noble (5) pcp-htop.5.gz

Provided by: pcp_6.2.0-1.1build4_amd64 bug

NAME

       pcp-htop - pcp-htop configuration file

DESCRIPTION

       pcp-htop  is  a  customizable performance metrics reporting tool.  It has a dynamic architecture, where a
       set of configuration files provide additional, optional meters and columns to extend  the  fixed  set  of
       display options provided by regular htop.

       These  configuration  files  can  be  provided  from both system-wide locations (first /etc/pcp/htop then
       /usr/share/pcp/htop) and  below  the  user's  home  directory  (usually  ~/.config/htop).   Within  these
       locations the meters and columns are scanned for dynamic Meter and Column specifications.

       Meters are displayed in the top part of the pcp-htop window, and columns are displayed in the lower part.
       Meters tend to display system-wide metrics, and Columns display metrics about individual processes.

       The formats are similar but have slightly different requirements.  Both formats follow  the  common  ini-
       style. Blank lines are ignored.  Lines starting with the "#" character are treated as comments.

METERS

       The following is an example configuration for a new Redis meter:

            [redisclient]
            caption = Redis clients
            type = bar
            blocked.metric = redis.blocked_clients
            blocked.color = blue
            blocked.label = blk
            clients.metric = redis.connected_clients
            clients.color = green
            clients.label = conn

       A  configuration  file can contain multiple meter definitions.  Each definition begins with a identifying
       name enclosed by square brackets - redisclient in this example.  The name is used internally within  pcp-
       htop  and  must  be  unique,  must  begin with an alphabetic character, and may subsequently only contain
       alphanumeric characters or the underscore character.  No whitespace or other characters are allowed.

       There are several parameters that define the way the meter will be displayed to the user.

       caption
            This value is displayed on the Setup screen once the meter has been selected.  A  truncated  version
            of  the  caption will also be displayed (followed by a colon) on the primary display while the meter
            is updating.

       description
            This can be used to provide more detail during the meter selection process on the Setup screen,  and
            if  present  it  is displayed in the "Available Meters" column.  If not present, the caption will be
            used for this.  If neither is present, the internal (mandatory) name will be used.

       type This setting allows a preferred default meter type to be specified.  The associated  value  must  be
            one  of bar, text, graph, or led.  If no value is provided for a dynamic meter, the default value of
            text will be used.

       maximum
            A numeric value can also be set to size the meter, such that values  (e.g.  for  a  bar  type  meter
            display) will be scaled within range zero to maximum.

       The  remaining  definition  syntax  describes  the individual metric(s) which will be used to animate the
       meter.  One or more metrics must be specified for each meter and there are several properties  associated
       with  each.   Once  again,  these  metrics must be named (the same rules described above for meters apply
       here) and the following properties can be configured:

       name.metric
            This is the only mandatory field and associates a PCP metric with the  meter.   Values  sampled  for
            each  metric  at  runtime  provide  the  animation  visible  in  the  pcp-htop  display.  The metric
            specification can be either a PCP  metric  name  as  listed  by  pminfo(1)  or  a  "derived"  metric
            expression.   The  format  for  derived  metric expressions is described on the pmRegisterDerived(3)
            manual page.

       name.color
            Setting color to be used when rendering metric values.  Possible values are red, green, blue,  cyan,
            magenta, yellow, gray, darkgray or white.

       name.label
            An  optional, short label to display before the metric value.  The ":" character will be appended to
            the label before the metric value part of the display.

       name.suffix
            An optional, short suffix to display after the metric value.  Commonly used to indicate values as  a
            percentage  using  a  "%" suffix value and to provide the base unit of measurement.  Note that since
            PCP maintains units for metrics, for those metrics that have dimension in "space" (bytes, kilobytes,
            megabytes, etc), a suffix will be automatically appended.

COLUMNS

       The  following  is  an  example  configuration  for  a  new column showing open file descriptors for each
       process:

            [openfds]
            heading = FDS
            caption = FDCOUNT
            description = Open file descriptors
            metric = proc.fd.count
            width = 3

       A configuration file can contain multiple column definitions.  Each definition begins with a  identifying
       name  enclosed  by square brackets - openfds in this example, and the same rules apply as described above
       for meter names.

       Each column must specify a metric.  Optional parameters can also be set.

       metric
            As with meters, the metric value must be either a PCP metric  name  as  listed  by  pminfo(1)  or  a
            derived  metric.   The  metric must have an instance domain (set of values) and that instance domain
            must map to the set of processes with the instance  identifier  being  PIDs  (process  identifiers).
            Typically  this  will  be metrics from the proc or hotproc namespace (pmdaproc(1)), but metrics from
            other domains (pmdabcc(1), pmdabpf(1), etc) that have per-process values are equally applicable.

       width
            Column width to use when displaying values for the metric.  A negative value can be used to  specify
            left  alignment.  An upper column limit of 28 characters is enforced.  The default column width is 5
            characters.

       heading
            The short title that will be displayed at the head of the column - usually  a  short,  cryptic,  all
            uppercase string.

       caption
            A  short identifying word presented to users on the Setup screen under both the Available and Active
            Columns lists.

       description
            Text that assists users to understand the meaning of this column when it is being presented via  the
            Setup screen in the Available Columns list.

SEE ALSO

       pcp-htop(1), pminfo(1), pmcd(1), pmdaproc(1), pmdabcc(1), pmdabpf(1) and pmRegisterDerived(3).

AUTHORS

       htop  was  originally  developed  by  Hisham  Muhammad.   Nowadays  it  is maintained by the community at
       <htop@groups.io>.

       pcp-htop is maintained as a collaboration between the <htop@groups.io> and  <pcp@groups.io>  communities,
       and forms part of the Performance Co-Pilot suite of tools.