Provided by: libsystemd-dev_255.4-1ubuntu8.5_amd64 bug

NAME

       sd_bus_add_object_manager - Add a D-Bus object manager for a D-Bus object sub-tree

SYNOPSIS

       #include <systemd/sd-bus.h>

       int sd_bus_add_object_manager(sd_bus *bus, sd_bus_slot **slot, const char *path);

DESCRIPTION

       sd_bus_add_object_manager() installs a handler for the given path that implements the GetManagedObjects()
       method of the org.freedesktop.DBus.ObjectManager interface. See org.freedesktop.DBus.ObjectManager[1] for
       more information.

       To implement the InterfacesAdded and InterfacesRemoved signals of the org.freedesktop.DBus.ObjectManager
       interface, call sd_bus_emit_interfaces_added(3) and sd_bus_emit_interfaces_removed(3) whenever interfaces
       are added or removed from the sub-tree, respectively.

       When sd_bus_add_object_manager() succeeds, a slot is created internally. If the output parameter slot is
       NULL, a "floating" slot object is created, see sd_bus_slot_set_floating(3). Otherwise, a pointer to the
       slot object is returned. In that case, the reference to the slot object should be dropped when the object
       manager is not needed anymore, see sd_bus_slot_unref(3).

RETURN VALUE

       On success, sd_bus_add_object_manager() returns a non-negative integer. On failure, it returns a negative
       errno-style error code.

   Errors
       Returned errors may indicate the following problems:

       -EINVAL
           One of the required parameters is NULL or path is not a valid object path.

           Added in version 246.

       -ENOPKG
           The bus cannot be resolved.

           Added in version 246.

       -ECHILD
           The bus was created in a different process, library or module instance.

           Added in version 246.

       -ENOMEM
           Memory allocation failed.

           Added in version 246.

NOTES

       Functions described here are available as a shared library, which can be compiled against and linked to
       with the libsystemd pkg-config(1) file.

       The code described here uses getenv(3), which is declared to be not multi-thread-safe. This means that
       the code calling the functions described here must not call setenv(3) from a parallel thread. It is
       recommended to only do calls to setenv() from an early phase of the program when no other threads have
       been started.

HISTORY

       sd_bus_add_object_manager() was added in version 246.

SEE ALSO

       sd-bus(3), busctl(1), sd_bus_add_object_vtable(3), sd_bus_emit_interfaces_added(3), sd_bus_slot_unref(3)

NOTES

        1. org.freedesktop.DBus.ObjectManager
           https://dbus.freedesktop.org/doc/dbus-specification.html#standard-interfaces-objectmanager