Provided by: openhpi-clients_3.8.0-2.1build5_amd64
NAME
hpialarms - A openhpi sample application that shows "Alarm Control" management instruments
SYNOPSIS
hpialarms [-D id] [-N host[:port]] [-C <cfgfile>] [-a 1|0][-b 1|0][-c 1|0][-m 1|0][-n 1|0][-p 1|0][-i n][-o][-X][-h] hpialarms [--domain=id] [--host=host[:port]] [--cfgfile=file] [--diska=1|0] [--diskb=1|0] [--critical=1|0] [--major=1|0] [--minor=1|0] [--power=1|0] [--chassisid=n] [--all] [--debug] [--help]
DESCRIPTION
hpialarms walks the RPT (Resource Presence Table) for resources that have "Alarm Control" management instruments (SAHPI_CTRL_LED). If no domain or host is selected, hpialarms uses the default domain as specified in the openhpiclient.conf file.
OPTIONS
(No Option) Display alarm states Help Options: -h, --help Show help options Application Options: -c 1|0, --critical=1|0 Set critical alarm on|off -m 1|0, --major=1|0 Set major alarm on|off -n 1|0, --minor=1|0 Set minor alarm on|off -a 1|0, --diska=1|0 Set diska alarm on|off -b 1|0, --diskb=1|0 Set diskb alarm on|off -p 1|0, --power=1|0 Set power alarm on|off -i n, --chassisid=n Set chassis id on for n seconds -o, --all Set all alarms off -D nn, --domain=nn Select domain id nn -X, --debug Display debug messages -N "host[:port]", --host="host[:port]" Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and OPENHPI_DAEMON_PORT environment variables. If host contains ':' (for example IPv6 address) then enclose it in square brackets. For example: "[::1]" or "[::1]:4743". -C "file", --cfgfile="file" Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONF environment variable.
SAMPLE OUTPUT
hpialarmpanel ver 0.6 RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid=1 tag: Mullins RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON RDR[46]: ctltype=0:0 oem=0 Cold Reset Control RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
SEE ALSO
hpi_shell hpidomain hpigensimdata hpireset hpitop hpiel hpiinv hpisensor hpitree hpievents hpionIBMblade hpisettime hpiwdt hpifan hpipower hpithres hpixml ohdomainlist ohhandler ohparam
AUTHORS
Authors of this man page: Peter D Phan (pdphan@users.sourceforge.net) Ulrich Kleber (ulikleber@users.sourceforge.net) Anton Pak (avpak@users.sourceforge.net)