Provided by: ndctl_76-1ubuntu1_amd64
NAME
ndctl-inject-smart - perform smart threshold/injection operations on a DIMM
SYNOPSIS
ndctl inject-smart <dimm> [<options>]
DESCRIPTION
A generic DIMM device object, named /dev/nmemX, is registered for each memory device indicated in the ACPI NFIT table, or other platform NVDIMM resource discovery mechanism. ndctl-inject-smart can be used to set smart thresholds, and inject smart attributes.
EXAMPLES
Set smart controller temperature and spares threshold for DIMM-0 to 32C, spares threshold to 8, and enable the spares alarm. ndctl inject-smart --ctrl-temperature-threshold=32 --spares-threshold=8 --spares-alarm nmem0 Inject a media temperature value of 52 and fatal health status flag for DIMM-0 ndctl inject-smart --media-temperature=52 --health=fatal nmem0
OPTIONS
-b, --bus= A bus id number, or a provider string (e.g. "ACPI.NFIT"). Restrict the operation to the specified bus(es). The keyword all can be specified to indicate the lack of any restriction, however this is the same as not supplying a --bus option at all. -m, --media-temperature= Inject <value> for the media temperature smart attribute. -M, --media-temperature-threshold= Set <value> for the smart media temperature threshold. --media-temperature-alarm= Enable or disable the smart media temperature alarm. Options are on or off. --media-temperature-uninject Uninject any media temperature previously injected. -c, --ctrl-temperature= Inject <value> for the controller temperature smart attribute. -C, --ctrl-temperature-threshold= Set <value> for the smart controller temperature threshold. --ctrl-temperature-alarm= Enable or disable the smart controller temperature alarm. Options are on or off. --ctrl-temperature-uninject Uninject any controller temperature previously injected. -s, --spares= Inject <value> for the spares smart attribute. -S, --spares-threshold= Set <value> for the smart spares threshold. --spares-alarm= Enable or disable the smart spares alarm. Options are on or off. --spares-uninject Uninject any spare percentage previously injected. -f, --fatal Set the flag to spoof fatal health status. --fatal-uninject Uninject the fatal health status flag. -U, --unsafe-shutdown Set the flag to spoof an unsafe shutdown on the next power down. --unsafe-shutdown-uninject Uninject the unsafe shutdown flag. -N, --uninject-all Uninject all possible smart fields/values irrespective of whether they have been previously injected or not. -v, --verbose Emit debug messages for the error injection process -u, --human Format numbers representing storage sizes, or offsets as human readable strings with units instead of the default machine-friendly raw-integer data. Convert other numeric fields into hexadecimal strings.
COPYRIGHT
Copyright © 2016 - 2022, Intel Corporation. License GPLv2: GNU GPL version 2 http://gnu.org/licenses/gpl.html. This is free software: you are free to change and redistribute it. There is NO WARRANTY, to the extent permitted by law.
SEE ALSO
ndctl-list(1),