Provided by: mia-tools_2.4.7-13_amd64
NAME
mia-2dmyocard-icaseries - Run an ICA analysis on a series of 2D images
SYNOPSIS
mia-2dmyocard-icaseries -i <in-file> [options]
DESCRIPTION
mia-2dmyocard-icaseries This program is used to run a ICA on a series of myocardial perfusion images given in a segmentation set in order to create sythetic references that can be used for motion correction by image registration. If the aim is to run a full motion compensation then it is better run mia-2dmyoica-nonrigid, since this program is essentially the same without the registration bits.
OPTIONS
File-IO -i --in-file=(required, input); string input perfusion data set -r --references=(output); string File name base for the reference images. Image type and numbering scheme are taken from the input images. -c --save-cropped=(output); string save cropped set of the original set to this file, the image files will use the stem of the name as file name base --save-feature=(output); string save the features images resulting from the ICA and some intermediate images used for the RV-LV segmentation with the given file name base to PNG files. Also save the coefficients of the initial best and the final IC mixing matrix. Help & Info -V --verbose=warning verbosity of output, print messages of given level and higher priorities. Supported priorities starting at lowest level are: trace ‐ Function call trace debug ‐ Debug output info ‐ Low level messages message ‐ Normal messages warning ‐ Warnings fail ‐ Report test failures error ‐ Report errors fatal ‐ Report only fatal errors --copyright print copyright information -h --help print this help -? --usage print a short help --version print the version number and exit ICA --fastica=internal FastICA implementationto be used For supported plugins see PLUGINS:fastica/implementation -C --components=0 ICA components 0 = automatic estimation --normalize normalized ICs --no-meanstrip don't strip the mean from the mixing curves -s --segscale=1.4 segment and scale the crop box around the LV (0=no segmentation) -k --skip=0 skip images at the beginning of the series as they are of other modalities -m --max-ica-iter=400 maximum number of iterations in ICA -E --segmethod=features Segmentation method delta-feature ‐ difference of the feature images delta-peak ‐ difference of the peak enhancement images features ‐ feature images Processing --threads=-1 Maxiumum number of threads to use for processing,This number should be lower or equal to the number of logical processor cores in the machine. (-1: automatic estimation).
PLUGINS: fastica/implementation
internal This is the MIA implementation of the FastICA algorithm. (no parameters) itpp This is the IT++ implementation of the FastICA algorithm. (no parameters)
EXAMPLE
Evaluate the synthetic references from set segment.set and save them to refXXXX.??? by using five independend components, and skipping 2 images. Per default a bounding box around the LV will be segmented and scaled by 1.4 and the cropped images will be saved to cropXXXX.??? and a segmentation set cropped.set is created. The image file type ??? is deducted from the input images in segment.set. mia-2dmyocard-icaseries -i segment.set -r ref -o ref -k 2 -C 5
AUTHOR(s)
Gert Wollny
COPYRIGHT
This software is Copyright (c) 1999‐2015 Leipzig, Germany and Madrid, Spain. It comes with ABSOLUTELY NO WARRANTY and you may redistribute it under the terms of the GNU GENERAL PUBLIC LICENSE Version 3 (or later). For more information run the program with the option '--copyright'.