Provided by: sg3-utils_1.46-3ubuntu2.1_amd64 bug

NAME

       sg_write_x - SCSI WRITE normal/ATOMIC/SAME/SCATTERED/STREAM, ORWRITE commands

SYNOPSIS

       sg_write_x   [--16]   [--32]   [--app-tag=AT]   [--atomic=AB]   [--bmop=OP,PGP]  [--bs=BS]
       [--combined=DOF]   [--dld=DLD]   [--dpo]   [--dry-run]   [--fua]    [--generation=EOG,NOG]
       [--grpnum=GN]   [--help]   --in=IF  [--lba=LBA[,LBA...]]  [--normal]  [--num=NUM[,NUM...]]
       [--offset=OFF[,DLEN]]  [--or]  [--quiet]  [--ref-tag=RT]  [--same=NDOB]   [--scat-file=SF]
       [--scat-raw]  [--scattered=RD]  [--stream=ID]  [--strict]  [--tag-mask=TM]  [--timeout=TO]
       [--unmap=U_A] [--verbose] [--version] [--wrprotect=WPR] DEVICE

       Synopsis per supported command:

       sg_write_x --normal --in=IF [--16] [--32]  [--app-tag=AT]  [--bs=BS]  [--dld=DLD]  [--dpo]
       [--fua]   [--grpnum=GN]   [--lba=LBA]   [--num=NUM]  [--offset=OFF[,DLEN]]  [--ref-tag=RT]
       [--strict] [--tag-mask=TM] [--timeout=TO] [--wrprotect=WPR] DEVICE

       sg_write_x  --or  --in=IF  [--16]  [--32]  [--bmop=OP,PGP]   [--bs=BS]   [--dpo]   [--fua]
       [--generation=EOG,NOG]   [--grpnum=GN]   [--lba=LBA]   [--num=NUM]   [--offset=OFF[,DLEN]]
       [--strict] [--timeout=TO] [--wrprotect=OPR] DEVICE

       sg_write_x --atomic=AB --in=IF [--16]  [--32]  [--app-tag=AT]  [--bs=BS]  [--dpo]  [--fua]
       [--grpnum=GN]  [--lba=LBA]  [--num=NUM]  [--offset=OFF[,DLEN]]  [--ref-tag=RT]  [--strict]
       [--timeout=TO] [--wrprotect=WPR] DEVICE

       sg_write_x  --same=NDOB   [--16]   [--32]   [--app-tag=AT]   [--bs=BS]   [--dpo]   [--fua]
       [--grpnum=GN]   [--in=IF]  [--lba=LBA]  [--num=NUM]  [--offset=OFF[,DLEN]]  [--ref-tag=RT]
       [--strict] [--timeout=TO] [--unmap=U_A] [--wrprotect=WPR] DEVICE

       sg_write_x --scattered=RD  --in=IF  [--16]  [--32]  [--app-tag=AT]  [--bs=BS]  [--dld=DLD]
       [--dpo]      [--fua]      [--grpnum=GN]     [--lba=LBA[,LBA...]]      [--num=NUM[,NUM...]]
       [--offset=OFF[,DLEN]]    [--ref-tag=RT]    [--scat-file=SF]    [--scat-raw]     [--strict]
       [--tag-mask=TM] [--timeout=TO] [--wrprotect=WPR] DEVICE

       sg_write_x  --stream=ID  --in=IF  [--16]  [--32]  [--app-tag=AT] [--bs=BS] [--dpo] [--fua]
       [--grpnum=GN]  [--lba=LBA]  [--num=NUM]  [--offset=OFF[,DLEN]]  [--ref-tag=RT]  [--strict]
       [--tag-mask=TM] [--timeout=TO] [--wrprotect=WPR] DEVICE

DESCRIPTION

       This  utility  will send one of six SCSI commands, all associated with writing data to the
       given DEVICE. They are  a  "normal"  WRITE,  ORWRITE,  WRITE  ATOMIC,  WRITE  SAME,  WRITE
       SCATTERED  or  WRITE  STREAM. This utility supports the 16 and 32 byte variants of all six
       commands. Hence some closely related commands are not supported (e.g. WRITE(10)).  All  32
       byte  variants,  apart from ORWRITE(32), require the DEVICE to be formatted with type 1, 2
       or 3 Protection Information (PI), making all logical blocks 8 bytes (or a  multiple  of  8
       bytes) longer on the media.

       The  command  line  interface  is  a  little  crowded  with over thirty options. Hence the
       SYNOPSIS, after listing all the (long) options, lists those applicable to  each  supported
       command.  For  each  command  synopsis,  the option that selects the SCSI command is shown
       first followed by any required options. If no command option  is  given  then  a  "normal"
       WRITE is assumed. Even though the --scat-file=SF option can be given for every command, it
       is only shown for WRITE SCATTERED where it is most useful. If the --scat-file=SF option is
       given  then  neither  the  --lba=LBA[,LBA...] nor the --num=NUM[,NUM...] options should be
       given. Only the first item of the --lba=LBA[,LBA...] and  the  --num=NUM[,NUM...]  options
       (or  first pair (or quintet) from the --scat-file=SF option) is used for all but the WRITE
       SCATTERED command. All commands can take --dry-run and  --verbose  in  addition  to  those
       shown in the SYNOPSIS.

       The  logical  block size in bytes can be given explicitly with the --bs=BS option, as long
       as BS is greater than zero. It is typically a power of two, 512 or greater. If the --bs=BS
       option  is not given or BS is zero then the SCSI READ CAPACITY command is used to find the
       logical block size. First the READ CAPACITY(16) command is tried  and  if  successful  the
       logical  block  size  in  the response is typically used as the actual block size for this
       utility. The exception is when PROT_EN is set in  the  response  and  the  --wrprotect=WPR
       option  is  given and non-zero; in which case 8 (bytes) is added to the logical block size
       to yield the actual block size used by this utility. If READ CAPACITY(16) fails then  READ
       CAPACITY(10)  is  tried  and  if that works then the logical block size in the response is
       used as the actual block size.

       The number of bytes this utility will attempt to read from the file named  by  IF  is  the
       product  of  the  actual  block  size  and  the  number_of_blocks  (NUM  or the sum of NUM
       arguments). If less bytes are read from the file IF and the --strict option is given  then
       this  utility  exits with an exit status of SG_LIB_FILE_ERROR. If less bytes are read from
       the file IF and the --strict option is not given then bytes of zero  are  substituted  for
       the "missing" bytes and this utility continues.

       Attempts  to write multi megabyte data with a single command are likely to fail for one of
       several reasons. First the operating system might  object  to  allocating  a  buffer  that
       large.  Next  the SCSI pass-through usually limits data blocks to a few megabytes or less.
       Finally the storage device might have a limited amount of RAM to support a write operation
       such  as  atomic  (as  it  may  need  to  roll  back).  The  storage device can inform the
       application client of its limitations via the block  limits  VPD  page  (0xb0),  with  the
       maximum atomic transfer length field amongst others.

       A degenerate LBA (Logical Block Address) range descriptor with no PI has an LBA and NUM of
       zero. A degenerate LBA range descriptor with PI additionally has its RT, AT and TM  fields
       set  to zero (note: that is not the default values for RT, AT and TM). They are degenerate
       in the sense that they are indistinguishable from a pad of zeros that follow  the  scatter
       list  in  the data-out buffer. SBC-4 makes clear that a degenerate LBA range descriptor is
       valid. This may become an issue if RD given in the --scattered=RD option has the value  0.
       In  this case the logic may need to scan the user provided data to calculate the number of
       LBA range descriptors which is required by the WRITE SCATTERED  cdb.  In  the  absence  of
       other information the logic will take a degenerate LBA range descriptor as a terminator of
       the scatter list.

       The current reference for these commands is draft SBC-4 (T10/BSR INCITS 506)  revision  15
       dated  9 November 2017. All six SCSI commands are described in that document. WRITE ATOMIC
       was added in SBC-4 revision 3; WRITE STREAM was added in SBC-4 revision 7; WRITE SCATTERED
       was added in SBC-4 revision 11 while the others are in the SBC-3 standard.

OPTIONS

       Arguments  to  long  options  are  mandatory  for  short options as well.  The options are
       arranged in alphabetical order based on the long option name.

       -6, --16
              send the 16 byte cdb variant of  the  selected  SCSI  command.  If  no  command  is
              selected  then  the (normal) SCSI WRITE(16) command is sent. If neither this option
              nor the --32 option is given then this option is assumed.

       -3, --32
              send the 32 byte cdb variant of  the  selected  SCSI  command.  If  no  command  is
              selected  then  the (normal) SCSI WRITE(32) command is sent. If neither this option
              nor the --16 option is given then then the --16 option is  assumed.  If  both  this
              option  and  the --16 option are given then this option takes precedence. Note that
              apart from ORWRITE(32) all other 32 byte cdb variants require  a  DEVICE  formatted
              with type 1, 2 or 3 protection information.

       -a, --app-tag=AT
              where AT is the "expected logical block application tag" field found in most of the
              32 byte cdb variants (the exception is ORWRITE(32)). AT is a  16  bit  field  which
              means the maximum value is 0xffff. The default value is 0xffff .

       -A, --atomic=AB
              selects  the  WRITE ATOMIC command and AB is placed in the Atomic Boundary field of
              its cdb. It is a 16 bit field so the maximum value is 0xffff. If unsure what  value
              to  set,  try  0  which will attempt to write the whole data-out buffer in a single
              atomic operation.

       -B, --bmop=OP,PGP
              where OP and PGP are the values to be placed in ORWRITE(32)'s  BMOP  and  'Previous
              Generation Processing' fields respectively. BMOP is a 3 bit field (ranges from 0 to
              7) and PGP is a 4 bit field (ranges from 0 to 15). Both fields default to 0.

       -b, --bs=BS
              where BS is the logical block size or the actual block size which will be  slightly
              bigger.  The  default value is zero. If this option is not given or is given with a
              BS of zero then the SCSI READ CAPACITY(16) command is sent to DEVICE. If that fails
              then  the READ CAPACITY(10) command is sent. The logical and actual block size will
              be derived from the response of the READ CAPACITY command.
              This section assumes BS is greater than zero. If BS is less than 512 (bytes) or not
              a  multiple of 8, a warning is issued and the utility continues unless the --strict
              option is also given. If BS is a power of two  (e.g.  512)  then  the  logical  and
              actual  block  size is set to BS (e.g. 512). If BS is not a power of two (e.g. 520)
              then the logical block size is set to the closest power of two less than  BS  (e.g.
              512) and the actual block size is set to BS (e.g.  520).
              If  the  logical and actual block size are different then a later check will reduce
              the actual block size back to the logical  block  size  unless  --wrprotect=WPR  is
              greater than zero.

       -c, --combined=DOF
              This  option  only applies to WRITE SCATTERED and assumes the whole data-out buffer
              can be read from IF given by the --in=IF option. The whole data-out buffer  is  the
              parameter  list  header, followed by zero or more LBA range descriptors, optionally
              followed by some pad bytes and then the data to be written to  the  media.  If  the
              --lba=LBA[,LBA...],  --num=NUM[,NUM...]  or  --scat-file=SF  options are also given
              then an error is generated. The DOF argument should be the value suitable  for  the
              'Logical Block Data Offset' field in the WRITE SCATTERED cdb. This is the offset in
              the data-out buffer where the data to write to the media  commences.  The  unit  of
              that field is the actual block size which is the logical block size plus a multiple
              of 8, if protection information (PI) is being sent. When WPR (from --wrprotect=WPR)
              is  greater  than zero then PI is expected. SBC-4 revision 15 does not state it but
              it would appear that a DOF value of 0 is invalid. It is suggested that this  option
              be  used  with  the --strict option while experimenting as random or incorrect data
              fed in via the --in=IF option could write a lot of "interesting" data all over  the
              DEVICE.   If  DOF  is  given as 0 the utility will scan the data in IF until RD LBA
              range descriptors are found; or if RD is  also  0  until  a  degenerate  LBA  range
              descriptor is found.

       -D, --dld=DLD
              where  DLD  is  the  duration  limits  descriptor  spread across 3 bits in the SCSI
              WRITE(16) and the WRITE SCATTERED(16) cdbs. DLD is between 0 to 7 inclusive with  a
              default of zero. The DLD0 field in WRITE(16) and WRITE SCATTERED(16) is set if (0x1
              & DLD) is non-zero. The DLD1 field in both cdbs is set if (0x2 & DLD) is  non-zero.
              The DLD2 field in both cdbs is set if (0x4 & DLD) is non-zero.

       -d, --dpo
              if  this  option  is  given then the DPO (disable page out) bit field in the cdb is
              set. The default is to clear this bit field. Applies to all commands  supported  by
              thus utility except WRITE SAME.

       -x, --dry-run
              this  option  exits  (with  a  status of 0) just before it would otherwise send the
              selected SCSI write command. It may still send a SCSI  READ  CAPACITY  command  (16
              byte  variant and perhaps 10 byte variant as well) so the DEVICE is still required.
              It reads the data in and processes it if  the  --in=IF  and/or  the  --scat-file=SF
              options  are  given.  All  command  line  processing and sanity checks (e.g. if the
              --strict option is given) will be performed and if there is  an  error  then  there
              will be a non zero exit status value.
              If  this  option  is given twice (e.g. -xx) then instead of performing the selected
              write SCSI command, the data-out buffer is written to a file called  sg_write_x.bin
              .  If  it  doesn't  exist then that file is created in the current directory and is
              truncated if it previously did exist with longer contents. The data-out  buffer  is
              written  in  binary  with  some  information about it written to stdout. For writes
              other than scattered the filename and its length in bytes is output to stdout.  For
              write  scattered  additionally  its number of LBA range descriptors and its logical
              block data offset written to stdout.

       -f, --fua
              if this option is given then the FUA (force unit access) bit field in  the  cdb  is
              set.  The  default is to clear this bit field. Applies to all commands supported by
              thus utility except WRITE SAME.

       -G, --generation=EOG,NOG
              the arguments for this option are used by the  ORWITE(32)  command  only.   EOG  is
              placed  in  the  "Expected  ORWgeneration"  field  while  NOG is placed in the "New
              ORWgeneration" field. Both are 32 bits long and default to zero.

       -g, --grpnum=GN
              sets the 'Group number' field to GN. Defaults to a value of zero.  GN should  be  a
              value between 0 and 63.

       -h, --help
              output  the  usage  message then exit. Use multiple times for more help.  Currently
              '-h' to '-hhhh' provide different output.

       -i, --in=IF
              read data (in binary) from a file named IF in a single OS  system  call  (in  Unix:
              read(2)).  That data is placed in a continuous buffer and then used as the data-out
              buffer for all SCSI write commands apart from WRITE SCATTERED(16 or 32)  which  may
              include  other  data  in  the  data-out buffer.  For WRITE SCATTERED (16 or 32) the
              data-out buffer is made up of 3 or 4 components in this  order:  a  parameter  list
              header  (32  zero  bytes);  zero or more LBA range descriptors, optionally some pad
              bytes (zeros) and then data to write to the media.  For  WRITE  SCATTERED  IF  only
              provides  the  data  to write to the media unless --combined=DOF is given. When the
              --combined=DOF option is given IF contains all components of  the  WRITE  SCATTERED
              data-out  buffer in binary. The data read from IF starts from byte offset OFF which
              defaults to zero and no more than DLEN bytes are read from that  point  (i.e.  from
              the  file byte offset OFF). If DLEN is zero or not given the rest of the file IF is
              read. This option is mandatory apart from when --same=1 is  given  (that  sets  the
              NDOB  bit which stands for "No Data Out Buffer"). In Unix based OSes, any number of
              zeros can be produced by using the /dev/zero device file.
              IF may be "-" which is taken as stdin. In this case the  --offset=OFF,DLEN  can  be
              given  with  OFF set to 0 and LEN set to a non-zero value, preferably a multiple of
              the actual block size. The utility can also deduce how long the IF should  be  from
              NUM (or the sum of them in the case of a scatter list).

       -l, --lba=LBA[,LBA...]
              where  the  argument  is  a single Logical Block Address (LBA) or a comma separated
              list of LBAs each of which is the  address  of  the  first  block  written  by  the
              selected  write  command.  Only  the WRITE SCATTERED command can usefully take more
              than one LBA. Whatever number of LBAs is given, there needs to be an  equal  number
              of  NUMs given to the --num=NUM[,NUM...] option. The first given LBA joins with the
              first given NUM to form the first LBA range descriptor (which T10 number from  zero
              in  SBC-4).  The  second LBA joins with the second LBA to form the second LBA range
              descriptor, etc. A more convenient way to  define  a  large  number  of  LBA  range
              descriptors  is  with the --scat-file=SF option. Defaults to logical block 0 (which
              could be dangerous) while NUM defaults to 0 which makes the  combination  harmless.
              LBA is assumed to be in decimal unless prefixed with '0x' or has a trailing 'h'.

       -N, --normal
              the  choice of a "normal" WRITE (16 or 32) command can be made explicitly with this
              option. In the absence of selecting any other command  (e.g.   --atomic=AB  ),  the
              choice of a "normal" WRITE is the default.

       -n, --num=NUM[,NUM...]
              where  the argument is a single NUMber of blocks (NUM) or a comma separated list of
              NUMs that pair with the corresponding entries in the --lba=LBA[,LBA...] option.  If
              a  NUM  is  given  and  is  not  provided  by  another  method  (e.g.  by using the
              --scat-file=SF option) then it defaults to the number of blocks  derived  from  the
              size of the file named by IF (starting at byte offset OFF to the end or the file or
              DLEN). Apart from the --combined=DOF  option,  an  LBA  must  be  explicitly  given
              (either  with  I--lba=LBA  or  via  --scat-file=SF),  if not NUM defaults to 0 as a
              safety measure.

       -o, --offset=OFF[,DLEN]
              where OFF is the byte offset within the file named IF to start  reading  from.  The
              default  value  of OFF is zero which is the beginning of file named IF. DLEN is the
              maximum number of bytes to read, starting at byte offset OFF, from the  file  named
              IF.  Less  bytes will be read if an end of file occurs before DLEN is exhausted. If
              DLEN is zero or not given then reading from byte offset OFF to the end of the  file
              named IF is assumed.

       -O, --or
              selects the ORWRITE command. ORWRITE(16) has similar fields to WRITE(16) apart from
              the WRPROTECT field being named ORPROTECT with slightly different semantics and the
              absence  of  the  3  DLD bit fields. ORWRITE(32) has four extra fields that are set
              with the --bmop=OP,PGP and --generation=EOG,NOG options. ORWRITE(32) is the only 32
              byte cdb command in this utility that does not require a DEVICE formatted with type
              1, 2 or 3 PI (although it will still work if it is formatted with PI).

       -Q, --quiet
              suppress some informational messages such as  the  ones  associated  with  detected
              errors  when this utility is about to exit. The exit status value is still returned
              to the operating system when this utility exits.

       -r, --ref-tag=RT
              where RT is the "expected initial logical block reference tag" field found  in  the
              32  byte  cdb  variants  of  WRITE, WRITE ATOMIC, WRITE SAME and WRITE STREAM.  The
              field is also found in the WRITE SCATTERED(32) LBA range descriptors. It  is  a  32
              bit  field  which  means  the  maximum  value  is  0xffffffff. The default value is
              0xffffffff.

       -S, --same=NDOB
              selects the WRITE SAME command with the NDOB field set to NDOB which stands for  No
              Data-Out  Buffer. NDOB can take values 0 or 1 (i.e. it is a single bit field). When
              --same=1 all options associated with the data-out buffer are ignored.

       -q, --scat-file=SF
              where SF is the name of an auxiliary file containing the scatter list for the WRITE
              SCATTERED  command.  If  the  --scat-raw option is also given then SF is assumed to
              contain both the parameter list header (32 bytes of zeros) followed by zero or more
              LBA  range  descriptors  which are also 32 bytes long each. These components are as
              defined by SBC-4 (i.e.  in binary with integers  in  big  endian  format).  If  the
              --scat-raw  option  is  not  given  then a file of ACSII hexadecimal is expected as
              described in the SCATTERED FILE ASCII FORMAT section below.
              If this option is given with the --combined=DOF option then this utility will  exit
              with  a  syntax  error.  SF  must  not be "-", a way of stopping the user trying to
              redirect stdin.

       -R, --scat-raw
              this option only effects the way that the file named  SF  from  the  --scat-file=SF
              option  for  WRITE SCATTERED is interpreted. By default (i.e. without this option),
              SF is parsed as ASCII hexadecimal with blank  lines  and  line  contents  from  and
              including  '#'  to the end of line ignored. Hence it can contain comments and other
              indications. When this option is given, the file named SF is interpreted as binary.
              As binary it is assumed to contain 32 bytes of zeros (the WRITE SCATTERED parameter
              list header) followed by zero or more LBA range descriptors  (which  are  32  bytes
              each).  If  the  --strict option is given the reserved field in those two items are
              checked with any non zero bytes causing an error.

       -S, --scattered=RD
              selects the WRITE  SCATTERED  command  with  RD  being  the  number  of  LBA  range
              descriptors  that  will  be  placed  in the data-out buffer. If RD is zero then the
              logic will try and determine the number of range descriptors by other  means  (e.g.
              by  parsing  the  file  named  by  SF, if there is one).  The LBA range descriptors
              differ between the 16 and 32 byte cdb variants of WRITE SCATTERED. In the  16  byte
              cdb  variant the 32 byte LBA range descriptor is made up of an 8 byte LBA, followed
              by a 4 byte number_of_blocks followed by 20 bytes of zeros. In the 32 byte  variant
              the  LBA and number_of_blocks are followed by a RT (4 bytes), an AT (2 bytes) and a
              TM (2 bytes) then 12 bytes of zeros.
              This paragraph applies when RD is greater than zero.  If RD is less than the number
              of  LBA  range descriptors built from command line options, from the --scat-file=SF
              option or decoded from IF (when the --combined=DOF option is given) then  RD  takes
              precedence;  so  RD is placed in the "Number of LBA Range Descriptors" field in the
              cdb. If RD is greater than the number of  LBA  range  descriptors  found  from  the
              provided data and options, then an error is generated.

       -T, --stream=ID
              selects  the  WRITE  STREAM  command  with the STR_ID field set to ID.  ID can take
              values from 0 to 0xffff (i.e. it is a 16 bit field).

       -s, --strict
              when this option is present, more things (e.g. that reserved fields contain  zeros)
              and  any  irregularities will terminate the utility with a message to stderr and an
              indicative exit status. While experimenting with these commands,  especially  WRITE
              SCATTERED, it is recommended to use this option.

       -t, --tag-mask=TM
              where  TM  is  the "logical block application tag mask" field  found in the 32 byte
              cdb variants of WRITE, WRITE ATOMIC, WRITE SAME and WRITE STREAM. The field is also
              found  in the WRITE SCATTERED(32) LBA range descriptors. It is a 16 bit field which
              means the maximum value is 0xffff. The default value is 0xffff.

       -I, --timeout=TO
              where TO is the command timeout value in seconds. The default value is 120 seconds.
              If  NUM  is  large on slow media then these WRITE commands may require considerably
              more time than 120 seconds to complete.

       -u, --unmap=U_A
              where U_A is OR-ed bit values used to set the UNMAP and ANCHOR bit  fields  in  the
              WRITE SAME (16 or 32) cdb. If U_A is 1 then the UNMAP bit field is set; if U_A is 2
              then the ANCHOR bit field is set; if U_A is 3 then both the UNMAP  and  ANCHOR  bit
              fields  are set. The default value for both bit fields is clear (0); setting U_A to
              0 will also clear both bit fields.

       -v, --verbose
              increase the degree of verbosity  (debug  messages).  These  messages  are  usually
              written to stderr.

       -V, --version
              output version string then exit.

       -w, --wrprotect=WPR
              sets  the  WRPROTECT  field  (3 bits) in all sg_write_x commands apart from ORWRITE
              which has a 3 bit ORPROTECT field (and the synopsis  shows  OPR  to  highlight  the
              difference).  In  all cases WPR is placed in that 3 bit field. The default value is
              zero which does not send any PI in the data-out  buffer.  WPR  should  be  a  value
              between 0 and 7.

SCATTERED FILE ASCII FORMAT

       All  commands  in  this utility can take a --scat-file=SF and that option can be seen as a
       replacement for  the  --lba=LBA[,LBA...]  and  --num=NUM[,NUM...]  options.  if  both  the
       --scat-file=SF  and  --scat-raw options are given then the file named SF is expected to be
       binary and contain the parameter list header (32 bytes of zeros for both  the  16  and  32
       byte variants) followed by zero or more LBA range descriptors, each of 32 bytes each. This
       section describes what is expected in SF when the --scat-raw option is not given.

       The ASCII hexadecimal "scatter file" (named by SF) can contain comments, empty  lines  and
       numbers. If multiple numbers appear on one line they can be separated by spaces, tabs or a
       single comma. Numbers are parsed as decimal unless prefixed by "0x" (or "0X")  or  have  a
       suffix of "h". Ox is the prefix of hexadecimal number is the C language while T10 uses the
       "h" suffix for the same purpose. Anything from  and  including  a  "#"  character  to  the
       end-of-line is ignored, so comments can be placed there.

       For  the  WRITE  SCATTERED  (16)  command, its LBA range descriptors contain two items per
       descriptor: an 8 byte LBA followed by a 4 byte number_of_blocks.  The remaining  20  bytes
       of  the  descriptor  are  zeros. The format accepted is relatively loose with each decoded
       value being placed in an LBA and then a number_of_blocks until the end-of-file is reached.
       The  pattern  starts with a LBA and if it doesn't finish with a number_of_blocks (i.e.  an
       odd number of values are parsed) an error occurs. So the number of LBA  range  descriptors
       generated will be half the number of values parsed in SF.

       For  the  WRITE  SCATTERED  (32) command, its LBA range descriptors contain five items per
       descriptor: an 8 byte LBA followed by a 4 byte number_of_blocks, then a 4  byte  RT,  a  2
       byte  AT, and a 2 byte TM. The last three items are associated with protection information
       (PI). The accepted format in the SF file is more constrained than the 16 byte cdb variant.
       The  items  for  each  LBA  range descriptor must be found on one line with adjacent items
       being comma separated. The first two items (LBA and number_of_blocks) must be  given,  and
       if  no  more  items are on the line then RT, AT and TM are given their default values (all
       "ff" bytes). Spaces and tabs may appear between items but commas are the  separators.  Two
       commas  with  no  value  between them will cause the "missing" item to receive its default
       value.

NOTES

       Various numeric arguments (e.g. LBA) may include multiplicative suffixes or  be  given  in
       hexadecimal. See the "NUMERIC ARGUMENTS" section in the sg3_utils(8) man page.

       In Linux, prior to lk 3.17, the sg driver did not support cdb sizes greater than 16 bytes.
       Hence a device node like /dev/sg1 which is associated with the sg driver would  fail  with
       this  utility  if  the --32 option was given (or implied by other options). The bsg driver
       with device nodes like /dev/bsg/6:0:0:1 does support cdb sizes greater than 16 bytes since
       its introduction in lk 2.6.28 .

EXIT STATUS

       The  exit  status of sg_write_x is 0 when it is successful. Otherwise see the sg3_utils(8)
       man page.

EXAMPLES

       One simple usage is to write 4 blocks of zeros from (and including) a given LBA  according
       to  the  rules  of WRITE ATOMIC with an atomic boundary of 0.  Since no cdb size option is
       given, the 16 byte cdb will be assumed (i.e.  WRITE ATOMIC(16)):

         sg_write_x --atomic=0 --in=/dev/zero --lba=0x1234 --num=4 /dev/sdc

       Since --bs=BS has not been given, then  this  utility  will  call  the  READ  CAPACITY(16)
       command  on  /dev/sdc  to  determine  the  number of bytes in a logical block. If the READ
       CAPACITY(16) command fails then the READ CAPACITY(10) command is tried. Let us assume  one
       of them works and that the number of bytes in each logical block is 512 bytes. So 4 blocks
       of zeros (each block containing 512 bytes) will be written from (and including) LBA 0x1234
       . Now to bypass the need for the READ CAPACITY command(s) the --bs=BS option can be used:

         sg_write_x --atomic=0 --bs=512 --in=/dev/zero --lba=0x1234 --num=4 /dev/sdc

       Since  --bs=  is  given and its value (512) is a power of 2, then the actual block size is
       also 512. If instead 520 was given then the logical block size would be 512  (the  highest
       power  of  2  less  than 520) and the actual block size would be 520 bytes. To send the 32
       byte variant add --32 as in:

         sg_write_x --atomic=0 --32 --bs=512 --in=/dev/zero --lba=0x1234 --num=4 /dev/sdc

       For examples using 'sg_write_x --same=NDOB' see  the  manpage  for  sg_write_same(8).  The
       syntax is a little different but the semantics are the same.

       To send a WRITE STREAM(32) with a STR_ID of 1 use the following:

         sg_write_x --stream=1 --32 --bs=512 --in=/dev/zero --lba=0x1234 --num=4 /dev/sdc

       Next  is a WRITE SCATTERED(16) command with the scatter list, split between the --lba= and
       --num= options, on the command line:

         sg_write_x  --scattered=2 --lba=2,0x33 --num=4,1 -i /dev/zero /dev/sg1

       Example of a WRITE SCATTERED(16) command with a degenerate  LBA  range  descriptor  (first
       element to --lba= and --num=):

         sg_write_x  --scattered=2 --lba=0,0x33 --num=0,1 -i /dev/zero /dev/sg1

       Example of a WRITE SCATTERED(16) command with the scatter list in scat_file.txt

         sg_write_x  --scattered=3 -q scat_file.txt -i /dev/zero /dev/sg1

       Next  a  WRITE SCATTERED(16) command with its scatter list and data in a single file. Note
       that the argument to --scattered=  is  0  so  the  number  of  LBA  range  descriptors  is
       calculated  by  analyzing  the  first two blocks of scat_data.bin (because the argument to
       --combined= is 2) :

         sg_write_x  --scattered=0 --combined=2 -i scat_data.bin /dev/sg1

       When the -xx option is used, a WRITE SCATTERED command is not  executed  but  instead  the
       contents  of the data-out buffer are written to a file called sg_write_x.bin . In the case
       of WRITE SCATTERED that binary file is suitable for supplying to a later invocation to  do
       the actual write to media. For example:

         sg_write_x  --scattered=3 -q scat_file.txt -xx -i /dev/zero /dev/sg1
       Wrote 8192 bytes to sg_write_x.bin, LB data offset: 1
       Number of LBA range descriptors: 3
         sg_write_x  --scattered=0 --combined=1 -i sg_write_x.bin /dev/sg1

       Notice when the sg_write_x.bin is written (and nothing is written to the media), a summary
       of what has happened is sent to stdout. The value shown for "LB data offset:"  (1)  should
       be  given  to  the  --combined=  option  when the write to media actually occurs (i.e. the
       second invocation shown directly above).

AUTHORS

       Written by Douglas Gilbert.

REPORTING BUGS

       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

       Copyright © 2017-2020 Douglas Gilbert
       This software is distributed under a FreeBSD license. There is NO warranty; not  even  for
       MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

       sg_readcap,sg_vpd,sg_write_same,sg_stream_ctl(sg3_utils)