Provided by: libopm-simulators-bin_2022.10+ds-1build2_amd64 bug

NAME

       flow - Eclipse compatible parallel reservoir simulator

SYNOPSIS

       flow [OPTIONS] [ECL_DECK_FILENAME]

DESCRIPTION

       Flow,  an  advanced  reservoir  simulator  for ECL-decks provided by the Open Porous Media
       project.

   Recognized options:
       -h,--help
              Print this help message and exit

       --help-all
              Print all parameters, including obsolete, hidden and deprecated ones.

       --accelerator-mode=STRING
              Use GPU (cusparseSolver or openclSolver) or FPGA (fpgaSolver) as the linear solver,
              usage: '--accelerator-mode=[none|cusparse|opencl|fpga|amgcl]'. Default: "none"

       --allow-distributed-wells=BOOLEAN
              Allow  the  perforations  of  a  well  to  be  distributed  to interior of multiple
              processes. Default: false

       --alternative-well-rate-init=BOOLEAN
              Use alternative well rate initialization procedure. Default: true

       --bda-device-id=INTEGER
              Choose device ID for cusparseSolver or openclSolver, use 'nvidia-smi'  or  'clinfo'
              to determine valid IDs. Default: 0

       --continue-on-convergence-error=BOOLEAN
              Continue  with a non-converged solution instead of giving up if we encounter a time
              step size smaller than the minimum time step size. Default: false

       --cpr-max-ell-iter=INTEGER
              MaxIterations of the elliptic pressure part of the cpr solver. Default: 20

       --cpr-reuse-interval=INTEGER
              Reuse preconditioner interval. Used when  CprReuseSetup  is  set  to  4,  then  the
              preconditioner  will  be  fully  recreated  instead of reused every N linear solve,
              where N is this parameter. Default: 10

       --cpr-reuse-setup=INTEGER
              Reuse preconditioner setup. Valid options are 0: recreate  the  preconditioner  for
              every  linear  solve,  1:  recreate once every timestep, 2: recreate if last linear
              solve took  more  than  10  iterations,  3:  never  recreate,  4:  recreated  every
              CprReuseInterval. Default: 3

       --dbhp-max-rel=SCALAR
              Maximum relative change of the bottom-hole pressure in a single iteration. Default:
              1

       --dp-max-rel=SCALAR
              Maximum relative change of pressure in a single iteration. Default: 0.3

       --ds-max=SCALAR
              Maximum absolute change of any saturation in a single iteration. Default: 0.2

       --dwell-fraction-max=SCALAR
              Maximum absolute change of a well's volume fraction in a single iteration. Default:
              0.2

       --ecl-deck-file-name=STRING
              The name of the file which contains the ECL deck to be simulated. Default: ""

       --ecl-enable-drift-compensation=BOOLEAN
              Enable  partial  compensation  of systematic mass losses via the source term of the
              next time step. Default: true

       --ecl-output-double-precision=BOOLEAN
              Tell the output writer to use double  precision.  Useful  for  'perfect'  restarts.
              Default: false

       --ecl-output-interval=INTEGER
              The  number  of  report  steps  that  ought to be skipped between two writes of ECL
              results. Default: -1

       --ecl-strict-parsing=BOOLEAN
              Use strict mode for parsing -  all  errors  are  collected  before  the  applicaton
              exists. Default: false

       --edge-weights-method=INTEGER
              Choose edge-weighing strategy: 0=uniform, 1=trans, 2=log(trans). Default: 1

       --enable-adaptive-time-stepping=BOOLEAN
              Use adaptive time stepping between report steps. Default: true

       --enable-async-ecl-output=BOOLEAN
              Write  the  ECL-formated  results  in  a  non-blocking  way (i.e., using a separate
              thread). Default: true

       --enable-async-vtk-output=BOOLEAN
              Dispatch a separate thread to write the VTK output. Default: true

       --enable-dry-run=STRING
              Specify if the simulation ought to be  actually  run,  or  just  pretended  to  be.
              Default: "auto"

       --enable-ecl-output=BOOLEAN
              Write  binary  output  which  is  compatible with the commercial Eclipse simulator.
              Default: true

       --enable-esmry=BOOLEAN
              Write ESMRY file for fast loading of summary data. Default: false

       --enable-logging-fallout-warning=BOOLEAN
              Developer option to see whether logging was on non-root processors. In that case it
              will be appended to the *.DBG or *.PRT files. Default: false

       --enable-opm-rst-file=BOOLEAN
              Include  OPM-specific  keywords  in  the  ECL restart file to enable restart of OPM
              simulators from these files. Default: false

       --enable-storage-cache=BOOLEAN
              Store previous storage terms and avoid re-calculating them. Default: true

       --enable-terminal-output=BOOLEAN
              Print high-level information about  the  simulation's  progress  to  the  terminal.
              Default: true

       --enable-tuning=BOOLEAN
              Honor some aspects of the TUNING keyword. Default: false

       --enable-vtk-output=BOOLEAN
              Global switch for turning on writing VTK files. Default: false

       --enable-well-operability-check=BOOLEAN
              Enable the well operability checking. Default: true

       --enable-well-operability-check-iter=BOOLEAN
              Enable the well operability checking during iterations. Default: false

       --enable-write-all-solutions=BOOLEAN
              Write all solutions to disk instead of only the ones for the report steps. Default:
              false

       --force-disable-fluid-in-place-output=BOOLEAN
              Do not print fluid-in-place values after each report step even if requested by  the
              deck. Default: false

       --force-disable-resv-fluid-in-place-output=BOOLEAN
              Do  not  print reservoir volumes values after each report step even if requested by
              the deck. Default: false

       --fpga-bitstream=STRING
              Specify   the   bitstream   file   for   fpgaSolver   (including   path),    usage:
              '--fpga-bitstream=<filename>'. Default: ""

       --full-time-step-initially=BOOLEAN
              Always attempt to finish a report step using a single substep. Default: false

       --ignore-keywords=STRING
              List  of  Eclipse  keywords  which  should  be  ignored. As a ':' separated string.
              Default: ""

       --ilu-fillin-level=INTEGER
              The fill-in level of the linear solver's ILU preconditioner. Default: 0

       --ilu-redblack=BOOLEAN
              Use red-black partitioning for the ILU preconditioner. Default: false

       --ilu-relaxation=SCALAR
              The relaxation factor of the linear solver's ILU preconditioner. Default: 0.9

       --ilu-reorder-spheres=BOOLEAN
              Whether to reorder the entries of the matrix in the red-black ILU preconditioner in
              spheres  starting  at  an edge. If false the original ordering is preserved in each
              color. Otherwise why try to ensure D4  ordering  (in  a  2D  structured  grid,  the
              diagonal elements are consecutive). Default: false

       --initial-time-step-in-days=SCALAR
              The size of the initial time step in days. Default: 1

       --linear-solver=STRING
              Configuration  of  solver.  Valid  options  are:  ilu0 (default), cpr (an alias for
              cpr_trueimpes),  cpr_quasiimpes,  cpr_trueimpes  or  amg.  Alternatively,  you  can
              request  a  configuration  to be read from a JSON file by giving the filename here,
              ending with '.json.'. Default: "ilu0"

       --linear-solver-ignore-convergence-failure=BOOLEAN
              Continue with the simulation like nothing happened after the linear solver did  not
              converge. Default: false

       --linear-solver-max-iter=INTEGER
              The maximum number of iterations of the linear solver. Default: 200

       --linear-solver-reduction=SCALAR
              The  minimum  reduction  of  the  residual  which  the  linear solver must achieve.
              Default: 0.01

       --linear-solver-restart=INTEGER
              The number of iterations after which GMRES is restarted. Default: 40

       --linear-solver-verbosity=INTEGER
              The verbosity level of the linear solver (0: off, 2: all). Default: 0

       --matrix-add-well-contributions=BOOLEAN
              Explicitly specify the influences of  wells  between  cells  in  the  Jacobian  and
              preconditioner matrices. Default: false

       --max-inner-iter-ms-wells=INTEGER
              Maximum number of inner iterations for multi-segment wells. Default: 100

       --max-inner-iter-wells=INTEGER
              Maximum number of inner iterations for standard wells. Default: 50

       --max-newton-iterations-with-inner-well-iterations=INTEGER
              Maximum newton iterations with inner well iterations. Default: 8

       --max-pressure-change-ms-wells=SCALAR
              Maximum  relative  pressure change for a single iteration of the multi-segment well
              model. Default: 1e+06

       --max-residual-allowed=SCALAR
              Absolute maximum tolerated for  residuals  without  cutting  the  time  step  size.
              Default: 1e+07

       --max-single-precision-days=SCALAR
              Maximum time step size where single precision floating point arithmetic can be used
              solving for the linear systems of equations. Default: 20

       --max-temperature-change=SCALAR
              Maximum absolute change of temperature in a single iteration. Default: 5

       --max-welleq-iter=INTEGER
              Maximum number of iterations to determine solution the  well equations. Default: 30

       --maximum-number-of-well-switches=INTEGER
              Maximum number of times a well can switch to the same control. Default: 3

       --milu-variant=STRING
              Specify which variant of the modified-ILU preconditioner ought to be used. Possible
              variants  are:  ILU  (default,  plain  ILU), MILU_1 (lump diagonal with dropped row
              entries), MILU_2 (lump diagonal with the sum of the absolute values of the  dropped
              row   entries),  MILU_3  (if  diagonal is positive add sum of dropped row entrires.
              Otherwise subtract them), MILU_4 (if diagonal is positive add sum  of  dropped  row
              entrires. Otherwise do nothing. Default: "ILU"

       --min-strict-cnv-iter=INTEGER
              Minimum  number  of Newton iterations before relaxed tolerances can be used for the
              CNV convergence criterion. Default: 0

       --min-time-step-based-on-newton-iterations=SCALAR
              The minimum time step size (in days for field and metric unit  and  hours  for  lab
              unit) can be reduced to based on newton iteration counts. Default: 0

       --min-time-step-before-shutting-problematic-wells-in-days=SCALAR
              The  minimum  time  step  size  in  days  for which problematic wells are not shut.
              Default: 0.01

       --newton-max-iterations=INTEGER
              The maximum number of Newton iterations per time step. Default: 20

       --newton-max-relax=SCALAR
              The maximum relaxation factor of a Newton iteration. Default: 0.5

       --newton-min-iterations=INTEGER
              The minimum number of Newton iterations per time step. Default: 1

       --newton-relaxation-type=STRING
              The type of relaxation used by Newton method. Default: "dampen"

       --num-jacobi-blocks=INTEGER
              Number of blocks to be created for the Block-Jacobi preconditioner. Default: 0

       --opencl-ilu-reorder=STRING
              Choose the reordering strategy for ILU  for  openclSolver  and  fpgaSolver,  usage:
              '--opencl-ilu-reorder=[level_scheduling|graph_coloring],  level_scheduling  behaves
              like Dune and cusparse, graph_coloring is more aggressive and likely to be  faster,
              but  is random-based and generally increases the number of linear solves and linear
              iterations significantly. Default: ""

       --opencl-platform-id=INTEGER
              Choose platform ID for openclSolver, use 'clinfo' to determine valid platform  IDs.
              Default: 0

       --output-dir=STRING
              The directory to which result files are written. Default: ""

       --output-interval=INTEGER
              Specify  the number of report steps between two consecutive writes of restart data.
              Default: 1

       --output-mode=STRING
              Specify which messages are going to be printed. Valid values are:  none,  log,  all
              (default). Default: "all"

       --owner-cells-first=BOOLEAN
              Order cells owned by rank before ghost/overlap cells. Default: true

       --parameter-file=STRING
              An .ini file which contains a set of run-time parameters. Default: ""

       --pri-var-oscilation-threshold=SCALAR
              The threshold value for the primary variable switching conditions after its meaning
              has switched to hinder oscilations. Default: 1e-05

       --print-parameters=INTEGER
              Print the values of the  run-time  parameters  at  the  start  of  the  simulation.
              Default: 2

       --print-properties=INTEGER
              Print  the  values  of  the compile time properties at the start of the simulation.
              Default: 2

       --project-saturations=BOOLEAN
              Option for doing saturation projection. Default: false

       --regularization-factor-wells=SCALAR
              Regularization factor for wells. Default: 100

       --relaxed-max-pv-fraction=SCALAR
              The fraction of the pore volume of the reservoir where the volumetric  error  (CNV)
              may be voilated during strict Newton iterations. Default: 0.03

       --relaxed-pressure-tol-msw=SCALAR
              Relaxed tolerance for the MSW pressure solution. Default: 10000

       --relaxed-well-flow-tol=SCALAR
              Relaxed tolerance for the well flow residual. Default: 0.001

       --scale-linear-system=BOOLEAN
              Scale  linear  system  according  to  equation  scale  and  primary variable types.
              Default: false

       --sched-restart=BOOLEAN
              When restarting: should we try to  initialize  wells  and  groups  from  historical
              SCHEDULE section. Default: false

       --serial-partitioning=BOOLEAN
              Perform partitioning for parallel runs on a single process. Default: false

       --shut-unsolvable-wells=BOOLEAN
              Shut unsolvable wells. Default: true

       --solve-welleq-initially=BOOLEAN
              Fully  solve  the  well  equations  before  each  iteration of the reservoir model.
              Default: true

       --solver-continue-on-convergence-failure=BOOLEAN
              Continue instead of stop when minimum solver time step is reached. Default: false

       --solver-growth-factor=SCALAR
              The factor time steps are elongated after a successful substep. Default: 2

       --solver-max-growth=SCALAR
              The maximum factor time steps are elongated after a report step. Default: 3

       --solver-max-restarts=INTEGER
              The maximum number of breakdowns before a substep is given up and the simulator  is
              terminated. Default: 10

       --solver-max-time-step-in-days=SCALAR
              The maximum size of a time step in days. Default: 365

       --solver-min-time-step=SCALAR
              The  minimum size of a time step in days for field and metric and hours for lab. If
              a step cannot converge without getting cut below this step size the simulator  will
              stop. Default: 1e-12

       --solver-restart-factor=SCALAR
              The factor time steps are elongated after restarts. Default: 0.33

       --solver-verbosity=INTEGER
              Specify the "chattiness" of the non-linear solver itself. Default: 1

       --strict-inner-iter-wells=INTEGER
              Number of inner well iterations with strict tolerance. Default: 40

       --strict-outer-iter-wells=INTEGER
              Number  of  newton  iterations  for  which wells are checked with strict tolerance.
              Default: 6

       --temperature-max=SCALAR
              Maximum absolute temperature. Default: 1e+09

       --temperature-min=SCALAR
              Minimum absolute temperature. Default: 0

       --threads-per-process=INTEGER
              The  maximum  number  of  threads  to  be  instantiated  per  process  ('-1'  means
              'automatic'). Default: -1

       --time-step-after-event-in-days=SCALAR
              Time  step  size of the first time step after an event occurs during the simulation
              in days. Default: -1

       --time-step-control=STRING
              The  algorithm  used  to  determine  time-step  sizes.  valid  options  are:  'pid'
              (default),      'pid+iteration',      'pid+newtoniteration',      'iterationcount',
              'newtoniterationcount' and 'hardcoded'. Default: "pid+newtoniteration"

       --time-step-control-decay-damping-factor=SCALAR
              The decay rate of the time step decrease when the target  iterations  is  exceeded.
              Default: 1

       --time-step-control-decay-rate=SCALAR
              The  decay  rate  of  the  time  step  size  of  the number of target iterations is
              exceeded. Default: 0.75

       --time-step-control-file-name=STRING
              The name of the file which  contains  the  hardcoded  time  steps  sizes.  Default:
              "timesteps"

       --time-step-control-growth-damping-factor=SCALAR
              The  growth  rate of the time step increase when the target iterations is undercut.
              Default: 3.2

       --time-step-control-growth-rate=SCALAR
              The growth rate of the time step  size  of  the  number  of  target  iterations  is
              undercut. Default: 1.25

       --time-step-control-target-iterations=INTEGER
              The  number  of linear iterations which the time step control scheme should aim for
              (if applicable). Default: 30

       --time-step-control-target-newton-iterations=INTEGER
              The number of Newton iterations which the time step control scheme should  aim  for
              (if applicable). Default: 8

       --time-step-control-tolerance=SCALAR
              The tolerance used by the time step size control algorithm. Default: 0.1

       --time-step-verbosity=INTEGER
              Specify the "chattiness" during the time integration. Default: 1

       --tolerance-cnv=SCALAR
              Local convergence tolerance (Maximum of local saturation errors). Default: 0.01

       --tolerance-cnv-relaxed=SCALAR
              Relaxed   local  convergence  tolerance  that  applies  for  iterations  after  the
              iterations with the strict tolerance. Default: 1

       --tolerance-mb=SCALAR
              Tolerated mass balance error relative to total mass present. Default: 1e-06

       --tolerance-pressure-ms-wells=SCALAR
              Tolerance for the pressure equations for multi-segment wells. Default: 1000

       --tolerance-well-control=SCALAR
              Tolerance for the well control equations. Default: 1e-07

       --tolerance-wells=SCALAR
              Well convergence tolerance. Default: 0.0001

       --update-equations-scaling=BOOLEAN
              Update scaling factors for mass balance equations during the run. Default: false

       --use-gmres=BOOLEAN
              Use GMRES as the linear solver. Default: false

       --use-multisegment-well=BOOLEAN
              Use the well model for multi-segment wells instead of the  one  for  single-segment
              wells. Default: true

       --use-update-stabilization=BOOLEAN
              Try  to  detect  and  correct  oscillations or stagnation during the Newton method.
              Default: true

       --zoltan-imbalance-tol=SCALAR
              Tolerable imbalance  of  the  loadbalancing  provided  by  Zoltan  (default:  1.1).