Provided by: libncarg-dev_6.6.2.dfsg.1-2_amd64 bug

NAME

       Vectors_params - This document briefly describes all Vectors internal parameters.

DESCRIPTION

       Parameter descriptions follow, in alphabetical order. Each description begins with a line
       giving the three-character mnemonic name of the parameter, the phrase for which the
       mnemonic stands, the intrinsic type of the parameter, and an indication of whether or not
       it is an array.

       ACM - Arrow Color Mode - Integer

              ACM controls how color is applied to filled vector arrows. It applies only when AST
              has the value 1. Its behavior also depends on the setting of the parameter CTV.
              Assuming that CTV is set to a non-zero value, implying that multi-colored vectors
              are desired, ACM has the following settings:

              Value   Effect
              -----   ------
              -2      Multi-colored fill; outline off
              -1      Fill off; multi-colored outline
              0       Multi-colored fill; mono-colored outline
              1       Mono-colored fill; multi-colored outline
              2       Multi-colored fill; multi-colored outline

              Mono-colored outlines use the current GKS polyline color index. Mono-colored fill
              uses the current GKS fill color index. When CTV is set to 0, both the fill and the
              outlines become mono-colored, and therefore only modes -2, -1, and 0 remain
              distinguishable. The default value is 0.

       AFO - Arrow Fill Over Arrow Lines - Integer
              If AFO is set to 1, the perimeter outline of a filled vector arrow is drawn first,
              underneath the fill. In this case, you must set the line thickness parameter (LWD)
              to a value greater than unity in order for the line to appear completely. The
              advantage of drawing the line underneath is that the full extent of the fill
              appears, resulting in a crisper, more sharply defined arrow; when the line is drawn
              on top of the fill using a different color index, the fill color may be partially
              or completely obscured, especially for small vector arrows. AFO has an effect only
              when the parameter AST is set to 1.  The default value of AFO is 1.

       AIR - Arrow Interior Reference Fraction  - Real
              AIR specifies the distance from the point of the arrowhead of a filled vector arrow
              drawn at the reference length to the point where the arrowhead joins with the line
              extending to the tail of the arrow. Its value represents a fraction of the
              reference length.  This distance is adjusted proportionally to the X component of
              the arrowhead size for vector arrows whose length differs from the reference
              length.  See VRL for an explanation of how the reference length is determined.  AIR
              has an effect only when AST is set to 1. AIR is allowed to vary between 0.0 and 1.0
              and its default value is 0.33.

       AMN - Arrow Head Minimum Size - Real
              Specifies a minimum length for the two lines representing the point of the vector
              arrow head, as a fraction of the viewport width. AMN has an effect only for line-
              drawn vector arrows (parameter AST set to 0). Normally the arrow head size is
              scaled proportionally to the length of the vector. This parameter allows you to
              ensure that the arrow head will remain recognizable even for very short vectors.
              Note that you can cause all the arrowheads in the plot to be drawn at the same size
              if you set AMN and AMX to the same value. If you set both AMN and AMX to 0.0 the
              arrowheads will not be drawn at all.  The default value is 0.005.

       AMX - Arrow Head Maximum Size - Real
              Specifies a maximum length for the two lines representing the point of the vector
              arrow head, as a fraction of the viewport width.  AMX has an effect only for line-
              drawn vector arrows (parameter AST set to 0). Normally the arrow head is scaled
              proportionally to the length of the vector. This parameter allows you to ensure
              that the arrow heads do not become excessively large for high magnitude vectors.
              Note that you can cause all the arrowheads in the plot to be drawn at the same size
              if you set AMN and AMX to the same value. If you set both AMN and AMX to 0.0 the
              arrowheads will not be drawn at all. The default value is 0.05.

       AST - Arrow Style - Integer

              If AST is set to 0, the vector arrows are drawn using lines only. When AST is set
              to 1, the vectors are plotted using variable width filled arrows, with an optional
              outline. If AST is set to 2, wind barb glyphs are used to represent the
              vectors.There are parameters for controlling the appearance of each style. These
              have an effect only for one value of AST.  However, certain parameters apply to all
              arrow styles. Here is a table of parameters that affect the appearance of vectors
              and how their behavior is affected by the setting of AST:

              Parameter   Line-Drawn Arrows   Filled Arrows   Wind Barbs
              ---------   -----------------   -------------   ----------
              ACM                             x
              AFO                             x
              AIR                             x
              AMN         x
              AMX         x
              AWF                             x
              AWR                             x
              AXF                             x
              AXR                             x
              AYF                             x
              AYR                             x
              CLR         x                   x               x
              CTV         x                   x               x
              LWD         x                   x               x
              NLV         x                   x               x
              PAI         x                   x               x
              TVL         x                   x               x
              WBA                                             x
              WBC                                             x
              WBD                                             x
              WBS                                             x
              WBT                                             x

              When filled arrows are used, colors associated with the threshold levels may be
              applied to either or both the fill or the outline of the arrow.  When fill is drawn
              over the outline (AFO set to 1), LWD should be set to a value greater than 1.0 in
              order for the outline to be fully visible.  The default value of AST is 0.

       AWF - Arrow Width Fractional Minimum - Real
              AWF specifies the width of a filled arrow drawn at the minimum length, as a
              fraction of the width of an arrow drawn at the reference length. If AWF has the
              value 0.0, then the ratio of the arrow width to the arrow length will be constant
              for all arrows in the plot.  If given the value 1.0, the width will itself be
              constant for all arrows in the plot, regardless of length. See VFR for a discussion
              of how the minimum length is determined. AWF has an effect only when AST is set to
              1.  AWF is allowed to vary between 0.0 and 1.0 and its default value is 0.0.

       AWR - Arrow Width Reference Fraction - Real
              AWR specifies the width of a filled vector arrow drawn at the reference length, as
              a fraction of the reference length.  See VRL for an explanation of how the
              reference length is determined.  AWR has an effect only when AST is set to 1. AWR
              is allowed to vary between 0.0 and 1.0 and its default value is 0.03.

       AXF - Arrow X-Coord Fractional Minimum - Real
              AXF specifies the X component of the head of a filled vector arrow drawn at the
              minimum length, as a fraction of the X component of the head of an arrow drawn at
              the reference length. The X component of the arrowhead is the distance from the
              point of the arrowhead to a point along the centerline of the arrow perpendicular
              the arrowhead´s rear tips. If AXF has the value 0.0, then the ratio of the X
              component of the arrowhead size to the arrow length will be constant for all
              vectors in the plot. If given the value 1.0, the arrowhead X component will itself
              be constant for all arrows in the plot, regardless of their length. See VRL for an
              explanation of how the reference length is determined.  AXF has an effect only when
              AST is set to 1. AXF is allowed to vary between 0.0 and 1.0 and its default value
              is 0.0.

       AXR - Arrow X-Coord Reference Fraction - Real
              AXR specifies the X component of the head of a filled vector arrow drawn at the
              reference length, as a fraction of reference length. The X component of the
              arrowhead is the distance from the point of the arrowhead to a point along the
              centerline of the arrow perpendicular the arrowhead´s rear tips.  See VRL for an
              explanation of how the reference length is determined.  AXR has an effect only when
              AST is set to 1. AXR is allowed to vary between 0.0 and 2.0 and its default value
              is 0.36.

       AYF - Arrow Y-Coord Fractional Minimum - Real
              The value of this parameter, when added to the minimum width value, specifies the Y
              component length of the arrowhead size for a filled arrow drawn at the minimum
              length, as a fraction of the length specified by AYF. If given the value 1.0, the
              arrowhead Y component will extend the same distance perpendicularly from the edge
              of all arrows in the plot, regardless of their length and width. This can be a
              useful resource to adjust to ensure that the points of even very short vector
              arrows remain visible. See VFR for a discussion of how the minimum length is
              determined.  AYF has an effect only when AST is set to 1. AYF is allowed to vary
              between 0.0 and 1.0 and its default value is 0.25.

       AYR - Arrow Y-Coord Reference Fraction - Real
              AYR specifies the perpendicular distance from one side of a filled vector
              arrowdrawn at the reference length to one of the back tips of the arrowhead. The
              value represents a fraction of the value of of the reference length and, when added
              to half the arrow width, determines the Y component of the arrowhead size.  See VRL
              for an explanation of how the reference length is determined.  AYR has an effect
              only when AST is set to 1.  AYR is allowed to vary between 0.0 and 1.0 and its
              default value is 0.12.

       CLR - Array of GKS Color Indices - Integer Array
              This parameter represents an array containing the GKS color index to use for
              coloring the vector when the scalar quantity is less than or equal to the threshold
              value with the same index in the TVL threshold value array. Depending on the
              settings of AST and ACM it may specify a set of fill color indexes, a set of line
              color indexes, or both. In order to access a particular element of the CLR array,
              you must first set the value of PAI, the parameter array index parameter, to the
              value of the array element´s index. All elements of the array are set to one
              initially. Note that the Vectors utility makes no calls to set the GKS color
              representation (GSCR), nor ever modifies the contents of the CLR array; therefore
              you are responsible for creating a suitably graduated color palette and assigning
              the color index values into the CLR array, prior to calling VVECTR. Typically,
              assuming the desired RGB values have been previously stored in a 2 dimensional 3 x
              n array called RGB, you loop through the calls that set up the color representation
              and color index as in the following example for a fourteen color palette:

                   DO 100 I=1,14,1
                       CALL GSCR (1,I,RGB(1,I),RGB(2,I),RGB(3,I))
                       CALL VVSETI(´PAI -- Parameter Array Index´, I)
                       CALL VVSETI(´CLR -- GKS Color Index´, I)
               100 CONTINUE

              See the descriptions of CTV, NLV, and TVL for details on configuring the vector
              coloring scheme.

       CPM - Compatibility Mode - Integer
              Controls the degree of compatibility between pre-Version 3.2 capabilities of the
              Vectors utility and later versions. You can independently control three behaviors
              using the nine settings provided:

              •      use of VELVCT and VELVEC input parameters

              •      use of variables initialized in the VELDAT block data statement

              •      use of the old mapping routines, FX, FY, MXF, and MYF.

              Note, however, that when using the Version 3.2 entry points VVINIT and VVECTR, only
              the third behavior option has any meaning.

              When CPM is set to 0, its default value, the Vectors utility´s behavior varies
              depending on whether you access it through one of the pre-Version 3.2 entry points
              (VELVCT, VELVEC, and EZVEC), or through the VVINIT/VVECTR interface. Otherwise,
              positive values result in invocation of the pre-Version 3.2 mapping routines (FX,
              FY, MXF, and MYF) for the conversion from data to user coordinates. Negative values
              cause VVMPXY or perhaps VVUMXY to be used instead. When using the pre-Version 3.2
              interface, odd values of CPM cause the data values in the VELDAT block data
              subroutine to override corresponding values initialized in the Version 3.2 VVDATA
              block data subroutine, or set by the user calling VVSETx routines. Values of CPM
              with absolute value greater than two cause some of the input arguments to VELVEC
              and VELVCT to be ignored. These include FLO, HI, NSET, ISPV, SPV and (for VELVCT
              only) LENGTH.

              Here is a table of the nine settings of CPM and their effect on the operation of
              the Vectors utility:

              Value   Use FX, FY, etc.          Use VELDAT data   Use input args
              -----   ----------------          ---------------   --------------
              -4      no                        no                no
              -3      no                        yes               no
              -2      no                        no                yes
              -1      no                        yes               yes
              0       old - yes; new - no (*)   yes               yes
              1       yes                       yes               yes
              2       yes                       no                yes
              3       yes                       yes               no
              4       yes                       no                no

              (*) Old means EZVEC, VELVEC, VELVCT entry point; new, VVINIT/VVECTR.  Only the
              first column applies to the VVINIT/VVECTR interface. See the velvct man page for
              more detailed emulation information.

       CTV - Color Threshold Value Control - Integer
              In conjunction with NLV, this parameter controls vector coloring and the setting of
              threshold values. The vectors may be colored based on on the vector magnitude or on
              the contents of a scalar array (VVINIT/VVECTR input argument, P). A table of
              supported options follows:

              Value          Action

              -2             Color vector arrows based on scalar array data values; the user is
                             responsible for setting up threshold level array, TVL

              -1             Color vector arrows based on vector magnitude; the user is
                             responsible for setting up values of threshold level array.

              0(default)     Color all vectors according to the current GKS polyline color index
                             value. Threshold level array, TVL and GKS color index array, CLR are
                             not used.

              1              Color vector arrows based on vector magnitude; VVINIT assigns values
                             to the first NLV elements of the threshold level array, TVL.

              2              Color vector arrows based on scalar array data values; VVINIT
                             assigns values to the first NLV elements of the threshold level
                             array, TVL.

              If you make CTV positive, you must initialize Vectors with a call to VVINIT after
              the modification.

       DMN - NDC Minimum Vector Size - Real, Read-Only
              This parameter is read-only and has a useful value only following a call to VVECTR
              (directly or through the compatibility version of VELVCT). You may retrieve it in
              order to determine the length in NDC space of the smallest vector actually drawn
              (in other words, the smallest vector within the boundary of the user coordinate
              space that is greater than or equal in magnitude to the value of the VLC
              parameter). It is initially set to a value of 0.0.

       DMX - NDC Maximum Vector Size - Real, Read-Only
              Unlike DMN this read-only parameter has a potentially useful value betweens calls
              to VVINIT and VVECTR. However, the value it reports may be different before and
              after the call to VVECTR. Before the VVECTR call it contains the length in NDC
              space that would be used to render the maximum size vector assuming the user-
              settable parameter, VRL is set to its default value of 0.0.  After the VVECTR call
              it contains the NDC length used to render the largest vector actually drawn (in
              other words, the largest vector within the boundary of the user coordinate space
              that is less than or equal in magnitude to the value of the VHC parameter). See the
              section on the VRL parameter for information on using the value of DMX after the
              VVINIT call in order to adjust proportionally the lengths of all the vectors in the
              plot.  It is initially set to a value of 0.0.

       DPF - Vector Label Decimal Point Control Flag - Integer
              If DPF is set to a non-zero value, and the optional vector magnitude labels are
              enabled, the magnitude values are scaled to fit in the range 1 to 999. The labels
              will contain 1 to 3 digits and no decimal point. Otherwise, the labels will consist
              of a number up to six characters long, including a decimal point. By default DPF is
              set to the value 1.

       LBC - Vector Label Color - Integer
              This parameter specifies the color to use for the optional vector magnitude labels,
              as follows:

              Value          Action

              < -1           Draw labels using the current GKS text color index

              -1 (default)   Draw labels using the same color as the corresponding vector arrow

              >=0            Draw labels using the LBC value as the GKS text color index

       LBL - Vector Label Flag - Integer
              If set non-zero, Vectors draws labels representing the vector magnitude next to
              each arrow in the field plot.  The vector labels are primarily intended as a
              debugging aid, since in order to avoid excessive overlap, you must typically set
              the label text size too small to be readable without magnification. For this
              reason, as well as for efficiency, unlike the other graphical text elements
              supported by the Vectors utility, the vector labels are rendered using low quality
              text.

       LBS - Vector Label Character Size - Real
              This parameter specifies the size of the characters used for the vector magnitude
              labels as a fraction of the viewport width. The default value is 0.007.

       LWD - Vector Linewidth - Real

              LWD controls the linewidth used to draw the lines that form vector arrows and wind
              barbs. When the arrows are filled (AST is set to 1) LWD controls the width of the
              arrow's outline. If the fill is drawn over the outline (AFO set to 1) then LWD must
              be set to a value greater than 1.0 in order for the outline to appear properly.
              When AST has the value 2, LWD controls the width of the line elements of wind
              barbs. When AST is set to 0, specifying line-drawn vector arrows, the linewidth
              applies equally to the body of the vector and the arrowhead. Overly thick lines may
              cause the arrow heads to appear smudged. This was part of the motivation for
              developing the option of filled vector arrows. Note that since linewidth in NCAR
              Graphics is always calculated relative to a unit linewidth that is dependent on the
              output device, you may need to adjust the linewidth value depending on the intended
              output device to obtain a pleasing plot. The default is 1.0, specifying a device-
              dependent minimum linewidth.

       MAP - Map Transformation Code - Integer
              MAP defines the transformation between the data and user coordinate space.  Three
              MAP parameter codes are reserved for pre-defined transformations, as follows:

              Value          Mapping transformation

              0 (default)    Identity transformation between data and user coordinates: array
                             indices of U, V, and P are linearly related to data coordinates.

              1              Ezmap transformation: first dimension indices of U, V, and P are
                             linearly related to longitude; second dimension indices are linearly
                             related to latitude.

              2              Polar to rectangular transformation: first dimension indices of U,
                             V, and P are linearly related to the radius; second dimension
                             indices are linearly related to the angle in degrees.

              If MAP has any other value, Vectors invokes the user-modifiable subroutine, VVUMXY,
              to perform the mapping.  The default version of VVUMXY simply performs an identity
              transformation. Note that, while the Vectors utility does not actually prohibit the
              practice, the user is advised not to use negative integers for user-defined
              mappings, since other utilities in the NCAR Graphics toolkit attach a special
              meaning to negative mapping codes.

              For all the predefined mappings, the linear relationship between the grid array
              indices and the data coordinate system is established using the four parameters,
              XC1, XCM, YC1, and YCN. The X parameters define a mapping for the first and last
              indices of the first dimension of the data arrays, and the Y parameters do the same
              for the second dimension. If MAP is set to a value of one, be careful to ensure
              that the SET parameter is given a value of zero, since the Ezmap routines require a
              specific user coordinate space for each projection type, and internally call the
              SET routine to define the user to NDC mapping.  Otherwise, you may choose whether
              or not to issue a SET call prior to calling VVINIT, modifying the value of SET as
              required.  See the description of the parameter, TRT, and the vvumxy man page for
              more information.

       MNC - Minimum Vector Text Block Color - Integer
              MNC specifies the color of the minimum vector graphical text output block as
              follows:

              Value          Action

              <-2            Both the vector arrow and the text are colored using the current
                             text color index.

              -2             If the vectors are colored by magnitude, both the vector arrow and
                             the text use the GKS color index associated with the minimum vector
                             magnitude. Otherwise, the vector arrow uses the current polyline
                             color index and the text uses the current text color index.

              -1 (default)   If the vectors are colored by magnitude, the vector arrow uses the
                             GKS color index associated with the minimum vector magnitude.
                             Otherwise the vector arrow uses the current polyline color index.
                             The text is colored using the current text color index in either
                             case.

              >= 0           The value of MNC is used as the color index for both the text and
                             the vector arrow

              See the description of MNT for more information about the minimum vector text
              block.

       MNP - Minimum Vector Text Block Positioning Mode - Integer
              This parameter allows you to justify the minimum vector text block, taken as a
              single unit, relative to the text block position established by the parameters, MNX
              and MNY. Nine positioning modes are available, as follows:

              Mode           Justification

              -4             The lower left corner of the text block is positioned at MNX, MNY.

              -3             The center of the bottom edge is positioned at MNX, MNY.

              -2             The lower right corner is positioned at MNX, MNY.

              -1             The center of the left edge is positioned at MNX, MNY.

              0              The text block is centered along both axes at MNX, MNY.

              1              The center of the right edge is positioned at MNX, MNY.

              2              The top left corner is positioned at MNX, MNY.

              3              The center of the top edge is positioned at MNX, MNY.

              4 (default)    The top right corner is positioned at MNX, MNY.

              See the description of MNT for more information about the minimum vector text
              block.

       MNS - Minimum Vector Text Block Character Size - Real
              MNS specifies the size of the characters used in the minimum vector graphics text
              block as a fraction of the viewport width. See the description of MNT for more
              information about the minimum vector text block. The default value of MNS is
              0.0075.

       MNT - Minimum Vector Text String - Character* 36
              The minimum vector graphics text block consists of a user-definable text string
              centered underneath a horizontal arrow. If the parameter VLC is set negative the
              arrow is rendered at the size of the reference minimum magnitude vector (which may
              be smaller than any vector that actually appears in the plot). Otherwise, the arrow
              is the size of the smallest vector in the plot. Directly above the arrow is a
              numeric string in exponential format that represents the vector's magnitude.

              Use MNT to modify the text appearing below the vector in the minimum vector
              graphics text block. Currently the string length is limited to 36 characters. Set
              MNT to a single space (´ ´) to remove the text block, including the vector arrow
              and the numeric magnitude string, from the plot. The default value is ´Minimum
              Vector´

       MNX - Minimum Vector Text Block X Coordinate - Real
              MNX establishes the X coordinate of the minimum vector graphics text block as a
              fraction of the viewport width.  Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions to the left or right of the
              viewport. The actual position of the block relative to MNX depends on the value
              assigned to MNP. See the descriptions of MNT and MNP for more information about the
              minimum vector text block. The default value of MNX is 0.475.

       MNY - Minimum Vector Text Block Y Coordinate - Real
              MNY establishes the Y coordinate of the minimum vector graphics text block as a
              fraction of the viewport height.  Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions below or above the viewport. The
              actual position of the block relative to MNY depends on the value assigned to MNP.
              See the descriptions of MNT and MNP for more information about the minimum vector
              text block. The default value of MNY is -0.01.

       MSK - Mask To Area Map Flag - Integer
              Use this parameter to control masking of vectors to an existing area map created by
              routines in the Areas utility.  When MSK is greater than 0, masking is enabled and
              an the area map must be set up prior to the call to VVECTR. The area map array and,
              in addition, the name of a user-definable masked drawing routine, must be passed as
              input parameters to VVECTR. Various values of the MSK parameter have the following
              effects:

              Value          Effect

              <= 0 (default) No masking of vectors.

              1              The subroutine ARDRLN is called internally to decompose the vectors
                             into segments contained entirely within a single area.  ARDRLN calls
                             the user-definable masked drawing subroutine.

              >1             Low precision masking. ARGTAI is called internally to get the area
                             identifiers for the vector base position point. Then the user-
                             definable masked drawing subroutine is called to draw the vector.
                             Vectors with nearby base points may encroach into the intended mask
                             area.

              See the man page vvudmv for further explanation of masked drawing of vectors

       MXC - Maximum Vector Text Block Color - Integer
              MXC specifies the color of the maximum vector graphical text output block as
              follows:

              Value          Action

              <-2            Both the vector arrow and the text are colored using the current
                             text color index.

              -2             If the vectors are colored by magnitude, both the vector arrow and
                             the text use the GKS color index associated with the minimum vector
                             magnitude. Otherwise, the vector arrow uses the current polyline
                             color index and the text uses the current text color index.

              -1 (default)   If the vectors are colored by magnitude, the vector arrow uses the
                             GKS color index associated with the minimum vector magnitude.
                             Otherwise the vector arrow uses the current polyline color index.
                             The text is colored using the current text color index in either
                             case.

              >= 0           The value of MXC is used as the color index for both the text and
                             the vector arrow

              See the description of MXT for more information about the maximum vector text
              block.

       MXP - Maximum Vector Text Block Positioning Mode - Integer
              This parameter allows you to justify the maximum vector text block, taken as a
              single unit, relative to the text block position established by the parameters, MXX
              and MXY. Nine positioning modes are available, as follows:

              Mode           Justification

              -4             The lower left corner of the text block is positioned at MXX, MXY.

              -3             The center of the bottom edge is positioned at MXX, MXY.

              -2             The lower right corner is positioned at MXX, MXY.

              -1             The center of the left edge is positioned at MXX, MXY.

              0              The text block is centered along both axes at MXX, MXY.

              1              The center of the right edge is positioned at MXX, MXY.

              2              The top left corner is positioned at MXX, MXY.

              3              The center of the top edge is positioned at MXX, MXY.

              4              The top right corner is positioned at MXX, MXY.

              See the description of MXT for more information about the maximum vector text
              block.

       MXS - Maximum Vector Text Block Character Size - Real
              MXS specifies the size of the characters used in the maximum vector graphics text
              block as a fraction of the viewport width. See the description of MXT for more
              information about the maximum vector text block. The default value is 0.0075.

       MXT - Maximum Vector Text String - Character* 36
              The maximum vector graphics text block consists of a user-definable text string
              centered underneath a horizontal arrow. If the parameter VHC is set negative the
              arrow is rendered at the size of the reference maximum magnitude vector (which may
              be larger than any vector that actually appears in the plot). Otherwise, the arrow
              is the size of the largest vector in the plot. Directly above the arrow is a
              numeric string in exponential format that represents the magnitude of this vector.

              Use MXT to modify the text appearing below the vector in the maximum vector
              graphics text block. Currently the string length is limited to 36 characters. Set
              MXT to a single space (´ ´) to completely remove the text block, including the
              vector arrow and the numeric magnitude string, from the plot. Note that the name
              "Maximum Vector Text Block" is no longer accurate, since using the parameter VRM it
              is now possible to establish a reference magnitude that is smaller than the maximum
              magnitude in the data set. A more accurate name would be "Reference Vector Text
              Block".  The default value of MXT is ´Maximum Vector´.

       MXX - Maximum Vector Text Block X Coordinate - Real
              MXX establishes the X coordinate of the maximum vector graphics text block as a
              fraction of the viewport width.  Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions below or above of the viewport. The
              actual position of the block relative to MXX depends on the value assigned to MXP.
              See the descriptions of MXT and MXP for more information about the maximum vector
              text block. The default value is 0.525.

       MXY - Maximum Vector Text Block Y Coordinate - Real
              MXY establishes the Y coordinate of the maximum vector graphics text block as a
              fraction of the viewport width.  Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions below or above the viewport. The
              actual position of the block relative to MXY depends on the value assigned to MXP.
              See the descriptions of MXT and MXP for more information about the maximum vector
              text block.  The default value is -0.01.

       NLV - Number of Colors Levels - Integer
              NLV specifies the number of color levels to use when coloring the vectors according
              to data in a scalar array or by vector magnitude.  Anytime CTV has a non-zero
              value, you must set up the first NLV elements of the color index array CLR. Give
              each element the value of a GKS color index that must be defined by a call to the
              the GKS subroutine, GSCR, prior to calling VVECTR. If CTV is less than 0, in
              addition to setting up the CLR array, you are also responsible for setting the
              first NLV elements of the threshold values array, TVL to appropriate values. NLV is
              constrained to a maximum value of 255. The default value of NLV is 0, specifying
              that vectors are colored according to the value of the GKS polyline color index
              currently in effect, regardless of the value of CTV.  If CTV is greater than 0, you
              must initialize Vectors with a call to VVINIT after modifying this parameter.

       PAI - Parameter Array Index - Integer
              The value of PAI must be set before calling VVGETC, VVGETI, VVGETR, VVSETC, VVSETI,
              or VVSETR to access any parameter which is an array; it acts as a subscript to
              identify the intended array element. For example, to set the 10th color threshold
              array element to 7, use code like this:

               CALL VVSETI (´PAI - PARAMETER ARRAY INDEX´,10)
               CALL VVSETI (´CLR - Color Index´,7)

              The default value of PAI is one.

       PLR - Polar Input Mode - Integer
              When PLR is greater than zero, the vector component arrays are considered to
              contain the field data in polar coordinate form: the U array is treated as
              containing the vector magnitude and the V array as containing the vector angle. Be
              careful not to confuse the PLR parameter with the MAP parameter set to polar
              coordinate mode (2). The MAP parameter relates to the location of the vector, not
              its value. Here is a table of values for PLR:

              Value          Meaning

              0 (default)    U and V arrays contain data in cartesian component form.

              1              U array contains vector magnitudes; V array contains vector angles
                             in degrees.

              2              U array contain vector magnitudes; V array contains vector angles in
                             radians.

              You must initialize Vectors with a call to VVINIT after modifying this parameter.

       PMN - Minimum Scalar Array Value - Real, Read-Only
              You may retrieve the value specified by PMN at any time after a call to VVINIT. It
              will contain a copy of the minimum value encountered in the scalar data array. If
              no scalar data array has been passed into VVINIT it will have a value of 0.0.

       PMX - Maximum Scalar Array Value - Real
              You may retrieve the value specified by PMX at any time after a call to VVINIT. It
              contains a copy of the maximum value encountered in the scalar data array.  If no
              scalar data array has been passed into VVINIT it will have a value of 0.0.

       PSV - P Array Special Value - Real
              Use PSV to indicate the special value that flags an unknown data value in the P
              scalar data array. This value will not be considered in the determination of the
              data set maximum and minimum values. Also, depending on the setting of the SPC
              parameter, the vector may be specially colored to flag the unknown data point, or
              even eliminated from the plot. You must initialize Vectors with a call to VVINIT
              after modifying this parameter.

       SET - SET Call Flag - Integer
              Give SET the value 0 to inhibit the SET call VVINIT performs by default. Arguments
              5-8 of a SET call made by the user must be consistent with the ranges of the user
              coordinates expected by Vectors. This is determined by the mapping from grid to
              data coordinates as specified by the values of the parameters XC1, XCM, YC1, YCN,
              and also by the mapping from data to user coordinates established by the MAP
              parameter. You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of SET is 1.

       SPC - Special Color - Integer
              SPC controls special value processing for the optional scalar data array used to
              color the vectors, as follows:

              Value          Effect

              < 0 (default)  The P scalar data array is not examined for special values.

              0              Vectors at P scalar array special value locations are not drawn.

              > 0            Vectors at P scalar array special value locations are drawn using
                             color index SPC.

              You must initialize Vectors with a call to VVINIT after modifying this parameter.

       SVF - Special Value Flag - Integer
              The special value flag controls special value processing for the U and V vector
              component data arrays. Special values may appear in either the U or V array or in
              both of them. Five different options are available (although the usefulness of some
              of the choices is debatable):

              Value          Effect

              0 (default)    Neither the U nor the V array is examined for special values

              1              Vectors with special values in the U array are not drawn

              2              Vectors with special values in the V array are not drawn

              3              Vectors with special values in either the U or V array are not drawn

              4              Vectors with special values in both the U and V arrays are not drawn

              The U and V special values are defined by setting parameters USV and VSV. You must
              initialize Vectors with a call to VVINIT after modifying this parameter.

       TRT - Transformation Type - Integer
              As currently implemented, TRT further qualifies the mapping transformation
              specified by the MAP parameter, as follows:

              Value          Effect

              -1             Direction, magnitude, and location are all transformed. This option
                             is not currently supported by any of the pre-defined coordinate
                             system mappings.

              0              Only location is transformed

              1 (default)    Direction and location are transformed

              This parameter allows you to distinguish between a system that provides a mapping
              of location only into an essentially cartesian space, and one in which the space
              itself mapped. To understand the difference, using polar coordinates as an example,
              imagine a set of wind speed monitoring units located on a radial grid around some
              central point such as an airport control tower. Each unit´s position is defined in
              terms of its distance from the tower and its angular direction from due east.
              However, the data collected by each monitoring unit is represented as conventional
              eastward and northward wind components.  Assuming the towers´s location is at a
              moderate latitude, and the monitoring units are reasonably ´local´, this is an
              example of mapping a radially defined location into a nearly cartesian space (i.e.
              the eastward components taken alone all point in a single direction on the plot,
              outlining a series of parallel straight lines). One would set MAP to two (for the
              polar transformation) and TRT to zero to model this data on a plot generated by the
              Vectors utility.

              On the other hand, picture a set of wind data, again given as eastward and
              northward wind components, but this time the center of the polar map is actually
              the south pole. In this case, the eastward components do not point in a single
              direction; instead they outline a series of circles around the pole. This is a
              space mapping transformation: one would again set MAP to two, but TRT would be set
              to one to transform both direction and location.

              Changing the setting of this parameter affects the end results only when a non-
              uniform non-linear mapping occurs at some point in the transformation pipeline. For
              this discussion a uniform linear transformation is defined as one which satisfies
              the following equations:

               x_out = x_offset + scale_constant * x_in
               y_out = y_offset + scale_constant * y_in

              If scale_constant is not the same for both the X axis and the Y axis then the
              mapping is non-uniform.

              This option is currently implemented only for the pre-defined MAP parameter codes,
              0 and 2, the identity mapping and the polar coordinate mapping. However, it
              operates on a different stage of the transformation pipeline in each case. The
              polar mapping is non-linear from data to user coordinates. The identity mapping,
              even though necessarily linear over the data to user space mapping, can have a non-
              uniform mapping from user to NDC space, depending on the values given to the input
              parameters of the SET call. This will be the case whenever the LL input parameter
              is other than one, or when LL equals one, but the viewport and the user coordinate
              boundaries do not have the same aspect ratio. Thus for a MAP value of 2, TRT
              affects the mapping between data and user space, whereas for MAP set to 0, TRT
              influences the mapping between user and NDC space.

       TVL - Array of Threshold Values - Real Array
              TVL is an array of threshold values that is used to determine the individual vector
              color, when CTV and NLV are both non-zero. For each vector the TVL array is
              searched for the smallest value greater than or equal to the scalar value
              associated with the vector. The array subscript of this element is used as an index
              into the CLR array.  Vectors uses the GKS color index found at this element of the
              CLR array to set the color for the vector. Note that Vectors assumes that the
              threshold values are monotonically increasing.

              When CTV is less than 0, you are responsible for assigning values to the elements
              of TVL yourself. To do this, first set the PAI parameter to the index of the
              threshold level element you want to define, then call VVSETR to set TVL to the
              appropriate threshold value for this element. Assuming the desired values have
              previously been stored in a array named TVALS, you could assign the threshold
              values for a fourteen level color palette using the following loop:

                   DO 100 I=1,14,1
                       CALL VVSETI(PAI -- Parameter Array Index, I)
                       CALL VVSETR(TVL -- Threshold Value, TVALS(I))
               100 CONTINUE

              When CTV is greater than 0, Vectors assigns values into TVL itself. Each succeeding
              element value is greater than the preceding value by the value of the expression:

               (maximum_data_value - minimum_data_value) / NLV

              where the data values are either from the scalar data array or are the magnitudes
              of the vectors in the vector component arrays. The first value is equal to the
              minimum value plus the expression; the final value (indexed by the value of NLV) is
              equal to the maximum value. If Vectors encounters a value greater than the maximum
              value in the TVL array while processing the field data, it gives the affected
              vector the color associated with the maximum TVL value.

       USV - U Array Special Value - Real
              USV is the U vector component array special value. It is a value outside the range
              of the normal data used to indicate that there is no valid data for this grid
              location. When SVF is set to 1 or 3, Vectors will not draw a vector whose U
              component has the special value. You must initialize Vectors with a call to VVINIT
              after modifying this parameter. It has a default value of 1.0 E12.

       VFR - Minimum Vector Fractional Length - Real
              Use this parameter to adjust the realized size of the reference minimum magnitude
              vector relative to the reference maximum magnitude vector in order to improve the
              appearance or perhaps the information content of the plot. Specify VFR as a value
              between 0.0 and 1.0, where 0.0 represents an unmodified linear scaling of the
              realized vector length, in proportion to magnitude, and 1.0 specifies that the
              smallest vector be represented at 1.0 times the length of the largest vector,
              resulting in all vectors, regardless of magnitude, having the same length on the
              plot. A value of 0.5 means that the smallest magnitude vector appears half as long
              as the largest magnitude vector; intermediate sizes are proportionally scaled to
              lengths between these extremes. Where there is a wide variation in magnitude within
              the vector field, you can use this parameter to increase the size of the smallest
              vectors to a usefully visible level. Where the variation is small, you can use the
              parameter to exaggerate the differences that do exist. See also the descriptions of
              VRL, VLC, VHC, and VRM. The default value is 0.0.

       VHC - Vector High Cutoff Value - Real
              If the parameter VRM is set to a value greater than 0.0, it supercedes the use of
              VHC to specify the reference magnitude. VRM allows greater flexibility in that it
              can be used to specify an arbitrary reference magnitude that need not be the
              maximum magnitude contained in the data set. VHC can still be used to set a high
              cutoff value -- no vectors with magnitude greater than the cutoff value will be
              displayed in the plot.

              If VRM has its default value, 0.0, VHC specifies the reference maximum magnitude
              represented by an arrow of length VRL (as a fraction of the viewport width). The
              realized length of each individual vector in the plot is based on its magnitude
              relative to the reference maximum magnitude and, if VFR is non-zero, the reference
              minimum magnitude (as specified by VLC). Note that the reference maximum magnitude
              may be greater than the magnitude of any vector in the dataset. The effect of this
              parameter varies depending on its value, as follows:

              Value          Effect

              < 0.0          The absolute value of VHC unconditionally determines the reference
                             maximum magnitude. Vectors in the dataset with magnitude greater
                             than VHC are not displayed.

              0.0 (default)  The vector with the greatest magnitude in the dataset determines the
                             reference maximum magnitude.

              > 0.0          The minimum of VHC and the vector with the greatest magnitude in the
                             data set determines the reference maximum magnitude. Vectors in the
                             dataset with magnitude greater than VHC are not displayed.

              Typically, for direct comparison of the output of a series of plots, you would set
              VHC to a negative number, the absolute value of which is greater than any expected
              vector magnitude in the series. You can turn on Vectors statistics reporting using
              the parameter VST in order to see if any vectors in the datasets do exceed the
              maximum magnitude you have specified. See also the descriptions of the parameters
              VRM, VRL, DMX, VLC, and VFR.

       VLC - Vector Low Cutoff Value - Real
              Use this parameter to prevent vectors smaller than the specified magnitude from
              appearing in the output plot. VLC also specifies the reference minimum magnitude
              that is rendered at the size specified by the product of VRL and VFR (as a fraction
              of the viewport width), when VFR is greater than 0.0. Note that the reference
              minimum magnitude may be smaller than the magnitude of any vector in the dataset.
              The effect of this parameter varies depending on its value, as follows:

              Value          Effect

              < 0.0          The absolute value of VLC unconditionally determines the reference
                             minimum magnitude. Vectors in the dataset with magnitude less than
                             VLC do not appear.

              0.0 (default)  The vector with the minimum magnitude in the dataset determines the
                             reference minimum magnitude.

              > 0.0          The maximum of VLC and the vector with the least magnitude in the
                             data set determines the reference minimum magnitude. Vectors in the
                             dataset with magnitude less than VLC do not appear.

              The initialization subroutine, VVINIT, calculates the magnitude of all the vectors
              in the vector field, and stores the maximum and minimum values. You may access
              these values by retrieving the read-only parameters, VMX and VMN.  Thus it is
              possible to remove the small vectors without prior knowledge of the data domain.
              The following code fragment illustrates how the smallest 10% of the vectors could
              be removed:

               CALL VVINIT(...
               CALL VVGETR(´VMX - Vector Maximum Magnitude´, VMX)
               CALL VVGETR(´VMN - Vector Minimum Magnitude´, VMN)
               CALL VVSETR(´VLC - Vector Low Cutoff Value´,
              +     VMN+0.1*(VMX-VMN))
               CALL VVECTR(...

              On the other hand, when creating a series of plots that you would like to compare
              directly and you are using VFR to set a minimum realized size for the vectors, you
              can ensure that all vectors of a particular length represent the same magnitude on
              all the plots by setting both VHC and VLC to negative values. If you do not
              actually want to remove any vectors from the plot, make VLC smaller in absolute
              value than any expected magnitude. You can turn on Vectors statistics reporting
              using the parameter VST in order to see if any vectors in the datasets are less the
              minimum magnitude you have specified. See also the descriptions of parameters VFR,
              VRL, VHC, DMN, and VRM.

       VMD - Vector Minimum Distance - Real
              If VMD is set to a value greater than 0.0, it specifies, as a fraction of the
              viewport width, a minimum distance between adjacent vectors arrows in the plot. The
              distribution of vectors is analyzed and then vectors are selectively removed in
              order to ensure that the remaining vectors are separated by at least the specified
              distance. The thinning algorithm requires that you supply Vectors with a work array
              twice the size of the VVINIT arguments N and M multiplied together. Use of this
              capability adds some processing time to the execution of Vectors. If VMD is set to
              a value greater than 0.0 and no work array is provided, an error condition results.

              If the data grid is transformed in such a way that adjacent grid cells become very
              close in NDC space, as for instance in many map projections near the poles, you can
              use this parameter to reduce the otherwise cluttered appearance of these regions of
              the plot. The default value of VMD is 0.0.

       VMN - Minimum Vector Magnitude - Real, Read-Only
              After a call to VVINIT, VMN contains the value of the minimum vector magnitude in
              the U and V vector component arrays. Later, after VVECTR is called, it is modified
              to contain the magnitude of the smallest vector actually displayed in the plot.
              This is the vector with the smallest magnitude greater than or equal to the value
              specified by VLC, the vector low cutoff parameter, (0.0 if VLC has its default
              value) that falls within the user coordinate window boundaries. The value contained
              in VMN is the same as that reported as the 'Minimum plotted vector magnitude' when
              Vectors statistics reporting is enabled. It may be larger than the reference
              minimum magnitude reported by the minimum vector text block if you specify the VLC
              parameter as a negative value. VMN is initially set to a value of 0.0.

       VMX - Maximum Vector Magnitude - Real, Read-Only
              After a call to VVINIT, VMX contains the value of the maximum vector magnitude in
              the U and V vector component arrays. Later, after VVECTR is called, it is modified
              to contain the magnitude of the largest vector actually displayed in the plot. This
              is the vector with the largest magnitude less than or equal to the value specified
              by VHC, the vector high cutoff parameter, (the largest floating point value
              available on the machine if VHC has its default value, 0.0) that falls within the
              user coordinate window boundaries. The value contained in VMX is the same as that
              reported as the 'Maximum plotted vector magnitude' when Vectors statistics
              reporting is enabled. It may be smaller than the reference maximum magnitude
              reported by the maximum vector text block if you specify the VHC parameter as a
              negative value. VMX is initially set to a value of 0.0.

       VPB - Viewport Bottom - Real
              The parameter VPB has an effect only when SET is non-zero, specifying that Vectors
              should do the call to SET. It specifies a minimum boundary value for the bottom
              edge of the viewport in NDC space, and is constrained to a value between 0.0 and
              1.0. It must be less than the value of the Viewport Top parameter, VPT. The actual
              value of the viewport bottom edge used in the plot may be greater than the value of
              VPB, depending on the setting of the Viewport Shape parameter, VPS.  You must
              initialize Vectors with a call to VVINIT after modifying this parameter. The
              default value of VPB is 0.05.

       VPL - Viewport Left - Real
              The parameter VPL has an effect only when SET is non-zero, specifying that Vectors
              should do the call to SET. It specifies a minimum boundary value for the left edge
              of the viewport in NDC space, and is constrained to a value between 0.0 and 1.0. It
              must be less than the value of the Viewport Right parameter, VPR. The actual value
              of the viewport left edge used in the plot may be greater than the value of VPL,
              depending on the setting of the Viewport Shape parameter, VPS.  You must initialize
              Vectors with a call to VVINIT after modifying this parameter. The default value of
              VPL is 0.05.

       VPO - Vector Positioning Mode - Integer
              VPO specifies the position of the vector arrow in relation to the grid point
              location of the vector component data.  Three settings are available, as follows:

              Value          Effect

              <0             The head of the vector arrow is placed at the grid point location

              0 (default)    The center of the vector arrow is placed at the grid point location

              >0             The tail of the vector arrow is placed at the grid point location

       VPR - Viewport Right - Real
              The parameter VPR has an effect only when SET is non-zero, specifying that Vectors
              should do the call to SET. It specifies a maximum boundary value for the right edge
              of the viewport in NDC space, and is constrained to a value between 0.0 and 1.0. It
              must be greater than the value of the Viewport Left parameter, VPL. The actual
              value of the viewport right edge used in the plot may be less than the value of
              VPR, depending on the setting of the Viewport Shape parameter, VPS.  You must
              initialize Vectors with a call to VVINIT after modifying this parameter. The
              default value of VPR is 0.95.

       VPS - Viewport Shape - Real
              The parameter VPS has an effect only when SET is non-zero, specifying that Vectors
              should do the call to SET; it specifies the desired viewport shape, as follows:

              Value          Effect

              <0.0           The absolute value of VPS specifies the shape to use for the
                             viewport., as the ratio of the viewport width to its height,

              0.0            The viewport completely fills the area defined by the boundaries
                             specifiers, VPL, VPR, VPB, VPT

              >0.0,<1.0 (0.25, default)
                             Use R = (XCM-XC1)/(YCN-YC1) as the viewport shape if MIN(R, 1.0/R)
                             is greater than VPS. Otherwise determine the shape as when VPS is
                             equal to 0.0.

              >= 1.0         Use R = (XCM-XC1)/(YCN-YC1) as the viewport shape if MAX(R, 1.0/R)
                             is less than VPS. Otherwise make the viewport a square.

              The viewport, whatever its final shape, is centered in, and made as large as
              possible in, the area specified by the parameters VPB, VPL, VPR, and VPT. You must
              initialize Vectors with a call to VVINIT after modifying this parameter. The
              default value of VPS is 25.

       VPT - Viewport Top - Real
              The parameter VPT has an effect only when SET is non-zero, specifying that Vectors
              should do the call to SET. It specifies a maximum boundary value for the top edge
              of the viewport in NDC space, and is constrained to a value between 0.0 and 1.0. It
              must be greater than the value of the Viewport Bottom parameter, VPB. The actual
              value of the viewport top edge used in the plot may be less than the value of VPT,
              depending on the setting of the Viewport Shape parameter, VPS.  You must initialize
              Vectors with a call to VVINIT after modifying this parameter. The default value of
              VPT is 0.95.

       VRL - Vector Reference Length - Real
              Use this parameter to specify the realized length of the reference magnitude vector
              as a fraction of the viewport width. Based on this value a reference length in NDC
              units is established, from which the length of all vectors in the plot is derived.
              The relationship between magnitude and length also depends on the setting of the
              minimum vector magnitude fraction parameter, VFR, but, given the default value of
              VFR (0.0), the length of each vector is simply proportional to its relative
              magnitude. Note that the arrow size parameters, AMN and AMX, allow independent
              control over the minimum and maximum size of the vector arrowheads.

              Given a reference length, Vectors calculates a maximum length based on the ratio of
              the reference magnitude to the larger of the maximum magnitude in the data set and
              the reference magnitude itself. This length is accessible in units of NDC via the
              read-only parameter, DMX. If VRL is set less than or equal to 0.0, VVINIT
              calculates a default value for DMX, based on the size of a grid box assuming a
              linear mapping from grid coordinates to NDC space. The value chosen is one half the
              diagonal length of a grid box. By retrieving the value of DMX and calling GETSET to
              retrieve the viewport boundaries after the call to VVINIT, you can make relative
              adjustments to the vector length, as shown by the following example, where the
              maximum vector length is set to 1.5 times its default value:

               CALL VVINIT(...
               CALL VVGETR(´DMX - NDC Maximum Vector Size´, DMX)
               CALL GETSET(VL,VR,VB,VT,UL,UR,UB,UT,LL)
               VRL = 1.5 * DMX / (VR - VL)
               CALL VVSETR(´VRL - Vector Realized Length´, VRL)
               CALL VVECTR(...

              When VVECTR sees that VRL is greater than 0.0, it will calculate a new value for
              DMX. If VRL is never set, the initially calculated value of DMX is used as the
              reference length. Do not rely on the internal parameters used for setting the
              viewport, VPL, VPR, VPB and VPT to retrieve information about viewport in lieu of
              using the GETSET call. These values are ignored entirely if the SET parameter is
              zero, and even if used, the viewport may be adjusted from the specified values
              depending on the setting of the viewport shape parameter, VPS. See also the
              descriptions of VFR, VRM, and VHC. The default value of VRL is 0.0.

       VRM - Vector Reference Magnitude - Real
              The introduction of the parameter VRM means that it is now possible to specify an
              arbitrary vector magnitude as the reference magnitude appearing in the "Maximum
              Vector Text Block" annotation. The reference magnitude no longer needs to be
              greater or equal to the largest magnitude in the data set.  When VRM has a value
              greater than 0.0, it specifies the magnitude of the vector arrow drawn at the
              reference length. See VRL for an explanation of how the reference length is
              determined. If VRM is less than or equal to 0.0, the reference magnitude is
              determined by the value of VHC, the vector high cutoff value. If, in turn, VHC is
              equal to 0.0 the maximum magnitude in the vector field data set becomes the
              reference magnitude. The default value of VRM is 0.0.

       VST - Vector Statistics Output Flag - Integer
              If VST is set to one, VVECTR writes a summary of its operation to the default
              logical output unit, including the number of vectors plotted, number of vectors
              rejected, minimum and maximum vector magnitudes, and if coloring the vectors
              according to data in the scalar array, the maximum and minimum scalar array values
              encountered. Here is a sample of the output:

               VVECTR Statistics
                                   Vectors plotted:  906
               Vectors rejected by mapping routine:  0
                   Vectors under minimum magnitude:  121
                    Vectors over maximum magnitude:  0
                         Other zero length vectors:  0
                           Rejected special values:  62
                  Minimum plotted vector magnitude:  9.94109E-02
                  Maximum plotted vector magnitude:      1.96367
                              Minimum scalar value:     -1.00000
                              Maximum scalar value:      1.00000

       VSV - V Array Special Value - Real
              VSV is the V vector component array special value. It is a value outside the range
              of the normal data used to indicate that there is no valid data for this grid
              location. When SVF is set to 2 or 3, Vectors will not draw a vector whose V
              component has the special value. You must initialize Vectors with a call to VVINIT
              after modifying this parameter. It has a default value of 1.0 E12.

       WBA - Wind Barb Angle - Real

              WBA sets the angle of the wind barb ticks in degrees as measured clockwise from the
              vector direction. It also sets the angle between the hypotenuse of the triangle
              defining the pennant polygon and the vector direction. You can render southern
              hemisphere wind barbs, which by convention, have their ticks and pennants on the
              other side of the shaft, by setting WBA to a negative value. WBA has an effect only
              when AST has the value 2.

       WBC - Wind Barb Calm Circle Size - Real

              WBC sets the diameter of the circle used to represent small vector magnitudes (less
              than 2.5) as a fraction of the overall wind barb length (the value of the VRL
              parameter). WBC has an effect only when AST has the value 2.

       WBD - Wind Barb Distance Between Ticks - Real

              WBD sets the distance between adjacent wind barbs ticks along the wind barb shaft
              as a fraction of the overall wind barb length (the value of the VRL parameter).
              Half this distance is used as the spacing between adjacent wind barb pennants. Note
              that there is nothing to to prevent ticks and/or pennants from continuing off the
              end of the shaft if a vector of high enough magnitude is encountered. You are
              responsible for adjusting the parameters appropriately for the range of magnitudes
              you need to handle. WBD has an effect only when AST has the value 2.

       WBS - Wind Barb Scale Factor - Real

              WBS specifies a factor by which magnitudes passed to the wind barb drawing routines
              are to be scaled. It can be used to convert vector data given in other units into
              the conventional units used with wind barbs, which is knots. For instance, if the
              data are in meters per second, you could set WBS to 1.8974 to create a plot with
              conventional knot-based wind barbs. Note that setting WBS does not currently have
              any effect on the magnitude values written into the maximum or minimum vector
              legends.  WBS has an effect only when AST has the value 2.

       WBT - Wind Barb Tick Size - Real

              WBT the length of the wind barb ticks as a fraction of the overall length of a wind
              barb (the value of the VRL parameter). The wind barb length is defined as the
              length of the wind barb shaft plus the projection of a full wind barb tick along
              the axis of the shaft. Therefore, increasing the value of WBT, for a given value of
              VRL has the effect of reducing the length of the shaft itself somewhat. You may
              need to increase VRL itself to compensate. WBT also sets the hypotenuse length of
              the triangle defining the pennant polygon. WBT has an effect only when AST has the
              value 2.

       WDB - Window Bottom - Real
              When VVINIT does the call to SET, the parameter WDB is used to determine argument
              number 7, the user Y coordinate at the bottom of the window. If WDB is not equal to
              WDT, WDB is used. If WDB is equal to WDT, but YC1 is not equal to YCN, then YC1 is
              used. Otherwise, the value 1.0 is used. You must initialize Vectors with a call to
              VVINIT after modifying this parameter. The default value of WDB is 0.0.

       WDL - Window Left - Real
              When VVINIT the call to SET, the parameter WDL is used to determine argument number
              5, the user X coordinate at the left edge of the window. If WDL is not equal to
              WDR, WDL is used. If WDL is equal to WDR, but XC1 is not equal to XCM, then XC1 is
              used. Otherwise, the value 1.0 is used. You must initialize Vectors with a call to
              VVINIT after modifying this parameter. The default value of WDL is 0.0.

       WDR - Window Right - Real
              When VVINIT does the call to SET, the parameter WDR is used to determine argument
              number 6, the user X coordinate at the right edge of the window. If WDR is not
              equal to WDL, WDR is used. If WDR is equal to WDL, but XCM is not equal to XC1,
              then XCM is used.  Otherwise, the value of the VVINIT input parameter, M, converted
              to a real, is used. You must initialize Vectors with a call to VVINIT after
              modifying this parameter. The default value of WDR is 0.0.

       WDT - Window Top - Real
              When VVINIT does the call to SET, the parameter WDB is used to determine argument
              number 8, the user Y coordinate at the top of the window. If WDT is not equal to
              WDB, WDT is used. If WDT is equal to WDB, but YCN is not equal to YC1 then YCN is
              used. Otherwise, the value of the VVINIT input parameter, N, converted to a real,
              is used.  You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of WDT is 0.0.

       XC1 - X Coordinate at Index 1 - Real
              The parameter XC1 specifies the X coordinate value that corresponds to a value of 1
              for the first subscript of the U, V, vector component arrays as well as for the P
              scalar data array, if used. Together with XCM, YC1, and YCN it establishes the
              mapping from grid coordinate space to data coordinate space. If XC1 is equal to
              XCM, 1.0 will be used. You must initialize Vectors with a call to VVINIT after
              modifying this parameter. The default value of XC1 is 0.0.

       XCM - X Coordinate at Index M - Real
              The parameter XCM specifies the X coordinate value that corresponds to the value of
              the VVINIT input parameter, M, for the first subscript of the U and V vector
              component arrays as well as for the P scalar data array, if used.  Together with
              XC1, YC1, and YCN it establishes the mapping from grid coordinate space to data
              coordinate space. If XC1 is equal to XCM, the value of M, converted to a real, will
              be used. You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of XCM is 0.0.

       XIN - X Axis Array Increment (Grid) - Integer
              XIN controls the step size through first dimensional subscripts of the U,V vector
              component arrays and also through the P scalar data array if it is used. For dense
              arrays plotted at a small scale, you could set this parameter to a value greater
              than one to reduce the crowding of the vectors and hopefully improve the
              intelligibility of the plot. The grid point with subscripts (1,1) is always
              included in the plot, so if XIN has a value of three, for example, only grid points
              with first dimension subscripts 1, 4, 7... (and so on) will be plotted. See also
              YIN. You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of XIN is 1.

       YC1 - Y Coordinate at Index 1 - Real
              The parameter YC1 specifies the Y coordinate value that corresponds to a value of 1
              for the first subscript of the U, V, vector component arrays as well as for the P
              scalar data array, if used. Together with YCN, XC1, and XCM it establishes the
              mapping from grid coordinate space to data coordinate space. If YC1 is equal to
              YCN, 1.0 will be used. You must initialize Vectors with a call to VVINIT after
              modifying this parameter. The default value of YC1 is 0.0.

       YCN - Y Coordinate at Index N - Real
              The parameter YCN specifies the Y coordinate value that corresponds to the value of
              the VVINIT input parameter, N, for the second subscript of the U and V vector
              component arrays as well as the P scalar data array, if used.  Together with YC1,
              XC1, and XCM it establishes the mapping from grid coordinate space to data
              coordinate space. If YC1 is equal to YCN, the value of N, converted to a real, will
              be used. You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of YCN is 0.0.

       YIN - Y Axis Array Increment (Grid) - Integer
              YIN controls the step size through the second dimension subscripts of the U and V
              vector component arrays and also through the P scalar data array if it is used. For
              dense arrays plotted at a small scale, you could set this parameter to a value
              greater than one to reduce the crowding of the vectors and hopefully improve the
              intelligibility of the plot. The grid point with subscripts (1,1) is always
              included in the plot, so if YIN has a value of three, for example, only grid points
              with second dimension subscripts 1, 4, 7... (and so on) will be plotted. See also
              XIN. You must initialize Vectors with a call to VVINIT after modifying this
              parameter. The default value of YIN is 1.

       ZFC - Zero Field Text Block Color - Integer
              If ZFC is greater or equal to zero, it specifies the GKS color index to use to
              color the Zero Field text block.  Otherwise the Zero Field text block is colored
              using the current GKS text color index. The default value of ZFC is -1.

       ZFP - Zero Field Text Block Positioning Mode - Integer
              The ZFP parameter allows you to justify, using any of the 9 standard justification
              modes, the Zero Field text block unit with respect to the position established by
              the parameters, ZFX and ZFY The position modes are supported as follows:

              Mode           Justification

              -4             The lower left corner of the text block is positioned at ZFX, ZFY.

              -3             The center of the bottom edge is positioned at ZFX, ZFY.

              -2             The lower right corner is positioned at ZFX, ZFY.

              -1             The center of the left edge is positioned at ZFX, ZFY.

              0 (default)    The text block is centered along both axes at ZFX, ZFY.

              1              The center of the right edge is positioned at ZFX, ZFY.

              2              The top left corner is positioned at ZFX, ZFY.

              3              The center of the top edge is positioned at ZFX, ZFY.

              4              The top right corner is positioned at ZFX, ZFY.

       ZFS - Zero Field Text Block Character Size - Real
              ZFS specifies the size of the characters used in the Zero Field graphics text block
              as a fraction of the viewport width. The default value is 0.033.

       ZFT - Zero Field Text String - Character* 36
              Use ZFT to modify the text of the Zero Field text block.  The Zero Field text block
              may appear whenever the U and V vector component arrays contain data such that all
              the grid points otherwise eligible for plotting contain zero magnitude vectors.
              Currently the string length is limited to 36 characters. Set ZFT to a single space
              (´ ´) to prevent the text from being displayed. The default value for the text is
              ´Zero Field´.

       ZFX - Zero Field Text Block X Coordinate - Real
              ZFX establishes the X coordinate of the Zero Field graphics text block as a
              fraction of the viewport width. Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions to the left or right of the
              viewport. The actual position of the block relative to ZFX depends on the value
              assigned to the Zero Field Positioning Mode parameter, ZFP. The default value is
              0.5.

       ZFY - Zero Field Text Block Y Coordinate - Real
              ZFY establishes the Y coordinate of the minimum vector graphics text block as a
              fraction of the viewport height.  Values less than 0.0 or greater than 1.0 are
              permissible and respectively represent regions below and above the viewport. The
              actual position of the block relative to ZFY depends on the value assigned to the
              Zero Field Positioning Mode parameter, ZFP. The default value is 0.5.

SEE ALSO

       Online: vectors, vvectr, vvgetc, vvgeti, vvgetr, vvinit, vvrset, vvsetc, vvseti, vvsetr.
       vvudmv, vvumxy, ncarg_cbind.

       Hardcopy: NCAR Graphics Fundamentals, UNIX Version

COPYRIGHT

       Copyright (C) 1987-2009
       University Corporation for Atmospheric Research
       The use of this Software is governed by a License Agreement.