Provided by: freeipmi-tools_1.6.13-3_amd64 bug

NAME

       ipmipower - IPMI power control utility

SYNOPSIS

       ipmipower [OPTION...]

DESCRIPTION

       Ipmipower  allows users to remotely power on, off, cycle, hard reset, get a power status query, perform a
       pulse diagnostic interrupt, or initiate a soft-shutdown of the OS via ACPI  through  the  IPMI  over  LAN
       protocol.

       When  a  power  command  (--on,  --off, --cycle, --reset, --stat, --pulse, or --soft) is specified on the
       command line, Ipmipower will attempt to run the power command on all hostnames listed on the command line
       then exit.

       If  no  power  commands  are  specified  on  the  command  line,  ipmipower will run in interactive mode.
       Interactive mode gives the user a command line interface  to  enter  various  commands.  Details  of  the
       interactive command line interface can be found below under INTERACTIVE COMMANDS.

       Listed  below  are  general IPMI options, tool specific options, trouble shooting information, workaround
       information, examples, and known issues. For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS

       The following options are general options for configuring IPMI communication and executing  general  tool
       commands.

       -D IPMIDRIVER, --driver-type=IPMIDRIVER
              Specify  the  driver  type  to  use  instead  of doing an auto selection.  The currently available
              outofband drivers are LAN and LAN_2_0, which perform IPMI 1.5 and IPMI 2.0 respectively.

       -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
              Specify the remote host(s) to communicate with. Multiple hostnames may be separated  by  comma  or
              may  be  specified  in  a  range  format;  see  HOSTRANGED  SUPPORT below. An optional port can be
              specified with each host, which may be useful  in  port  forwarding  or  similar  situations.   If
              specifying an IPv6 address and port, use the format [ADDRESS]:PORT.

       -u USERNAME, --username=USERNAME
              Specify  the  username  to use when authenticating with the remote host.  If not specified, a null
              (i.e. anonymous) username is assumed. The user must have atleast OPERATOR privileges  to  run  the
              --on,  --off,  --reset,  --cycle,  --pulse,  or  --soft power control commands. The user must have
              atleast USER privileges to determine the power status of the machine through --stat.

       -p PASSWORD, --password=PASSWORD
              Specify the password to use when authenticationg with the remote host.  If not specified,  a  null
              password is assumed. Maximum password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

       -P, --password-prompt
              Prompt for password to avoid possibility of listing it in process lists.

       -k K_G, --k-g=K_G
              Specify  the  K_g  BMC  key  to  use when authenticating with the remote host for IPMI 2.0. If not
              specified, a null key is assumed. To input the key in hexadecimal form,  prefix  the  string  with
              '0x'. E.g., the key 'abc' can be entered with the either the string 'abc' or the string '0x616263'

       -K, --k-g-prompt
              Prompt for k-g to avoid possibility of listing it in process lists.

       --session-timeout=MILLISECONDS
              Specify  the  session  timeout in milliseconds. Defaults to 20000 milliseconds (20 seconds) if not
              specified.

       --retransmission-timeout=MILLISECONDS
              Specify the packet retransmission timeout in  milliseconds.  Defaults  to  400  milliseconds  (0.4
              seconds) if not specified.

       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
              Specify  the IPMI 1.5 authentication type to use. The currently available authentication types are
              NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5. Defaults to MD5 if not specified.

       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
              Specify the IPMI  2.0  cipher  suite  ID  to  use.  The  Cipher  Suite  ID  identifies  a  set  of
              authentication,  integrity,  and confidentiality algorithms to use for IPMI 2.0 communication. The
              authentication algorithm identifies  the  algorithm  to  use  for  session  setup,  the  integrity
              algorithm  identifies  the algorithm to use for session packet signatures, and the confidentiality
              algorithm identifies the algorithm to use for payload encryption. Defaults to cipher suite ID 3 if
              not specified. The following cipher suite ids are currently supported:

              0 - Authentication Algorithm = None; Integrity Algorithm = None; Confidentiality Algorithm = None

              1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Confidentiality Algorithm =
              None

              2 - Authentication Algorithm = HMAC-SHA1;  Integrity  Algorithm  =  HMAC-SHA1-96;  Confidentiality
              Algorithm = None

              3  -  Authentication  Algorithm  =  HMAC-SHA1; Integrity Algorithm = HMAC-SHA1-96; Confidentiality
              Algorithm = AES-CBC-128

              6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confidentiality  Algorithm  =
              None

              7  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity Algorithm = HMAC-MD5-128; Confidentiality
              Algorithm = None

              8 - Authentication Algorithm =  HMAC-MD5;  Integrity  Algorithm  =  HMAC-MD5-128;  Confidentiality
              Algorithm = AES-CBC-128

              11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = None

              12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128; Confidentiality Algorithm
              = AES-CBC-128

              15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm = None; Confidentiality Algorithm
              = None

              16  -  Authentication  Algorithm   =   HMAC-SHA256;   Integrity   Algorithm   =   HMAC_SHA256_128;
              Confidentiality Algorithm = None

              17   -   Authentication   Algorithm   =   HMAC-SHA256;   Integrity  Algorithm  =  HMAC_SHA256_128;
              Confidentiality Algorithm = AES-CBC-128

       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
              Specify the privilege level to be  used.  The  currently  available  privilege  levels  are  USER,
              OPERATOR, and ADMIN. Defaults to OPERATOR if not specified.

       --config-file=FILE
              Specify an alternate configuration file.

       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
              Specify  workarounds  to vendor compliance issues. Multiple workarounds can be specified separated
              by commas. A special command line flag of "none", will indicate no workarounds (may be useful  for
              overriding configured defaults). See WORKAROUNDS below for a list of available workarounds.

       --debug
              Turn on debugging.

       -?, --help
              Output a help list and exit.

       --usage
              Output a usage message and exit.

       -V, --version
              Output the program version and exit.

IPMIPOWER OPTIONS

       The following options are specific to ipmipower.

       -n, --on
              Power on the target hosts.

       -f, --off
              Power off the target hosts.

       -c, --cycle
              Power cycle the target hosts.

       -r, --reset
              Reset the target hosts.

       -s, --stat
              Get power status of the target hosts.

       --pulse
              Send power diagnostic interrupt to target hosts.

       --soft Initiate a soft-shutdown of the OS via ACPI.

       --on-if-off
              The  IPMI  specification  does  not  require  the  power cycle or hard reset commands to turn on a
              machine that is currently powered off. This option will  force  ipmipower  to  issue  a  power  on
              command  instead of a power cycle or hard reset command if the remote machine's power is currently
              off.

       --wait-until-on
              The IPMI specification allows power on commands to return prior to the power  on  actually  taking
              place.  This  option  will force ipmipower to regularly query the remote BMC and return only after
              the machine has powered on.

       --wait-until-off
              The IPMI specification allows power off commands to return prior the  power  off  actually  taking
              place.  This  option  will force ipmipower to regularly query the remote BMC and return only after
              the machine has powered off.

       --oem-power-type=OEM-POWER-TYPE
              This option informs ipmipower to initiate power control operations via an IPMI OEM specific  power
              control  extension.  The  currently  available POWERTYPEs are NONE and C410X. Please see OEM POWER
              EXTENSIONS below for additional information.

IPMIPOWER ADVANCED NETWORK OPTIONS

       The following options are used to change the networking behavior of ipmipower.

       --retransmission-wait-timeout=MILLISECONDS
              Specify the retransmission wait timeout length in milliseconds. The retransmission wait timeout is
              similar  to  the  retransmission  timeout  above,  but  is  used specifically for power completion
              verification with the --wait-until-on and --wait-until-off options.  Defaults to 500  milliseconds
              (0.5 seconds).

       --retransmission-backoff-count=COUNT
              Specify  the  retransmission  backoff count for retransmissions. After ever COUNT retransmissions,
              the retransmission timeout length will be increased by another factor. Defaults to 8.

       --ping-interval=MILLISECONDS
              Specify the ping interval length in milliseconds. When running in interactive mode,  RMCP  (Remote
              Management  Control Protocol) discovery messages will be sent to all configured remote hosts every
              MILLISECONDS to confirm their support of IPMI. Power commands cannot be sent to a host until it is
              discovered  (or re-discovered if previously lost). Defaults to 5000 milliseconds (5 seconds). Ping
              discovery messages can be disabled by setting this value to 0. RMCP ping  discovery  messages  are
              automatically disabled in non-interactive mode.

       --ping-timeout=MILLISECONDS
              Specify  the  ping  timeout length in milliseconds. When running in interactive mode, RMCP (Remote
              Management Control Protocol) messages discovery will be sent to all  configured  remote  hosts  to
              confirm  their  support  of  IPMI.  A  remote host is considered undiscovered if the host does not
              respond in MILLISECONDS time. Defaults to 30000 milliseconds (30 seconds). The ping timeout cannot
              be larger than the ping interval.

       --ping-packet-count=COUNT
              Specify  the  ping  packet  count size. Defaults to 10. See the --ping-percent-fR option below for
              more information on this option.

       --ping-percent=PERCENT
              Specify the ping percent value. Defaults to 50.  Since IPMI is based on UDP, it is  difficult  for
              ipmipower  to  distinguish  between  a  missing  machine  and  a  bad  (or heavily loaded) network
              connection in interactive mode. when running in interactive mode.  For  example,  suppose  a  link
              consistently  drops  80%  of  the packets to a particular machine. The power control operation may
              have difficulty completing, although a recent pong response from RMCP makes ipmipower believe  the
              machine  is  up  and  functioning properly.  The ping packet count and percent options are used to
              alleviate this problem.  Ipmipower will monitor RMCP ping  packets  in  packet  count  chunks.  If
              ipmipower  does  not  receive  a response to greater than ping percent of those packets, ipmipower
              will assume the link to this node is bad and will not send power control operations to  that  node
              until  the  connection  is  determined  to  be reliable. This heuristic can be disabled by setting
              either the ping packet count or ping percent to 0. This feature is not used if  ping  interval  is
              set to 0.

       --ping-consec-count=COUNT
              Specify  the  ping consecutive count. This is another heuristic used to determine if a node should
              be considered discovered, undiscovered, or with a bad connection. If a valid  RMCP  pong  response
              was  received for the last COUNT ping packets, a node will be considered discovered, regardless of
              other heuristics listed above. Defaults to 5. This heuristic can be disabled by setting this value
              to 0. This feature is not used if other ping features described above are disabled.

HOSTRANGED OPTIONS

       The  following  options  manipulate  hostranged  output.  See  HOSTRANGED  SUPPORT  below  for additional
       information on hostranges.

       -B, --buffer-output
              Buffer hostranged output. For each node, buffer standard output until the node has  completed  its
              IPMI  operation.  When  specifying this option, data may appear to output slower to the user since
              the the entire IPMI operation must complete before any data can be output.  See HOSTRANGED SUPPORT
              below for additional information.

       -C, --consolidate-output
              Consolidate  hostranged  output.  The  complete  standard output from every node specified will be
              consolidated so that nodes with identical output are not output twice. A header  will  list  those
              nodes with the consolidated output. When this option is specified, no output can be seen until the
              IPMI operations to all nodes has completed. If the user breaks  out  of  the  program  early,  all
              currently  consolidated  output  will  be  dumped.  See  HOSTRANGED  SUPPORT  below for additional
              information.

       -F NUM, --fanout=NUM
              Specify multiple host fanout. Indicates the maximum number of power control operations that can be
              executed in parallel.

       -E, --eliminate
              Eliminate  hosts determined as undetected by ipmidetect.  This attempts to remove the common issue
              of hostranged execution timing out due to several nodes being removed  from  service  in  a  large
              cluster. The ipmidetectd daemon must be running on the node executing the command.

       --always-prefix
              Always  prefix output, even if only one host is specified or communicating in-band. This option is
              primarily useful for scripting purposes. Option will be ignored if specified with the -C option.

INTERACTIVE COMMANDS

       Ipmipower provides the following interactive  commands  at  the  ipmipower>  prompt.   Before  any  power
       commands  (on,  off,  cycle,  reset, stat, pulse, or soft) can be used, hostnames must be configured into
       ipmipower, either through the command prompt or the hostname command below. The parameters and options to
       the commands below mirror their appropriate command line options.

       hostname [IPMIHOST(s)]
              Specify a new set of hosts. No input to unconfigure all hosts.

       username [USERNAME]
              Specify a new username. No input for null username.

       password [PASSWORD]
              Specify a new password. No input for null password.

       k_g [K_G]
              Specify a new K_g BMC Key. No input for null key. Prefix with '0x' to enter a key in hexadecimal

       ipmi-version IPMIVERSION
              Specify the ipmi version to use.

       session-timeout MILLISECONDS
              Specify a new session timeout length.

       retransmission-timeout MILLISECONDS
              Specify a new retransmiision timeout length.

       authentication-type AUTHENTICATION-TYPE
              Specify the authentication type to use.

       cipher-suite-id CIPHER-SUITE-ID
              Specify the cipher suite id to use.

       privilege-level PRIVILEGE-LEVEL
              Specify the privilege level to use.

       workaround-flags WORKAROUNDS
              Specify workaround flags.

       debug [on|off]
              Toggle debug output.

       on [IPMIHOST(s)]
              Turn on all configured hosts or specified hosts.

       off [IPMIHOST(s)]
              Turn off all configured hosts or specified hosts.

       cycle [IPMIHOST(s)]
              Power cycle all configured hosts or specified hosts.

       reset [IPMIHOST(s)]
              Reset all configured hosts or specified hosts.

       stat [IPMIHOST(s)]
              Query power status for all configured hosts or specified hosts.

       pulse [IPMIHOST(s)]
              Pulse diagnostic interrupt all configured hosts or specified hosts.

       soft [IPMIHOST(s)]
              Initiate a soft-shutdown for all configured hosts or specified hosts.

       identify-on [IPMIHOST(s)]
              Turn on physical system identification.

       identify-off [IPMIHOST(s)]
              Turn off physical system identification.

       identify-status [IPMIHOST(s)]
              Query physical system identification status.

       on-if-off [on|off]
              Toggle on-if-off functionality.

       wait-until-on [on|off]
              Toggle wait-until-on functionality.

       wait-until-off [on|off]
              Toggle wait-until-off functionality.

       retransmission-wait-timeout MILLISECONDS
              Specify a new retransmission wait timeout length.

       retransmission-backoff-count COUNT
              Specify a new retransmission backoff count.

       ping-interval MILLISECONDS
              Specify a new ping interval length.

       ping-timeout MILLISECONDS
              Specify a new ping timeout length.

       ping-packet-count COUNT
              Specify a new ping packet count.

       ping-percent PERCENT
              Specify a new ping percent.

       ping-consec-count COUNT
              Specify a new ping consec count.

       buffer-output [on|off]
              Toggle buffer-output functionality.

       consolidate-output [on|off]
              Toggle consolidate-output functionality.

       fanout COUNT
              Specify a fanout.

       always-prefix [on|off]
              Toggle always-prefix functionality.

       help   Output help menu.

       version
              Output version.

       config Output the current configuration.

       quit   Quit program.

OEM POWER EXTENSIONS

       Some  motherboards include IPMI OEM extensions for alternate power control mechanisms. For example, these
       power control mechanisms may allow you to power control a sub-device within the system  rather  than  the
       entire system itself.

       By  specifying  an  OEM  power type via --oem-power-type on the command line or freeipmi.conf(5), you can
       instruct ipmipower to execute alternate power control implementations over the standard  ones.  Depending
       on  the  OEM  extension,  some  power  control  commands  may no longer be available. For example, an OEM
       extension may allow on but not cycle. Specific ipmipower options may not longer function either.

       Some OEM extensions may require additional arguments for their power control action, such as a sub-device
       identifier. Additional arguments can be provided by appending a plus sign ('+') and the extra information
       to the end of the hostname. This can be done on the command line or in interactive mode. For example, the
       hostname  mynode+18  would indicate the power control operation should be sent to the host mynode, and 18
       is the identifier of a possible sub-device to be power controlled.  The  --consolidate-output  option  is
       commonly disabled when using an OEM power control that requires extra arguments.

       Because  OEM power control may involve subtypes, it is possible a user may wish to power control multiple
       sub-devices on the same host. For example, you might specify the hosts mynode+1,mynode+2,  indicating  to
       power control subdevice 1 and 2 on mynode.  Because many BMCs cannot handle multiple IPMI sessions, power
       control operations to the same host will be serialized internally by ipmipower.

       The following are the current OEM power types available, along with information on the systems they  work
       with and the power control operations available.

       C410X  This  OEM  power type supports the power control of PCIe slots on Dell Poweredge C410x systems. It
              supports on, off, and stat. The PCIe slot number ranges from 1-16 and  must  always  be  specified
              when  attempting  to  power  control with this extension. For example, the hostname mynode+2 would
              inform ipmipower to operate on slot number 2 on mynode.  The  C410x  appears  to  have  difficulty
              handling  new  slot  power  control  requests  until  prior ones have completed. Users may wish to
              strongly consider using the --wait-until-on and --wait-until-off options if multiple slots will be
              power controlled in short succession.

       NONE   This  informs  ipmipower  that  no  OEM power type extension is to be used and standard IPMI power
              control is used. This is the default.

HOSTRANGED SUPPORT

       Multiple hosts can be input either as an explicit comma separated lists of hosts or a range of  hostnames
       in  the  general  form:  prefix[n-m,l-k,...],  where  n  < m and l < k, etc. The later form should not be
       confused with regular expression character classes (also denoted by []). For example,  foo[19]  does  not
       represent foo1 or foo9, but rather represents a degenerate range: foo19.

       This  range  syntax  is  meant  only  as  a convenience on clusters with a prefixNN naming convention and
       specification of ranges should not be considered necessary -- the list foo1,foo9 could  be  specified  as
       such, or by the range foo[1,9].

       Some examples of range usage follow:
           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
           foo[7,9-10] instead of foo7,foo9,foo10
           foo[0-3] instead of foo0,foo1,foo2,foo3

       As  a  reminder  to  the  reader,  some  shells  will  interpret brackets ([ and ]) for pattern matching.
       Depending on your shell, it may be necessary to enclose ranged lists within quotes.

       When multiple hosts are specified by the user, a socket will be created for  each  host  and  polled  on,
       effectively  allowing  communication  to  all  hosts  in parallel. This will allow communication to large
       numbers of nodes far more quickly than if done in serial.  The -F option  can  configure  the  number  of
       nodes that can be communicated with in parallel at the same time.

       By  default,  standard output from each node specified will be output with the hostname prepended to each
       line. Although this output is readable in  many  situations,  it  may  be  difficult  to  read  in  other
       situations.  For  example, output from multiple nodes may be mixed together. The -B and -C options can be
       used to change this default.

EXAMPLES

       Determine the power status of foo[0-2] with null username and password
               ipmipower -h foo[0-2] --stat

       Determine the power status of foo[0-2] with non-null username and password
               ipmipower -h foo[0-2] -u foo -p bar --stat

       Hard reset nodes foo[0-2] with non-null username and password
               ipmipower -h foo[0-2] -u foo -p bar --reset

GENERAL TROUBLESHOOTING

       Most often, IPMI problems are due to configuration problems.

       IPMI over LAN problems involve a misconfiguration of the remote machine's BMC.  Double check to make sure
       the  following are configured properly in the remote machine's BMC: IP address, MAC address, subnet mask,
       username, user  enablement,  user  privilege,  password,  LAN  privilege,  LAN  enablement,  and  allowed
       authentication type(s). For IPMI 2.0 connections, double check to make sure the cipher suite privilege(s)
       and K_g key are configured properly. The ipmi-config(8) tool can be used to  check  and/or  change  these
       configuration settings.

       In  addition  to  the  troubleshooting  tips below, please see WORKAROUNDS below to also if there are any
       vendor specific bugs that have been discovered and worked around.

       Listed below are many of the common issues for error messages.  For additional support, please e-mail the
       <freeipmi-users@gnu.org> mailing list.

       "username  invalid"  -  The username entered (or a NULL username if none was entered) is not available on
       the remote machine. It may also be possible the remote BMC's username configuration is incorrect.

       "password invalid" - The password entered (or a NULL password if none was entered) is not correct. It may
       also be possible the password for the user is not correctly configured on the remote BMC.

       "password  verification  timeout"  -  Password  verification  has  timed out.  A "password invalid" error
       (described above) or a generic "session timeout" (described below) occurred.  During this  point  in  the
       protocol it cannot be differentiated which occurred.

       "k_g  invalid"  - The K_g key entered (or a NULL K_g key if none was entered) is not correct. It may also
       be possible the K_g key is not correctly configured on the remote BMC.

       "privilege level insufficient" -  An  IPMI  command  requires  a  higher  user  privilege  than  the  one
       authenticated  with.  Please try to authenticate with a higher privilege. This may require authenticating
       to a different user which has a higher maximum privilege.

       "privilege level cannot be obtained  for  this  user"  -  The  privilege  level  you  are  attempting  to
       authenticate  with  is  higher  than  the  maximum  allowed  for this user. Please try again with a lower
       privilege. It may also be possible the maximum privilege level allowed  for  a  user  is  not  configured
       properly on the remote BMC.

       "authentication  type  unavailable  for  attempted privilege level" - The authentication type you wish to
       authenticate with is not available  for  this  privilege  level.  Please  try  again  with  an  alternate
       authentication  type  or  alternate privilege level. It may also be possible the available authentication
       types you can authenticate with are not correctly configured on the remote BMC.

       "cipher suite id unavailable" - The cipher suite id you wish to authenticate with is not available on the
       remote  BMC.  Please  try  again with an alternate cipher suite id. It may also be possible the available
       cipher suite ids are not correctly configured on the remote BMC.

       "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine. Please try to  use  IPMI  1.5
       instead.

       "connection  timeout"  -  Initial  IPMI  communication failed. A number of potential errors are possible,
       including an invalid hostname specified, an IPMI IP address cannot be resolved, IPMI is  not  enabled  on
       the remote server, the network connection is bad, etc. Please verify configuration and connectivity.

       "session  timeout"  -  The IPMI session has timed out. Please reconnect.  If this error occurs often, you
       may wish to increase the retransmission timeout. Some remote BMCs are considerably slower than others.

       "internal IPMI error" - An IPMI error has occurred that FreeIPMI does not know how to handle.  Please  e-
       mail <freeipmi-users@gnu.org> to report the issue.

IPMIPOWER TROUBLESHOOTING

       When  powering on a powered off machine, the client must have a means by which to resolve the MAC address
       of the remote machine's ethernet card. While most modern IPMI solutions support the ability  to  ARP  and
       resolve  addresses  when the machine is powered off, some older machines do not. This is typically solved
       in one of two ways:

       1) Enable gratuitous ARPs on the remote machine. The remote machine will send out a gratuitous ARP, which
       advertises  the  ethernet IP and MAC address so that other machines on the network this information their
       local ARP cache. For large clusters, this method is not recommended since gratuitous ARPs can  flood  the
       network with unnecessary traffic.

       2)  Permanently  store  the  remote machine's MAC address in the local ARP cache. This is the more common
       approach on large clusters.

       Other methods are listed in the IPMI specification.

WORKAROUNDS

       With so many different vendors implementing their own IPMI solutions,  different  vendors  may  implement
       their  IPMI protocols incorrectly. The following describes a number of workarounds currently available to
       handle discovered compliance issues. When possible, workarounds have been implemented  so  they  will  be
       transparent  to  the user. However, some will require the user to specify a workaround be used via the -W
       option.

       The hardware listed below may only indicate the hardware that a problem was discovered on. Newer versions
       of  hardware  may  fix the problems indicated below. Similar machines from vendors may or may not exhibit
       the same problems. Different vendors may license their firmware from the same IPMI firmware developer, so
       it may be worthwhile to try workarounds listed below even if your motherboard is not listed.

       If  you  believe  your  hardware  has  an  additional  compliance  issue  that  needs  a workaround to be
       implemented,   please   contact    the    FreeIPMI    maintainers    on    <freeipmi-users@gnu.org>    or
       <freeipmi-devel@gnu.org>.

       authcap  -  This  workaround  flag  will  skip  early  checks  for  username capabilities, authentication
       capabilities, and K_g support and allow IPMI authentication to succeed. It works around  multiple  issues
       in  which  the remote system does not properly report username capabilities, authentication capabilities,
       or K_g status. Those hitting this issue may see "username invalid", "authentication type unavailable  for
       attempted  privilege  level",  or "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4,
       Intel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

       nochecksumcheck - This workaround flag will tell FreeIPMI to not check the checksums returned  from  IPMI
       command  responses.  It  works around systems that return invalid checksums due to implementation errors,
       but the packet is otherwise valid. Users are  cautioned  on  the  use  of  this  option,  as  it  removes
       validation  of  packet  integrity in a number of circumstances. However, it is unlikely to be an issue in
       most situations. Those hitting this issue may see "connection timeout", "session timeout",  or  "password
       verification  timeout"  errors. On IPMI 1.5 connections, the "noauthcodecheck" workaround may also needed
       too. Issue observed on Supermicro X9SCM-iiF, Supermicro X9DRi-F, and Supermicro X9DRFR.

       idzero - This workaround flag will allow empty session IDs to be accepted by the client. It works  around
       IPMI  sessions  that  report  empty  session IDs to the client. Those hitting this issue may see "session
       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

       unexpectedauth - This workaround flag will allow unexpected non-null authcodes to be  checked  as  though
       they  were expected. It works around an issue when packets contain non-null authentication data when they
       should be null due to disabled per-message authentication. Those hitting  this  issue  may  see  "session
       timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

       forcepermsg  -  This  workaround  flag will force per-message authentication to be used no matter what is
       advertised by the remote system. It works around an issue when per-message authentication  is  advertised
       as  disabled on the remote system, but it is actually required for the protocol. Those hitting this issue
       may see "session timeout" errors.  Issue observed on IBM eServer 325.

       endianseq - This workaround flag will flip the endian of  the  session  sequence  numbers  to  allow  the
       session  to  continue  properly.  It  works  around  IPMI 1.5 session sequence numbers that are the wrong
       endian.  Those hitting this issue may see "session timeout" errors.  Issue  observed  on  some  Sun  ILOM
       1.0/2.0 (depends on service processor endian).

       noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the authentication codes returned
       from IPMI 1.5 command responses. It works around systems that return invalid authentication codes due  to
       hashing  or  implementation  errors.  Users  are  cautioned  on  the use of this option, as it removes an
       authentication check verifying the validity of a packet. However, in most organizations, this is unlikely
       to  be  a  security  issue.  Those hitting this issue may see "connection timeout", "session timeout", or
       "password verification timeout" errors.  Issue observed on Xyratex  FB-H8-SRAY,  Intel  Windmill,  Quanta
       Winterfell, and Wiwynn Windmill.

       intel20  - This workaround flag will work around several Intel IPMI 2.0 authentication issues. The issues
       covered include padding of usernames, and password truncation if the authentication  algorithm  is  HMAC-
       MD5-128.  Those  hitting  this  issue  may  see  "username invalid", "password invalid", or "k_g invalid"
       errors. Issue observed on Intel SE7520AF2 with Intel Server Management Module (Professional Edition).

       supermicro20 - This workaround flag will work around several Supermicro IPMI 2.0 authentication issues on
       motherboards   w/   Peppercon   IPMI  firmware.  The  issues  covered  include  handling  invalid  length
       authentication codes. Those hitting this issue may see "password  invalid"  errors.   Issue  observed  on
       Supermicro H8QME with SIMSO daughter card. Confirmed fixed on newerver firmware.

       sun20 - This workaround flag will work work around several Sun IPMI 2.0 authentication issues. The issues
       covered include invalid lengthed hash keys, improperly hashed keys, and  invalid  cipher  suite  records.
       Those  hitting  this  issue may see "password invalid" or "bmc error" errors.  Issue observed on Sun Fire
       4100/4200/4500 with ILOM.  This workaround automatically includes the "opensesspriv" workaround.

       opensesspriv - This workaround flag will slightly  alter  FreeIPMI's  IPMI  2.0  connection  protocol  to
       workaround  an  invalid  hashing algorithm used by the remote system. The privilege level sent during the
       Open Session stage of an IPMI 2.0 connection is used for hashing keys instead of the privilege level sent
       during the RAKP1 connection stage. Those hitting this issue may see "password invalid", "k_g invalid", or
       "bad rmcpplus status code" errors.  Issue  observed  on  Sun  Fire  4100/4200/4500  with  ILOM,  Inventec
       5441/Dell  Xanadu  II,  Supermicro  X8DTH,  Supermicro  X8DTG,  Intel  S5500WBV/Penguin Relion 700, Intel
       S2600JF/Appro 512X, Quanta QSSC-S4R/Appro GB812X-CN, and Dell C5220.  This  workaround  is  automatically
       triggered with the "sun20" workaround.

       integritycheckvalue  -  This  workaround flag will work around an invalid integrity check value during an
       IPMI 2.0 session establishment when using Cipher Suite ID 0.  The  integrity  check  value  should  be  0
       length,  however the remote motherboard responds with a non-empty field. Those hitting this issue may see
       "k_g invalid" errors. Issue observed on Supermicro X8DTG, Supermicro X8DTU,  and  Intel  S5500WBV/Penguin
       Relion 700, and Intel S2600JF/Appro 512X.

       ipmiping  -  This  workaround option will inform ipmipower to use IPMI based ping packets instead of RMCP
       ping packets. Some motherboards have been observed to not implement RMCP ping/pong support despite  being
       required  by  the  IPMI  specification.  Issue  observed on Intel Windmill, Quanta Winterfell, and Wiwynn
       Windmill.

       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been found to not  support  IPMI  1.5.
       Those hitting this issue may see "ipmi 2.0 unavailable" or "connection timeout" errors. This issue can be
       worked around by using IPMI 2.0 instead of IPMI 1.5 by specifying --driver-type=LAN_2_0.  Issue  observed
       on a number of HP and Supermicro motherboards.

DIAGNOSTICS

       Upon successful execution, exit status is 0. On error, exit status is 1.

       If  multiple  hosts  are  specified  for  communication,  the exit status is 0 if and only if all targets
       successfully execute. Otherwise the exit status is 1.

       When operating in interactive mode, the exit value will be based on the last power operation executed.

KNOWN ISSUES

       On older operating systems, if you input your username, password, and other potentially security relevant
       information  on the command line, this information may be discovered by other users when using tools like
       the ps(1) command or looking in the /proc file system. It is generally  more  secure  to  input  password
       information  with  options  like  the  -P or -K options. Configuring security relevant information in the
       FreeIPMI configuration file would also be an appropriate way to hide this information.

       In order to prevent brute force attacks, some BMCs will temporarily "lock up" after a  number  of  remote
       authentication  errors.  You  may need to wait awhile in order to this temporary "lock up" to pass before
       you may authenticate again.

       IPMI specifications do not require  BMCs  to  perform  a  power  control  operation  before  returning  a
       completion  code  to  the caller.  Therefore, it is possible for ipmipower to return power status queries
       opposite of what you are expecting.  For example, if a "power off" operation  is  performed,  a  BMC  may
       return  a successful completion code to ipmipower before the "power off" operation is actually performed.
       Subsequent power status queries may return "on" for several seconds, until the BMC actually performs  the
       "power off" operation.

REPORTING BUGS

       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

       Copyright (C) 2007-2015 Lawrence Livermore National Security, LLC.
       Copyright (C) 2003-2007 The Regents of the University of California.

       This  program  is  free  software;  you  can  redistribute it and/or modify it under the terms of the GNU
       General Public License as published by the Free Software Foundation; either version 3 of the License,  or
       (at your option) any later version.

SEE ALSO

       freeipmi.conf(5), freeipmi(7), ipmi-config(8), ipmi-oem(8)

       http://www.gnu.org/software/freeipmi/