Provided by: infiniband-diags_42.0-1_amd64 bug

NAME

       ibsysstat - system status on an InfiniBand address

SYNOPSIS

       ibsysstat [options] <dest lid | guid> [<op>]

DESCRIPTION

       ibsysstat  uses  vendor  mads  to  validate connectivity between IB nodes and obtain other
       information about the IB node. ibsysstat is run as client/server. Default  is  to  run  as
       client.

OPTIONS

       Current supported operations:

          ping \- verify connectivity to server (default)
          host \- obtain host information from server
          cpu  \- obtain cpu information from server

       -o, --oui
              use specified OUI number to multiplex vendor mads

       -S, --Server
              start in server mode (do not return)

   Addressing Flags
       -G, --Guid     The address specified is a Port GUID

       -L, --Lid   The address specified is a LID

       -s, --sm_port <smlid>     use 'smlid' as the target lid for SA queries.

   Port Selection flags
       -C, --Ca <ca_name>    use the specified ca_name.

       -P, --Port <ca_port>    use the specified ca_port.

   Local port Selection
       Multiple  port/Multiple CA support: when no IB device or port is specified (see the "local
       umad parameters" below), the libibumad library selects the port to use  by  the  following
       criteria:

          1. the first port that is ACTIVE.

          2. if not found, the first port that is UP (physical link up).

          If  a  port  and/or CA name is specified, the libibumad library attempts to fulfill the
          user request, and will fail if it is not possible.

          For example:

              ibaddr                 # use the first port (criteria #1 above)
              ibaddr -C mthca1       # pick the best port from "mthca1" only.
              ibaddr -P 2            # use the second (active/up) port from the first available IB device.
              ibaddr -C mthca0 -P 2  # use the specified port only.

   Debugging flags
       -d     raise the IB debugging level.  May be used several times (-ddd or -d -d -d).

       -e     show send and receive errors (timeouts and others)

       -h, --help      show the usage message

       -v, --verbose
              increase the application verbosity level.  May be used several times (-vv or -v  -v
              -v)

       -V, --version     show the version info.

   Configuration flags
       -t, --timeout <timeout_ms> override the default timeout for the solicited mads.

       --config, -z  <config_file> Specify alternate config file.
          Default: /etc/infiniband-diags/ibdiag.conf

FILES

   CONFIG FILE
       /etc/infiniband-diags/ibdiag.conf

       A  global  config  file  is provided to set some of the common options for all tools.  See
       supplied config file for details.

AUTHOR

       Hal Rosenstock
              < halr@voltaire.com >

                                            2017-08-21                               IBSYSSTAT(8)