Provided by: ovn-common_24.03.2-0ubuntu0.24.04.1_amd64 bug

NAME

       ovn-architecture - Open Virtual Network architecture

DESCRIPTION

       OVN,  the Open Virtual Network, is a system to support logical network abstraction in virtual machine and
       container environments. OVN complements the existing capabilities  of  OVS  to  add  native  support  for
       logical  network  abstractions,  such as logical L2 and L3 overlays and security groups. Services such as
       DHCP are also desirable features. Just like OVS, OVN’s  design  goal  is  to  have  a  production-quality
       implementation that can operate at significant scale.

       A  physical network comprises physical wires, switches, and routers. A virtual network extends a physical
       network into a hypervisor or container platform, bridging VMs or containers into the physical network. An
       OVN  logical  network  is  a  network  implemented  in software that is insulated from physical (and thus
       virtual) networks by tunnels or other encapsulations. This allows IP and other  address  spaces  used  in
       logical  networks  to  overlap  with  those  used on physical networks without causing conflicts. Logical
       network topologies can be arranged without regard for the topologies of the physical  networks  on  which
       they  run.  Thus, VMs that are part of a logical network can migrate from one physical machine to another
       without network disruption. See Logical Networks, below, for more information.

       The encapsulation layer prevents VMs and containers connected to a  logical  network  from  communicating
       with  nodes  on  physical  networks.  For  clustering  VMs and containers, this can be acceptable or even
       desirable, but in many cases VMs and containers do need connectivity to physical networks.  OVN  provides
       multiple forms of gateways for this purpose. See Gateways, below, for more information.

       An OVN deployment consists of several components:

              •      A  Cloud  Management  System  (CMS),  which  is  OVN’s  ultimate  client (via its users and
                     administrators). OVN integration requires installing  a  CMS-specific  plugin  and  related
                     software (see below). OVN initially targets OpenStack as CMS.

                     We  generally  speak  of ``the’’ CMS, but one can imagine scenarios in which multiple CMSes
                     manage different parts of an OVN deployment.

              •      An OVN Database physical or virtual node (or, eventually, cluster) installed in  a  central
                     location.

              •      One or more (usually many) hypervisors. Hypervisors must run Open vSwitch and implement the
                     interface described in Documentation/topics/integration.rst  in  the  Open  vSwitch  source
                     tree. Any hypervisor platform supported by Open vSwitch is acceptable.

              •      Zero  or  more  gateways.  A gateway extends a tunnel-based logical network into a physical
                     network by bidirectionally forwarding packets between tunnels and a physical Ethernet port.
                     This allows non-virtualized machines to participate in logical networks. A gateway may be a
                     physical host, a virtual machine, or  an  ASIC-based  hardware  switch  that  supports  the
                     vtep(5) schema.

                     Hypervisors and gateways are together called transport node or chassis.

       The  diagram  below  shows how the major components of OVN and related software interact. Starting at the
       top of the diagram, we have:

              •      The Cloud Management System, as defined above.

              •      The OVN/CMS Plugin is the component of the CMS that interfaces to OVN. In  OpenStack,  this
                     is  a Neutron plugin. The plugin’s main purpose is to translate the CMS’s notion of logical
                     network configuration, stored in the CMS’s configuration database in a CMS-specific format,
                     into an intermediate representation understood by OVN.

                     This  component is necessarily CMS-specific, so a new plugin needs to be developed for each
                     CMS that is integrated with OVN. All of the components below this one in  the  diagram  are
                     CMS-independent.

              •      The  OVN  Northbound  Database  receives the intermediate representation of logical network
                     configuration passed down by the OVN/CMS  Plugin.  The  database  schema  is  meant  to  be
                     ``impedance matched’’ with the concepts used in a CMS, so that it directly supports notions
                     of logical switches, routers, ACLs, and so on. See ovn-nb(5) for details.

                     The OVN Northbound Database  has  only  two  clients:  the  OVN/CMS  Plugin  above  it  and
                     ovn-northd below it.

              •      ovn-northd(8)  connects  to  the  OVN  Northbound  Database above it and the OVN Southbound
                     Database below it. It translates the logical network configuration in terms of conventional
                     network  concepts,  taken  from the OVN Northbound Database, into logical datapath flows in
                     the OVN Southbound Database below it.

              •      The OVN Southbound Database is the center of the  system.  Its  clients  are  ovn-northd(8)
                     above it and ovn-controller(8) on every transport node below it.

                     The OVN Southbound Database contains three kinds of data: Physical Network (PN) tables that
                     specify how to reach hypervisor and other nodes, Logical Network (LN) tables that  describe
                     the  logical  network  in terms of ``logical datapath flows,’’ and Binding tables that link
                     logical network components’ locations to the physical network. The hypervisors populate the
                     PN and Port_Binding tables, whereas ovn-northd(8) populates the LN tables.

                     OVN  Southbound  Database  performance  must scale with the number of transport nodes. This
                     will likely require some work on ovsdb-server(1) as we  encounter  bottlenecks.  Clustering
                     for availability may be needed.

       The remaining components are replicated onto each hypervisor:

              •      ovn-controller(8)  is  OVN’s  agent on each hypervisor and software gateway. Northbound, it
                     connects to the OVN Southbound Database to learn about OVN configuration and status and  to
                     populate the PN table and the Chassis column in Binding table with the hypervisor’s status.
                     Southbound, it connects to ovs-vswitchd(8) as an  OpenFlow  controller,  for  control  over
                     network  traffic,  and to the local ovsdb-server(1) to allow it to monitor and control Open
                     vSwitch configuration.

              •      ovs-vswitchd(8) and ovsdb-server(1) are conventional components of Open vSwitch.

                                         CMS
                                          |
                                          |
                              +-----------|-----------+
                              |           |           |
                              |     OVN/CMS Plugin    |
                              |           |           |
                              |           |           |
                              |   OVN Northbound DB   |
                              |           |           |
                              |           |           |
                              |       ovn-northd      |
                              |           |           |
                              +-----------|-----------+
                                          |
                                          |
                                +-------------------+
                                | OVN Southbound DB |
                                +-------------------+
                                          |
                                          |
                       +------------------+------------------+
                       |                  |                  |
         HV 1          |                  |    HV n          |
       +---------------|---------------+  .  +---------------|---------------+
       |               |               |  .  |               |               |
       |        ovn-controller         |  .  |        ovn-controller         |
       |         |          |          |  .  |         |          |          |
       |         |          |          |     |         |          |          |
       |  ovs-vswitchd   ovsdb-server  |     |  ovs-vswitchd   ovsdb-server  |
       |                               |     |                               |
       +-------------------------------+     +-------------------------------+

   Information Flow in OVN
       Configuration data in OVN flows from north to south. The CMS, through  its  OVN/CMS  plugin,  passes  the
       logical network configuration to ovn-northd via the northbound database. In turn, ovn-northd compiles the
       configuration into a lower-level form and passes it to all of the chassis via the southbound database.

       Status information in OVN flows from south to north. OVN currently provides only a few  forms  of  status
       information.  First, ovn-northd populates the up column in the northbound Logical_Switch_Port table: if a
       logical port’s chassis column in the southbound Port_Binding table is  nonempty,  it  sets  up  to  true,
       otherwise to false. This allows the CMS to detect when a VM’s networking has come up.

       Second,  OVN  provides  feedback to the CMS on the realization of its configuration, that is, whether the
       configuration provided by the CMS has taken effect. This feature requires the CMS  to  participate  in  a
       sequence number protocol, which works the following way:

              1.  When  the  CMS  updates  the  configuration  in  the  northbound database, as part of the same
                  transaction, it increments the value of the nb_cfg column in the  NB_Global  table.  (This  is
                  only necessary if the CMS wants to know when the configuration has been realized.)

              2.  When  ovn-northd  updates  the southbound database based on a given snapshot of the northbound
                  database, it copies nb_cfg from northbound NB_Global into the  southbound  database  SB_Global
                  table,  as  part  of  the  same  transaction. (Thus, an observer monitoring both databases can
                  determine when the southbound database is caught up with the northbound.)

              3.  After ovn-northd receives confirmation from the southbound database server  that  its  changes
                  have committed, it updates sb_cfg in the northbound NB_Global table to the nb_cfg version that
                  was pushed down. (Thus, the CMS or another observer can determine when the southbound database
                  is caught up without a connection to the southbound database.)

              4.  The  ovn-controller process on each chassis receives the updated southbound database, with the
                  updated nb_cfg. This process in turn updates the physical flows  installed  in  the  chassis’s
                  Open  vSwitch  instances.  When  it  receives confirmation from Open vSwitch that the physical
                  flows have been updated, it updates nb_cfg  in  its  own  Chassis  record  in  the  southbound
                  database.

              5.  ovn-northd  monitors  the  nb_cfg  column  in  all  of  the  Chassis records in the southbound
                  database. It keeps track of the minimum value among all the records and  copies  it  into  the
                  hv_cfg  column  in  the  northbound  NB_Global  table.  (Thus, the CMS or another observer can
                  determine when all of the hypervisors have caught up to the northbound configuration.)

   Chassis Setup
       Each chassis in an OVN deployment must be configured with an Open vSwitch bridge dedicated for OVN’s use,
       called  the  integration  bridge.  System  startup  scripts  may  create  this  bridge  prior to starting
       ovn-controller if desired. If this bridge does not exist when ovn-controller starts, it will  be  created
       automatically  with  the  default  configuration  suggested  below.  The  ports on the integration bridge
       include:

              •      On any chassis, tunnel ports that  OVN  uses  to  maintain  logical  network  connectivity.
                     ovn-controller adds, updates, and removes these tunnel ports.

              •      On  a  hypervisor,  any  VIFs  that  are  to be attached to logical networks. For instances
                     connected through software emulated ports such as TUN/TAP or  VETH  pairs,  the  hypervisor
                     itself  will normally create ports and plug them into the integration bridge. For instances
                     connected  through  representor  ports,  typically  used   with   hardware   offload,   the
                     ovn-controller may on CMS direction consult a VIF plug provider for representor port lookup
                     and    plug    them    into     the     integration     bridge     (please     refer     to
                     Documentation/topics/vif-plug-providers/vif-plug-providers.rst
                      for    more    information).    In    both    cases    the    conventions   described   in
                     Documentation/topics/integration.rst in the Open vSwitch source tree is followed to  ensure
                     mapping  between  OVN logical port and VIF. (This is pre-existing integration work that has
                     already been done on hypervisors that support OVS.)

              •      On a gateway, the physical port used  for  logical  network  connectivity.  System  startup
                     scripts  add  this port to the bridge prior to starting ovn-controller. This can be a patch
                     port to another bridge, instead of a physical port, in more sophisticated setups.

       Other ports should not be attached to the integration bridge. In particular, physical ports  attached  to
       the underlay network (as opposed to gateway ports, which are physical ports attached to logical networks)
       must not be attached to the integration bridge. Underlay physical ports should instead be attached  to  a
       separate Open vSwitch bridge (they need not be attached to any bridge at all, in fact).

       The  integration  bridge should be configured as described below. The effect of each of these settings is
       documented in ovs-vswitchd.conf.db(5):

              fail-mode=secure
                     Avoids switching packets between isolated logical networks before ovn-controller starts up.
                     See Controller Failure Settings in ovs-vsctl(8) for more information.

              other-config:disable-in-band=true
                     Suppresses  in-band  control flows for the integration bridge. It would be unusual for such
                     flows to show up anyway, because OVN uses a local controller (over a  Unix  domain  socket)
                     instead  of  a remote controller. It’s possible, however, for some other bridge in the same
                     system to have an in-band remote controller, and in that case  this  suppresses  the  flows
                     that  in-band  control  would  ordinarily  set  up.  Refer  to  the  documentation for more
                     information.

       The customary name for the integration bridge is br-int, but another name may be used.

   Logical Networks
       Logical network concepts in OVN include logical switches and logical  routers,  the  logical  version  of
       Ethernet switches and IP routers, respectively. Like their physical cousins, logical switches and routers
       can be connected into sophisticated topologies.  Logical  switches  and  routers  are  ordinarily  purely
       logical  entities,  that  is,  they  are  not  associated or bound to any physical location, and they are
       implemented in a distributed manner at each hypervisor that participates in OVN.

       Logical switch ports (LSPs) are points of connectivity into and out of logical switches. There  are  many
       kinds  of logical switch ports. The most ordinary kind represent VIFs, that is, attachment points for VMs
       or containers. A VIF logical port is associated with the physical location of its VM, which might  change
       as  the  VM  migrates. (A VIF logical port can be associated with a VM that is powered down or suspended.
       Such a logical port has no location and no connectivity.)

       Logical router ports (LRPs) are points of connectivity into and out of logical routers. A LRP connects  a
       logical  router  either to a logical switch or to another logical router. Logical routers only connect to
       VMs, containers, and other network nodes indirectly, through logical switches.

       Logical switches and logical routers have distinct kinds of  logical  ports,  so  properly  speaking  one
       should usually talk about logical switch ports or logical router ports. However, an unqualified ``logical
       port’’ usually refers to a logical switch port.

       When a VM sends a packet to a VIF logical switch port, the Open vSwitch flow tables simulate the packet’s
       journey  through  that  logical  switch  and any other logical routers and logical switches that it might
       encounter. This happens without transmitting the packet across  any  physical  medium:  the  flow  tables
       implement  all  of the switching and routing decisions and behavior. If the flow tables ultimately decide
       to output the packet at a logical port attached to another  hypervisor  (or  another  kind  of  transport
       node),  then  that  is the time at which the packet is encapsulated for physical network transmission and
       sent.

     Logical Switch Port Types

       OVN supports a number of kinds of logical switch ports. VIF ports that  connect  to  VMs  or  containers,
       described  above,  are  the  most ordinary kind of LSP. In the OVN northbound database, VIF ports have an
       empty string for their type. This section describes some of the additional port types.

       A router logical switch port connects a logical switch to a logical router, designating a particular  LRP
       as its peer.

       A localnet logical switch port bridges a logical switch to a physical VLAN. A logical switch may have one
       or more localnet ports. Such a logical switch is used in two scenarios:

              •      With one or more router logical switch ports, to attach L3 gateway routers and  distributed
                     gateways to a physical network.

              •      With  one  or  more  VIF  logical  switch  ports, to attach VMs or containers directly to a
                     physical network. In this case, the logical switch is  not  really  logical,  since  it  is
                     bridged  to  the  physical network rather than insulated from it, and therefore cannot have
                     independent but overlapping IP address namespaces, etc.  A  deployment  might  nevertheless
                     choose such a configuration to take advantage of the OVN control plane and features such as
                     port security and ACLs.

       When a logical switch contains multiple localnet ports, the following is assumed.

              •      Each chassis has a bridge mapping for one of the localnet physical networks only.

              •      To facilitate interconnectivity between VIF  ports  of  the  switch  that  are  located  on
                     different  chassis  with  different physical network connectivity, the fabric implements L3
                     routing between these adjacent physical network segments.

       Note: nothing said above implies that a chassis cannot be plugged to multiple physical networks  as  long
       as they belong to different switches.

       A  localport logical switch port is a special kind of VIF logical switch port. These ports are present in
       every chassis, not bound to any particular one. Traffic to such a port will never be forwarded through  a
       tunnel,  and  traffic  from such a port is expected to be destined only to the same chassis, typically in
       response to a request it received. OpenStack Neutron uses a localport port to serve metadata  to  VMs.  A
       metadata  proxy  process  is attached to this port on every host and all VMs within the same network will
       reach it at the same IP/MAC address without any traffic being sent over a tunnel.  For  further  details,
       see the OpenStack documentation for networking-ovn.

       LSP types vtep and l2gateway are used for gateways. See Gateways, below, for more information.

     Implementation Details

       These concepts are details of how OVN is implemented internally. They might still be of interest to users
       and administrators.

       Logical datapaths are an implementation detail of  logical  networks  in  the  OVN  southbound  database.
       ovn-northd translates each logical switch or router in the northbound database into a logical datapath in
       the southbound database Datapath_Binding table.

       For the most part, ovn-northd also translates each logical switch port in  the  OVN  northbound  database
       into  a record in the southbound database Port_Binding table. The latter table corresponds roughly to the
       northbound Logical_Switch_Port table. It has multiple types of logical port bindings, of which many types
       correspond  directly  to  northbound  LSP  types.  LSP types handled this way include VIF (empty string),
       localnet, localport, vtep, and l2gateway.

       The Port_Binding table has some types of port binding that do not correspond directly to  logical  switch
       port  types.  The common is patch port bindings, known as logical patch ports. These port bindings always
       occur in pairs, and a packet that enters on either side comes  out  on  the  other.  ovn-northd  connects
       logical switches and logical routers together using logical patch ports.

       Port bindings with types vtep, l2gateway, l3gateway, and chassisredirect are used for gateways. These are
       explained in Gateways, below.

   Gateways
       Gateways provide limited connectivity between logical networks and physical ones. They can  also  provide
       connectivity  between  different  OVN  deployments. This section will focus on the former, and the latter
       will be described in details in section OVN Deployments Interconnection.

       OVN support multiple kinds of gateways.

     VTEP Gateways

       A ``VTEP gateway’’ connects an OVN logical network to a physical (or virtual) switch that implements  the
       OVSDB  VTEP  schema that accompanies Open vSwitch. (The ``VTEP gateway’’ term is a misnomer, since a VTEP
       is just a VXLAN Tunnel Endpoint, but it is a well established name.) See Life Cycle of  a  VTEP  gateway,
       below, for more information.

       The  main  intended  use  case  for VTEP gateways is to attach physical servers to an OVN logical network
       using a physical top-of-rack switch that supports the OVSDB VTEP schema.

     L2 Gateways

       A L2 gateway simply attaches a designated physical L2 segment available on  some  chassis  to  a  logical
       network. The physical network effectively becomes part of the logical network.

       To  set  up  a  L2  gateway,  the CMS adds an l2gateway LSP to an appropriate logical switch, setting LSP
       options to name the chassis on which it should be bound. ovn-northd  copies  this  configuration  into  a
       southbound  Port_Binding record. On the designated chassis, ovn-controller forwards packets appropriately
       to and from the physical segment.

       L2 gateway ports have features in common with localnet ports. However, with a localnet port, the physical
       network  becomes  the  transport  between  hypervisors. With an L2 gateway, packets are still transported
       between hypervisors over tunnels and the l2gateway port is only used for the  packets  that  are  on  the
       physical  network. The application for L2 gateways is similar to that for VTEP gateways, e.g. to add non-
       virtualized machines to a logical network, but L2 gateways do not require special  support  from  top-of-
       rack hardware switches.

     L3 Gateway Routers

       As  described  above  under  Logical Networks, ordinary OVN logical routers are distributed: they are not
       implemented in a single place but rather in every hypervisor chassis. This  is  a  problem  for  stateful
       services such as SNAT and DNAT, which need to be implemented in a centralized manner.

       To  allow  for this kind of functionality, OVN supports L3 gateway routers, which are OVN logical routers
       that are implemented in a designated chassis. Gateway routers  are  typically  used  between  distributed
       logical routers and physical networks. The distributed logical router and the logical switches behind it,
       to which VMs and containers attach, effectively reside on each hypervisor. The distributed router and the
       gateway  router  are  connected  by  another  logical switch, sometimes referred to as a ``join’’ logical
       switch. (OVN logical routers may be connected to one another directly, without an intervening switch, but
       the  OVN  implementation  only  supports  gateway logical routers that are connected to logical switches.
       Using a join logical switch also reduces the number of IP addresses needed on the distributed router.) On
       the other side, the gateway router connects to another logical switch that has a localnet port connecting
       to the physical network.

       The following diagram shows a typical situation. One or more logical switches LS1, ...,  LSn  connect  to
       distributed  logical  router  LR1,  which  in turn connects through LSjoin to gateway logical router GLR,
       which also connects to logical switch LSlocal, which includes a localnet port to attach to  the  physical
       network.

                                       LSlocal
                                          |
                                         GLR
                                          |
                                       LSjoin
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       To configure an L3 gateway router, the CMS sets options:chassis in the router’s northbound Logical_Router
       to the chassis’s name. In response, ovn-northd uses a special l3gateway port binding (instead of a  patch
       binding)  in  the  southbound  database  to  connect  the  logical  router  to  its  neighbors.  In turn,
       ovn-controller tunnels packets to this port binding to the designated  L3  gateway  chassis,  instead  of
       processing them locally.

       DNAT  and  SNAT rules may be associated with a gateway router, which provides a central location that can
       handle one-to-many SNAT (aka IP masquerading). Distributed gateway ports, described below,  also  support
       NAT.

     Distributed Gateway Ports

       A  distributed  gateway  port  is  a  logical  router  port that is specially configured to designate one
       distinguished chassis, called the gateway chassis, for centralized processing. A distributed gateway port
       should  connect  to a logical switch that has an LSP that connects externally, that is, either a localnet
       LSP or a connection to another  OVN  deployment  (see  OVN  Deployments  Interconnection).  Packets  that
       traverse  the  distributed gateway port are processed without involving the gateway chassis when they can
       be, but when needed they do take an extra hop through it.

       The following diagram illustrates the use of a distributed gateway port. A  number  of  logical  switches
       LS1,  ...,  LSn connect to distributed logical router LR1, which in turn connects through the distributed
       gateway port to logical switch LSlocal that includes a localnet port to attach to the physical network.

                                       LSlocal
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       ovn-northd creates two southbound Port_Binding records to represent a distributed gateway  port,  instead
       of  the  usual  one.  One  of  these is a patch port binding named for the LRP, which is used for as much
       traffic as it can. The other one is  a  port  binding  with  type  chassisredirect,  named  cr-port.  The
       chassisredirect  port  binding  has  one  specialized  job: when a packet is output to it, the flow table
       causes it to be tunneled to the gateway chassis, at which point it is automatically output to  the  patch
       port  binding.  Thus, the flow table can output to this port binding in cases where a particular task has
       to happen on the gateway chassis. The chassisredirect port binding is not otherwise used (for example, it
       never receives packets).

       The  CMS  may  configure distributed gateway ports three different ways. See Distributed Gateway Ports in
       the documentation for Logical_Router_Port in ovn-nb(5) for details.

       Distributed gateway ports support high availability. When more than one chassis is  specified,  OVN  only
       uses  one  at a time as the gateway chassis. OVN uses BFD to monitor gateway connectivity, preferring the
       highest-priority gateway that is online.

       A logical router can  have  multiple  distributed  gateway  ports,  each  connecting  different  external
       networks.  Load balancing is not yet supported for logical routers with more than one distributed gateway
       port configured.

       Physical VLAN MTU Issues

       Consider the preceding diagram again:

                                       LSlocal
                                          |
                                         LR1
                                          |
                                     +----+----+
                                     |    |    |
                                    LS1  ...  LSn

       Suppose that each logical switch LS1, ..., LSn is bridged to a physical VLAN-tagged network attached to a
       localnet  port  on  LSlocal,  over  a  distributed gateway port on LR1. If a packet originating on LSi is
       destined to the external network, OVN sends it to the gateway chassis over a tunnel.  There,  the  packet
       traverses  LR1’s  logical  router  pipeline,  possibly undergoes NAT, and eventually ends up at LSlocal’s
       localnet port. If all of the physical links in the network have the same MTU, then the  packet’s  transit
       across  a tunnel causes an MTU problem: tunnel overhead prevents a packet that uses the full physical MTU
       from crossing the tunnel to the gateway chassis (without fragmentation).

       OVN offers two solutions to this problem, the reside-on-redirect-chassis and redirect-type options.  Both
       solutions  require  each logical switch LS1, ..., LSn to include a localnet logical switch port LN1, ...,
       LNn respectively, that is present on each chassis. Both cause packets to be sent over the localnet  ports
       instead  of  tunnels.  They  differ  in  which  packets-some or all-are sent this way. The most prominent
       tradeoff between these options is  that  reside-on-redirect-chassis  is  easier  to  configure  and  that
       redirect-type performs better for east-west traffic.

       The first solution is the reside-on-redirect-chassis option for logical router ports. Setting this option
       on a LRP from (e.g.) LS1 to LR1 disables forwarding from LS1 to LR1 except on  the  gateway  chassis.  On
       chassis  other  than the gateway chassis, this single change means that packets that would otherwise have
       been forwarded to LR1 are instead forwarded to LN1. The instance of  LN1  on  the  gateway  chassis  then
       receives  the  packet  and  forwards  it  to  LR1.  The packet traverses the LR1 logical router pipeline,
       possibly undergoes NAT, and eventually ends up at LSlocal’s localnet port. The packet never  traverses  a
       tunnel, avoiding the MTU issue.

       This  option  has  the  further  consequence of centralizing ``distributed’’ logical router LR1, since no
       packets are forwarded from LS1 to LR1 on any chassis other than the gateway chassis. Therefore, east-west
       traffic  passes  through  the gateway chassis, not just north-south. (The naive ``fix’’ of allowing east-
       west traffic to flow directly between chassis over LN1 does not work because routing  sets  the  Ethernet
       source  address to LR1’s source address. Seeing this single Ethernet source address originate from all of
       the chassis will confuse the physical switch.)

       Do not set the reside-on-redirect-chassis option on a distributed gateway port. In the diagram above,  it
       would be set on the LRPs connecting LS1, ..., LSn to LR1.

       The  second  solution  is  the redirect-type option for distributed gateway ports. Setting this option to
       bridged causes packets that are redirected to the gateway chassis to go over the localnet  ports  instead
       of  being  tunneled.  This  option  does  not change how OVN treats packets not redirected to the gateway
       chassis.

       The redirect-type option requires the administrator or the CMS to configure  each  participating  chassis
       with  a  unique  Ethernet  address for the logical router by setting ovn-chassis-mac-mappings in the Open
       vSwitch  database,  for  use  by  ovn-controller.  This  makes  it  more  difficult  to  configure   than
       reside-on-redirect-chassis.

       Set the redirect-type option on a distributed gateway port.

       Using Distributed Gateway Ports For Scalability

       Although  the  primary goal of distributed gateway ports is to provide connectivity to external networks,
       there is a special use case for scalability.

       In some deployments, such as the ones using ovn-kubernetes, logical  switches  are  bound  to  individual
       chassises,  and  are  connected  by  a distributed logical router. In such deployments, the chassis level
       logical switches are centralized on the chassis instead of distributed, which means the ovn-controller on
       each  chassis  doesn’t  need  to process flows and ports of logical switches on other chassises. However,
       without any specific hint, ovn-controller would still process all the logical switches  as  if  they  are
       fully  distributed.  In this case, distributed gateway port can be very useful. The chassis level logical
       switches can be connected to the distributed router using  distributed  gateway  ports,  by  setting  the
       gateway  chassis (or HA chassis groups with only a single chassis in it) to the chassis that each logical
       switch is bound to. ovn-controller would then skip processing the  logical  switches  on  all  the  other
       chassises, largely improving the scalability, especially when there are a big number of chassises.

   Life Cycle of a VIF
       Tables and their schemas presented in isolation are difficult to understand. Here’s an example.

       A  VIF  on  a  hypervisor  is  a virtual network interface attached either to a VM or a container running
       directly on that hypervisor (This is different from the interface of a container running inside a VM).

       The steps in this example refer often to details of the OVN and OVN Northbound database  schemas.  Please
       see ovn-sb(5) and ovn-nb(5), respectively, for the full story on these databases.

              1.  A  VIF’s  life  cycle  begins  when  a  CMS administrator creates a new VIF using the CMS user
                  interface or API and adds it to a switch (one implemented by OVN as a logical switch). The CMS
                  updates  its own configuration. This includes associating unique, persistent identifier vif-id
                  and Ethernet address mac with the VIF.

              2.  The CMS plugin updates the OVN Northbound database to include the new VIF, by adding a row  to
                  the  Logical_Switch_Port  table.  In the new row, name is vif-id, mac is mac, switch points to
                  the  OVN  logical  switch’s  Logical_Switch  record,  and  other   columns   are   initialized
                  appropriately.

              3.  ovn-northd  receives  the  OVN Northbound database update. In turn, it makes the corresponding
                  updates to the OVN Southbound  database,  by  adding  rows  to  the  OVN  Southbound  database
                  Logical_Flow table to reflect the new port, e.g. add a flow to recognize that packets destined
                  to the new port’s MAC address should be delivered to it, and update  the  flow  that  delivers
                  broadcast  and  multicast  packets  to  include  the new port. It also creates a record in the
                  Binding table and populates all its columns except the column that identifies the chassis.

              4.  On every hypervisor, ovn-controller receives the Logical_Flow table  updates  that  ovn-northd
                  made  in the previous step. As long as the VM that owns the VIF is powered off, ovn-controller
                  cannot do much; it cannot, for example, arrange to send packets to or receive packets from the
                  VIF, because the VIF does not actually exist anywhere.

              5.  Eventually,  a  user  powers  on  the  VM that owns the VIF. On the hypervisor where the VM is
                  powered  on,  the  integration  between  the  hypervisor  and  Open  vSwitch   (described   in
                  Documentation/topics/integration.rst  in the Open vSwitch source tree) adds the VIF to the OVN
                  integration bridge and stores vif-id in external_ids:iface-id to indicate that  the  interface
                  is  an  instantiation  of  the new VIF. (None of this code is new in OVN; this is pre-existing
                  integration work that has already been done on hypervisors that support OVS.)

              6.  On the hypervisor where the VM is powered on, ovn-controller notices external_ids:iface-id  in
                  the  new  Interface.  In  response,  in  the OVN Southbound DB, it updates the Binding table’s
                  chassis column for the row that links the logical port  from  external_ids:  iface-id  to  the
                  hypervisor.  Afterward,  ovn-controller updates the local hypervisor’s OpenFlow tables so that
                  packets to and from the VIF are properly handled.

              7.  Some CMS systems, including OpenStack, fully start a VM only when its networking is ready.  To
                  support  this,  ovn-northd notices the chassis column updated for the row in Binding table and
                  pushes  this  upward  by  updating  the  up  column   in   the   OVN   Northbound   database’s
                  Logical_Switch_Port  table  to  indicate  that  the  VIF  is  now up. The CMS, if it uses this
                  feature, can then react by allowing the VM’s execution to proceed.

              8.  On every hypervisor but the one where the VIF resides, ovn-controller notices  the  completely
                  populated  row in the Binding table. This provides ovn-controller the physical location of the
                  logical port, so each instance updates the OpenFlow tables of its  switch  (based  on  logical
                  datapath  flows  in  the OVN DB Logical_Flow table) so that packets to and from the VIF can be
                  properly handled via tunnels.

              9.  Eventually, a user powers off the VM that owns the VIF. On the hypervisor  where  the  VM  was
                  powered off, the VIF is deleted from the OVN integration bridge.

              10. On  the  hypervisor  where  the  VM  was  powered off, ovn-controller notices that the VIF was
                  deleted. In response, it removes the Chassis column content  in  the  Binding  table  for  the
                  logical port.

              11. On  every  hypervisor,  ovn-controller notices the empty Chassis column in the Binding table’s
                  row for the logical port. This means that ovn-controller no longer knows the physical location
                  of the logical port, so each instance updates its OpenFlow table to reflect that.

              12. Eventually,  when  the  VIF (or its entire VM) is no longer needed by anyone, an administrator
                  deletes the VIF using the CMS user interface or API. The CMS updates its own configuration.

              13. The CMS plugin removes the VIF from the OVN Northbound database, by deleting its  row  in  the
                  Logical_Switch_Port table.

              14. ovn-northd  receives the OVN Northbound update and in turn updates the OVN Southbound database
                  accordingly, by removing or updating the rows from the OVN  Southbound  database  Logical_Flow
                  table and Binding table that were related to the now-destroyed VIF.

              15. On  every  hypervisor,  ovn-controller receives the Logical_Flow table updates that ovn-northd
                  made in the previous step. ovn-controller updates  OpenFlow  tables  to  reflect  the  update,
                  although there may not be much to do, since the VIF had already become unreachable when it was
                  removed from the Binding table in a previous step.

   Life Cycle of a Container Interface Inside a VM
       OVN provides virtual network abstractions  by  converting  information  written  in  OVN_NB  database  to
       OpenFlow  flows  in  each hypervisor. Secure virtual networking for multi-tenants can only be provided if
       OVN controller is the only entity  that  can  modify  flows  in  Open  vSwitch.  When  the  Open  vSwitch
       integration  bridge  resides  in  the  hypervisor,  it is a fair assumption to make that tenant workloads
       running inside VMs cannot make any changes to Open vSwitch flows.

       If the infrastructure provider trusts the applications inside the containers not to break out and  modify
       the  Open vSwitch flows, then containers can be run in hypervisors. This is also the case when containers
       are run inside the VMs and Open vSwitch integration bridge with flows added by OVN controller resides  in
       the  same  VM.  For  both  the  above cases, the workflow is the same as explained with an example in the
       previous section ("Life Cycle of a VIF").

       This section talks about the life cycle of a container interface (CIF) when containers are created in the
       VMs  and  the  Open  vSwitch  integration  bridge  resides inside the hypervisor. In this case, even if a
       container application breaks out, other tenants are not affected because the  containers  running  inside
       the VMs cannot modify the flows in the Open vSwitch integration bridge.

       When  multiple  containers  are  created  inside  a VM, there are multiple CIFs associated with them. The
       network traffic associated with these CIFs need to reach the Open vSwitch integration bridge  running  in
       the  hypervisor  for  OVN to support virtual network abstractions. OVN should also be able to distinguish
       network traffic coming from different CIFs. There are two ways to distinguish network traffic of CIFs.

       One way is to provide one VIF for every CIF (1:1 model). This means that there could be a lot of  network
       devices  in  the hypervisor. This would slow down OVS because of all the additional CPU cycles needed for
       the management of all the VIFs. It would also mean that the entity creating the containers in a VM should
       also be able to create the corresponding VIFs in the hypervisor.

       The  second  way  is  to provide a single VIF for all the CIFs (1:many model). OVN could then distinguish
       network traffic coming from different CIFs via a tag written in every packet. OVN uses this mechanism and
       uses VLAN as the tagging mechanism.

              1.  A  CIF’s  life cycle begins when a container is spawned inside a VM by the either the same CMS
                  that created the VM or a tenant that owns that VM or even  a  container  Orchestration  System
                  that  is  different than the CMS that initially created the VM. Whoever the entity is, it will
                  need to know the vif-id that is associated with the network interface of the VM through  which
                  the  container  interface’s network traffic is expected to go through. The entity that creates
                  the container interface will also need to choose an unused VLAN inside that VM.

              2.  The container spawning entity (either directly or through the CMS that manages the  underlying
                  infrastructure) updates the OVN Northbound database to include the new CIF, by adding a row to
                  the Logical_Switch_Port table. In the new row, name is any unique identifier,  parent_name  is
                  the vif-id of the VM through which the CIF’s network traffic is expected to go through and the
                  tag is the VLAN tag that identifies the network traffic of that CIF.

              3.  ovn-northd receives the OVN Northbound database update. In turn, it  makes  the  corresponding
                  updates  to  the  OVN  Southbound  database,  by  adding rows to the OVN Southbound database’s
                  Logical_Flow table to reflect the new port and also by creating a new row in the Binding table
                  and populating all its columns except the column that identifies the chassis.

              4.  On every hypervisor, ovn-controller subscribes to the changes in the Binding table. When a new
                  row is created by ovn-northd that includes a value in parent_port column of Binding table, the
                  ovn-controller in the hypervisor whose OVN integration bridge has that same value in vif-id in
                  external_ids:iface-id updates the local hypervisor’s OpenFlow tables so that  packets  to  and
                  from  the  VIF  with  the  particular  VLAN tag are properly handled. Afterward it updates the
                  chassis column of the Binding to reflect the physical location.

              5.  One can only start the application inside the container after the underlying network is ready.
                  To  support  this,  ovn-northd notices the updated chassis column in Binding table and updates
                  the up column in the OVN Northbound database’s Logical_Switch_Port table to indicate that  the
                  CIF  is  now  up. The entity responsible to start the container application queries this value
                  and starts the application.

              6.  Eventually the entity that created and started the container, stops it.  The  entity,  through
                  the CMS (or directly) deletes its row in the Logical_Switch_Port table.

              7.  ovn-northd  receives the OVN Northbound update and in turn updates the OVN Southbound database
                  accordingly, by removing or updating the rows from the OVN  Southbound  database  Logical_Flow
                  table that were related to the now-destroyed CIF. It also deletes the row in the Binding table
                  for that CIF.

              8.  On every hypervisor, ovn-controller receives the Logical_Flow table  updates  that  ovn-northd
                  made in the previous step. ovn-controller updates OpenFlow tables to reflect the update.

   Architectural Physical Life Cycle of a Packet
       This section describes how a packet travels from one virtual machine or container to another through OVN.
       This description focuses on the physical treatment of a packet; for a description  of  the  logical  life
       cycle of a packet, please refer to the Logical_Flow table in ovn-sb(5).

       This section mentions several data and metadata fields, for clarity summarized here:

              tunnel key
                     When OVN encapsulates a packet in Geneve or another tunnel, it attaches extra data to it to
                     allow the receiving OVN instance to  process  it  correctly.  This  takes  different  forms
                     depending  on  the  particular  encapsulation,  but in each case we refer to it here as the
                     ``tunnel key.’’ See Tunnel Encapsulations, below, for details.

              logical datapath field
                     A field that denotes the logical datapath through which a packet is  being  processed.  OVN
                     uses  the field that OpenFlow 1.1+ simply (and confusingly) calls ``metadata’’ to store the
                     logical datapath. (This field is passed across tunnels as part of the tunnel key.)

              logical input port field
                     A field that denotes the logical port from which the packet entered the  logical  datapath.
                     OVN stores this in Open vSwitch extension register number 14.

                     Geneve and STT tunnels pass this field as part of the tunnel key. Ramp switch VXLAN tunnels
                     do not explicitly carry a logical input port, but since they are used to  communicate  with
                     gateways that from OVN’s perspective consist of only a single logical port, so that OVN can
                     set the logical input port field to this one on ingress to the OVN logical pipeline. As for
                     regular  VXLAN  tunnels,  they  don’t  carry  input port field at all. This puts additional
                     limitations on cluster capabilities that are described in Tunnel Encapsulations section.

              logical output port field
                     A field that denotes the logical  port  from  which  the  packet  will  leave  the  logical
                     datapath.  This  is  initialized to 0 at the beginning of the logical ingress pipeline. OVN
                     stores this in Open vSwitch extension register number 15.

                     Geneve, STT and regular VXLAN tunnels pass this field as  part  of  the  tunnel  key.  Ramp
                     switch  VXLAN  tunnels do not transmit the logical output port field, and since they do not
                     carry a logical output port field in the tunnel key, when a packet is  received  from  ramp
                     switch VXLAN tunnel by an OVN hypervisor, the packet is resubmitted to table 8 to determine
                     the output port(s); when the packet reaches table 39,  these  packets  are  resubmitted  to
                     table  40  for  local  delivery by checking a MLF_RCV_FROM_RAMP flag, which is set when the
                     packet arrives from a ramp tunnel.

              conntrack zone field for logical ports
                     A field that denotes the connection tracking zone for logical ports.  The  value  only  has
                     local  significance  and is not meaningful between chassis. This is initialized to 0 at the
                     beginning of the logical ingress pipeline. OVN stores this in the lower 16 bits of the Open
                     vSwitch extension register number 13.

              conntrack zone fields for routers
                     Fields  that denote the connection tracking zones for routers. These values only have local
                     significance and are not meaningful between chassis. OVN stores the  zone  information  for
                     north  to  south traffic (for DNATting or ECMP symmetric replies) in Open vSwitch extension
                     register number 11 and zone information for south to north traffic (for  SNATing)  in  Open
                     vSwitch extension register number 12.

              Encap ID for logical ports
                     A  field  that  records  an  ID  that  indicates which encapsulation IP should be used when
                     sending packets to a remote chassis, according to the original input logical port. This  is
                     useful  when  there  are multiple IPs available for encapsulation. The value only has local
                     significance and is not meaningful between  chassis.  This  is  initialized  to  0  at  the
                     beginning  of  the  logical  ingress pipeline. OVN stores this in the higher 16 bits of the
                     Open vSwitch extension register number 13.

              logical flow flags
                     The logical flags are intended to handle keeping context between tables in order to  decide
                     which rules in subsequent tables are matched. These values only have local significance and
                     are not meaningful between chassis. OVN stores the logical flags in Open vSwitch  extension
                     register number 10.

              VLAN ID
                     The VLAN ID is used as an interface between OVN and containers nested inside a VM (see Life
                     Cycle of a container interface inside a VM, above, for more information).

       Initially, a VM or container on the ingress hypervisor sends a packet on  a  port  attached  to  the  OVN
       integration bridge. Then:

              1.  OpenFlow  table  0  performs  physical-to-logical translation. It matches the packet’s ingress
                  port. Its actions annotate the packet with logical metadata, by setting the  logical  datapath
                  field  to  identify  the  logical datapath that the packet is traversing and the logical input
                  port field to identify the ingress port. Then it resubmits to table 8  to  enter  the  logical
                  ingress pipeline.

                  Packets that originate from a container nested within a VM are treated in a slightly different
                  way. The originating container can be distinguished based on the VIF-specific VLAN ID, so  the
                  physical-to-logical  translation flows additionally match on VLAN ID and the actions strip the
                  VLAN header. Following this step, OVN treats packets  from  containers  just  like  any  other
                  packets.

                  Table  0  also  processes  packets  that arrive from other chassis. It distinguishes them from
                  other packets by ingress port, which is a tunnel.  As  with  packets  just  entering  the  OVN
                  pipeline,  the actions annotate these packets with logical datapath metadata. For tunnel types
                  that support it, they are also annotated with logical ingress port metadata. In addition,  the
                  actions  set the logical output port field, which is available because in OVN tunneling occurs
                  after the logical output port is known. These pieces of  information  are  obtained  from  the
                  tunnel  encapsulation  metadata  (see  Tunnel  Encapsulations  for encoding details). Then the
                  actions resubmit to table 38 to enter the logical egress pipeline.

              2.  OpenFlow tables 8 through 31 execute the logical ingress pipeline from the Logical_Flow  table
                  in  the  OVN  Southbound  database.  These  tables  are expressed entirely in terms of logical
                  concepts like logical ports and logical datapaths. A big part of ovn-controller’s  job  is  to
                  translate  them  into  equivalent  OpenFlow  (in  particular  it translates the table numbers:
                  Logical_Flow tables 0 through 23 become OpenFlow tables 8 through 31).

                  Each logical flow maps to one or more OpenFlow flows. An actual packet ordinarily matches only
                  one of these, although in some cases it can match more than one of these flows (which is not a
                  problem because all of them have the same actions). ovn-controller uses the first 32  bits  of
                  the logical flow’s UUID as the cookie for its OpenFlow flow or flows. (This is not necessarily
                  unique, since the first 32 bits of a logical flow’s UUID is not necessarily unique.)

                  Some logical  flows  can  map  to  the  Open  vSwitch  ``conjunctive  match’’  extension  (see
                  ovs-fields(7)).  Flows with a conjunction action use an OpenFlow cookie of 0, because they can
                  correspond to multiple logical flows. The OpenFlow flow for a  conjunctive  match  includes  a
                  match on conj_id.

                  Some  logical  flows  may  not be represented in the OpenFlow tables on a given hypervisor, if
                  they could not be used on that hypervisor. For example, if no VIF in a logical switch  resides
                  on  a  given  hypervisor, and the logical switch is not otherwise reachable on that hypervisor
                  (e.g. over a series of hops through logical switches and routers starting from a  VIF  on  the
                  hypervisor), then the logical flow may not be represented there.

                  Most  OVN  actions have fairly obvious implementations in OpenFlow (with OVS extensions), e.g.
                  next; is implemented as resubmit, field = constant; as set_field. A few are  worth  describing
                  in more detail:

                  output:
                         Implemented  by resubmitting the packet to table 37. If the pipeline executes more than
                         one output action, then each one is separately resubmitted to table  37.  This  can  be
                         used  to  send  multiple copies of the packet to multiple ports. (If the packet was not
                         modified between the output actions, and some of the copies are destined  to  the  same
                         hypervisor,  then  using  a  logical multicast output port would save bandwidth between
                         hypervisors.)

                  get_arp(P, A);
                  get_nd(P, A);
                       Implemented by storing arguments into OpenFlow fields, then  resubmitting  to  table  66,
                       which ovn-controller populates with flows generated from the MAC_Binding table in the OVN
                       Southbound database. If there is a match in table 66, then its actions  store  the  bound
                       MAC in the Ethernet destination address field.

                       (The  OpenFlow  actions  save  and restore the OpenFlow fields used for the arguments, so
                       that the OVN actions do not have to be aware of this temporary use.)

                  put_arp(P, A, E);
                  put_nd(P, A, E);
                       Implemented by storing the arguments into OpenFlow fields, then outputting  a  packet  to
                       ovn-controller, which updates the MAC_Binding table.

                       (The  OpenFlow  actions  save  and restore the OpenFlow fields used for the arguments, so
                       that the OVN actions do not have to be aware of this temporary use.)

                  R = lookup_arp(P, A, M);
                  R = lookup_nd(P, A, M);
                       Implemented by storing arguments into OpenFlow fields, then  resubmitting  to  table  67,
                       which ovn-controller populates with flows generated from the MAC_Binding table in the OVN
                       Southbound database. If there is a match in table 67, then its actions  set  the  logical
                       flow flag MLF_LOOKUP_MAC.

                       (The  OpenFlow  actions  save  and restore the OpenFlow fields used for the arguments, so
                       that the OVN actions do not have to be aware of this temporary use.)

              3.  OpenFlow tables 37 through 41 implement the output action in  the  logical  ingress  pipeline.
                  Specifically,  table  37  serves  as  an  entry  point to egress pipeline. Table 37 detects IP
                  packets that are too big for a corresponding interface. Table 38 produces ICMPv4 Fragmentation
                  Needed  (or  ICMPv6  Too  Big)  errors  and  deliver them back to the offending port. table 39
                  handles packets to remote hypervisors, table 40 handles packets to the local  hypervisor,  and
                  table  41  checks whether packets whose logical ingress and egress port are the same should be
                  discarded.

                  Logical patch ports are a special case. Logical patch ports do not have  a  physical  location
                  and  effectively  reside  on every hypervisor. Thus, flow table 40, for output to ports on the
                  local hypervisor, naturally implements output to unicast logical  patch  ports  too.  However,
                  applying  the  same  logic  to  a logical patch port that is part of a logical multicast group
                  yields packet duplication, because each  hypervisor  that  contains  a  logical  port  in  the
                  multicast  group will also output the packet to the logical patch port. Thus, multicast groups
                  implement output to logical patch ports in table 39.

                  Each flow in table 39 matches on a logical output port for unicast or multicast logical  ports
                  that  include  a  logical port on a remote hypervisor. Each flow’s actions implement sending a
                  packet to the port it matches. For unicast logical output ports  on  remote  hypervisors,  the
                  actions  set  the  tunnel key to the correct value, then send the packet on the tunnel port to
                  the correct hypervisor. (When the remote hypervisor receives the packet, table  0  there  will
                  recognize it as a tunneled packet and pass it along to table 40.) For multicast logical output
                  ports, the actions send one copy of the packet to each remote hypervisor, in the same  way  as
                  for  unicast  destinations. If a multicast group includes a logical port or ports on the local
                  hypervisor, then its actions also resubmit to table 40. Table 39 also includes:

                  •      A higher-priority rule to match packets received from ramp  switch  tunnels,  based  on
                         flag  MLF_RCV_FROM_RAMP,  and  resubmit  these  packets to table 40 for local delivery.
                         Packets received from ramp switch tunnels reach here  because  of  a  lack  of  logical
                         output  port  field  in the tunnel key and thus these packets needed to be submitted to
                         table 8 to determine the output port.

                  •      A higher-priority rule to match packets received from ports of type localport, based on
                         the  logical  input  port,  and  resubmit these packets to table 40 for local delivery.
                         Ports of type localport exist on every  hypervisor  and  by  definition  their  traffic
                         should never go out through a tunnel.

                  •      A  higher-priority rule to match packets that have the MLF_LOCAL_ONLY logical flow flag
                         set, and whose destination is a multicast address. This flag indicates that the  packet
                         should  not  be  delivered  to  remote  hypervisors,  even if the multicast destination
                         includes ports on remote hypervisors. This flag is  used  when  ovn-controller  is  the
                         originator  of  the multicast packet. Since each ovn-controller instance is originating
                         these packets, the packets only need to be delivered to local ports.

                  •      A fallback flow that resubmits to table 40 if there is no other match.

                  Flows in table 40 resemble those in table 39 but for logical ports that reside locally  rather
                  than  remotely.  For  unicast  logical  output ports on the local hypervisor, the actions just
                  resubmit to table 41. For multicast output ports that include one or more logical ports on the
                  local  hypervisor, for each such logical port P, the actions change the logical output port to
                  P, then resubmit to table 41.

                  A special case is that when a localnet port exists on the datapath, remote port  is  connected
                  by switching to the localnet port. In this case, instead of adding a flow in table 39 to reach
                  the remote port, a flow is added in table 40 to switch the logical  outport  to  the  localnet
                  port,  and  resubmit  to  table  40  as  if  it  were unicasted to a logical port on the local
                  hypervisor.

                  Table 41 matches and drops packets for which the logical input and output ports are  the  same
                  and the MLF_ALLOW_LOOPBACK flag is not set. It also drops MLF_LOCAL_ONLY packets directed to a
                  localnet port. It resubmits other packets to table 42.

              4.  OpenFlow tables 42 through 62 execute the logical egress pipeline from the Logical_Flow  table
                  in  the  OVN  Southbound database. The egress pipeline can perform a final stage of validation
                  before packet delivery. Eventually, it may execute  an  output  action,  which  ovn-controller
                  implements  by resubmitting to table 64. A packet for which the pipeline never executes output
                  is effectively dropped (although it may have  been  transmitted  through  a  tunnel  across  a
                  physical network).

                  The egress pipeline cannot change the logical output port or cause further tunneling.

              5.  Table  64  bypasses  OpenFlow  loopback  when  MLF_ALLOW_LOOPBACK is set. Logical loopback was
                  handled in table 41, but OpenFlow by default also prevents loopback to  the  OpenFlow  ingress
                  port. Thus, when MLF_ALLOW_LOOPBACK is set, OpenFlow table 64 saves the OpenFlow ingress port,
                  sets it to zero, resubmits to  table  65  for  logical-to-physical  transformation,  and  then
                  restores  the  OpenFlow  ingress  port, effectively disabling OpenFlow loopback prevents. When
                  MLF_ALLOW_LOOPBACK is unset, table 64 flow simply resubmits to table 65.

              6.  OpenFlow table 65 performs logical-to-physical  translation,  the  opposite  of  table  0.  It
                  matches  the  packet’s logical egress port. Its actions output the packet to the port attached
                  to the OVN integration bridge that represents that logical port. If the logical egress port is
                  a container nested with a VM, then before sending the packet the actions push on a VLAN header
                  with an appropriate VLAN ID.

   Logical Routers and Logical Patch Ports
       Typically logical routers and logical patch ports do not have a physical location and effectively  reside
       on  every  hypervisor.  This  is  the  case  for  logical patch ports between logical routers and logical
       switches behind those logical routers, to which VMs (and VIFs) attach.

       Consider a packet sent from one virtual machine or container to another VM or container that resides on a
       different  subnet.  The  packet  will  traverse  tables  0  to  65  as  described in the previous section
       Architectural Physical Life Cycle of a Packet, using the logical datapath representing the logical switch
       that the sender is attached to. At table 39, the packet will use the fallback flow that resubmits locally
       to table 40 on the same hypervisor. In this case, all of the processing from table 0 to table  65  occurs
       on the hypervisor where the sender resides.

       When  the  packet  reaches  table  65,  the  logical  egress port is a logical patch port. ovn-controller
       implements output to the logical patch is packet by  cloning  and  resubmitting  directly  to  the  first
       OpenFlow  flow  table in the ingress pipeline, setting the logical ingress port to the peer logical patch
       port, and using the peer logical patch port’s logical datapath (that represents the logical router).

       The packet re-enters the ingress pipeline in order to traverse tables 8 to 65 again, this time using  the
       logical  datapath  representing the logical router. The processing continues as described in the previous
       section Architectural Physical Life Cycle of a Packet. When the packet  reaches  table  65,  the  logical
       egress  port will once again be a logical patch port. In the same manner as described above, this logical
       patch port will cause the packet to be resubmitted to OpenFlow tables  8  to  65,  this  time  using  the
       logical datapath representing the logical switch that the destination VM or container is attached to.

       The packet traverses tables 8 to 65 a third and final time. If the destination VM or container resides on
       a remote hypervisor, then table 39 will send the packet on a tunnel port from the sender’s hypervisor  to
       the  remote  hypervisor.  Finally  table  65  will  output  the  packet directly to the destination VM or
       container.

       The following sections describe two exceptions, where logical routers  and/or  logical  patch  ports  are
       associated with a physical location.

     Gateway Routers

       A  gateway  router  is  a  logical  router that is bound to a physical location. This includes all of the
       logical patch ports of the logical router, as well as all of the peer  logical  patch  ports  on  logical
       switches.  In the OVN Southbound database, the Port_Binding entries for these logical patch ports use the
       type l3gateway rather than patch, in order to distinguish that these logical patch ports are bound  to  a
       chassis.

       When a hypervisor processes a packet on a logical datapath representing a logical switch, and the logical
       egress port is a l3gateway port representing connectivity to a gateway router, the packet  will  match  a
       flow  in table 39 that sends the packet on a tunnel port to the chassis where the gateway router resides.
       This processing in table 39 is done in the same manner as for VIFs.

     Distributed Gateway Ports

       This section provides additional details on distributed gateway ports, outlined earlier.

       The primary design goal of distributed gateway ports is to allow  as  much  traffic  as  possible  to  be
       handled locally on the hypervisor where a VM or container resides. Whenever possible, packets from the VM
       or container to the outside world should be processed completely on that VM’s or container’s  hypervisor,
       eventually  traversing  a  localnet  port instance or a tunnel to the physical network or a different OVN
       deployment. Whenever possible, packets from the outside world to a VM or  container  should  be  directed
       through the physical network directly to the VM’s or container’s hypervisor.

       In order to allow for the distributed processing of packets described in the paragraph above, distributed
       gateway ports need to be logical patch ports that effectively reside on  every  hypervisor,  rather  than
       l3gateway  ports  that  are bound to a particular chassis. However, the flows associated with distributed
       gateway ports often need to be associated with physical locations, for the following reasons:

              •      The physical network that the localnet port is attached to typically uses L2 learning.  Any
                     Ethernet  address  used  over  the  distributed gateway port must be restricted to a single
                     physical location so that upstream L2 learning  is  not  confused.  Traffic  sent  out  the
                     distributed gateway port towards the localnet port with a specific Ethernet address must be
                     sent out one specific instance of the distributed gateway port  on  one  specific  chassis.
                     Traffic  received  from  the localnet port (or from a VIF on the same logical switch as the
                     localnet port) with a specific Ethernet address must be directed to  the  logical  switch’s
                     patch port instance on that specific chassis.

                     Due  to  the  implications  of  L2  learning,  the  Ethernet  address and IP address of the
                     distributed gateway port need to be restricted to a  single  physical  location.  For  this
                     reason,  the  user  must  specify one chassis associated with the distributed gateway port.
                     Note that traffic traversing the distributed gateway port using  other  Ethernet  addresses
                     and IP addresses (e.g. one-to-one NAT) is not restricted to this chassis.

                     Replies  to ARP and ND requests must be restricted to a single physical location, where the
                     Ethernet address in the reply resides. This includes ARP and ND replies for the IP  address
                     of  the  distributed  gateway  port,  which  are  restricted  to  the chassis that the user
                     associated with the distributed gateway port.

              •      In order to support one-to-many SNAT (aka  IP  masquerading),  where  multiple  logical  IP
                     addresses  spread  across  multiple  chassis are mapped to a single external IP address, it
                     will be necessary to handle some of the logical router processing on a specific chassis  in
                     a  centralized  manner.  Since  the  SNAT  external IP address is typically the distributed
                     gateway port IP  address,  and  for  simplicity,  the  same  chassis  associated  with  the
                     distributed gateway port is used.

       The details of flow restrictions to specific chassis are described in the ovn-northd documentation.

       While  most  of  the  physical  location dependent aspects of distributed gateway ports can be handled by
       restricting some flows to specific chassis, one additional mechanism is required. When  a  packet  leaves
       the  ingress  pipeline  and the logical egress port is the distributed gateway port, one of two different
       sets of actions is required at table 39:

              •      If the packet can be handled locally  on  the  sender’s  hypervisor  (e.g.  one-to-one  NAT
                     traffic),  then  the  packet  should just be resubmitted locally to table 40, in the normal
                     manner for distributed logical patch ports.

              •      However, if the packet needs to be handled on the chassis associated with  the  distributed
                     gateway  port  (e.g.  one-to-many SNAT traffic or non-NAT traffic), then table 39 must send
                     the packet on a tunnel port to that chassis.

       In order to trigger the second set of actions, the chassisredirect type of  southbound  Port_Binding  has
       been  added.  Setting the logical egress port to the type chassisredirect logical port is simply a way to
       indicate that although the packet is destined for the distributed gateway port, it needs to be redirected
       to  a  different  chassis.  At  table  39,  packets  with this logical egress port are sent to a specific
       chassis, in the same way that table 39 directs packets whose logical egress port  is  a  VIF  or  a  type
       l3gateway port to different chassis. Once the packet arrives at that chassis, table 40 resets the logical
       egress port to the value representing the distributed gateway port. For each  distributed  gateway  port,
       there  is  one  type chassisredirect port, in addition to the distributed logical patch port representing
       the distributed gateway port.

     High Availability for Distributed Gateway Ports

       OVN allows you to specify a prioritized list of chassis for a distributed gateway port. This is  done  by
       associating multiple Gateway_Chassis rows with a Logical_Router_Port in the OVN_Northbound database.

       When  multiple  chassis  have  been  specified  for  a gateway, all chassis that may send packets to that
       gateway will enable BFD on tunnels to all configured gateway chassis. The current master chassis for  the
       gateway is the highest priority gateway chassis that is currently viewed as active based on BFD status.

       For     more     information     on     L3     gateway     high    availability,    please    refer    to
       http://docs.ovn.org/en/latest/topics/high-availability.html.

     Restrictions of Distributed Gateway Ports

       Distributed gateway ports are used to connect to an external network, which can  be  a  physical  network
       modeled  by  a  logical  switch with a localnet port, and can also be a logical switch that interconnects
       different OVN deployments (see OVN Deployments  Interconnection).  Usually  there  can  be  many  logical
       routers connected to the same external logical switch, as shown in below diagram.

                                     +--LS-EXT-+
                                     |    |    |
                                     |    |    |
                                    LR1  ...  LRn

       In  this  diagram,  there  are  n  logical  routers  connected  to  a  logical switch LS-EXT, each with a
       distributed gateway port, so that traffic sent to external world is redirected  to  the  gateway  chassis
       that is assigned to the distributed gateway port of respective logical router.

       In  the  logical topology, nothing can prevent an user to add a route between the logical routers via the
       connected distributed gateway ports on LS-EXT. However, the route works only if the LS-EXT is a  physical
       network  (modeled  by  a  logical switch with a localnet port). In that case the packet will be delivered
       between the gateway chassises through the localnet port via physical network. If the LS-EXT is a  regular
       logical  switch  (backed  by  tunneling only, as in the use case of OVN interconnection), then the packet
       will be dropped on the source gateway chassis. The limitation is due the fact  that  distributed  gateway
       ports  are tied to physical location, and without physical network connection, we will end up with either
       dropping the packet or transferring it over the  tunnels  which  could  cause  bigger  problems  such  as
       broadcast packets being redirect repeatedly by different gateway chassises.

       With the limitation in mind, if a user do want the direct connectivity between the logical routers, it is
       better to create an internal logical switch connected to the logical routers with regular logical  router
       ports,  which  are completely distributed and the packets don’t have to leave a chassis unless necessary,
       which is more optimal than routing via the distributed gateway ports.

     ARP request and ND NS packet processing

       Due to the fact that ARP requests and ND NA  packets  are  usually  broadcast  packets,  for  performance
       reasons, OVN deals with requests that target OVN owned IP addresses (i.e., IP addresses configured on the
       router ports, VIPs, NAT IPs) in a specific way and only forwards them to the logical router that owns the
       target  IP  address.  This behavior is different than that of traditional switches and implies that other
       routers/hosts connected to the logical switch will not learn the MAC/IP binding from the request packet.

       All other ARP and ND packets are flooded in the L2 broadcast domain and to  all  attached  logical  patch
       ports.

     VIFs on the logical switch connected by a distributed gateway port

       Typically  the  logical  switch  connected  by  a  distributed gateway port is for external connectivity,
       usually to a physical network through a localnet  port  on  the  logical  switch,  or  to  a  remote  OVN
       deployment  through  OVN  Interconnection.  In  these cases there is no VIF ports required on the logical
       switch.

       While not very common, it is still possible to create VIF ports on the  logical  switch  connected  by  a
       distributed  gateway port, but there is a limitation that the logical ports need to reside on the gateway
       chassis where the distributed gateway port resides to get connectivity to other logical switches  through
       the  distributed  gateway port. There is no limitation for the VIFs to connect within the logical switch,
       or beyond the logical switch through other regular distributed logical router ports.

       A special case is when using distributed gateway ports for scalability purpose, as mentioned  earlier  in
       this  document.  The logical switches connected by distributed gateway ports are not for connectivity but
       just for regular VIFs. However, the above limitation usually does not matter because in this use case all
       the  VIFs  on  the  logical switch are located on the same chassis with the distributed gateway port that
       connects the logical switch.

   Multiple localnet logical switches connected to a Logical Router
       It is possible to have multiple logical  switches  each  with  a  localnet  port  (representing  physical
       networks)  connected  to  a logical router, in which one localnet logical switch may provide the external
       connectivity via a distributed gateway port and rest of the localnet logical switches use VLAN tagging in
       the  physical network. It is expected that ovn-bridge-mappings is configured appropriately on the chassis
       for all these localnet networks.

     East West routing

       East-West routing between these localnet VLAN tagged logical switches work almost the same way as  normal
       logical switches. When the VM sends such a packet, then:

              1.  It  first enters the ingress pipeline, and then egress pipeline of the source localnet logical
                  switch datapath. It then enters the ingress pipeline of the logical router  datapath  via  the
                  logical router port in the source chassis.

              2.  Routing decision is taken.

              3.  From  the  router datapath, packet enters the ingress pipeline and then egress pipeline of the
                  destination localnet logical switch datapath and goes out of the  integration  bridge  to  the
                  provider  bridge  (  belonging to the destination logical switch) via the localnet port. While
                  sending the packet to provider bridge, we also replace router port MAC as source  MAC  with  a
                  chassis unique MAC.

                  This chassis unique MAC is configured as global ovs config on each chassis (eg. via "ovs-vsctl
                  set  open  .  external-ids:  ovn-chassis-mac-mappings="phys:aa:bb:cc:dd:ee:$i$i"").  For  more
                  details, see ovn-controller(8).

                  If  the  above  is  not  configured,  then source MAC would be the router port MAC. This could
                  create problem if we have more than one chassis. This is because, since  the  router  port  is
                  distributed,  the  same  (MAC,VLAN)  tuple will seen by physical network from other chassis as
                  well, which could cause these issues:

                  •      Continuous MAC moves in top-of-rack switch (ToR).

                  •      ToR dropping the traffic, which is causing continuous MAC moves.

                  •      ToR blocking the ports from which MAC moves are happening.

              4.  The destination chassis receives the packet  via  the  localnet  port  and  sends  it  to  the
                  integration  bridge.  Before entering the integration bridge the source mac of the packet will
                  be replaced with router port mac again. The packet enters the ingress pipeline and then egress
                  pipeline  of  the  destination  localnet  logical  switch  and  finally  gets delivered to the
                  destination VM port.

     External traffic

       The following happens when a VM sends an external  traffic  (which  requires  NATting)  and  the  chassis
       hosting the VM doesn’t have a distributed gateway port.

              1.  The  packet first enters the ingress pipeline, and then egress pipeline of the source localnet
                  logical switch datapath. It then enters the ingress pipeline of the  logical  router  datapath
                  via the logical router port in the source chassis.

              2.  Routing  decision  is  taken. Since the gateway router or the distributed gateway port doesn’t
                  reside in the source chassis, the traffic is redirected to the gateway chassis via the  tunnel
                  port.

              3.  The  gateway  chassis receives the packet via the tunnel port and the packet enters the egress
                  pipeline of the logical router datapath. NAT rules are applied here. The  packet  then  enters
                  the  ingress  pipeline  and then egress pipeline of the localnet logical switch datapath which
                  provides external connectivity and finally goes out via  the  localnet  port  of  the  logical
                  switch which provides external connectivity.

       Although  this  works,  the  VM  traffic  is  tunnelled when sent from the compute chassis to the gateway
       chassis. In order for it to work properly, the MTU of the localnet logical switches must  be  lowered  to
       account for the tunnel encapsulation.

   Centralized routing for localnet VLAN tagged logical switches connected to a Logical Router
       To  overcome  the tunnel encapsulation problem described in the previous section, OVN supports the option
       of enabling centralized routing for localnet VLAN tagged logical switches. CMS can configure  the  option
       options:reside-on-redirect-chassis  to  true  for each Logical_Router_Port which connects to the localnet
       VLAN tagged logical switches. This causes the gateway chassis (hosting the distributed gateway  port)  to
       handle  all  the routing for these networks, making it centralized. It will reply to the ARP requests for
       the logical router port IPs.

       If the logical router doesn’t have a distributed gateway port connecting to the localnet  logical  switch
       which  provides  external  connectivity,  or if it has more than one distributed gateway ports, then this
       option is ignored by OVN.

       The following happens when a VM sends an east-west traffic which needs to be routed:

              1.  The packet first enters the ingress pipeline, and then egress pipeline of the source  localnet
                  logical  switch  datapath  and  is sent out via a localnet port of the source localnet logical
                  switch (instead of sending it to router pipeline).

              2.  The gateway chassis receives the packet via a localnet port of  the  source  localnet  logical
                  switch  and  sends  it to the integration bridge. The packet then enters the ingress pipeline,
                  and then egress pipeline of the source localnet logical switch datapath and enters the ingress
                  pipeline of the logical router datapath.

              3.  Routing decision is taken.

              4.  From  the  router datapath, packet enters the ingress pipeline and then egress pipeline of the
                  destination localnet logical switch datapath. It then goes out of the  integration  bridge  to
                  the provider bridge ( belonging to the destination logical switch) via a localnet port.

              5.  The  destination  chassis  receives  the  packet  via  a  localnet  port  and  sends it to the
                  integration bridge. The packet enters the ingress pipeline and then  egress  pipeline  of  the
                  destination localnet logical switch and finally delivered to the destination VM port.

       The following happens when a VM sends an external traffic which requires NATting:

              1.  The  packet first enters the ingress pipeline, and then egress pipeline of the source localnet
                  logical switch datapath and is sent out via a localnet port of  the  source  localnet  logical
                  switch (instead of sending it to router pipeline).

              2.  The  gateway  chassis  receives  the packet via a localnet port of the source localnet logical
                  switch and sends it to the integration bridge. The packet then enters  the  ingress  pipeline,
                  and then egress pipeline of the source localnet logical switch datapath and enters the ingress
                  pipeline of the logical router datapath.

              3.  Routing decision is taken and NAT rules are applied.

              4.  From the router datapath, packet enters the ingress pipeline and then egress pipeline  of  the
                  localnet logical switch datapath which provides external connectivity. It then goes out of the
                  integration bridge to the provider bridge (belonging to  the  logical  switch  which  provides
                  external connectivity) via a localnet port.

       The following happens for the reverse external traffic.

              1.  The  gateway  chassis  receives  the  packet  from a localnet port of the logical switch which
                  provides external connectivity. The packet then enters the ingress pipeline  and  then  egress
                  pipeline  of  the  localnet  logical switch (which provides external connectivity). The packet
                  then enters the ingress pipeline of the logical router datapath.

              2.  The ingress pipeline of the logical router datapath applies the unNATting  rules.  The  packet
                  then  enters  the  ingress  pipeline  and  then egress pipeline of the source localnet logical
                  switch. Since the source VM doesn’t reside in the gateway chassis, the packet is sent out  via
                  a localnet port of the source logical switch.

              3.  The  source  chassis  receives  the packet via a localnet port and sends it to the integration
                  bridge. The packet enters the ingress pipeline and then egress pipeline of the source localnet
                  logical switch and finally gets delivered to the source VM port.

       As   an   alternative   to  reside-on-redirect-chassis,  OVN  supports  VLAN-based  redirection.  Whereas
       reside-on-redirect-chassis centralizes all router functionality, VLAN-based redirection only changes  how
       OVN  redirects  packets  to  the  gateway  chassis.  By  setting  options:redirect-type  to  bridged on a
       distributed gateway port, OVN redirects packets to the gateway chassis using the  localnet  port  of  the
       router’s peer logical switch, instead of a tunnel.

       If  the  logical router doesn’t have a distributed gateway port connecting to the localnet logical switch
       which provides external connectivity, or if it has more than one distributed  gateway  ports,  then  this
       option is ignored by OVN.

       Following happens for bridged redirection:

              1.  On compute chassis, packet passes though logical router’s ingress pipeline.

              2.  If  logical  outport  is  gateway  chassis attached router port then packet is "redirected" to
                  gateway chassis using peer logical switch’s localnet port.

              3.  This redirected packet has destination mac as router  port  mac  (the  one  to  which  gateway
                  chassis is attached). Its VLAN id is that of localnet port (peer logical switch of the logical
                  router port).

              4.  On the gateway chassis packet will enter the logical router pipeline again and  this  time  it
                  will passthrough egress pipeline as well.

              5.  Reverse traffic packet flows stays the same.

       Some guidelines and expections with bridged redirection:

              1.  Since  router  port  mac  is destination mac, hence it has to be ensured that physical network
                  learns it on ONLY from the gateway chassis. Which means that  ovn-chassis-mac-mappings  should
                  be  configure  on  all the compute nodes, so that physical network never learn router port mac
                  from compute nodes.

              2.  Since packet enters logical router ingress pipeline twice (once on compute chassis  and  again
                  on gateway chassis), hence ttl will be decremented twice.

              3.  Default  redirection  type  continues to be overlay. User can switch the redirect-type between
                  bridged and overlay by changing the value of options:redirect-type

   Life Cycle of a VTEP gateway
       A gateway is a chassis that forwards traffic between the OVN-managed part of  a  logical  network  and  a
       physical VLAN, extending a tunnel-based logical network into a physical network.

       The  steps  below  refer  often  to  details  of the OVN and VTEP database schemas. Please see ovn-sb(5),
       ovn-nb(5) and vtep(5), respectively, for the full story on these databases.

              1.  A VTEP gateway’s life cycle begins with the administrator registering the VTEP  gateway  as  a
                  Physical_Switch  table  entry  in the VTEP database. The ovn-controller-vtep connected to this
                  VTEP database, will recognize the new VTEP gateway and create a new Chassis table entry for it
                  in the OVN_Southbound database.

              2.  The administrator can then create a new Logical_Switch table entry, and bind a particular vlan
                  on a VTEP gateway’s port to any VTEP logical switch. Once a VTEP logical switch is bound to  a
                  VTEP   gateway,   the   ovn-controller-vtep   will   detect   it  and  add  its  name  to  the
                  vtep_logical_switches column of the Chassis table in the OVN_Southbound  database.  Note,  the
                  tunnel_key  column  of  VTEP logical switch is not filled at creation. The ovn-controller-vtep
                  will set the column when the corresponding vtep logical switch is  bound  to  an  OVN  logical
                  network.

              3.  Now,  the  administrator  can  use  the  CMS  to  add a VTEP logical switch to the OVN logical
                  network. To do that, the CMS must first create a new Logical_Switch_Port table  entry  in  the
                  OVN_Northbound  database. Then, the type column of this entry must be set to "vtep". Next, the
                  vtep-logical-switch  and  vtep-physical-switch  keys  in  the  options  column  must  also  be
                  specified,  since multiple VTEP gateways can attach to the same VTEP logical switch. Next, the
                  addresses column of this logical port must be set to "unknown", it will add a priority 0 entry
                  in  "ls_in_l2_lkup"  stage of logical switch ingress pipeline. So, traffic with unrecorded mac
                  by OVN would go through the Logical_Switch_Port to physical network.

              4.  The newly created logical port in the OVN_Northbound database and its  configuration  will  be
                  passed   down  to  the  OVN_Southbound  database  as  a  new  Port_Binding  table  entry.  The
                  ovn-controller-vtep will recognize the change and bind the logical port to  the  corresponding
                  VTEP gateway chassis. Configuration of binding the same VTEP logical switch to a different OVN
                  logical networks is not allowed and a warning will be generated in the log.

              5.  Beside binding to the VTEP gateway chassis, the ovn-controller-vtep will update the tunnel_key
                  column  of  the  VTEP  logical  switch  to  the  corresponding  Datapath_Binding table entry’s
                  tunnel_key for the bound OVN logical network.

              6.  Next,  the  ovn-controller-vtep  will  keep  reacting  to  the  configuration  change  in  the
                  Port_Binding  in  the OVN_Northbound database, and updating the Ucast_Macs_Remote table in the
                  VTEP database. This allows the VTEP gateway to understand where to forward the unicast traffic
                  coming from the extended external network.

              7.  Eventually,  the  VTEP  gateway’s  life cycle ends when the administrator unregisters the VTEP
                  gateway from the VTEP database. The ovn-controller-vtep will recognize the  event  and  remove
                  all  related  configurations  (Chassis  table  entry  and port bindings) in the OVN_Southbound
                  database.

              8.  When the ovn-controller-vtep is terminated, all related configurations in  the  OVN_Southbound
                  database  and  the  VTEP  database  will  be  cleaned, including Chassis table entries for all
                  registered VTEP gateways and their port bindings, and all Ucast_Macs_Remote table entries  and
                  the Logical_Switch tunnel keys.

   OVN Deployments Interconnection
       It  is  not  uncommon  for an operator to deploy multiple OVN clusters, for two main reasons. Firstly, an
       operator may prefer to deploy one OVN cluster for each availability  zone,  e.g.  in  different  physical
       regions,  to  avoid  single  point  of failure. Secondly, there is always an upper limit for a single OVN
       control plane to scale.

       Although the control planes of the different availability zone (AZ)s are independent from each other, the
       workloads  from  different  AZs may need to communicate across the zones. The OVN interconnection feature
       provides a native way to interconnect different AZs  by  L3  routing  through  transit  overlay  networks
       between logical routers of different AZs.

       A  global  OVN  Interconnection  Northbound database is introduced for the operator (probably through CMS
       systems) to configure transit logical switches that connect logical routers from different AZs. A transit
       switch  is  similar  to  a  regular  logical  switch,  but  it  is used for interconnection purpose only.
       Typically, each transit switch can be used to connect all logical routers  that  belong  to  same  tenant
       across all AZs.

       A  dedicated daemon process ovn-ic, OVN interconnection controller, in each AZ will consume this data and
       populate corresponding logical switches to their own northbound databases for each AZ,  so  that  logical
       routers  can  be  connected  to  the  transit  switch  by  creating  patch port pairs in their northbound
       databases. Any router ports connected to the transit switches are considered interconnection ports, which
       will be exchanged between AZs.

       Physically,  when  workloads  from  different  AZs communicate, packets need to go through multiple hops:
       source chassis, source gateway, destination gateway and destination chassis. All these hops are connected
       through  tunnels so that the packets never leave overlay networks. A distributed gateway port is required
       to connect the logical router to a transit switch, with a gateway chassis specified, so that the  traffic
       can be forwarded through the gateway chassis.

       A  global  OVN Interconnection Southbound database is introduced for exchanging control plane information
       between the AZs. The data in this database is populated and consumed by the ovn-ic, of each AZ. The  main
       information in this database includes:

              •      Datapath bindings for transit switches, which mainly contains the tunnel keys generated for
                     each transit switch. Separate key ranges are reserved for transit  switches  so  that  they
                     will never conflict with any tunnel keys locally assigned for datapaths within each AZ.

              •      Availability zones, which are registered by ovn-ic from each AZ.

              •      Gateways.  Each  AZ  specifies  chassises  that  are  supposed  to  work as interconnection
                     gateways, and the ovn-ic will populate this information to the  interconnection  southbound
                     DB.  The  ovn-ic  from  all the other AZs will learn the gateways and populate to their own
                     southbound DB as a chassis.

              •      Port bindings for logical switch ports created on the transit  switch.  Each  AZ  maintains
                     their  logical router to transit switch connections independently, but ovn-ic automatically
                     populates local port bindings on transit switches to the global interconnection  southbound
                     DB,  and  learns  remote  port  bindings  from  other  AZs  back  to its own northbound and
                     southbound DBs, so that logical flows can be produced and  then  translated  to  OVS  flows
                     locally, which finally enables data plane communication.

              •      Routes  that  are  advertised  between  different AZs. If enabled, routes are automatically
                     exchanged by ovn-ic. Both static routes and  directly  connected  subnets  are  advertised.
                     Options in options column of the NB_Global table of OVN_NB database control the behavior of
                     route advertisement,  such  as  enable/disable  the  advertising/learning  routes,  whether
                     default  routes  are  advertised/learned,  and  blacklisted  CIDRs.  See ovn-nb(5) for more
                     details.

       The tunnel keys for transit switch datapaths and related port bindings must be  agreed  across  all  AZs.
       This is ensured by generating and storing the keys in the global interconnection southbound database. Any
       ovn-ic from any AZ can allocate the key, but race conditions are solved by enforcing unique index for the
       column in the database.

       Once each AZ’s NB and SB databases are populated with interconnection switches and ports, and agreed upon
       the tunnel keys, data plane communication between the AZs are established.

       When VXLAN tunneling is enabled in an  OVN  cluster,  due  to  the  limited  range  available  for  VNIs,
       Interconnection feature is not supported.

     A day in the life of a packet crossing AZs

              1.  An  IP  packet  is  sent  out  from  a  VIF  on a hypervisor (HV1) of AZ1, with destination IP
                  belonging to a VIF in AZ2.

              2.  In HV1’s OVS flow tables, the packet goes through logical switch and logical router pipelines,
                  and in a logical router pipeline, the routing stage finds out the next hop for the destination
                  IP, which belongs to a remote logical router port in AZ2, and the  output  port,  which  is  a
                  chassis-redirect  port  located  on  an interconnection gateway (GW1 in AZ1), so HV1 sends the
                  packet to GW1 through tunnel.

              3.  On GW1, it continues with the logical router pipe line and switches to  the  transit  switch’s
                  pipeline  through the peer port of the chassis redirect port. In the transit switch’s pipeline
                  it outputs to the remote logical port which is located on a gateway (GW2) in AZ2, so  the  GW1
                  sends the packet to GW2 in tunnel.

              4.  On  GW2,  it  continues  with  the  transit switch pipeline and switches to the logical router
                  pipeline through the peer port, which is a chassis redirect port that is located on  GW2.  The
                  logical  router  pipeline  then forwards the packet to relevant logical pipelines according to
                  the destination IP address, and figures out the MAC and location of the destination VIF port -
                  a hypervisor (HV2). The GW2 then sends the packet to HV2 in tunnel.

              5.  On HV2, the packet is delivered to the final destination VIF port by the logical switch egress
                  pipeline, just the same way as for intra-AZ communications.

   Native OVN services for external logical ports
       To support OVN native services (like DHCP/IPv6 RA/DNS lookup) to the cloud resources which are  external,
       OVN supports external logical ports.

       Below are some of the use cases where external ports can be used.

              •      VMs  connected to SR-IOV nics - Traffic from these VMs by passes the kernel stack and local
                     ovn-controller do not bind these ports and cannot serve the native services.

              •      When CMS supports provisioning baremetal servers.

       OVN will provide the native services if CMS has done  the  below  configuration  in  the  OVN  Northbound
       Database.

              •      A  row  is created in Logical_Switch_Port, configuring the addresses column and setting the
                     type to external.

              •      ha_chassis_group column is configured.

              •      The HA chassis which belongs to the HA chassis group has the ovn-bridge-mappings configured
                     and  has  proper  L2 connectivity so that it can receive the DHCP and other related request
                     packets from these external resources.

              •      The Logical_Switch of this port has a localnet port.

              •      Native OVN services are enabled by configuring the DHCP and other options like the  way  it
                     is done for the normal logical ports.

       It  is  recommended  to  use  the  same  HA chassis group for all the external ports of a logical switch.
       Otherwise, the physical switch might see MAC  flap  issue  when  different  chassis  provide  the  native
       services.  For  example  when  supporting  native  DHCPv4  service,  DHCPv4  server  mac  (configured  in
       options:server_mac column in table DHCP_Options) originating from different  ports  can  cause  MAC  flap
       issue.  The MAC of the logical router IP(s) can also flap if the same HA chassis group is not set for all
       the external ports of a logical switch.

SECURITY

   Role-Based Access Controls for the Southbound DB
       In order to provide additional security against the possibility of an OVN chassis becoming compromised in
       such  a  way  as to allow rogue software to make arbitrary modifications to the southbound database state
       and thus disrupt the OVN network, role-based access controls (see ovsdb-server(1) for additional details)
       are provided for the southbound database.

       The  implementation  of role-based access controls (RBAC) requires the addition of two tables to an OVSDB
       schema: the RBAC_Role table, which is indexed by role name and maps the the names of the  various  tables
       that  may  be  modifiable  for a given role to individual rows in a permissions table containing detailed
       permission information for that role, and the permission table itself which consists of  rows  containing
       the following information:

              Table Name
                     The name of the associated table. This column exists primarily as an aid for humans reading
                     the contents of this table.

              Auth Criteria
                     A set of strings  containing  the  names  of  columns  (or  column:key  pairs  for  columns
                     containing  string:string  maps). The contents of at least one of the columns or column:key
                     values in a row to be modified, inserted, or deleted must be equal to the ID of the  client
                     attempting  to  act  on  the  row  in  order  for  the  authorization check to pass. If the
                     authorization criteria is empty, authorization checking is disabled and all clients for the
                     role will be treated as authorized.

              Insert/Delete
                     Row  insertion/deletion permission; boolean value indicating whether insertion and deletion
                     of rows is allowed for the associated table. If true, insertion and  deletion  of  rows  is
                     allowed for authorized clients.

              Updatable Columns
                     A set of strings containing the names of columns or column:key pairs that may be updated or
                     mutated by authorized clients. Modifications to columns within a  row  are  only  permitted
                     when  the  authorization  check  for  the  client passes and all columns to be modified are
                     included in this set of modifiable columns.

       RBAC configuration for the OVN southbound database  is  maintained  by  ovn-northd.  With  RBAC  enabled,
       modifications  are  only  permitted for the Chassis, Encap, Port_Binding, and MAC_Binding tables, and are
       restricted as follows:

              Chassis
                     Authorization: client ID must match the chassis name.

                     Insert/Delete: authorized row insertion and deletion are permitted.

                     Update: The columns nb_cfg, external_ids, encaps, and vtep_logical_switches may be modified
                     when authorized.

              Encap  Authorization: client ID must match the chassis name.

                     Insert/Delete: row insertion and row deletion are permitted.

                     Update: The columns type, options, and ip can be modified.

              Port_Binding
                     Authorization:  disabled  (all  clients are considered authorized. A future enhancement may
                     add columns (or keys to external_ids) in order to control which chassis are allowed to bind
                     each port.

                     Insert/Delete:  row insertion/deletion are not permitted (ovn-northd maintains rows in this
                     table.

                     Update: Only modifications to the chassis column are permitted.

              MAC_Binding
                     Authorization: disabled (all clients are considered to be authorized).

                     Insert/Delete: row insertion/deletion are permitted.

                     Update: The columns logical_port, ip, mac, and datapath may be modified by ovn-controller.

              IGMP_Group
                     Authorization: disabled (all clients are considered to be authorized).

                     Insert/Delete: row insertion/deletion are permitted.

                     Update: The columns  address,  chassis,  datapath,  and  ports  may  be  modified  by  ovn-
                     controller.

       Enabling RBAC for ovn-controller connections to the southbound database requires the following steps:

              1.  Creating  SSL  certificates  for each chassis with the certificate CN field set to the chassis
                  name (e.g. for a chassis with external-ids:system-id=chassis-1, via the  command  "ovs-pki  -u
                  req+sign chassis-1 switch").

              2.  Configuring  each  ovn-controller  to use SSL when connecting to the southbound database (e.g.
                  via "ovs-vsctl set open .  external-ids:ovn-remote=ssl:x.x.x.x:6642").

              3.  Configuring a southbound database SSL remote with "ovn-controller" role (e.g.  via  "ovn-sbctl
                  set-connection role=ovn-controller pssl:6642").

   Encrypt Tunnel Traffic with IPsec
       OVN  tunnel traffic goes through physical routers and switches. These physical devices could be untrusted
       (devices in public network) or might be compromised.  Enabling  encryption  to  the  tunnel  traffic  can
       prevent the traffic data from being monitored and manipulated.

       The  tunnel  traffic  is  encrypted with IPsec. The CMS sets the ipsec column in the northbound NB_Global
       table to enable or disable IPsec encrytion. If ipsec is true, all OVN tunnels will be encrypted. If ipsec
       is false, no OVN tunnels will be encrypted.

       When  CMS  updates the ipsec column in the northbound NB_Global table, ovn-northd copies the value to the
       ipsec column in the southbound SB_Global table. ovn-controller in each chassis  monitors  the  southbound
       database  and  sets the options of the OVS tunnel interface accordingly. OVS tunnel interface options are
       monitored by the ovs-monitor-ipsec daemon which configures IKE daemon to set up IPsec connections.

       Chassis authenticates each other by using certificate. The authentication succeeds if the  other  end  in
       tunnel  presents  a  certificate  signed  by  a  trusted CA and the common name (CN) matches the expected
       chassis name. The SSL certificates used in role-based access controls (RBAC) can be used in IPsec. Or use
       ovs-pki  to create different certificates. The certificate is required to be x.509 version 3, and with CN
       field and subjectAltName field being set to the chassis name.

       The CA certificate, chassis certificate and private key are required to  be  installed  in  each  chassis
       before enabling IPsec. Please see ovs-vswitchd.conf.db(5) for setting up CA based IPsec authentication.

DESIGN DECISIONS

   Tunnel Encapsulations
       In  general,  OVN annotates logical network packets that it sends from one hypervisor to another with the
       following three pieces of metadata, which are encoded in an encapsulation-specific fashion:

              •      24-bit logical datapath identifier, from  the  tunnel_key  column  in  the  OVN  Southbound
                     Datapath_Binding table.

              •      15-bit logical ingress port identifier. ID 0 is reserved for internal use within OVN. IDs 1
                     through 32767, inclusive, may be assigned to logical ports (see the  tunnel_key  column  in
                     the OVN Southbound Port_Binding table).

              •      16-bit  logical  egress  port  identifier. IDs 0 through 32767 have the same meaning as for
                     logical ingress ports. IDs 32768 through 65535,  inclusive,  may  be  assigned  to  logical
                     multicast groups (see the tunnel_key column in the OVN Southbound Multicast_Group table).

       When  VXLAN  is  enabled  on  any hypervisor in a cluster, datapath and egress port identifier ranges are
       reduced to 12-bits. This is done because only STT and Geneve provide the large space for  metadata  (over
       32 bits per packet). To accommodate for VXLAN, 24 bits available are split as follows:

              •      12-bit  logical  datapath  identifier,  derived  from  the  tunnel_key  column  in  the OVN
                     Southbound Datapath_Binding table.

              •      12-bit logical egress port identifier. IDs 0 through  2047  are  used  for  unicast  output
                     ports.  IDs  2048 through 4095, inclusive, may be assigned to logical multicast groups (see
                     the tunnel_key column in the OVN Southbound Multicast_Group  table).  For  multicast  group
                     tunnel  keys,  a  special  mapping scheme is used to internally transform from internal OVN
                     16-bit keys to 12-bit values before sending packets through a VXLAN tunnel, and  back  from
                     12-bit tunnel keys to 16-bit values when receiving packets from a VXLAN tunnel.

              •      No logical ingress port identifier.

       The  limited  space  available for metadata when VXLAN tunnels are enabled in a cluster put the following
       functional limitations onto features available to users:

              •      The maximum number of networks is reduced to 4096.

              •      The maximum number of ports per network is reduced to 2048.

              •      ACLs matching against logical ingress port identifiers are not supported.

              •      OVN interconnection feature is not supported.

       In addition to functional limitations described above, the following should be considered before enabling
       it in your cluster:

              •      STT  and  Geneve  use randomized UDP or TCP source ports that allows efficient distribution
                     among multiple paths in environments that use ECMP in their underlay.

              •      NICs are available to offload STT and Geneve encapsulation and decapsulation.

       Due  to  its  flexibility,  the  preferred  encapsulation  between  hypervisors  is  Geneve.  For  Geneve
       encapsulation, OVN transmits the logical datapath identifier in the Geneve VNI. OVN transmits the logical
       ingress and logical egress ports in a TLV with class 0x0102, type 0x80, and a  32-bit  value  encoded  as
       follows, from MSB to LSB:

         1       15          16
       +---+------------+-----------+
       |rsv|ingress port|egress port|
       +---+------------+-----------+
         0

       Environments whose NICs lack Geneve offload may prefer STT encapsulation for performance reasons. For STT
       encapsulation, OVN encodes all three pieces of logical metadata in the STT 64-bit tunnel ID  as  follows,
       from MSB to LSB:

           9          15          16         24
       +--------+------------+-----------+--------+
       |reserved|ingress port|egress port|datapath|
       +--------+------------+-----------+--------+
           0

       For connecting to gateways, in addition to Geneve and STT, OVN supports VXLAN, because only VXLAN support
       is common on top-of-rack (ToR) switches.  Currently,  gateways  have  a  feature  set  that  matches  the
       capabilities  as  defined  by  the  VTEP  schema, so fewer bits of metadata are necessary. In the future,
       gateways that do not support encapsulations with large amounts of metadata may continue to have a reduced
       feature set.