Provided by: pcp_5.3.7-1_amd64 bug

NAME

       pcp-dstat - pcp-dstat configuration file

DESCRIPTION

       pcp-dstat  is  a  customizable  performance  metrics  reporting tool.  It has a ``plugin''
       architecture, where a set of pre-defined plugins  offer  small  sets  of  columnar  metric
       reports,  and pcp-dstat command line options select which of these plugins are used in the
       generated report.

       Each plugin is defined in a section of a configuration file.  A typical installation  will
       provide many configuration files, and often multiple sections (plugins) within each file.

       Configuration  files  are  read  from both a system directory and the users home directory
       ($PCP_SYSCONF_DIR/dstat and $HOME/.pcp/dstat).

FILE FORMAT

       The configuration files have an ini-style syntax  consisting  of  sections  (plugins)  and
       options  within sections.  A section begins with the name of the plugin in square brackets
       and continues until the next section begins.  An example section with two options follows:

           [plugin]
           option = value
           metric.option = value2

       A line comment starts with a hash sign (``#'') or a semicolon  (``;'').   Inline  comments
       are not supported.

       There  are  some  options  which  apply  to  the  plugin  as a whole, and anything else is
       considered to be a column definition.  Column definitions map directly to  individual  PCP
       metrics.

   The [plugin] options
       label (string)
           The  overall  title  to  be used for this plugin.  In the special case of metrics with
           instances being reported as a group (see grouptype below) this string may contain  the
           %I  pattern,  which  will  be substituted with the name of the instance - refer to the
           cpu, disk,  net  and  int(errupts)  plugins  for  examples  of  this  special  syntax.
           Undefined by default, set automatically to the section (plugin) name.

       width (integer)
           The column width used for metrics in this plugin.  The default is 5.

       precision (integer)
           The  maximum  precision  to  be used when reporting columns in floating point for this
           plugin.  Undefined by default, set automatically based on width.

       printtype (character)
           Indicates the reporting style for metric values in this plugin.  Possible settings are
           d(ecimal), f(loat), p(ercent), s(tring), b(its), t(ime).  By default a setting will be
           used based on the metric type and semantic - refer to PMAPI(3) for further details  of
           PCP metric metadata.

       colorstep (integer)
           Indicates  a  ``step'' at which the next color will be transitioned to, when reporting
           metric values.  As metric values change on each  sample,  the  colorstep  is  used  to
           determine  the  increments  beyond  which  a new color is to be selected.  Defaults to
           1000.

       grouptype (integer)
           For plugins with metrics sharing the same instance domain, it is possible  to  request
           more  complex  grouping  behaviour.   The  default  behaviour  is  to not use instance
           grouping, and to report each instance of the metric in a  separate  column  (the  load
           plugin is an example of this, using the kernel.all.load metric).

           The  grouping  can  be  set  at  three  distinct levels - 1, 2 or 3.  Level 1 displays
           instances of metrics only (no totals) - this is the  equivalent  of  using  the  --cpu
           plugin  on the pcp-dstat command line with specific processors' utilization displayed,
           e.g. displaying CPU numbers 4, 5 and 12 (-C  4,5,12).   Level  2  displays  the  total
           column - the sum of all instances for the specified metric(s) in this plugin.  Level 3
           is a combination of both modes, for example using  the  pcp-dstat  --cpu  plugin  with
           options -C 4,5,12,total.

       instances (comma-separated-value string)
           Defines  the  instances  to  be reported for the metric.  The default is to report all
           instances for set-values metrics.

       cullinsts (regex pattern)
           An optional regular expression that can be used to  cull  metric  instances  from  the
           aggregation  ('total')  in  generated  reports.   For  example it is common to exclude
           loopback devices from the network interface  reports,  this  is  achieved  using  this
           option.  Default is to report on all instances (no culling).

   The [plugin] metrics
       Each  plugin must have at least one metric associated with it.  Any key that is not one of
       the above global plugin options is considered to be a metric  specification  or  a  metric
       option.  These keys define the metrics and their report formatting.

       First  and  foremost, each column is typically represented by an individual metric (if the
       metric is set-valued - i.e. it has instances - this  will  result  in  multiple  columns).
       This  is  specified by a new key (column) being set to a metric specification.  The column
       (key) name is an arbitrary word using alphabetic characters.  The metric specification  is
       any   PCP   metric  name  or  derived  metric  specification,  allowing  basic  arithmetic
       calculations to be used to form this individual column.   The  derived  metric  syntax  is
       described on the pmRegisterDerived(3) manual page.

       Some  examples  of  both forms of metric specification are given below in the ``EXAMPLES''
       section.  Once a column has been associated with a metric, other options specific to  that
       column can be set using a dot-separated syntax.

       Metric options

       metric.label
           The  subtitle to be used for the reported values of this metric.  The default label is
           the column name from the configuration file.

           When set-valued PCP metrics  (i.e.  with  instances)  are  being  used,  it  is  often
           convenient  to  specify  either  the  instance number or instance name in the heading.
           This is achieved using format specifiers - ``%d'' or ``%i'' for instance numbers (e.g.
           replaced  by  ``6''  for the sixth processor), and ``%s'' or ``%I'' for instance names
           (e.g. replaced by ``eth0'' for the ethernet interface).  Available instance names  for
           any metric can be discovered via the pminfo(1) or pmprobe(1) commands.

       metric.width
           The column width to be used when reporting values for this metric.

       metric.unit (string)
           Defines  the  unit/scale  conversion for the metric.  Needs to be dimension-compatible
           and is used with non-string metrics.  For allowed values, see pmrep(1).

       metric.type (string)
           If set to raw rate conversion for the metric will be disabled.

       metric.precision (integer)
           Defines precision for floating point values.

       metric.limit (string)
           Defines value limit filter for numeric metric values.

EXAMPLES

       The following example defines a virtual filesystem plugin, with two columns, defined using
       three  PCP  metrics  -  vfs.files.count, vfs.inodes.count and vfs.inodes.free.  The inodes
       metrics are combined using the derived metric notation.

           [vfs]
           width = 6
           label = filesystem
           files = vfs.files.count
           inode = vfs.inodes.count - vfs.inodes.free
           inode.label = inodes

       The system default pcp-dstat plugin files contain many more examples.

FILES

       $HOME/.pcp/dstat/
              private per-user configuration files

       $PCP_SYSCONF_DIR/dstat/
              system-wide configuration files

PCP ENVIRONMENT

       Environment variables with the prefix PCP_ are used to parameterize the file and directory
       names used by PCP.  On each installation, the file /etc/pcp.conf contains the local values
       for these variables.  The $PCP_CONF  variable  may  be  used  to  specify  an  alternative
       configuration file, as described in pcp.conf(5).

       For environment variables affecting PCP tools, see pmGetOptions(3).

SEE ALSO

       PCPIntro(1),  pcp-dstat(1),  pminfo(1),  pmprobe(1),  pmrep(1), PMAPI(3), pmGetOptions(3),
       pmRegisterDerived(3) and pmrep.conf(5).