Provided by: nvme-cli_2.5-1_amd64 bug

NAME

       nvme-list-ctrl - Send NVMe Identify List Controllers, return result and structure

SYNOPSIS

       nvme list-ctrl <device> [--cntid=<cntid> | -c <cntid>]
                               [--namespace-id=<nsid> | -n <nsid>] [-o <fmt> | --output-format=<fmt>]
       DESCRIPTION

       For the NVMe device given, sends an identify command for controller list
       and provides the result and returned structure. This uses either mode
       12h or 13h depending on the requested namespace identifier.

       The <device> parameter is mandatory and may be either the NVMe character
       device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
       The starting controller in the list always begins with 0 unless the
       `'--cntid'` option is given to override.

       On success, the controller array is printed for each index and controller
       identifier.

       OPTIONS

       -c <cntid>, --cntid=<cntid>
           Retrieve the identify list structure starting with the given controller id.

       -n <nsid>, --namespace-id=<nsid>
           If provided, will request the controllers attached to the specified namespace. If no
           namespace is given, or set to 0, the command requests the controller list for the
           entire subsystem, whether or not they are attached to namespace(s).

       -o <format>, --output-format=<format>
           Set the reporting format to normal or json. Only one output format can be used at a
           time.

EXAMPLES

       No examples yet.

NVME

       Part of the nvme-user suite