Provided by: mdadm_4.3-1ubuntu2_amd64 bug

NAME

       mdadm.conf - configuration for management of Software RAID with mdadm

SYNOPSIS

       /etc/mdadm.conf

DESCRIPTION

       mdadm is a tool for creating, managing, and monitoring RAID devices using the md driver in
       Linux.

       Some common tasks, such as assembling all arrays, can  be  simplified  by  describing  the
       devices and arrays in this configuration file.

   SYNTAX
       The  file should be seen as a collection of words separated by white space (space, tab, or
       newline).  Any word that beings with a hash sign  (#)  starts  a  comment  and  that  word
       together with the remainder of the line is ignored.

       Spaces  can be included in a word using quotation characters.  Either single quotes (') or
       double quotes (") may be used.  All the characters from one quotation  character  to  next
       identical  character  are  protected  and  will not be used to separate words to start new
       quoted strings.  To include a single quote it must be between double quotes.  To include a
       double quote it must be between single quotes.

       Any  line  that  starts  with  white  space  (space or tab) is treated as though it were a
       continuation of the previous line.

       Empty lines are ignored, but otherwise each (non continuation)  line  must  start  with  a
       keyword  as  listed  below.  The keywords are case insensitive and can be abbreviated to 3
       characters.

       The keywords are:

       DEVICE A device line lists the devices (whole devices or partitions) that might contain  a
              component  of an MD array.  When looking for the components of an array, mdadm will
              scan these devices (or any devices listed on the command line).

              The device line may contain a number of different devices (separated by spaces) and
              each device name can contain wild cards as defined by glob(7).

              Also, there may be several device lines present in the file.

              Alternatively,  a  device  line can contain either or both of the  words containers
              and partitions.  The word  containers  will  cause  mdadm  to  look  for  assembled
              CONTAINER arrays and included them as a source for assembling further arrays.

              The  word  partitions  will  cause  mdadm  to read /proc/partitions and include all
              devices  and  partitions  found  therein.   mdadm  does  not  use  the  names  from
              /proc/partitions  but  only  the  major and minor device numbers.  It scans /dev to
              find the name that matches the numbers.

              If no  DEVICE  line  is  present  in  any  config  file,  then  "DEVICE  partitions
              containers" is assumed.

              For example:

              DEVICE /dev/hda* /dev/hdc*
              DEV    /dev/sd*
              DEVICE /dev/disk/by-path/pci*
              DEVICE partitions

       ARRAY  The  ARRAY  lines  identify  actual arrays.  The second word on the line may be the
              name of the device where the array is  normally  assembled,  such  as  /dev/md1  or
              /dev/md/backup.   If  the  name does not start with a slash ('/'), it is treated as
              being in /dev/md/.  Alternately the word <ignore> (complete  with  angle  brackets)
              can  be given in which case any array which matches the rest of the line will never
              be automatically assembled.  If no device name is given,  mdadm  will  use  various
              heuristics to determine an appropriate name.

              Subsequent  words identify the array, or identify the array as a member of a group.
              If multiple identities are given, then a component device must match ALL identities
              to  be considered a match.  Each identity word has a tag, and equals sign, and some
              value.  The tags are:

           uuid=  The  value  should  be  a  128  bit  uuid  in  hexadecimal,  with   punctuation
                  interspersed if desired.  This must match the uuid stored in the superblock.

           super-minor=
                  The value is an integer which indicates the minor number that was stored in the
                  superblock when the array was created. When an array is  created  as  /dev/mdX,
                  then the minor number X is stored.

           devices=
                  The  value  is  a comma separated list of device names or device name patterns.
                  Only devices with names which match one entry in  the  list  will  be  used  to
                  assemble  the array.  Note that the devices listed there must also be listed on
                  a DEVICE line.

           level= The value is a RAID level.  This is not normally used to identify an array, but
                  is supported so that the output of

                  mdadm --examine --scan

                  can be use directly in the configuration file.

           num-devices=
                  The  value is the number of devices in a complete active array.  As with level=
                  this is mainly for compatibility with the output of

                  mdadm --examine --scan.

           spares=
                  The value is a number of spare devices to expect the array to have.   The  sole
                  use  of  this  keyword  and value is as follows: mdadm --monitor will report an
                  array if it is found to have fewer than this number of  spares  when  --monitor
                  starts or when --oneshot is used.

           spare-group=
                  The  value  is  a textual name for a group of arrays.  All arrays with the same
                  spare-group name are considered to be part of the same group.  The significance
                  of  a  group  of  arrays is that mdadm will, when monitoring the arrays, move a
                  spare drive from one array in a group to another array in  that  group  if  the
                  first array had a failed or missing drive but no spare.

           auto=  This option is rarely needed with mdadm-3.0, particularly if use with the Linux
                  kernel v2.6.28 or later.  It tells mdadm whether to use partitionable array  or
                  non-partitionable  arrays  and,  in  the  absence  of  udev, how many partition
                  devices to create.  From 2.6.28 all md array devices are  partitionable,  hence
                  this option is not needed.

                  The  value  of this option can be "yes" or "md" to indicate that a traditional,
                  non-partitionable md array should be created, or "mdp", "part"  or  "partition"
                  to  indicate  that  a  partitionable  md array (only available in linux 2.6 and
                  later) should be used.  This later set can  also  have  a  number  appended  to
                  indicate  how many partitions to create device files for, e.g.  auto=mdp5.  The
                  default is 4.

           bitmap=
                  The option specifies a file in which a write-intent  bitmap  should  be  found.
                  When assembling the array, mdadm will provide this file to the md driver as the
                  bitmap file.  This has  the  same  function  as  the  --bitmap-file  option  to
                  --assemble.

           metadata=
                  Specify  the metadata format that the array has.  This is mainly recognised for
                  comparability with the output of mdadm -Es.

           container=
                  Specify that this array is a member array of some container.  The  value  given
                  can be either a path name in /dev, or a UUID of the container array.

           member=
                  Specify  that  this  array  is  a member array of some container.  Each type of
                  container has some way to enumerate member  arrays,  often  a  simple  sequence
                  number.   The  value  identifies  which member of a container the array is.  It
                  will usually accompany a "container=" word.

       MAILADDR
              The mailaddr line gives an E-mail address that alerts should be sent to when  mdadm
              is  running in --monitor mode (and was given the --scan option).  There should only
              be one MAILADDR line and it should have only one address.  Any subsequent addresses
              are silently ignored.

       MAILFROM
              The mailfrom line (which can only be abbreviated to at least 5 characters) gives an
              address to appear in the "From" address for alert mails.  This can be useful if you
              want  to  explicitly  set  a  domain, as the default from address is "root" with no
              domain.  All words on this line are catenated with spaces to form the address.

              Note that this value cannot be set via the mdadm commandline.  It is only  settable
              via  the  config  file.   There should only be one MAILADDR line and it should have
              only one address.  Any subsequent addresses are silently ignored.

       PROGRAM
              The program line gives the name of a program to be run when mdadm --monitor detects
              potentially  interesting  events  on any of the arrays that it is monitoring.  This
              program gets run with two or three arguments, they being the Event, the md  device,
              and possibly the related component device.

              There should only be one program line and it should be given only one program.  Any
              subsequent programs are silently ignored.

       CREATE The create line gives default values to be used when creating arrays,  new  members
              of arrays, and device entries for arrays.

              There  should  only  be  one  create  line.  Any subsequent lines will override the
              previous settings.

              Keywords used in the CREATE line and supported values are:

           owner=

           group= These can give user/group ids or  names  to  use  instead  of  system  defaults
                  (root/wheel or root/disk).

           mode=  An octal file mode such as 0660 can be given to override the default of 0600.

           auto=  This  corresponds  to  the  --auto  flag  to  mdadm.  Give yes, md, mdp, part —
                  possibly followed by a number of partitions — to indicate  how  missing  device
                  entries should be created.

           metadata=
                  The  name  of the metadata format to use if none is explicitly given.  This can
                  be useful to impose a system-wide default of version-1 superblocks.

           names=yes
                  Since Linux 2.6.29 it has been possible to create md devices with a  name  like
                  md_home  rather  than  just  a  number,  like  md3.  mdadm will use the numeric
                  alternative by default as other tools that interact with md arrays  may  expect
                  only  numbers.   If names=yes is given in mdadm.conf then mdadm will use a name
                  when appropriate.  If names=no is given, then non-numeric md device names  will
                  not be used even if the default changes in a future release of mdadm.

           bbl=no By  default, mdadm will reserve space for a bad block list (bbl) on all devices
                  included in or added to any array that  supports  them.   Setting  bbl=no  will
                  prevent this, so newly added devices will not have a bad block log.

       HOMEHOST
              The homehost line gives a default value for the --homehost= option to mdadm.  There
              should normally be only one other word on the line.  It should  either  be  a  host
              name,  or  one  of the special words <system>, <none> and <ignore>.  If <system> is
              given, then the gethostname(2) systemcall is used to get the host  name.   This  is
              the default.

              If  <ignore>  is  given,  then  a  flag  is set so that when arrays are being auto-
              assembled the checking of the recorded homehost is disabled.  If <ignore> is  given
              it  is  also  possible  to  give  an explicit name which will be used when creating
              arrays.  This is the only case when there can be more that one other  word  on  the
              HOMEHOST  line.   If  there  are  other  words,  or  other HOMEHOST lines, they are
              silently ignored.

              If <none> is given, then the default of using gethostname(2) is over-ridden and  no
              homehost name is assumed.

              When  arrays  are  created,  this  host  name will be stored in the metadata.  When
              arrays are assembled using auto-assembly, arrays which do not  record  the  correct
              homehost  name  in  their  metadata  will  be  assembled using a "foreign" name.  A
              "foreign" name alway ends  with  a  digit  string  preceded  by  an  underscore  to
              differentiate it from any possible local name. e.g.  /dev/md/1_1 or /dev/md/home_0.

       HOMECLUSTER
              The  homcluster  line gives a default value for the --homecluster= option to mdadm.
              It specifies  the  cluster name for the md device.  The md device can be  assembled
              only  on  the  cluster  which  matches  the  name  specified.  If homcluster is not
              provided, mdadm tries to detect the cluster name automatically.

              There should only be one homecluster line.  Any subsequent lines will  be  silently
              ignored.

       AUTO   A  list  of names of metadata format can be given, each preceded by a plus or minus
              sign.  Also the word homehost is allowed as is all preceded by plus or minus  sign.
              all is usually last.

              When  mdadm is auto-assembling an array, either via --assemble or --incremental and
              it finds metadata of a given type, it  checks  that  metadata  type  against  those
              listed in this line.  The first match wins, where all matches anything.  If a match
              is found that was preceded by a plus sign, the auto assembly is  allowed.   If  the
              match  was  preceded by a minus sign, the auto assembly is disallowed.  If no match
              is found, the auto assembly is allowed.

              If the metadata indicates that the array was created for this host,  and  the  word
              homehost  appears  before  any  other  match,  then the array is treated as a valid
              candidate for auto-assembly.

              This can be used to disable all  auto-assembly  (so  that  only  arrays  explicitly
              listed  in mdadm.conf or on the command line are assembled), or to disable assembly
              of certain metadata types which might be handled by other software.  It can also be
              used to disable assembly of all foreign arrays - normally such arrays are assembled
              but given a non-deterministic name in /dev/md/.

              The known metadata types are 0.90, 1.x, ddf, imsm.

              AUTO should be given at most once.  Subsequent lines are silently ignored.  Thus  a
              later  config  file  in  a  config  directory  will not overwrite the setting in an
              earlier config file.

       POLICY This is used to specify  what  automatic  behavior  is  allowed  on  devices  newly
              appearing  in  the system and provides a way of marking spares that can be moved to
              other arrays as well as the migration  domains.   Domain  can  be  defined  through
              policy  line  by  specifying a domain name for a number of paths from /dev/disk/by-
              path/.  A device may belong to several domains. The domain of an array is  a  union
              of  domains  of all devices in that array.  A spare can be automatically moved from
              one array to another if the set of the destination array's domains contains all the
              domains of the new disk or if both arrays have the same spare-group.

              To  update  hot  plug  configuration  it is necessary to execute mdadm --udev-rules
              command after changing the config file

              Keywords used in the POLICY line and supported values are:

           domain=
                  any arbitrary string

           metadata=
                  0.9 1.x ddf or imsm

           path=  file glob matching anything from /dev/disk/by-path

           type=  either disk or part.

           action=
                  include, re-add, spare, spare-same-slot, or force-spare

           auto=  yes, no, or homehost.

           The action item determines the automatic behavior allowed  for  devices  matching  the
           path  and  type  in  the  same line.  If a device matches several lines with different
           actions then the  most  permissive  will  apply.  The  ordering  of  policy  lines  is
           irrelevant to the end result.

           include
                  allows adding a disk to an array if metadata on that disk matches that array

           re-add will  include the device in the array if it appears to be a current member or a
                  member that was recently removed and the array  has  a  write-intent-bitmap  to
                  allow the re-add functionality.

           spare  as above and additionally: if the device is bare it can become a spare if there
                  is any array that it is a candidate for based on domains and metadata.

           spare-same-slot
                  as above and additionally if given slot was used by an array that went degraded
                  recently   and  the  device  plugged  in  has  no  metadata  then  it  will  be
                  automatically added to that array (or it's container)

           force-spare
                  as above and the disk will become a spare in remaining cases

       PART-POLICY
              This is similar to POLICY and accepts the same keyword assignments.   It  allows  a
              consistent set of policies to applied to each of the partitions of a device.

              A  PART-POLICY  line should set type=disk and identify the path to one or more disk
              devices.  Each partition on these disks will be treated according  to  the  action=
              setting   from  this  line.   If  a  domain  is  set  in  the line, then the domain
              associated with each patition will be  based  on  the  domain,  but  with  "-partN"
              appended, when N is the partition number for the partition that was found.

       SYSFS  The  SYSFS  line  lists custom values of MD device's sysfs attributes which will be
              stored in sysfs after the array is assembled. Multiple lines are allowed  and  each
              line  has to contain the uuid or the name of the device to which it relates.  Lines
              are applied in reverse order.

           uuid=  hexadecimal identifier of MD device. This has to match the uuid stored  in  the
                  superblock.

           name=  name of the MD device as was given to mdadm when the array was created. It will
                  be ignored if uuid is not empty.

       MONITORDELAY
              The monitordelay line gives a delay in seconds mdadm shall wait before  pooling  md
              arrays  when  mdadm is running in --monitor mode.  -d/--delay command line argument
              takes precedence over the config file.

              If  multiple  MINITORDELAY  lines  are  provided,  only  first  non-zero  value  is
              considered.

FILES

   /etc/mdadm.conf
       The default config file location, used when mdadm is running without --config option.

   /etc/mdadm.conf.d
       The  default  directory  with  config  files.  Used when mdadm is running without --config
       option, after successful reading of the /etc/mdadm.conf default config file. Files in that
       directory are read in lexical order.

   /etc/mdadm/mdadm.conf
       Alternative  config  file  that is read, when mdadm is running without --config option and
       the /etc/mdadm.conf default config file was not opened successfully.

   /etc/mdadm/mdadm.conf.d
       The alternative directory with config files. Used when mdadm is runninng without  --config
       option,  after  reading  the  /etc/mdadm/mdadm.conf alternative config file whether it was
       successful or not. Files in that directory are read in lexical order.

EXAMPLE

       DEVICE /dev/sd[bcdjkl]1
       DEVICE /dev/hda1 /dev/hdb1

       # /dev/md0 is known by its UUID.
       ARRAY /dev/md0 UUID=3aaa0122:29827cfa:5331ad66:ca767371
       # /dev/md1 contains all devices with a minor number of
       #   1 in the superblock.
       ARRAY /dev/md1 superminor=1
       # /dev/md2 is made from precisely these two devices
       ARRAY /dev/md2 devices=/dev/hda1,/dev/hdb1

       # /dev/md4 and /dev/md5 are a spare-group and spares
       #  can be moved between them
       ARRAY /dev/md4 uuid=b23f3c6d:aec43a9f:fd65db85:369432df
                  spare-group=group1
       ARRAY /dev/md5 uuid=19464854:03f71b1b:e0df2edd:246cc977
                  spare-group=group1
       # /dev/md/home is created if need to be a partitionable md array
       # any spare device number is allocated.
       ARRAY /dev/md/home UUID=9187a482:5dde19d9:eea3cc4a:d646ab8b
                  auto=part
       POLICY domain=domain1 metadata=imsm path=pci-0000:00:1f.2-scsi-*
                  action=spare
       POLICY domain=domain1 metadata=imsm path=pci-0000:04:00.0-scsi-[01]*
                  action=include
       # One domain comprising of devices attached to specified paths is defined.
       # Bare device matching first path will be made an imsm spare on hot plug.
       # If more than one array is created on devices belonging to domain1 and
       # one of them becomes degraded, then any imsm spare matching any path for
       # given domain name can be migrated.
       MAILADDR root@mydomain.tld
       PROGRAM /usr/sbin/handle-mdadm-events
       CREATE group=system mode=0640 auto=part-8
       HOMEHOST <system>
       AUTO +1.x homehost -all
       SYSFS name=/dev/md/raid5 group_thread_cnt=4 sync_speed_max=1000000
       SYSFS uuid=bead5eb6:31c17a27:da120ba2:7dfda40d group_thread_cnt=4 sync_speed_max=1000000
       MONITORDELAY 60

SEE ALSO

       mdadm(8), md(4).

                                                                                    MDADM.CONF(5)