Provided by: sg3-utils_1.46-1build1_amd64 bug

NAME

       sg_sat_read_gplog - use ATA READ LOG EXT command via a SCSI to ATA Translation (SAT) layer

SYNOPSIS

       sg_sat_read_gplog   [--ck_cond]  [--count=CO]  [--dma]  [--help]  [--hex]  [--len={16|12}]
       [--log=LA] [--page=PN] [--readonly] [--verbose] [--version] DEVICE

DESCRIPTION

       This utility sends an ATA READ LOG EXT or an ATA READ LOG DMA EXT command to  the  DEVICE.
       This  command  is  used to read the general purpose log of (S)ATA disks (not ATAPI devices
       such as DVD driver). Rather than send the READ LOG  (DMA)  EXT  command  directly  to  the
       device  it  is  sent  via  a  SCSI  transport  which  is  assumed to contain a SCSI to ATA
       Translation (SAT) Layer (SATL). The SATL may be in an operating system driver, in host bus
       adapter (HBA) firmware or in some external enclosure.

       This  utility  does not currently attempt to decode the response from the ATA disk, rather
       it outputs the response in ASCII hexadecimal  grouped  in  16  bit  words.  Following  ATA
       conventions  those  words  are  decoded  little  endian (note that SCSI commands use a big
       endian representation). In the future this utility may attempt to decode some  log  pages,
       perhaps using the --decode option.

       The  SAT-2  standard  (SAT  ANSI INCITS 465-2010, prior draft: sat2r09.pdf at www.t10.org)
       defines two SCSI "ATA PASS-THROUGH" commands: one using a 16 byte "cdb" and the other with
       a 12 byte cdb. This utility defaults to using the 16 byte cdb variant.

OPTIONS

       Arguments to long options are mandatory for short options as well.

       -C, --ck_cond
              sets the CK_COND bit in the ATA PASS-THROUGH SCSI cdb. The default setting is clear
              (i.e. 0). When set the SATL should yield a sense buffer  containing  a  ATA  Result
              descriptor  irrespective of whether the ATA command succeeded or failed. When clear
              the SATL should only yield a sense buffer containing a ATA Result descriptor if the
              ATA command failed.

       -c, --count=CO
              the  number CO is placed in the "count" field in the ATA READ LOG EXT command. This
              specified the number of 512-byte blocks of data to be read from the specified log.

       -d, --dma
              use the ATA READ LOG DMA EXT command instead of ATA READ  LOG  EXT  command.   Some
              devices require this to return valid log data.

       -h, --help
              outputs  the  usage  message  summarizing command line options then exits.  Ignores
              DEVICE if given.

       -H, --hex
              when given once, the response is output in  ASCII  hexadecimal  bytes.  When  given
              twice,  then  the response is grouped into 16 bit words using ATA conventions (i.e.
              little endian); this is the default output (i.e. when this option  is  not  given).
              When  given  thrice  (i.e.  '-HHH')  the  output is in hex, grouped in 16 bit words
              (without a leading offset and trailing ASCII on each line), in  a  format  that  is
              acceptable for 'hdparm --Istdin' to process.

       -L, --log=LA
              the  number  LA is known as the "log address" in the ATA standards and is placed in
              bits 7:0 of the "lba" field of the ATA READ LOG (DMA) EXT command.  This  specifies
              the  log  to  be  returned  (See  ATA-ACS  for  a  detailed  list  of available log
              addresses). The default value  placed  in  the  "lba  field  is  0,  returning  the
              directory of available logs. The maximum value allowed for LOG is 0xff.

       -p, --page=PN
              the  number  PN  is  the page number (within the log address) and is placed in bits
              32:16 of the "lba" field of the ATA READ LOG (DMA) EXT command. The  default  value
              placed in the "lba" field is 0. The maximum value allowed for LOG is 0xffff.

       -l, --len={16|12}
              this  is  the  length  of the SCSI cdb used for the ATA PASS-THROUGH commands.  The
              argument can either be 16 or 12. The default is 16.  Some  SCSI  transports  cannot
              convey SCSI commands longer than 12 bytes.

       -r, --readonly
              causes  the  DEVICE  to  be  opened with the read-only flag (O_RDONLY in Unix). The
              default action is to open DEVICE with the read-write flag (O_RDWR in Unix). In some
              cases  sending power management commands to ATA disks are defeated by OS actions on
              the close() if the DEVICE was opened with the read-write flag (e.g.  the  OS  might
              think it needs to flush something to disk).

       -v, --verbose
              increases the level or verbosity.

       -V, --version
              print out version string

NOTES

       Prior  to  Linux  kernel 2.6.29 USB mass storage limited sense data to 18 bytes which made
       the --ck_cond option yield strange (truncated) results.

EXIT STATUS

       The exit status of sg_sat_read_gplog is  0  when  it  is  successful.  Otherwise  see  the
       sg3_utils(8) man page.

AUTHOR

       Written by Hannes Reinecke and Douglas Gilbert

REPORTING BUGS

       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

       Copyright © 2014-2015 Hannes Reinecke, SUSE Linux GmbH
       This  software  is distributed under a FreeBSD license. There is NO warranty; not even for
       MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO