prints each received DLT message from the application in ASCII to the local console.  Only
       the header is printed.  This option should only be anabled for debugging purpose.

              Default: Function is disabled

SERIAL CLIENT OPTIONS

   RS232DeviceName
       If this value is set to a serial device name, e.g. /dev/ttyS0, a serial port is  used  for
       logging to a client.

              Default: Serial port for logging is disabled

   RS232Baudrate
       The  used  serial baud rate, if serial loggin is enabled.  The RS232DeviceName must be set
       to enable serial logging.

              Default: 115200

   RS232SyncSerialHeader
       If serial logging is enabled, each received DLT message is checked  to  contain  a  serial
       header.  If the DLT message contains no serial header, the message is ignored.

              Default: Function is disabled

TCP CLIENT OPTIONS

   TCPSyncSerialHeader
       Each  received  DLT message on a TCP connection is checked to contain a serial header.  If
       the DLT message contains no serial header, the message is ignored.

              Default: Function is disabled

ECU SOFTWARE VERSION OPTIONS

   SendECUSoftwareVersion
       Periodically send ECU version info.  0 = disabled, 1 = enabled

              Default: Function is disabled

PathToECUSoftwareVersion

       Absolute path to file storing version information - if disabled the DLT  version  will  be
       send.

              Default: Function is disabled.

TIMEZONE INFO OPTIONS

SendTimezone

       Periodically send timezone info.  0 = disabled, 1 = enabled

              Default: Function is disabled

OFFLINE LOGSTORAGE OPTIONS

   OfflineLogstorageMaxDevices
       Maximum  devices  to  be  used  as  offline  logstorage  devices.   0  =  disabled,  1  ..
       DLT_OFFLINE_LOGSTORAGE_MAX_DEVICES

              Default: 0 (Function is disabled)

   OfflineLogstorageDirPath
       Path to store DLT offline log storage messages.

              Default: off

   OfflineLogstorageTimestamp
       Appends timestamp in log file name.  0 = disabled, 1 = enabled

              Default: 0

   OfflineLogstorageDelimiter
       Appends delimiter in log file name, only punctuation characters allowed.

              Default: _

   OfflineLogstorageMaxCounter
       Wrap around value for log file count in file name.

              Default: UINT_MAX

   OfflineLogstorageCacheSize
       Maximal used memory for log storage cache in KB.

              Default: 30000 KB

   UDPConnectionSetup
       Enable or disable UDP connection.  0 = disabled, 1 = enabled

   UDPMulticastIPAddress
       The address on which daemon multicasts the log messages

   UDPMulticastIPPort
       The Multicase IP port.  Default: 3491

AUTHOR

       Alexander Wenzel (alexander.aw.wenzel (at) bmw (dot) de)

COPYRIGHT

       Copyright  (C)  2015  BMW  AG.   License  MPL-2.0:  Mozilla  Public  License  version  2.0
       <http://mozilla.org/MPL/2.0/>.

BUGS

       See Github issue: <https://github.com/GENIVI/dlt-daemon/issues>

SEE ALSO

       dlt-daemon(1), dlt-system(1)

                                                                                      DLT.CONF(5)