Provided by: erlang-manpages_24.3.4.1+dfsg-1_all bug

NAME

       ct - Main user interface for the Common Test framework.

DESCRIPTION

       Main user interface for the Common Test framework.

       This  module  implements  the command-line interface for running tests and basic functions
       for Common Test case issues, such as configuration and logging.

       Test Suite Support Macros

       The config macro is defined in ct.hrl. This macro is to be used  to  retrieve  information
       from  the Config variable sent to all test cases. It is used with two arguments; the first
       is the name of the configuration variable to retrieve, the second is the  Config  variable
       supplied to the test case.

       Possible configuration variables include:

         * data_dir - Data file directory

         * priv_dir - Scratch file directory

         * Whatever added by init_per_suite/1 or init_per_testcase/2 in the test suite.

DATA TYPES

       handle() = pid()

              The identity (handle) of a connection.

       config_key() = atom()

              A configuration key which exists in a configuration file

       target_name() = atom()

              A  name  and  association  to  configuration  data  introduced  through  a  require
              statement,     or     a      call      to      ct:require/2,      for      example,
              ct:require(mynodename,{node,[telnet]}).

       key_or_name() = config_key() | target_name()

       conn_log_options() = [conn_log_option()]

              Options  that  can  be given to the cth_conn_log hook, which is used for logging of
              NETCONF and Telnet connections. See ct_netconfc or ct_telnet  for  description  and
              examples of how to use this hook.

       conn_log_option() = {log_type,conn_log_type()} | {hosts,[key_or_name()]}

       conn_log_type() = raw | pretty | html | silent

       conn_log_mod() = ct_netconfc | ct_telnet

EXPORTS

       abort_current_testcase(Reason) -> ok | {error, ErrorReason}

              Types:

                 Reason = term()
                 ErrorReason = no_testcase_running | parallel_group

              Aborts  the  currently executing test case. The user must know with certainty which
              test case is currently executing. The function is therefore only safe to call  from
              a function that has been called (or synchronously invoked) by the test case.

              Reason, the reason for aborting the test case, is printed in the test case log.

       add_config(Callback, Config) -> ok | {error, Reason}

              Types:

                 Callback = atom()
                 Config = string()
                 Reason = term()

              Loads configuration variables using the specified callback module and configuration
              string. The callback module is to be either loaded or present  in  the  code  path.
              Loaded    configuration   variables   can   later   be   removed   using   function
              ct:remove_config/2.

       break(Comment) -> ok | {error, Reason}

              Types:

                 Comment = string()
                 Reason = {multiple_cases_running, TestCases} | 'enable break with  release_shell
                 option'
                 TestCases = [atom()]

              Cancels any active timetrap and pauses the execution of the current test case until
              the user calls function continue/0. The user can then interact with the Erlang node
              running  the tests, for example, for debugging purposes or for manually executing a
              part of the test case. If a parallel group is executing, ct:break/2 is to be called
              instead.

              A  cancelled timetrap is not automatically reactivated after the break, but must be
              started explicitly with ct:timetrap/1.

              In order for the break/continue functionality to work, Common Test must release the
              shell process controlling stdin. This is done by setting start option release_shell
              to true. For details, see section Running Tests from the Erlang Shell  or  from  an
              Erlang Program in the User's Guide.

       break(TestCase, Comment) -> ok | {error, Reason}

              Types:

                 TestCase = atom()
                 Comment = string()
                 Reason = 'test case not running' | 'enable break with release_shell option'

              Works the same way as ct:break/1, only argument TestCase makes it possible to pause
              a test case executing in a parallel group. Function ct:continue/1 is to be used  to
              resume execution of TestCase.

              For details, see ct:break/1.

       capture_get() -> ListOfStrings

              Types:

                 ListOfStrings = [string()]

              Equivalent to ct:capture_get([default]).

       capture_get(ExclCategories) -> ListOfStrings

              Types:

                 ExclCategories = [atom()]
                 ListOfStrings = [string()]

              Returns  and  purges the list of text strings buffered during the latest session of
              capturing  printouts  to  stdout.  Log  categories  that  are  to  be  ignored   in
              ListOfStrings  can  be  specified  with  ExclCategories. If ExclCategories = [], no
              filtering takes place.

              See also ct:capture_start/0, ct:capture_stop/0, ct:log/3.

       capture_start() -> ok

              Starts capturing all text strings printed to stdout during execution  of  the  test
              case.

              See also ct:capture_get/1, ct:capture_stop/0.

       capture_stop() -> ok

              Stops capturing text strings (a session started with capture_start/0).

              See also ct:capture_get/1, ct:capture_start/0.

       comment(Comment) -> ok

              Types:

                 Comment = term()

              Prints  the  specified  Comment in the comment field in the table on the test suite
              result page.

              If called several times, only the last comment is printed.  The  test  case  return
              value {comment,Comment} overwrites the string set by this function.

       comment(Format, Args) -> ok

              Types:

                 Format = string()
                 Args = list()

              Prints  the  formatted  string  in the comment field in the table on the test suite
              result page.

              Arguments Format and Args are used in a  call  to  io_lib:format/2  to  create  the
              comment  string.  The  behavior  of  comment/2  is  otherwise  the same as function
              ct:comment/1.

       continue() -> ok

              This function must be called to continue after a test  case  (not  executing  in  a
              parallel group) has called function ct:break/1.

       continue(TestCase) -> ok

              Types:

                 TestCase = atom()

              This  function  must be called to continue after a test case has called ct:break/2.
              If the paused test case, TestCase, executes in a  parallel  group,  this  function,
              rather than continue/0, must be used to let the test case proceed.

       decrypt_config_file(EncryptFileName, TargetFileName) -> ok | {error, Reason}

              Types:

                 EncryptFileName = string()
                 TargetFileName = string()
                 Reason = term()

              Decrypts EncryptFileName, previously generated with ct:encrypt_config_file/2,3. The
              original file contents is saved in the target file. The encryption key,  a  string,
              must  be  available  in  a  text file named .ct_config.crypt, either in the current
              directory, or the home directory of the user (it is searched for in that order).

       decrypt_config_file(EncryptFileName, TargetFileName, KeyOrFile) -> ok | {error, Reason}

              Types:

                 EncryptFileName = string()
                 TargetFileName = string()
                 KeyOrFile = {key, string()} | {file, string()}
                 Reason = term()

              Decrypts EncryptFileName, previously generated with ct:encrypt_config_file/2,3. The
              original  file  contents  is  saved  in the target file. The key must have the same
              value as that used for encryption.

       encrypt_config_file(SrcFileName, EncryptFileName) -> ok | {error, Reason}

              Types:

                 SrcFileName = string()
                 EncryptFileName = string()
                 Reason = term()

              Encrypts the source configuration file with DES3  and  saves  the  result  in  file
              EncryptFileName.  The  key,  a  string,  must  be  available  in  a text file named
              .ct_config.crypt, either in the current directory, or the  home  directory  of  the
              user (it is searched for in that order).

              For  information  about using encrypted configuration files when running tests, see
              section Encrypted Configuration Files in the User's Guide.

              For details on DES3 encryption/decryption, see application Crypto.

       encrypt_config_file(SrcFileName, EncryptFileName, KeyOrFile) -> ok | {error, Reason}

              Types:

                 SrcFileName = string()
                 EncryptFileName = string()
                 KeyOrFile = {key, string()} | {file, string()}
                 Reason = term()

              Encrypts the source configuration file with DES3 and saves the result in the target
              file EncryptFileName. The encryption key to use is either the value in {key,Key} or
              the value stored in the file specified by {file,File}.

              For information about using encrypted configuration files when running  tests,  see
              section Encrypted Configuration Files in the User's Guide.

              For details on DES3 encryption/decryption, see application Crypto.

       fail(Reason) -> ok

              Types:

                 Reason = term()

              Terminates a test case with the specified error Reason.

       fail(Format, Args) -> ok

              Types:

                 Format = string()
                 Args = list()

              Terminates  a  test  case  with an error message specified by a format string and a
              list of values (used as arguments to io_lib:format/2).

       get_config(Required) -> Value

              Equivalent to ct:get_config(Required, undefined, []).

       get_config(Required, Default) -> Value

              Equivalent to ct:get_config(Required, Default, []).

       get_config(Required, Default, Opts) -> ValueOrElement

              Types:

                 Required = KeyOrName | {KeyOrName, SubKey} | {KeyOrName, SubKey, SubKey}
                 KeyOrName = atom()
                 SubKey = atom()
                 Default = term()
                 Opts = [Opt] | []
                 Opt = element | all
                 ValueOrElement = term() | Default

              Reads configuration data values.

              Returns the matching  values  or  configuration  elements,  given  a  configuration
              variable key or its associated name (if one has been specified with ct:require/2 or
              a require statement).

              Example:

              Given the following configuration file:

               {unix,[{telnet,IpAddr},
                      {user,[{username,Username},
                             {password,Password}]}]}.

              Then:

               ct:get_config(unix,Default) -> [{telnet,IpAddr},
                {user, [{username,Username}, {password,Password}]}]
               ct:get_config({unix,telnet},Default) -> IpAddr
               ct:get_config({unix,user,username},Default) -> Username
               ct:get_config({unix,ftp},Default) -> Default
               ct:get_config(unknownkey,Default) -> Default

              If a configuration variable key has been associated with a name (by ct:require/2 or
              a require statement), the name can be used instead of the key to read the value:

               ct:require(myuser,{unix,user}) -> ok.
               ct:get_config(myuser,Default) -> [{username,Username}, {password,Password}]

              If  a configuration variable is defined in multiple files, use option all to access
              all possible values. The values are returned in a list. The order of  the  elements
              corresponds to the order that the configuration files were specified at startup.

              If  configuration  elements (key-value tuples) are to be returned as result instead
              of values, use  option  element.  The  returned  elements  are  then  on  the  form
              {Required,Value}.

              See also ct:get_config/1, ct:get_config/2, ct:require/1, ct:require/2.

       get_event_mgr_ref() -> EvMgrRef

              Types:

                 EvMgrRef = atom()

              Gets  a  reference  to the Common Test event manager. The reference can be used to,
              for example, add a user-specific event handler while tests are running.

              Example:

               gen_event:add_handler(ct:get_event_mgr_ref(), my_ev_h, [])

       get_progname() -> string()

              Returns the command used to start this Erlang instance. If this  information  could
              not be found, the string "no_prog_name" is returned.

       get_status() -> TestStatus | {error, Reason} | no_tests_running

              Types:

                 TestStatus = [StatusElem]
                 StatusElem  =  {current,  TestCaseInfo}  |  {successful,  Successful} | {failed,
                 Failed} | {skipped, Skipped} | {total, Total}
                 TestCaseInfo = {Suite, TestCase} | [{Suite, TestCase}]
                 Suite = atom()
                 TestCase = atom()
                 Successful = integer()
                 Failed = integer()
                 Skipped = {UserSkipped, AutoSkipped}
                 UserSkipped = integer()
                 AutoSkipped = integer()
                 Total = integer()
                 Reason = term()

              Returns status of ongoing test. The returned list contains information about  which
              test  case  is  executing  (a  list  of  cases  when  a parallel test case group is
              executing), as well as counters for successful, failed,  skipped,  and  total  test
              cases so far.

       get_target_name(Handle) -> {ok, TargetName} | {error, Reason}

              Types:

                 Handle = handle()
                 TargetName = target_name()

              Returns the name of the target that the specified connection belongs to.

       get_testspec_terms() -> TestSpecTerms | undefined

              Types:

                 TestSpecTerms = [{Tag, Value}]
                 Value = [term()]

              Gets a list of all test specification terms used to configure and run this test.

       get_testspec_terms(Tags) -> TestSpecTerms | undefined

              Types:

                 Tags = [Tag] | Tag
                 Tag = atom()
                 TestSpecTerms = [{Tag, Value}] | {Tag, Value}
                 Value = [{Node, term()}] | [term()]
                 Node = atom()

              Reads  one or more terms from the test specification used to configure and run this
              test. Tag is any valid test specification  tag,  for  example,  label,  config,  or
              logdir.  User-specific  terms are also available to read if option allow_user_terms
              is set.

              All value tuples returned, except user terms, have the node name as first element.

              To read test terms, use Tag = tests (rather than suites, groups, or  cases).  Value
              is      then      the      list      of      all      tests     on     the     form
              [{Node,Dir,[{TestSpec,GroupsAndCases1},...]},...],    where    GroupsAndCases     =
              [{Group,[Case]}] | [Case].

       get_timetrap_info() -> {Time, {Scaling,ScaleVal}}

              Types:

                 Time = integer() | infinity
                 Scaling = true | false
                 ScaleVal = integer()

              Reads  information  about  the  timetrap  set  for  the  current test case. Scaling
              indicates if Common Test will attempt to  compensate  timetraps  automatically  for
              runtime  delays introduced by, for example, tools like cover. ScaleVal is the value
              of the current scaling multipler (always 1 if scaling is disabled). Note  the  Time
              is not the scaled result.

       get_verbosity(Category) -> Level | undefined

              Types:

                 Category = default | atom()
                 Level = integer()

              This  function  returns the verbosity level for the specified logging category. See
              the  User's Guide for details. Use the value default to read the general  verbosity
              level.

       install(Opts) -> ok | {error, Reason}

              Types:

                 Opts = [Opt]
                 Opt = {config, ConfigFiles} | {event_handler, Modules} | {decrypt, KeyOrFile}
                 ConfigFiles = [ConfigFile]
                 ConfigFile = string()
                 Modules = [atom()]
                 KeyOrFile = {key, Key} | {file, KeyFile}
                 Key = string()
                 KeyFile = string()

              Installs configuration files and event handlers.

              Run this function once before the first test.

              Example:

               install([{config,["config_node.ctc","config_user.ctc"]}])

              This function is automatically run by program ct_run.

       listenv(Telnet) -> [Env]

              Types:

                 Telnet = term()
                 Env = {Key, Value}
                 Key = string()
                 Value = string()

              Performs  command listenv on the specified Telnet connection and returns the result
              as a list of key-value pairs.

       log(Format) -> ok

              Equivalent to ct:log(default, 50, Format, [], []).

       log(X1, X2) -> ok

              Types:

                 X1 = Category | Importance | Format
                 X2 = Format | FormatArgs

              Equivalent to ct:log(Category, Importance, Format, FormatArgs, []).

       log(X1, X2, X3) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs | Opts

              Equivalent to ct:log(Category, Importance, Format, FormatArgs, Opts).

       log(X1, X2, X3, X4) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs
                 X4 = FormatArgs | Opts

              Equivalent to ct:log(Category, Importance, Format, FormatArgs, Opts).

       log(Category, Importance, Format, FormatArgs, Opts) -> ok

              Types:

                 Category = atom()
                 Importance = integer()
                 Format = string()
                 FormatArgs = list()
                 Opts = [Opt]
                 Opt = {heading,string()} | no_css | esc_chars

              Prints from a test case to the log file.

              This function is meant for printing a string directly from a test case to the  test
              case log file.

              Default  Category  is  default,  default Importance is ?STD_IMPORTANCE, and default
              value for FormatArgs is [].

              For details on Category, Importance and the no_css option, see section   Logging  -
              Categories and Verbosity Levels in the User's Guide.

              Common  Test  will  not  escape  special  HTML  characters (<, > and &) in the text
              printed with this function, unless the esc_chars option is used.

       make_priv_dir() -> ok | {error, Reason}

              Types:

                 Reason = term()

              If the test is started with option create_priv_dir set to manual_per_tc,  in  order
              for  the test case to use the private directory, it must first create it by calling
              this function.

       notify(Name, Data) -> ok

              Types:

                 Name = atom()
                 Data = term()

              Sends an asynchronous notification of type Name with Datato the Common  Test  event
              manager. This can later be caught by any installed event manager.

              See also gen_event(3erl).

       pal(Format) -> ok

              Equivalent to ct:pal(default, 50, Format, [], []).

       pal(X1, X2) -> ok

              Types:

                 X1 = Category | Importance | Format
                 X2 = Format | FormatArgs

              Equivalent to ct:pal(Category, Importance, Format, FormatArgs, []).

       pal(X1, X2, X3) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs | Opts

              Equivalent to ct:pal(Category, Importance, Format, FormatArgs, Opts).

       pal(X1, X2, X3, X4) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs
                 X4 = FormatArgs | Opts

              Equivalent to ct:pal(Category, Importance, Format, FormatArgs, Opts).

       pal(Category, Importance, Format, FormatArgs, Opts) -> ok

              Types:

                 Category = atom()
                 Importance = integer()
                 Format = string()
                 FormatArgs = list()
                 Opts = [Opt]
                 Opt = {heading,string()} | no_css

              Prints and logs from a test case.

              This  function  is  meant  for printing a string from a test case, both to the test
              case log file and to the console.

              Default Category is default, default Importance  is  ?STD_IMPORTANCE,  and  default
              value for FormatArgs is [].

              For  details  on  Category  and  Importance,  see  section Logging - Categories and
              Verbosity Levels in the User's Guide.

              Note that special characters in the text (<, > and &) will  be  escaped  by  Common
              Test before the text is printed to the log file.

       parse_table(Data) -> {Heading, Table}

              Types:

                 Data = [string()]
                 Heading = tuple()
                 Table = [tuple()]

              Parses the printout from an SQL table and returns a list of tuples.

              The  printout  to  parse  is  typically  the result of a select command in SQL. The
              returned Table is a list of tuples, where each tuple is a row in the table.

              Heading is a tuple of strings representing the  headings  of  each  column  in  the
              table.

       print(Format) -> ok

              Equivalent to ct:print(default, 50, Format, [], []).

       print(X1, X2) -> ok

              Types:

                 X1 = Category | Importance | Format
                 X2 = Format | FormatArgs

              Equivalent to ct:print(Category, Importance, Format, FormatArgs, []).

       print(X1, X2, X3) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs | Opts

              Equivalent to ct:print(Category, Importance, Format, FormatArgs, Opts).

       print(X1, X2, X3, X4) -> ok

              Types:

                 X1 = Category | Importance
                 X2 = Importance | Format
                 X3 = Format | FormatArgs
                 X4 = FormatArgs | Opts

              Equivalent to ct:print(Category, Importance, Format, FormatArgs, Opts).

       print(Category, Importance, Format, FormatArgs, Opts) -> ok

              Types:

                 Category = atom()
                 Importance = integer()
                 Format = string()
                 FormatArgs = list()
                 Opts = [Opt]
                 Opt = {heading,string()}

              Prints from a test case to the console.

              This function is meant for printing a string from a test case to the console.

              Default  Category  is  default,  default Importance is ?STD_IMPORTANCE, and default
              value for FormatArgs is [].

              For details on Category and  Importance,  see  section  Logging  -  Categories  and
              Verbosity Levels in the User's Guide.

       reload_config(Required) -> ValueOrElement | {error, Reason}

              Types:

                 Required = KeyOrName | {KeyOrName, SubKey} | {KeyOrName, SubKey, SubKey}
                 KeyOrName = atom()
                 SubKey = atom()
                 ValueOrElement = term()

              Reloads configuration file containing specified configuration key.

              This function updates the configuration data from which the specified configuration
              variable was read, and returns the (possibly) new value of this variable.

              If some variables were present in the configuration, but are not loaded using  this
              function,  they  are  removed  from  the  configuration  table  together with their
              aliases.

       remaining_test_procs() -> {TestProcs,SharedGL,OtherGLs}

              Types:

                 TestProcs = [{pid(),GL}]
                 GL = pid()
                 SharedGL = pid()
                 OtherGLs = [pid()]

              This function will return the identity of test- and group leader processes that are
              still  running at the time of this call. TestProcs are processes in the system that
              have a Common Test IO process as group leader. SharedGL is the central Common  Test
              IO  process,  responsible for printing to log files for configuration functions and
              sequentially executing test cases. OtherGLs are Common Test IO processes that print
              to log files for test cases in parallel test case groups.

              The  process  information  returned  by  this  function  may  be used to locate and
              terminate remaining processes after tests have  finished  executing.  The  function
              would typically by called from Common Test Hook functions.

              Note  that  processes  that execute configuration functions or test cases are never
              included in TestProcs.  It  is  therefore  safe  to  use  post  configuration  hook
              functions  (such  as post_end_per_suite, post_end_per_group, post_end_per_testcase)
              to terminate all processes in TestProcs that have the current group leader  process
              as its group leader.

              Note  also  that the shared group leader (SharedGL) must never be terminated by the
              user, only by Common Test. Group leader processes for  parallel  test  case  groups
              (OtherGLs) may however be terminated in post_end_per_group hook functions.

       remove_config(Callback, Config) -> ok

              Types:

                 Callback = atom()
                 Config = string()
                 Reason = term()

              Removes configuration variables (together with their aliases) that were loaded with
              specified callback module and configuration string.

       require(Required) -> ok | {error, Reason}

              Types:

                 Required = Key | {Key, SubKeys} | {Key, SubKey, SubKeys}
                 Key = atom()
                 SubKeys = SubKey | [SubKey]
                 SubKey = atom()

              Checks if the required configuration is available. Arbitrarily deep tuples  can  be
              specified as Required. Only the last element of the tuple can be a list of SubKeys.

              Example 1. Require the variable myvar:

               ok = ct:require(myvar).

              In this case the configuration file must at least contain:

               {myvar,Value}.

              Example 2. Require key myvar with subkeys sub1 and sub2:

               ok = ct:require({myvar,[sub1,sub2]}).

              In this case the configuration file must at least contain:

               {myvar,[{sub1,Value},{sub2,Value}]}.

              Example 3. Require key myvar with subkey sub1 with subsub1:

               ok = ct:require({myvar,sub1,sub2}).

              In this case the configuration file must at least contain:

               {myvar,[{sub1,[{sub2,Value}]}]}.

              See also ct:get_config/1, ct:get_config/2, ct:get_config/3, ct:require/2.

       require(Name, Required) -> ok | {error, Reason}

              Types:

                 Name = atom()
                 Required = Key | {Key, SubKey} | {Key, SubKey, SubKey}
                 SubKey = Key
                 Key = atom()

              Checks  if  the  required  configuration  is  available  and  gives  it a name. The
              semantics for Required is the same as in ct:require/1 except that a list of SubKeys
              cannot be specified.

              If  the  requested  data is available, the subentry is associated with Name so that
              the value of the element can be read with ct:get_config/1,2 provided Name  is  used
              instead of the whole Required term.

              Example:

              Require one node with a Telnet connection and an FTP connection. Name the node a:

               ok = ct:require(a,{machine,node}).

              All  references  to  this node can then use the node name. For example, a file over
              FTP is fetched like follows:

               ok = ct:ftp_get(a,RemoteFile,LocalFile).

              For this to work, the configuration file must at least contain:

               {machine,[{node,[{telnet,IpAddr},{ftp,IpAddr}]}]}.

          Note:
              The behavior of this function changed radically in Common Test 1.6.2. To keep  some
              backwards compatability, it is still possible to do:
              ct:require(a,{node,[telnet,ftp]}).
              This  associates  the  name  a with the top-level node entry. For this to work, the
              configuration file must at least contain:
              {node,[{telnet,IpAddr},{ftp,IpAddr}]}.

              See also ct:get_config/1, ct:get_config/2, ct:get_config/3, ct:require/1.

       run(TestDirs) -> Result

              Types:

                 TestDirs = TestDir | [TestDir]

              Runs all test cases in all suites in the specified directories.

              See also ct:run/3.

       run(TestDir, Suite) -> Result

              Runs all test cases in the specified suite.

              See also ct:run/3.

       run(TestDir, Suite, Cases) -> Result

              Types:

                 TestDir = string()
                 Suite = atom()
                 Cases = atom() | [atom()]
                 Result = [TestResult] | {error, Reason}

              Runs the specified test cases.

              Requires that ct:install/1 has been run first.

              Suites (*_SUITE.erl) files must be stored in TestDir or  TestDir/test.  All  suites
              are compiled when the test is run.

       run_test(Opts) -> Result

              Types:

                 Opts = [OptTuples]
                 OptTuples  =  {dir,  TestDirs}  | {suite, Suites} | {group, Groups} | {testcase,
                 Cases} | {spec, TestSpecs} | {join_specs, Bool}  |  {label,  Label}  |  {config,
                 CfgFiles}  |  {userconfig,  UserConfig}  |  {allow_user_terms,  Bool} | {logdir,
                 LogDir}  |  {silent_connections,  Conns}  |  {stylesheet,  CSSFile}  |   {cover,
                 CoverSpecFile}  |  {cover_stop,  Bool}  |  {step,  StepOpts}  |  {event_handler,
                 EventHandlers}   |   {include,    InclDirs}    |    {auto_compile,    Bool}    |
                 {abort_if_missing_suites,    Bool}    |   {create_priv_dir,   CreatePrivDir}   |
                 {multiply_timetraps, M} | {scale_timetraps, Bool} |  {repeat,  N}  |  {duration,
                 DurTime}   |   {until,   StopTime}   |   {force_stop,   ForceStop}  |  {decrypt,
                 DecryptKeyOrFile} | {refresh_logs, LogDir} | {logopts,  LogOpts}  |  {verbosity,
                 VLevels}  |  {basic_html,  Bool}  |  {esc_chars,  Bool} | {keep_logs,KeepSpec} |
                 {ct_hooks, CTHs} | {enable_builtin_hooks, Bool} | {release_shell, Bool}
                 TestDirs = [string()] | string()
                 Suites = [string()] | [atom()] | string() | atom()
                 Cases = [atom()] | atom()
                 Groups = GroupNameOrPath | [GroupNameOrPath]
                 GroupNameOrPath = [atom()] | atom() | all
                 TestSpecs = [string()] | string()
                 Label = string() | atom()
                 CfgFiles = [string()] | string()
                 UserConfig = [{CallbackMod, CfgStrings}] | {CallbackMod, CfgStrings}
                 CallbackMod = atom()
                 CfgStrings = [string()] | string()
                 LogDir = string()
                 Conns = all | [atom()]
                 CSSFile = string()
                 CoverSpecFile = string()
                 StepOpts = [StepOpt] | []
                 StepOpt = config | keep_inactive
                 EventHandlers = EH | [EH]
                 EH = atom() | {atom(), InitArgs} | {[atom()], InitArgs}
                 InitArgs = [term()]
                 InclDirs = [string()] | string()
                 CreatePrivDir = auto_per_run | auto_per_tc | manual_per_tc
                 M = integer()
                 N = integer()
                 DurTime = string(HHMMSS)
                 StopTime = string(YYMoMoDDHHMMSS) | string(HHMMSS)
                 ForceStop = skip_rest | Bool
                 DecryptKeyOrFile = {key, DecryptKey} | {file, DecryptFile}
                 DecryptKey = string()
                 DecryptFile = string()
                 LogOpts = [LogOpt]
                 LogOpt = no_nl | no_src
                 VLevels = VLevel | [{Category, VLevel}]
                 VLevel = integer()
                 Category = atom()
                 KeepSpec = all | pos_integer()
                 CTHs = [CTHModule | {CTHModule, CTHInitArgs}]
                 CTHModule = atom()
                 CTHInitArgs = term()
                 Result = {Ok, Failed, {UserSkipped,  AutoSkipped}}  |  TestRunnerPid  |  {error,
                 Reason}
                 Ok = integer()
                 Failed = integer()
                 UserSkipped = integer()
                 AutoSkipped = integer()
                 TestRunnerPid = pid()
                 Reason = term()

              Runs  tests as specified by the combination of options in Opts. The options are the
              same as those used with program ct_run, see Run Tests  from  Command  Line  in  the
              ct_run manual page.

              Here  a  TestDir  can  be  used  to  point out the path to a Suite. Option testcase
              corresponds to option -case in program ct_run.  Configuration  files  specified  in
              Opts are installed automatically at startup.

              TestRunnerPid is returned if release_shell == true. For details, see ct:break/1.

              Reason indicates the type of error encountered.

       run_testspec(TestSpec) -> Result

              Types:

                 TestSpec = [term()]
                 Result = {Ok, Failed, {UserSkipped, AutoSkipped}} | {error, Reason}
                 Ok = integer()
                 Failed = integer()
                 UserSkipped = integer()
                 AutoSkipped = integer()
                 Reason = term()

              Runs a test specified by TestSpec. The same terms are used as in test specification
              files.

              Reason indicates the type of error encountered.

       set_verbosity(Category, Level) -> ok

              Types:

                 Category = default | atom()
                 Level = integer()

              Use this function to set, or modify, the verbosity level for  a  logging  category.
              See  the   User's  Guide  for  details.  Use  the  value default to set the general
              verbosity level.

       sleep(Time) -> ok

              Types:

                 Time = {hours, Hours} | {minutes, Mins} | {seconds, Secs} | Millisecs | infinity
                 Hours = integer()
                 Mins = integer()
                 Secs = integer()
                 Millisecs = integer() | float()

              This function, similar to timer:sleep/1 in STDLIB, suspends the  test  case  for  a
              specified   time.   However,   this   function   also   multiplies  Time  with  the
              multiply_timetraps value (if set) and under certain circumstances  also  scales  up
              the time automatically if scale_timetraps is set to true (default is false).

       start_interactive() -> ok

              Starts Common Test in interactive mode.

              From  this  mode, all test case support functions can be executed directly from the
              Erlang shell. The interactive mode can also be started from  the  OS  command  line
              with ct_run -shell [-config File...].

              If  any  functions (for example, Telnet or FTP) using "required configuration data"
              are to be called from the Erlang shell, configuration data must first  be  required
              with ct:require/2.

              Example:

               > ct:require(unix_telnet, unix).
               ok
               > ct_telnet:open(unix_telnet).
               {ok,<0.105.0>}
               > ct_telnet:cmd(unix_telnet, "ls .").
               {ok,["ls","file1  ...",...]}

       step(TestDir, Suite, Case) -> Result

              Types:

                 Case = atom()

              Steps through a test case with the debugger.

              See also ct:run/3.

       step(TestDir, Suite, Case, Opts) -> Result

              Types:

                 Case = atom()
                 Opts = [Opt] | []
                 Opt = config | keep_inactive

              Steps  through  a test case with the debugger. If option config has been specified,
              breakpoints are also set on the configuration functions in Suite.

              See also ct:run/3.

       stop_interactive() -> ok

              Exits the interactive mode.

              See also ct:start_interactive/0.

       sync_notify(Name, Data) -> ok

              Types:

                 Name = atom()
                 Data = term()

              Sends a synchronous notification of type Name with Data to the  Common  Test  event
              manager. This can later be caught by any installed event manager.

              See also gen_event(3erl).

       testcases(TestDir, Suite) -> Testcases | {error, Reason}

              Types:

                 TestDir = string()
                 Suite = atom()
                 Testcases = list()
                 Reason = term()

              Returns all test cases in the specified suite.

       timetrap(Time) -> ok

              Types:

                 Time = {hours, Hours} | {minutes, Mins} | {seconds, Secs} | Millisecs | infinity
                 | Func
                 Hours = integer()
                 Mins = integer()
                 Secs = integer()
                 Millisecs = integer()
                 Func = {M, F, A} | function()
                 M = atom()
                 F = atom()
                 A = list()

              Sets a new timetrap for the running test case.

              If the argument is Func, the timetrap is triggered when this function returns. Func
              can  also  return  a  new  Time  value, which in that case is the value for the new
              timetrap.

       userdata(TestDir, Suite) -> SuiteUserData | {error, Reason}

              Types:

                 TestDir = string()
                 Suite = atom()
                 SuiteUserData = [term()]
                 Reason = term()

              Returns any data specified with tag userdata in the list of  tuples  returned  from
              suite/0.

       userdata(TestDir, Suite, Case::GroupOrCase) -> TCUserData | {error, Reason}

              Types:

                 TestDir = string()
                 Suite = atom()
                 GroupOrCase = {group, GroupName} | atom()
                 GroupName = atom()
                 TCUserData = [term()]
                 Reason = term()

              Returns  any  data  specified with tag userdata in the list of tuples returned from
              Suite:group(GroupName) or Suite:Case().