Provided by: nut-server_2.8.1-3.1ubuntu2_amd64 
      
    
NAME
       rhino - Driver for Brazilian Microsol RHINO UPS equipment
NOTE
       This man page only documents the hardware-specific features of the rhino driver. For information about
       the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
       This driver has been tested with:
       •   Rhino 6000 VA
       •   Rhino 7500 VA
       •   Rhino 10000 VA
       •   Rhino 20000 VA
       All Rhino models are sinusoidal on-line.
EXTRA ARGUMENTS
       This driver support the following extra optional settings in ups.conf(5):
       battext = n - (default = 0, no extra battery, where n = Ampere*hour )
COMMANDS
       •   load.on - Turn on the load immediately
       •   load.off - Turn off the load immediately
       •   bypass.start - Put the UPS in bypass mode
       •   bypass.stop - Put the UPS out of bypass mode
       •   shutdown.stayoff - Shut down in 3 minutes and do not return
AUTHOR
       Silvino B. Magalhães <sbm2yk@gmail.com>
SEE ALSO
   The core driver:
       nutupsdrv(8)
   Internet resources:
       The NUT (Network UPS Tools) home page: https://www.networkupstools.org/
Network UPS Tools 2.8.1                            03/31/2024                                           RHINO(8)